Search NASA⌕ Search

SEARCH · Search NASA

Results for “Stilbene”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Deuterated stilbene (stilbene-d 12 ): An improved detector for fast neutrons

Here, we have developed and evaluated two prototype fast neutron deuterated-stilbene scintillators. The largest scintillator is hexagonal in shape with volume 32 cm 3 , comprised of deuterated crystalline trans-stilbene (stilbene-d 12 ). These samples were grown using a solution-based crystal growing method developed at Lawrence Livermore Laboratory to grow conventional 1 H-based stilbene scintillator crystals. The stilbene-d 12 prototype detectors show excellent neutron/gamma discrimination, noticeably better than 1 H-stilbene, and appear to have less asymmetry in the response to neutrons incident from different directions. Finally, like other deuterated scintillators, the stilbene-d 12 detectors in many applications can provide incident neutron energy spectra, without time of flight, by suitably unfolding the neutron light-output spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural and kinetic analysis of the unnatural fusion protein 4-coumaroyl-CoA ligase::stilbene synthase

To increase the biochemical efficiency of biosynthetic systems, metabolic engineers have explored different approaches for organizing enzymes, including the generation of unnatural fusion proteins. Previous work aimed at improving the biosynthesis of resveratrol, a stilbene associated a range of health-promoting activities, in yeast used an unnatural engineered fusion protein of Arabidopsis thaliana (thale cress) 4-coumaroyl-CoA ligase (At4CL1) and Vitis vinifera (grape) stilbene synthase (VvSTS) to increase resveratrol levels 15-fold relative to yeast expressing the individual enzymes. Here we present the crystallographic and biochemical analysis of the 4CL::STS fusion protein. Determination of the X-ray crystal structure of 4CL::STS provides the first molecular view of an artificial didomain adenylation/ketosynthase fusion protein. Comparison of the steady-state kinetic properties of At4CL1, VvSTS, and 4CL::STS demonstrates that the fusion protein improves catalytic efficiency of either reaction less than 3-fold. Structural and kinetic analysis suggests that colocalization of the two enzyme active sites within 70 {angstrom} of each other provides the basis for enhanced in vivo synthesis of resveratrol.

59 BASIC BIOLOGICAL SCIENCES↗

Anisotropic neutron response of trans-stilbene and impact on a handheld dual particle imager

Here this manuscript details measurements of the anisotropic light-output response of trans-stilbene, henceforth referred to as stilbene, along the three primary crystal planes and analyzes how this anisotropic response impacts neutron image reconstruction in a handheld dual particle imager (H2DPI). A prototype H2DPI composed of stilbene pillars (6 x 6 x 50 mm 3 ) coupled to silicon photomultipliers was built and is capable of imaging both fast neutrons and gamma rays from kilogram quantities of special nuclear material. Stilbene was chosen as the scintillating medium for the imager because of its pulse shape discrimination capability, time resolution and relatively high light output. A drawback to using stilbene, however, is the anisotropic response. A recoiling proton from a neutron elastic-scattering event in stilbene will yield different amounts of scintillation light depending on the direction of the recoiling proton with respect to the crystal lattice. This manuscript analyzes how this anisotropic response impacts neutron image reconstruction in 4π. The light output in the three primary crystal planes of stilbene were independently measured 6–7 times for proton recoil energies ranging from 0.5–5.0 MeV using a quasi-monoenergetic time-of-flight neutron source. The measured light-output data in the three crystal planes were fit with a semi-empirical function based on Birks’ formula. These fits were used to reconstruct the location of a 252 Cf source in front of the imager (0°, -0.8°), to the left of the imager (-90°, -0.8°) and directly above the imager (0°, 90°) to determine if it is necessary to apply the directionally-dependent response of stilbene to accurately reconstruct source locations. A bootstrapping technique was applied to the measured data sets to produce 1000 images composed of 2000 cone projections for each source location and each measured light-output curve. List-mode maximum likelihood expectation maximization was applied to each image; the highest pixel location and the full width at half maximum (FWHM) were then recorded. The average and standard deviations of these parameters were taken for each set of images. The maximum difference in the average azimuthal pixel location when varying between the appropriate and incorrect light-output curves for the source locations at (0°, -0.8°) and (-90°, -0.8°) were respectively found to be 1.85 ± 1.39° and 2.03 ± 1.78°. All other pixel locations and FWHMs were within a single standard deviation of uncertainty. Taken together, the anisotropic response of stilbene has negligible impact on the neutron image reconstruction capability of the H2DPI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantification of the light output anistropy in deuterated stilbene

