Search NASA⌕ Search

SEARCH · Search NASA

Results for “Steam compression”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evaluation of Mechanical and Thermomechanical Water Vapor Compression Techniques for Enabling High Temperature Lift Hydration-Based Chemical Heat Pumps

Achieving high temperature lifts (>200 K) via a chemical heat pump based on salt hydration/dehydration reactions requires the transport of water vapor from low to high pressure. Alternative compression approaches require condensing of low-pressure water vapor, pumping of liquid water, and subsequent evaporation when the low-side pressure corresponds to sub-ambient water saturation temperatures. Thus, this study compares four steam compression methods for use within a chemical heat pump system based on a reversible calcium oxide hydration/dehydration reaction with a temperature lift from 350 °C heat to >600 °C. Purely mechanical and thermochemical/mechanical compression technologies are considered. A parametric study of maximum allowable temperature, the isentropic efficiency of mechanical compressors, the effectiveness of heat exchangers, and the assumed allowable heat exchanger pressure drop is conducted to determine the mechanical and thermal energy consumed per kilogram of compressed steam. The system complexity in terms of the number of main system components, maximum pressure ratio, and maximum allowable temperature is estimated. Model results show an absorption-based steam compressor has the highest exergetic efficiency for the required chemical heat pump required conditions. As a result, this system configuration was then experimentally demonstrated to illustrate the impact of system performance on component effectiveness.

Advanced reactors↗

RELAP-7 Application and Enhancement for FLEX Strategies and ATF Behavior under Extended Loss of AC Power Conditions

This report summarizes the results of a three-year research project sponsored by the U.S. Department of Energy (DOE) Nuclear Energy University Program (NEUP) to enhance and apply the RELAP-7 code by adding and improving several important components (e.g., a mechanistic Reactor Core Isolation Cooling (RCIC) system model) for thermal hydraulic studies of LWRs under ELAP conditions and evaluating the time available for transition to portable FLEX equipment. The project team included University of Massachusetts–Lowell, The Ohio State University, Texas A&M University, Idaho National Laboratory and Oak Ridge National Laboratory. In the Fukushima accident, it was found that the RCIC system played a crucial role in delaying core meltdown by almost three days in Fukushima Daiichi Unit 2, because of self-regulated operation of the steam driven RCIC turbine-pump injection system. Steam flow in the convergent-divergent nozzles of the RCIC Terry turbine is two-phase non-equilibrium transonic flow with homogenous nucleation condensation. To more accurately predict the dynamic process and behavior of the transonic compressible steam flow, a one-dimensional transient two-phase analytical model is presented. A simplified four-fluid model was employed in the present work with the consideration of four separate fluid fields: vapor, liquid film, entrained droplets and condensed droplets. The mass, momentum and energy interactions between the fluids were considered and modeled. An extended seven-equation non-equilibrium critical flow model was developed to obtain the critical pressure and velocities of each phase at the nozzle throat. To predict the wetness in the divergent section, a mechanistic nucleation condensation model was integrated in the nozzle analysis model, considering the generation and consequent growth of droplets. The governing differential equations on a staggered grid were discretized using the second-order Lax-Wendroff scheme with a flux limiter, and the Semi-Implicit Method for Pressure-Linked Equation (SIMPLE) algorithm was employed to solve the discrete linear system. To demonstrate the predictability and reliability of the physical models and the numerical method proposed in the present work, three representative nozzles were modeled and simulated. The results show good agreement with the available experimental data, even for condensation shock. Then, the 1D nozzle model was employed to obtain nozzle flow tables of the Terry turbine nozzle for different working pressures which can cover the operation pressure range of the RCIC system. A mechanistic RCIC turbine-pump system model was developed and implemented in the system code TRACE to simulate dynamic responses of the RCIC system under Beyond Design Basis Accident (BDBA) conditions. The turbine-pump governing equations are based on the control volume approach of the angular momentum balance. The physics based mechanistic RCIC model was developed using the TRACE control system components (i.e., signal variables, control blocks, and tables), and incorporated into a TRACE boiling water reactor (BWR) model. The TRACE model in this report has a detailed nodalization of the reactor pressure vessel (RPV), and all of the major flow paths and system components, including the safety relief valves (SRVs) and the containment suppression pool and drywell. Based on the nozzle flow tables generated from the 1D nozzle model developed, the turbine drive torque can be calculated from table lookup. Since the detailed specifications of the RCIC pump are unavailable, the homologous curves for a Bingham pump were used in the current pump component. A station black-out (SBO) accident test problem was selected to demonstrate the TRACE RCIC model. The short-term SBO simulations were performed for two cladding materials: Zircaloy and FeCrAl, to demonstrate the effect of the accident tolerant fuel cladding on fuel heat-up under BDBA accident conditions. The wetwell plays a vital safety role in SBO and other BWR accident scenarios in that it can reduce containment pressure and supply additional core make-up water. The suppression pool temperature distribution has a very large impact on both RPV and containment pressure. Thus, another novel contribution of the project comes mainly from an improved, systems-level wetwell model which can capture buoyancy-induced thermal stratification effects due to steam injection and condensation. A two-zone stratified wetwell model has been implemented in RELAP-7 and some results from that model are presented. This wetwell model is capable of simulating thermal stratification due to a low steam mass injection rate. With a low mass flow rate, the model assumes that all the steam condenses within the pipe and the resulting plume can be approximated with a purely buoyant, heat-source driven model. The wetwell model developed with these assumptions is adequate to simulate slow transients such as extended SBO transients.

