Analytical and experimental investigation of stator endwall contouring in a small axial-flow turbine. 1: Stator performance

Three stator configurations were studied to determine the effect of stator outer endwall contouring on stator performance. One configuration was a cylindrical stator design. One contoured stator configuration had an S-shaped outer endwall, the other had a conical-convergent outer endwall. The experimental investigation consisted of annular surveys of stator exit total pressure and flow angle for each stator configuration over a range of stator pressure ratio. Radial variations in stator loss and aftermixed flow conditions were obtained when these data were compared with the analytical results to assess the validity of the analysis, good agreement was found.

Haas, J. E.↗

Effects of reset stators and a rotating, grooved stator hub on performance of a 1.92-pressure-ratio compressor stage

The overall performance and blade-element performance of a transonic fan stage are presented for two modified test configurations and are compared with the unmodified stage. Tests were conducted with reset stators 2 deg open and reset stators with a rotating grooved stator hub. Detailed radial and circumferential (behind stator) surveys of the flow conditions were made over the stable operating range at rotative speeds of 70, 90, and 100 percent of design speed. Reset stator blade tests indicated a small increase in stage efficiency, pressure ratio, and maximum weight flow at each speed. Performance with reset stators and a rotating, grooved stator hub resulted in an additional increase in stage efficiency and pressure ratio at all speeds. The rotating grooved stator hub reduced hub losses considerably.

Lewis, G. W., Jr.↗

Evaluation of ceramics for stator applications: Gas turbine engines interim report. Stator fabrication and evaluation

The objective was to assess current ceramic materials, fabrication processes, reliability prediction, and stator durability when subjected to simulated automotive gas turbine engine operating conditions. Ceramic one-piece stators were fabricated of two materials, silicon nitride and silicon carbide, using two near-net-shape processes, slip casting and injection molding. Non-destructive evaluation tests were conducted on all stators identifying irregularities which could contribute to failures under durability testing. Development of the test rig and automatic control system for repeatably controlling air flow rate and temperature over a highly transient durability duty cycle is discussed. Durability results are presented for repeated thermal cycle testing of the ceramic one-piece stators. Two duty cycles were used, encompassing the temperature ranges of 704 to 1204 C (1300 to 2200 F) and 871 to 1371 C (1600 to 2500 F). Tests were conducted on 28 stators, accumulating 135,551 cycles in 2441 hours of hot testing. Cyclic durability for the ceramic one-piece stator was demonstrated to be in excess of 500 hours, accumulating over 28,850 thermal cycles. Ceramic interface forces were found to be the significant factor in limiting stator life rather than the scatter in material strength properties or the variation in component defects encountered.

Arnon, N.↗

Design and performance of controlled-diffusion stator compared with original double-circular-arc stator

The capabilities of two stators, one with controlled-diffusion (CD) blade sections and one with double-circular-arc (DCA) blade sections, were compared. A CD stator was designed and tested that had the same chord length but half the blades of the DCA stator. The same fan rotor (tip speed, 429 m/sec; pressure ratio, 1.65) was used with each stator row. The design and analysis system is briefly described. The overall stage and rotor performances with each stator are compared, as are selected blade element data. The minimum overall efficiency decrement across the stator was approximately 1 percentage point greater with the CD balde sections than with the DCA blade sections.

Gelder, Thomas F.↗

Design and performance of controlled-diffusion stator compared with original double-circular-arc stator

The capabilities of two stators, one with controlled-diffusion (CD) blade sections and one with double-circular-arc (DCA) blade sections, were compared. A CD stator was designed and tested that had the same chord length but half the blades of the DCA stator. The same fan rotor (tip speed, 429 m/sec; pressure ratio, 1.65) was used with each stator row. The design and analysis system is briefly described. The overall stage and rotor performances with each stator are compared, as are selected blade element data. The minimum overall efficiency decrement across the stator was approximately 1 percentage point greater with the CD blade sections than with the DCA blade sections.