Deuterated stilbene is an organic scintillator that is a desirable material for fast neutron spectroscopy using spectrum unfolding techniques without requiring time-of-flight information. Due to the crystal structure of the material, some anisotropy of the light output exists, which is dependent on the direction of heavy charged particle recoil relative to the crystal structure. The anisotropy of trans-stilbene (hereafter referred to as stilbene) has been well characterized in previous work, but for deuterated stilbene, the anisotropy has only been partially characterized along the a and b crystal axes, while the artificial c' axis, which shows the largest anisotropy in stilbene, has not been characterized until this publication. Here, in this work, two deuterated stilbene crystals were characterized with neutron energies up to 35 MeV at the Los Alamos Neutron Science Center. For one of the crystals, the response is characterized along the a, b, and c' axes. This characterization shows a distinct anisotropy along the axes in deuterated stilbene, which is very similar to that found in regular stilbene, such that the a axis is the brightest, while the b' and c' axes are approximately 3% and 20%–35% lower relative to the a axis.

36 MATERIALS SCIENCE↗

Nonadiabatic Dynamics of Photoexcited cis-Stilbene Using Ab Initio Multiple Spawning

The photochemistry of cis-stilbene proceeds through two pathways: cis-trans isomerization and ring closure to 4a,4b-dihydrophenanthrene (DHP). Despite serving for many decades as a model system for photoisomerization, the photodynamics of cis-stilbene is still not fully understood. In this work, we use ab initio multiple spawning on a SA-2-CASSCF(2,2) potential energy surface to simulate the nonadiabatic dynamics of isolated cis-stilbene. We find the cyclization (to DHP and cis-stilbene) and isomerization (to trans- and cis-stilbene) reaction coordinates to be orthogonal; branching between the two pathways is determined on the S1 excited state within 150 fs of photoexcitation. Furthermore ,trajectory basis functions (TBFs) undergoing cyclization decay rapidly to the ground state in 250 fs, while TBFs moving along the isomerization coordinate remain on the excited state longer, with the majority decaying between 300 and 500 fs. We observe three avoided crossing regions in the dynamics: two along the isomerization coordinate (displaying pyramidalization and migration of an ethylenic hydrogen or phenyl group), and one DHP-like conical intersection along the cyclization coordinate. The isomeric form of the vibrationally hot photoproducts (as determined by measurement 2 ps after photoexcitation) is determined within less than 50 fs of decay to the ground state mediated by passage through a conical intersection. Excess vibrational energy of ground state cis- and trans-stilbene is channelled into phenyl torsions (with mostly opposing directionality). Finally, our simulations are validated by direct comparison to experiment for the absorption spectrum, branching ratio of the three photoproducts (44:52:4 cis-stilbene:trans-stilbene:DHP), and excited state lifetime (520 ± 40 fs).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strong, Nonresonant Radiation Enhances Cis–Trans Photoisomerization of Stilbene in Solution