42 ENGINEERING↗

Predicting industrial building energy consumption with statistical and machine-learning models informed by physical system parameters

The industrial sector consumes about one-third of global energy, making them a frequent target for energy use reduction. Variation in energy usage is observed with weather conditions, as space conditioning needs to change seasonally, and with production, energy-using equipment is directly tied to production rate. Previous models were based on engineering analyses of equipment and relied on site-specific details. Others consisted of single-variable regressors that did not capture all contributions to energy consumption. Further, new modeling techniques could be applied to rectify these weaknesses. Applying data from 45 different manufacturing plants obtained from industrial energy audits, a supervised machine-learning model is developed to create a general predictor for industrial building energy consumption. The model uses features of air enthalpy, solar radiation, and wind speed to predict weather-dependency; motor, steam, and compressed air system parameters to capture support equipment contributions; and operating schedule, production rate, number of employees, and floor area to determine production-dependency. Results showed that a model that used a linear regressor over a transformed feature space could outperform a support vector machine and utilize features more representative of physical systems. Using informed parameters to build a reliable predictor will more accurately characterize a manufacturing facility's energy savings opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MEASUR - Manufacturing Energy Assessment Software for Utility Reduction

MEASUR your energy savings with the free DOE MEASUR software The Department of Energy (DOE), with Oak Ridge National Laboratory (ORNL), released version 1.0 of their energy efficiency software tool MEASUR (Manufacturing Energy Assessment Software for Utility Reduction). MEASUR has been available for several years as a beta version, being tested by industry experts and real users, and will continue to be updated and improved in the coming years. It is an integrated suite of tools to aid manufacturers in improving the efficiency of energy systems and equipment within a plant, including motors, pumps, fans, process heating, steam, and compressed air. Additionally, there are modules for wastewater energy analysis and to help perform energy treasure hunts. Several calculators are also included, allowing users to independently perform smaller calculations and analyses (such as estimating pump head, performing a fan traverse analysis, estimating waste heat recovery potential, and cataloging compressed air leaks). The MEASUR modules are based on previous DOE software tools that have been used by industry since the early 2000s (such as MotorMaster, AirMaster+, PSAT, PHAST, and FSAT). The original tools only ran on Windows operating systems, and by Windows 10, most of them were inoperable. DOE started their energy efficiency software tool revitalization effort in 2016, first with PSAT (for pumps), then began to integrate the other tools and expand their functionality and utility. The new MEASUR suite provides an extensively more user-friendly, modern, and versatile set of tools. All the assessment modules and most of the calculators have several visual components and graphs and detailed help text for every user input. To help reach international users, the tool utilizes Google translate and users can easily change unit systems, even converting existing user inputs if desired. The assessment files can be organized within the internal file system and easily shared to other users, regardless of their operating system. The entire suite is free, open-source, and can be downloaded on Windows, Mac, or Linux operating systems.