Gelder, Thomas F.↗

Experimental results for labyrinth gas seals with honeycomb stators - Comparisons to smooth-stator seals and theoretical predictions

Experimental measurements are presented for the rotordynamic stiffness and damping coefficients of a teeth-on-rotor labyrinth seal with a honeycomb stator. Inlet circumferential velocity, inlet pressure, rotor speed, and seal clearance are primary variables. Results are compared to data for teeth-on-rotor labyrinth seals with smooth stators and to analytical predictions from a two-control-volume compressible flow model. The experimental results show that the honeycomb-stator configuration is more stable than the smooth-stator configuration at low rator speeds. At high rotor speeds, the stator surface does not affect stability. The theoretical model predicts the cross-coupled stiffness of the honeycomb-stator seal correctly within 25 percent of measured values. The model provides accurate predictions of direct damping for large clearance seals; however, the model predictions and test results diverge with increasing running speed. Overall, the model does not perform as well for low clearance seals as for high clearance seals.

Hawkins, Larry↗

Effect of Various Blade Modifications in Performance of a 16-Stage Axial-flow Compressor. IV - Effect on Over-all Performance Characteristics of Decreasing Twelfth through Fifteenth Stage Stator-blade Angles 3 deg and Increasing Stator Angles in the Inlet Stages

The performance of a 16-stage axial-flow compressor, in which two modifications of unloaded inlet stages were combined with loaded exit stages, has been determined. In the first modification the exit stages were loaded by decreasing the twelfth through fifteenth stage stator angles 3 deg. as compared with the blade angles in the original compressor, and the inlet stages were unloaded by increasing the blade angles the following amounts: guide vanes and first-stage stator, 6 deg; second- and third-stage stators, 4 deg.; and fourth-stage stators, 3 deg. The over-all performance of this configuration was compared with that of the compressor with the original blade angles. The peak efficiency was increased at all speeds below design and the weight flow was higher at speeds below 80 percent of design, the same at 80 percent of design, and lower at speeds abovce 80 percent of design. The maximum reduction in weight flow occurred at design speed. The surge limit line was higher at speeds between 75 and 90 percent of design when presented on a pressure ratio against weight flow basis. The second configuration was the same as the first with the exception that the second-, third-, and fourth-stage stator blade angles were the same as in the compressor with the original blade angles. A comparison of the performance of this configuration with that of the compressor with the original blade angles showed the same general trends of changes in performance as the first configuration. Comparisons were made of compressor configurations to show the effects upon the performance of decreased loading in the inlet stages. Below 75 percent of design speed, decreased loading results in increased weight flow and peak efficiency; above 80 percent of design speed, decreased loading in the inlet stages results in decreased weight flow and small changes in peak efficiencies. Between 75 and 90 percent of design the changes in surge weight flow and pressure ratio were such that the surge limit line was raised with decreased loading in the inlet stages when presented as pressure ratio against weight flow.

Hatch, James E.↗

Effects of long-chord acoustically treated stator vanes on fan noise. 1: Effect of long chord (taped stator)

A set of long-chord stator vanes was designed to replace the vanes in an existing fan stage. The long vanes consisted of a turning section and axial extension pieces, both of which incorporated acoustic damping material. The acoustic damping material was made inactive for these tests by covering with metal tape, and the stator vanes were tested in three length configurations. Compared to the values for the original stage, broadband noise was reduced in the middle to high frequencies with the long stator vanes, but a broadband noise increase was observed at the low frequencies. No change was observed in the blade passage tone, but some aft end reduction in the overtones was observed.

Dittmar, J. H.↗

Component Performance Investigation of J71 Experimental Turbine VII: Effect of First-stator Adjustment; Over-all Performance of J71-97 Turbine with 87-percent-design Stator Area

The performance results, as well as a compressor-turbine match point study based on a particular mode of engine operation, are compared with those previously obtained with the same turbine having first-stator areas 70, 95.6, and 132 percent of design. Maximum efficiencies for all turbine configurations were high, on the order of 87 to 89 percent. The efficiencies obtained at the match points for the 87-, 95.6-, and 132-percent turbines were slightly lower. No match point for the 70-percent turbine was obtained because, with first-stator areas less than 75.5 percent of design, the turbine would develop insufficient work to drive the compressor at the match point.

Schum, Harold J↗