Previously, it has been demonstrated that external electric fields may be used to exert control over chemical reactivity. In this paper, the impact of a strong, nonresonant IR field (1064 nm) on the photoisomerization of cis-stilbene is investigated in cyclohexane solution. The design of a suitable reaction vessel for characterization of this effect is presented. The electric field supplied by the pulsed, near-IR radiation (ε 1 = 4.5 × 10 7 V/cm) enhances the cis → trans photoisomerization yield at the red edge of the absorption spectrum (wavelengths between 337 and 340 nm). Within the microliter focal volume, up to 75% of all cis-stilbene molecules undergo isomerization to trans-stilbene in the strong electric-field environment, indicating a significant increase relative to the 35% yield of trans-stilbene under field-free conditions. This result correlates with a 1–3% enhancement in the trans-stilbene concentration throughout the bulk solution. Theoretical analysis suggests that the observed change is the result of dynamic Stark shifting of the ground and first excited states, leading to a significant redshift in cis-stilbene’s absorption spectrum. The predicted increase in the absorption cross section in this range of excitation wavelengths is qualitatively consistent with the experimental increase in trans-stilbene production.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transcriptomic Analysis Reveals Novel Regulators of the Scots Pine Stilbene Pathway

Stilbenes accumulate in Scots pine heartwood where they have important roles in protecting wood from decaying fungi. They are also part of active defense responses, and their production is induced by different (a)biotic stressors. The specific transcriptional regulators as well as the enzyme responsible for activating the stilbene precursor cinnamate in the pathway are still unknown. UV-C radiation was the first discovered artificial stress activator of the pathway. Here, we describe a large-scale transcriptomic analysis of pine needles in response to UV-C and treatment with translational inhibitors, both activating the transcription of stilbene pathway genes. We used the data to identify putative candidates for the missing CoA ligase and for pathway regulators. We further showed that the pathway is transcriptionally activated by phosphatase inhibitor, ethylene and jasmonate treatments, as in grapevine, and that the stilbene synthase promoter retains its inducibility in some of the tested conditions in Arabidopsis, a species that normally does not synthesize stilbenes. Shared features between gymnosperm and angiosperm regulation and partially retained inducibility in Arabidopsis suggest that pathway regulation occurs not only via ancient stress-response pathway(s) but also via species-specific regulators. Understanding which genes control the biosynthesis of stilbenes in Scots pine aids breeding of more resistant trees.

4-Coumarate-CoA ligase↗

Characterization of stilbene-d 12 for neutron spectroscopy without time of flight

In this work, we have experimentally characterized the light-output response of a deuterated trans-stilbene (stilbene-d 12 ) crystal to quasi-monoenergetic neutrons in the 0.8 to 4.4 MeV energy range. These data allowed us to perform neutron spectroscopy measurements of a DT 14.1 MeV source and a 239 PuBe source by unfolding the impinging neutron spectrum from the measured light-output response. The stilbene-d 12 outperforms a 1 H-stilbene of similar size when comparing the shape of the unfolded spectra and the reference ones. These results confirm the viability of non-hygroscopic stilbene-d 12 crystal for direct neutron spectroscopy without need for time-of-flight measurements. This capability makes stilbene-d 12 a well suited detector for fast-neutron spectroscopy in many applications including nuclear reaction studies, radiation protection, nuclear non-proliferation, and space travel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prototype Stilbene Neutron Collar II

A neutron collar using stilbene organic scintillator cells for fast neutron counting is described for the assay of fresh low enriched uranium (LEU) fuel assemblies. The prototype stilbene collar has a form factor similar to standard He-3 based collars and uses an AmLi interrogation neutron source. This report describes the simulation, using a custom LLNL developed MCNPX, of list mode neutron correlation data on various fuel assemblies. Some of these fuel assemblies have neutron absorbers (burnable Gd poisons) and partial defect s (DU, Fe, Pb pins). Calibration curves (doubles vs 235 U linear mass density) are presented for fast (with Cd lining) mode of operation. The modeling incorporates LLNL developed neutron crosstalk correction algorithms and stilbene light output detector response quench function. Pileup issues are addressed using the LLNL code GamGen / RadSrc to estimate the flux of alpha decay gammas from the fuel assemblies on the stilbene cells with and without Pb shielding. One panel of the prototype collar using 10 high-efficiency 4”x2” stilbene cells from Inrad Optics, using LLNL developed technology, has been constructed and calibrated for optimal PSD and data acquisition electronics. Several sources (AmLi, AmBe, Cf, DD, and DT) have been measured with the single panel and the measured data is consistent with the modeling. A novel part of our work was to determine the light output (LO) quench function for the Inrad 4” x 2” stilbene crystals through a LLNL-MCNPX simulation based optimized fitting of the measured LO data.