Accawi, Gina [Oak Ridge National Lab. (ORNL), Oak ↗

Investigation of a Hybrid Carbon Capture System at a NGCC Power Plant That Performs Direct Air Capture During Off-Peak Hours

The goal of this project was to investigate the feasibility of coupling NGCC power plants with membrane and solid sorbent carbon capture to achieve net negative carbon emissions. This novel hybrid system has a couple of potential benefits: 1) the carbon capture systems could help the NGCC plant by minimizing its carbon footprint and giving it a new revenue stream from direct air capture, and 2) the NGCC plant could help direct air capture scale up quickly and costeffectively by providing it with electricity, steam and compressed air streams. In order to investigate this hybrid design, we developed a complex, integrated system model consisting of: 1) a NGCC power plant model developed by Dr. Bhattacharyya’s team at WVU, 2) a membrane carbon capture model developed by Dr. Lipscomb’s team at U Toledo, and 3) a solid sorbent carbon capture model developed by Dr. Hornbostel’s team at U Pittsburgh. Mr. Matuszewski’s team at AristoSys LLC integrated these three models into a single, integrated model using FOQUS, an optimization tool developed by the NETL CCSI 2 program. Optimizations were then performed on this integrated model to determine the cost and carbon capture rates under a range of electricity and carbon price scenarios.

20 FOSSIL-FUELED POWER PLANTS↗

Hydrogen-Steam Separation Using Mechanical Vapor Recompression Cycle

Solar thermochemical hydrogen and fuel production is a promising pathways for producing sustainable fuels and chemicals. One of the main challenges in the development of these systems is their low steam conversion extent, dictated by its restrictive thermodynamics requiring extremely high temperatures and low oxygen partial pressure to obtain conversions over 10 \%. While condensing the unreacted steam is technically simple, the latent heat is thus lost, which can be larger than the producd hydrogen higher heating value. We propose to use a modified mechanical vapor recompression cycle, allowing to recover the latent heat by compressing the steam-hydrogen mixture prior to the condensation process, thus creating a temperature different between the hot exhaust and cold inlet streams. We show that this method can recover over 90 % of the latent heat, thus increasing the viability of solar thermochemical hydrogen production cycles even under limited conversion conditions.

hydrogen technology↗

West Virginia University Industrial Assessment Center (Final Progress Report)

The Industrial Assessment Center at West Virginia University has been successful in workforce development, and in generation of energy savings for manufacturing facilities during the period 2016 to 2021. Graduate and undergraduate students have benefited from energy assessment experience and most of them have found good positions as energy engineers and analysts in the industrial sector. Several peer reviewed research papers in archival journals as well as conference papers on the topic of energy engineering and assessment have been published. The implemented energy savings for manufacturing facilities have been significant in the areas of lighting, compressed air, process heating, steam, HVAC, chillers and cooling towers, and motors. In addition, water use reduction, smart manufacturing applications to save energy, cyber security evaluation, energy management, productivity improvements and waste reduction opportunities that lead to energy intensity reductions have been explored. The students have obtained an opportunity to interact with energy efficiency and productivity improvement professionals at various conferences and workshops and their research has generated important results. In summary, the West Virginia University Industrial Assessment Center (WVU-IAC) has fulfilled its mission in regard to workforce development, energy efficiency for manufacturing facilities, and laid a strong platform enhancing sustainability through reductions in carbon emissions achieved through energy efficiency and energy management initiatives and reductions in water usage and waste reduction. During the project period (2016-2021) the WVU-IAC has made numerous energy efficiency, water use reduction, waste reduction, and productivity improvement recommendations, a significant number of them having been implemented by the manufacturing facilities. The research adds significant understanding to the area of energy efficiency, water and waste reduction, and productivity improvement. The technical effectiveness and economic feasibility of the methods and techniques investigated and demonstrated through this project have been exemplary, resulting in significant recommended and implemented resource savings and reductions in carbon emissions. The project has been of significant benefit to the public owing to replication of results within the industrial sector, thus reducing operating costs for businesses that result in increase of growth and employment, as well as community benefits in terms of reductions in carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimization of energy requirements for CO 2 post-combustion capture process through advanced thermal integration