42 ENGINEERING↗

Neutron detection in a high-gamma field using solution-grown stilbene

We present that a solution-based technique for growing large-volume stilbene scintillators was developed in 2013; crystals up to diameters of 10 cm, or larger, have been grown while preserving excellent pulse shape discrimination (PSD) properties. The goal of this study is to evaluate the PSD capabilities of 5.08 by 5.08-cm stilbene crystals grown by Lawrence Livermore National Laboratory and Inrad Optics when exposed to a 1000 to 1 gamma ray-neutron ratio and operating at a 100-kHz count rate. Results were compared to an equivalent EJ-309 liquid scintillation detector. 252 Cf neutron pulses were recorded in two experiments where 60 Co and 137 Cs sources created the high-gamma field. The high count rate created numerous double pulses that were cleaned using fractional and template approaches designed to remove double pulses while preserving neutron counts. PSD was performed at a threshold of 42 keVee (440-keV proton) for stilbene and 60 keVee (610-keV proton) for EJ-309 liquid. The lower threshold in stilbene resulted in a neutron intrinsic efficiency of approximately 14.5%, 10% higher than EJ-309 liquid, for bare 252 Cf and 13% for 252 Cf in the high-gamma field. Despite the lower threshold, the gamma misclassification rate in stilbene was approximately 3×10 $-$6 , nearly a factor-of-five lower than what we found with the EJ-309 liquid.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stilbene cell development to improve radioxenon detection

A prototype stilbene beta cell has been designed, manufactured, tested, and compared to a plastic scintillator beta cell used for nuclear explosion monitoring of radioxenon. Measurements of the four isotopes of interest show similar responses for both the plastic scintillator and stilbene cell. However, we show that the stilbene cell exhibits minimal memory effect (0.043%), a capability that is of interest in nuclear explosion monitoring because it improves detection sensitivity, allowing for decreased time between measurements. The resolution of the stilbene cell is improved slightly (2.2 keV at 129 keV) when compared to the plastic scintillator cell. The efficiency of the stilbene cell is lower than that of the plastic by an average 15%. These results suggest that an improvement in light collection are needed. Pulse shape discrimination analysis decreases the minimum detectable concentration by 1%. The use of this geometry allows for a simple replacement of the plastic cells currently used in the field versus a complete overhaul of the existing radioxenon monitoring stations.

Sivels, Ciara B.↗

Characterization of the scintillation anisotropy in crystalline stilbene scintillator detectors

This study reports a series of measurements that characterize the directional dependence of the scintillation response of crystalline melt-grown and solution-grown trans-stilbene to incident DT and DD neutrons. These measurements give the amplitude and pulse shape dependence on the proton recoil direction over one hemisphere of the crystal, confirming and extending previous results in the literature for melt-grown stilbene and providing the first measurements for solution-grown stilbene. In similar measurements of liquid and plastic detectors, no directional dependence was observed, confirming the hypothesis that the anisotropy in stilbene and other organic crystal scintillators is a result of internal effects due to the molecular or crystal structure and not an external effect on the measurement system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prototype Stilbene Neutron Collar

A neutron collar using stilbene organic scintillator cells for fast neutron counting is described for the assay of fresh low enriched uranium (LEU) fuel assemblies. The prototype stilbene collar has a form factor similar to standard He-3 based collars and uses an AmLi interrogation neutron source. This report describes the simulation of list mode neutron correlation data on various fuel assemblies including some with neutron absorbers (burnable Gd poisons). Calibration curves (doubles vs 235 U linear mass density) are presented for both thermal and fast (with Cd lining) modes of operation. It is shown that the stilbene collar meets or exceeds the current capabilities of He-3 based neutron collars. A self-consistent assay methodology, uniquely suited to the stilbene collar, using triples is described which complements traditional assay based on doubles calibration curves.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Solution growth of a deuterated trans -stilbene crystal for fast neutron detection

The paper reports results on growth and characterization of the first deuterated analog of the trans -stilbene crystal. The high optical quality stilbene-d12 single crystal was grown by application of the solution technique using specially synthesized raw material and an aromatic solvent (anisole). Optical, physical, and scintillation properties of the new material are compared to those of the regular trans -stilbene crystal. In conclusion, the new deuterated material is promising for use in fast neutron spectroscopy without the need for time-of-flight measurements.