The energy optimization modeling work described here was performed to determine efficiency improvements that could be achieved for existing coal-fired power plants to retrofit a partial CO 2 capture from the post-combustion flue gas for carbon sequestration through thermal integration. The work presented includes optimization of the mono-ethanol amine (MEA)-based post-combustion CO 2 capture to reduce energy requirements that could be achieved at existing power plants by thermal integration of the steam turbine cycle, boiler, CO 2 compression train and post-combustion CO 2 capture process to offset efficiency and capacity losses that would be incurred by retrofit or implementation of post-combustion CO 2 capture. Furthermore, partial CO 2 capture, involving treatment of less than 100% of the flue gas leaving the plant and modular design of the CO 2 scrubbing system, was also investigated. Thermal integration of the steam turbine cycle with boiler and CO 2 compression train improved cycle and plant performance and offset, in part, the negative effects of post-combustion CO 2 capture. The best-analyzed integration options improved gross power output by 5% and net unit efficiency by 1.57%, relative to the conventional MEA process. Operating with 40% CO 2 capture increased gross power output by 11.6–14% (depending on the MEA thermal integration option), relative to the conventional MEA integration and 90% CO 2 capture. The improvement in net unit performance is larger compared to the improvement in turbine cycle performance because of the CO 2 compression work, which is also reduced by partial CO 2 capture.

42 ENGINEERING↗

Economic viability of using thermal energy storage for flexible carbon capture on natural gas power plants

Fossil fuel-based power plants generate 80% of the electricity in the United States and provide a reliable generation source for both base and peak power demands. These plants are expected to adapt to changes in environmental policies that will require carbon management with carbon capture and storage (CCS) representing a possible solution. Current solvent-based CCS has a detrimental impact on a power plant's performance due to large heat loads required for carbon capture solvent regeneration. This parasitic load restricts the power plant's output and operation flexibility. Therefore, this study evaluates the feasibility of using thermal storage technologies for natural gas combined cycle (NGCC) power plants coupled with CCS to minimize the impact of solvent regeneration and enable the plant to operate at peak power output. Thermal storage can minimize the impact of CCS on the power plant by providing the heat load required for solvent regeneration during times of peak demand which will allow the plant to operate unrestricted and at full power. In total, fifteen unique thermal storage configurations were evaluated from three thermal storage categories: Brayton cycle heat pump, vapor compression heat pump, and heat recovery steam generator steam extraction for storage. The viability of these systems was determined by evaluating each configuration on thousands of real-world Locational Marginal Pricing (LMP) profiles from the New York Independent System Operator and California Independent System Operator electricity markets using a techno-economic analysis. Afterwards, results were compared to the performance of a base power plant (NGCC with CCS and no thermal storage) to determine the impact of thermal storage on power plant economics. Overall, six of the thermal storage configurations performed better than base CCS enabled power plant on between 11.5% and 38.7% of the LMP signals evaluated. The best performing configuration was a vapor compression heat pump that used flue gas as the working fluid and had both hot and cold thermal storage units. This configuration performed better than the base CCS power plant on 38.7% of the LMP profiles. The results of this study show thermal storage can mitigate the economic impact of carbon capture solvent regeneration on NGCC power plants. Discussion focuses on the impact of electricity pricing on the optimal thermal storage system, the advantages and disadvantages of the systems evaluated, and identifies limitations with the study.

25 ENERGY STORAGE↗

Effect of moderate temperatures on compressive strength of ultra-high-performance concrete: A microstructural analysis

Highlights: • All coarse aggregates and steel fibres were surrounded by the binder. • X-ray diffraction is useful for explaining the increase in compressive strength with increasing temperature. • Rosenhahnite and/or quartz Dauphiné-twinned phases improved the compressive strength. • Polypropylene fibres prevented spalling and preserved the compressive strength. • Concrete with steel and polypropylene fibres did not exhibit spalling at 300 °C. Concrete with two types of steel fibres and a polypropylene fibre prevented spalling and preserved the compressive strength at 300 °C, which makes these concretes suitable for long-term applications up to 300 °C, such as for steam collectors or thermal energy storage systems. The compressive strength behaviour of three types of ultra-high-performance fibre-reinforced concrete manufactured with the same matrix was investigated. For this purpose, a complete characterisation of all the raw materials and the three types of fibres used was performed. The morphology of all concrete mixtures at room temperature was analysed using scanning electron microscopy–energy-dispersive X-ray spectroscopy. From the results, it was ascertained that the steel fibres and coarse siliceous aggregates were not in contact (being separated by ≥3.41 μm) and were surrounded by the binder (of ≥1 μm in thickness) for all the mixtures studied. Rosenhahnite and/or quartz Dauphiné-twinned phases improved the compressive strength (as determined by X-ray diffraction).

36 MATERIALS SCIENCE↗

FEED Study of Carbon Capture Inc. DAC and CarbonCure Utilization Using United States Steel's Gary Works Waste Plant

Direct Air Capture (DAC) has been proposed as a means of reducing atmospheric concentrations of CO2. While DAC has been evaluated through lab-scale, bench-scale, and small-scale pilot units, large-scale deployment has not been achieved. Feasibility studies are one tool to understand the potential design, operation, performance, and impact of commercial-scale DAC. This paper presents the results of a feasibility study for a passive DAC system deployed at >100,000 tpy scale in three different regions across the U.S. and awarded to Carbon Collect by the U.S. Department of Energy National Energy Technology Laboratory (DOE NETL). The MechanicalTree™technology has been designed and engineered by Carbon Collect based on the concept initially developed at Arizona State University Center for Negative Carbon Emissions. It uses a tower of stacked, sorbentcontaining disks supported by a lifting mechanism, exposed to the air to capture CO2 during the adsorption phase. The disks are then lowered into a regeneration chamber for vacuum and steam regeneration to produce CO2 product during the desorption step. The modular tree design allows large installations with repeatable, mass-manufactured units connected to common utilities such as steam supply, vacuum, and CO2 processing for compression and geologic storage. The passive DAC system eliminates the equipment and energy of forced air fans by using natural air circulation to contact the sorbent with the CO2 in the air. Because of this, the performance is dependent on the wind speed in addition to the temperature and relative humidity. Performance and flow rate fluctuations were incorporated into equipment and facility design with considerations for turndown to 10% of maximum rated flow to allow operation in all seasons. The feasibility study was undertaken to evaluate the technology in different regions and climates. Three locations were selected for this study representing different climates: Alabama (hot and humid), California (hot and arid), and Wyoming (continental). For each region, the adsorption/desorption cycle was optimized including tuning the heat integration and cycle timings. The performance of individual trees was then scaled to the full facility with the same design of more than 20,000 trees common between all regions. The installations had expected average CO2 capture rates of between 330,000 and 485,000 tonnes of CO2 per year depending on the climate. The initial engineering design for the facility at each location was performed with cost and performance estimates for the trees, carbon purification and compression, and the balance of plant. To supply thermal and electrical energy for the facility, carbon-free or low-carbon power must be considered. Options for low-carbon, continuous thermal and electrical energy were considered. The best-performing option from those considered was identified to be an electrically-heated molten salt energy storage system, powered by an on-site photovoltaic field. During molten salt thermal discharge, steam is produced from heat exchange with the molten salt and used to generate power in a steam turbine as well as steam for regenerating the DAC carbon trees. The thermal and electrical supply and analysis is presented in the context of low-carbon power for carbon removal. Modelling and economics of transportation and geologic storage of the CO2 is considered and presented for each location. The results of the feasibility study are incorporated into the presented techno-economic and life-cycle assessments. This work is intended to provide an understanding of the performance, cost, and impact of capturing CO2 at the commercial scale and the impact of climate and regional siting on the considered passive DAC system.