36 MATERIALS SCIENCE↗

A stilbene - CdZnTe based radioxenon detection system

Atmospheric monitoring of radioxenon is one of the most widely used methods by the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) to detect elevated levels of 131m Xe, 133/133m Xe, and 135 Xe. The ratios of these radionuclides help discriminate between peaceful use of nuclear technology and nuclear weapon explosions. Radioxenon detection systems often use plastic scintillators in the capacity of an electron detector and a gas cell, plastic gas cells are responsible for introducing high memory effect in these systems. This work presents the design of a new detection system for radioxenon monitoring that utilizes silicon photomultipliers, a stilbene gas cell, and a CdZnTe detector. This detector was evaluated using xenon radioisotope samples produced in the TRIGA reactor at Oregon State University. Here, a 48-h background was collected and calculations of the Minimum Detectable Concentration (MDC) were carried out using the Region of Interest (ROI) approach. An MDC of less than 1 mBq/m 3 was obtained for 131m Xe, 133 Xe, and 133m Xe in accordance with the sensitivity limits set by the CTBTO and performs respectably when compared to state-of-the-art radioxenon detection systems. Using 131m Xe, this study indicates that the stilbene gas cell exhibits a memory effect of 0.045 ±0.017%, this is almost a two-order magnitude improvement compared to plastic scintillators. The main purpose of this work is to explore the use of new stilbene detection media for radioxenon application and addressing the problem of memory effect.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Comparison of pulse shape discrimination performance of stilbene and liquid scintillator under high count-rate active interrogation conditions

Here, we compare the pulse-shape-discrimination performance of a large Stilbene detector, manufactured at the Lawrence Livermore National Laboratory, to a similarly sized liquid scintillator, made by Eljen Technologies, Inc. (type EJ309), under various high-count-rate scenarios, such as can be expected during Active Interrogation of objects using an electric neutron generator for detecting the presence of Special Nuclear Materials and contraband. Pulse Shape Discrimination (PSD) is performed with an extension of previously described wavelet and event fitting algorithms, which are also used to reject pileup events and to correct the energy calibration for event signals clipped during digitization. We find that strong PSD and pileup rejection cuts are required to function in this high-count-rate environment. Whereas the Stilbene detector has intrinsically better pulse-shape discrimination performance, the pulses of events from the liquid scintillator are somewhat narrower, reducing pileup. We use an event fitting cut that provides simultaneous PSD identification and pileup rejection. When applying the same cut to data taken with both detectors, we find that Stilbene has higher event use efficiency by about a factor of two and retains a better gamma rejection ratio compared to EJ309.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-precision characterization of the neutron light output of stilbene along the directions of maximum and minimum response

The scintillation light output response of stilbene crystals has been calculated for protons recoiling along the a, b, and c' crystalline axes with energies between 1.3 and 10 MeV using neutrons produced with the tandem Van de Graaff accelerator at Triangle Universities Nuclear Laboratory. The proton recoil energy and direction were measured using the coincident detection of neutrons between a stilbene scintillator and an array of EJ-309 liquid scintillators spanning arranged neutron recoil angles. The maximum light output was discovered to coincide with proton recoils along the a-axis, in disagreement with other published measurements, which reported the b-axis as the direction of the maximum light output. Additional measurements were conducted using two different stilbene crystals to confirm these results: a second measurement using the coincident detection of neutrons; measurements of neutron full energy deposition events along the a and b axes; and measurements of the count rate for 252 Cf neutrons traveling along the a and b axes directions. All measurements found that recoils along the a-axis produce the maximum light output.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