42 ENGINEERING↗

Process Design and Techno-Economic Analysis of the Modular Staged Pressurized Oxy-Combustion (SPOC) Power Plant for Biomass

This work describes the process design and techno-economic analysis (TEA) of the modular SPOC power plant for biomass firing and coal-biomass co-firing. Two Rankine cycles were considered: a supercritical steam cycle (242 bar, 593°C, 593°C) with 550 MWe net output and a subcritical cycle (166 bar, 566°C, 566°C) with 200 MWe net output. For both cases, 95% carbon capture was modeled, and hybrid poplar biomass was chosen to generate carbon-negative power. In addition, the supercritical 500 MWe case included a 25% biomass co-firing (carbon neutral) case. For both cycles, a 100% Powder River Basin coal firing case was used for comparison purposes. In the SPOC process, oxygen is produced via a cryogenic air separation unit (ASU) and the heat generated from the compression of air is integrated into the steam cycle and utilized for boiler feed water pre-heating. Unique to the SPOC process, the boilers are pressurized and arranged in a series-parallel configuration, with minimized flue gas recirculation. The flue gas is cooled and scrubbed in the direct-contact cooler (DCC) column, and the moisture in the flue gas is condensed, leaving the bottom of the DCC at a sufficiently high temperature such that it can be used for boiler feed water pre-heating, improving plant thermal efficiency. Following drying and purification, CO2 in the flue gas is at the purity required for storage or utilization. The performance data were obtained from process modelling via Aspen Plus®. The stream data from Aspen Plus® were used as an input for the AACE Class 5 cost study. Ultimately, the capital costs, Levelized Cost of Electricity (LCOE), and cost of CO2 captured and avoided were obtained. The HHV efficiency of the carbon negative 550 MWe supercritical SPOC case (34.8%) was clearly above those reported by NETL for the BECCS baseline cases of supercritical pulverized coal with capture (B12B, 31.5%) and the 49% biomass co-firing case with capture (PA3, 29.2%). The HHV efficiency of the carbon-negative subcritical plant is also higher than the subcritical baseline PC plant with capture (case B11B.95) presented by NETL (32% vs 29.7%). The LCOE for the SPOC 100% biomass case was similar to the LCOE for the BECCS 49% biomass with carbon capture case ($147/MWh), and the SPOC carbon neutral case LCOE was lower ($110/MWh) than the cost for the NETL baseline SC coal firing case with 90% carbon capture ($114/MWh).

Magalhaes, Duarte↗

Process Design and Techno-Economic Analysis of the Modular Staged Pressurized Oxy-Combustion (SPOC) Power Plant for Biomass

This work describes the process design and techno-economic analysis (TEA) of the modular stage pressurized oxy-combustion (SPOC) power plant for biomass firing and coal-biomass co-firing. The SPOC process was modelled using Aspen Plus®, and largely based on a previous model designed by this group for SPOC coal firing. To enable comparison with current National Energy Technology Laboratory (NETL) Bio-Energy Carbon Capture and Storage (BECCS) studies, a 550 MWe SPOC power plant with a supercritical Rankine cycle (241 bar, 593°C, and 593°C), and 90% carbon capture was modeled, and hybrid poplar biomass was chosen. Two cases were evaluated, namely 100% biomass (carbon negative) and 25% biomass co-firing (carbon neutral), and the 100% Powder River Basin coal firing case was chosen for comparison purposes. In the SPOC process, oxygen is produced via a cryogenic air separation unit (ASU) and the heat generated from the compression of air is integrated into the steam cycle and utilized for boiler feed water regeneration. Unique to the SPOC process, the boilers are arranged in a series-parallel configuration, with minimized flue gas recirculation. The flue gas is cooled and scrubbed in the direct-contact cooler (DCC) column, and the water leaving the bottom of the DCC is at a sufficiently high temperature that it can be used for boiler feed water heating, improving plant thermal efficiency. The SPOC efficiencies were above the BECCS cases with capture, and no efficiency penalty on the SPOC plant was observed with an increase of biomass in the mix mostly due to the higher oxygen content in biomass that resulted in lower oxygen requirement from the ASU, and the higher moisture in biomass that due to the key benefit of the SPOC process can be partially recovered as latent heat.

Magalhaes, Duarte↗

NH 4 OH Looping with Membrane CO 2 Absorber and Distributed Stripper for Enhanced Algae Growth

The University of Kentucky Center for Applied Energy (UK CAER) has devised a unique, integrated CO2 capture and utilization technology. CO2 from coal-fired power generation flue gas is first captured at half the operating cost of a typical aqueous CO2 capture system (CCS), distributed in an aqueous stream and then fixed by algae in bioreactors where the algae production is increased by 50% over that with a typical intermittent nutrient feeding system. Lower CCS operating cost is achieved by eliminating the flue gas pretreatment step for cooling and SO2 removal, eliminating steam extraction from the power generation steam cycle for solvent regeneration, and eliminating CO2 compression. Higher algae production is achieved by continuous, just-in-time nutrient feed to the bioreactors directly from a distributed solvent regenerator, which maintains the bioreactor pH for optimum growth. The process starts with a uniquely configured membrane absorber, where the flue gas is indirectly contacted with an ammonium hydroxide (NH4OH) solvent. Dissolved NH3 is attractive for both CO2 capture and as an algae nutrient. For CO2 capture it is inexpensive, has a low regeneration energy, is thermally- and oxidatively-stable and has a viscosity near that of water, which makes is easy to transport. Numerous studies have shown that the scrubbing capacity of NH3 is approximately 0.9-1.2 kg of CO2/kg of NH3, with a CO2 removal efficiency of ~99% and half the solvent regeneration energy than that of 30 wt% MEA[1, 2, 3]. NH3 is attractive as an algae nutrient due to its low cost. The rich NH4OH solvent is pumped to a set of distributed regenerators which are co-located with the algae bioreactors. Solvent pumping, transport and distribution reduces the balance of plant (BOP) cost compared to a typical aqueous CCS related to the flue gas duct and boost fan required to transport the flue gas. The energy required for the distributed solvent regeneration is supplied by solar-thermal panels eliminating the need for steam extraction from the power generation steam cycle. After solvent regeneration, the product stream contains both the CO2 captured from the flue gas and volatized NH3 from the solvent. This product stream is fed directly to the bioreactors, eliminating the need for compression of the CO2 stream. The relative amounts of CO2 and NH3 in the product stream are adjusted and controlled by a controlling the regeneration conditions (pressure and temperature). The continuous feed of the right ratio of nutrients overcomes the typical inhibition of algae growth resulting from frequent pH swings in the bioreactor due to unbalanced (intermittent) feeding systems for CO2 and N. Also, because the regenerators will operate at pressure and be located in close proximity to the bioreactors, there is no worry about pressure drop when sparging the gas into the algae. Sparging produces small bubbles which is beneficial for mass transfer efficiency. One known challenge when using an NH4OH solvent is high NH3 emission. Hydrophobic membranes are used for CO2 capture using an aqueous NH3 solution[4, 5] without the direct contact between flue gas and aqueous solution. Additionally, UK CAER CO2 capture and utilization process manages NH3 slip in three extra measures. First, NH3 slip is minimized by working with minimal species partial pressure, which is proportional to the concentration in the liquid. Hence, lowering the capture solvent concentration will lower the NH3 partial pressure. Second, UK CAER’s previous work has demonstrated that the addition of Zn2+ into NH3 solutions to chelate the NH3 can reduce NH3 volatility. Third, the configuration of the membrane CO2 absorber utilizes condensed water from the flue gas to continually wash the gas-side of the membrane to reduce fouling and recapture NH3 slip. Additional details about the UK CAER unique, integrated CO2 capture and utilization technology will be presented along with technology development plans. Diao, N., Q. Li, and Z. Fang. 2004. Heat transfer in ground heat exchangers with groundwater advection. International Journal of Thermal Sciences. 43: 1203-1211, He, Q., M. Chen, L. Meng, K. Liu, and W. Pan. 2004. Study on Carbon Dioxide Removal from Flue Gas by Absorption of Aqueous Ammonia. Western Kentucky University. Yeh, A.C., and H. Bai. 1999. Comparison of ammonia and monoethanolamine solvents to reduce CO2 greenhouse gas emissions. The Science of the Total Environment. 228: 121-133, Villeneuve, K., D. Roizard, J.C. Remigy, M. Iacono, and S. Rode. 2018. CO2 capture by aqueous ammonia with hollow fiber membrane contactors: Gas phase reactions and performance stability. Separation and Purification Technology, 199: 189-197, Toro Molina, C., and C. Bouallou. 2016. Carbon dioxide absorption by ammonia intensified with membrane contactors. Clean Techn Environ Policy 18, 2133–2146 (2016)

20 FOSSIL-FUELED POWER PLANTS↗

Process Heating Assessments Using DOE’s Manufacturing Energy Assessment Software for Utility Reduction (MEASUR) Tool Suite

Process heating is the most energy-intensive manufacturing process for most sectors of industry. To quantify energy savings from various energy conservation measures, the Department of Energy (DOE) sponsored the development of the Process Heating Assessment and Survey Tool (PHAST) and similar tools for other industrial systems in the early 2000s. It has been used extensively in the Save Energy Now Program’s Energy Savings Assessments and the Better Plants Program’s In-Plant Trainings. Since the initial development of the legacy tools, both computer operating systems and software development have evolved significantly. Thus, DOE has invested in the modernization of PHAST and other legacy software tools to create the Manufacturing Energy Assessment Software for Utility Reduction (MEASUR) tool suite. MEASUR offers a collection of software tools that can aid manufacturing facilities in improving the efficiency of energy systems and equipment (specifically pumps, fans, steam, and process heating) and in conducting “Energy Treasure Hunts”. Eventually, the tool will also add compressed air and process cooling systems. The Process Heating Assessment (PHA) module of MEASUR is an upgrade of the PHAST tool. PHA provides the means to model fuel-fired, steam-based, and electric process heating systems, covering process heating for most industrial plants in manufacturing sector. It also includes several key upgrades, including the ability to consider multi-component charge loads and account for several different areas of energy losses. The new tool includes a comprehensive flue gas calculator to quantify available heat and heat loss for various gaseous, liquid, and solid fuels and new heat loss calculators. It generates a report and a dynamic Sankey diagram to show the energy consumption in various areas of energy use. MEASUR has significantly improved the user experience by adopting a modern software design. This paper details the structure and workflow of PHA and presents a real-world case study to demonstrate energy savings quantification and MEASUR’s outstanding reporting capabilities.

Nimbalkar, Sachin U.↗

Hydrogen-rich syngas production from the steam co-gasification of low-density polyethylene and coal refuse

Gasification provides a promising pathway for transforming waste materials into valuable products, such as fuels and chemicals. Here, this study investigates the steam co-gasification of low-density polyethylene (LDPE) and compressed thickener underflow, representative of coal refuse (CR), in a drop tube reactor. The effects of feed blend ratio (0–100 wt% LDPE) and temperature (800–1000 °C) on syngas composition, tar formation, and process efficiency are examined. The high volatility of LDPE makes it more reactive than CR but also promotes the formation of 2–7 ring aromatic tars. Increasing temperature improves carbon conversion efficiency (CCE), cold gas efficiency (CGE), and syngas yield, although the lower heating value (LHV) of syngas decreases. Hydrogen is the dominant gas product, reaching 59 vol% with the H 2 /CO molar ratio ranging from 2.27 to 4.74. Synergistic effects from alkali and alkali earth metals (AAEMs), particularly K and Ca, in CR ash enhance syngas yield by catalyzing char gasification and tar cracking. Hematite (Fe 2 O 3 ) and ash from sub-bituminous/bituminous coals are explored as tar reforming catalysts. Fe 2 O 3 achieves 100 % tar reforming efficiency, while coal ash, with a lower Fe 2 O 3 content (15 wt%), is less effective at cracking polycyclic aromatic hydrocarbons, particularly naphthalene. These findings demonstrate the flexibility of co-gasification, allowing precise tuning of syngas characteristics for specific downstream applications. Further optimization of waste-derived catalysts could enhance the economic viability of gasification in waste-to-energy processes.

01 COAL, LIGNITE, AND PEAT↗