Search NASA⌕ Search

SEARCH · Search NASA

Results for “Storage Capabilities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Plasma enhanced multistate storage capability of single ZnO nanowire based memory

Multiple-state storage (MSS) is common for resistive random access memory, but the effects of plasma treatment on the MSS and the switching properties have been scarcely investigated. We have demonstrated a stable four-state storage capability of single zinc oxide nanowire (ZnO NW) treated by argon plasma. The electrical switching is attributed to the electron trapping and detrapping from the oxygen vacancies (V{sub o}s). The MSS relates to the electrical-thermal induced distribution of the V{sub o}s which determines electron transport behavior to show different resistance states. Additionally, programming (set and reset) voltages decrease with plasma treatment due to the thickness modulation of the interface barrier.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Virtual storage capability of residential buildings for sustainable smart city via model-based predictive control

This paper evaluates the virtual storage capability of a residential air-conditioning (AC) system by utilizing the building mass as a thermal storage to enable sustainable cities through model-based predictive control (MPC). The control-oriented building model was developed with a grey-box model structure based on the experimental data to predict the indoor air temperature. Based on the model, the operation cost-saving potential of the MPC was investigated in a single house with different comfort levels, electricity prices, and prediction horizons. The cost-saving of the MPC was approximately 10.6 % compared to the conventional control. The MPC was expanded to a residential building cluster considering the peak demand charge. In an hourly shedding and load-up scenario, the performances of the MPC and the heuristic prior-based control (PBC) are promising. When shedding was enforced all day, the peak demand saving of the MPC was 36~38 %, whereas that of the PBC was 25.7 % compared to the baseline. In addition, the monthly electricity bill, including the operation and peak demand cost, was investigated with different demand charge rates and weather conditions. The total saving decreased with a low demand charge rate and hot conditions, and the operation cost saving was compromised with more aggressive demand shedding.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multifunctional Heat Pump with Energy Storage Capability

Replacing gas furnaces with heat pumps on a large scale can pose challenges to the electrical grid. It will significantly increase the demand, strain the electrical grid, especially during peak usage times. To ensure that heat pumps contribute to reducing emissions, it's essential to increase the share of renewable energy in the grid. However, the supply of renewable energy is unstable. Large scale of electrification must address the concern of grid resilience to meet necessary heating/cooling demands and shift peak electric load. All these require future heat pumps having energy storage capability. These systems can store excess energy during low-demand periods and release it during high-demand periods, reducing stress on the grid. This paper will introduce an innovative configuration, control, and laboratory investigations of a multifunctional packaged heat pump. In addition to the original indoor and outdoor air coils, the heat pump has a parallel hydronic loop with a brazed plate heat exchanger (BHP). The hydronic loop circulates hot/chilled water to store heating/cooling energy in phase change material (PCM). It is capable of space cooling, space heating, cooling energy storage/defrosting, water heating/heating energy storage with outdoor air source or indoor air source, and cooling/heating energy free discharge. The laboratory studies and breadboard unit are presented. Additionally, building energy simulation demonstrates utility cost reduction potential via charging PCM panels/ceilings during off-peak hours and releasing the energy during peak hours to mitigate the peak power consumption.

Shen, Bo↗

Methane storage capabilities of diamond analogues

Methane can be an alternative fuel for vehicular usage provided that new porous materials are developed for its efficient adsorption-based storage. Herein, we search for materials for this application within the family of diamond analogues. We used density functional theory to investigate structures in which tetrahedral C atoms of diamond are separated by-CC-or-BN-groups, as well as ones involving substitution of tetrahedral C atoms with Si and Ge atoms. The adsorptive and diffusive properties of methane are studied using classical molecular simulations. Our results suggest that the all-carbon structure has the highest volumetric methane uptake of 280 VSTP/V at p = 35 bar and T = 298 K. However, it suffers from limited methane diffusion. Alternatively, the considered Si and Ge-containing analogies have fast diffusive properties but their adsorption is lower, ca. 172-179 VSTP/V, at the same conditions.

Haranczyk, M↗

Revolutionizing Lithium Storage Capabilities in TiO 2 by Expanding the Redox Range

TiO 2 is a widely recognized intercalation anode material for lithium-ion batteries (LIBs), yet its practical capacity is kinetically constrained due to sluggish lithium-ion diffusion, leading to a lithiation number of less than 1.0 Li + (336 mAh g -1 ). Here, the growth of TiO 2 crystallites is restrained by integrating Si into the TiO 2 framework, thereby enhancing the charge transfer and creating additional active sites potentially residing at grain boundaries for Li + storage. This strategy is corroborated by the expanded redox range of Ti, as thoroughly demonstrated via synchrotron radiation-based X-ray spectroscopy and Cs-corrected electron microscopy. Consequently, when deployed for lithium storage, the tailored material achieves an extraordinarily high reversible capacity of 559 mAh g -1 , 116% of the theoretical maximum of 483 mAh g -1 calculated based on all active species, while simultaneously retaining superior rate capability and robust cycling stability. Further, this work offers fresh perspectives on the revitalization of traditional electrode materials to achieve enhanced capacities.

25 ENERGY STORAGE↗

Pulse shaping and energy storage capabilities of angularly multiplexed KrF laser fusion drivers

This paper describes a rep-rated multibeam KrF laser driver design for the 500 kJ Inertial Fusion test Facility (FTF) recently proposed by NRL, then models its optical pulse shaping capabilities using the ORESTES laser kinetics code. It describes a stable and reliable iteration technique for calculating the required precompensated input pulse shape that will achieve the desired output shape, even when the amplifiers are heavily saturated. It also describes how this precompensation technique could be experimentally implemented in real time on a reprated laser system. The simulations show that this multibeam system can achieve a high fidelity pulse shaping capability, even for a high gain shock ignition pulse whose final spike requires output intensities much higher than the approx4 MW/cm{sup 2} saturation levels associated with quasi-cw operation; i.e., they show that KrF can act as a storage medium even for pulsewidths of approx1 ns. For the chosen pulse, which gives a predicted fusion energy gain of approx120, the simulations predict the FTF can deliver a total on-target energy of 428 kJ, a peak spike power of 385 TW, and amplified spontaneous emission prepulse contrast ratios I{sub ASE}/I<3x10{sup -7} in intensity and F{sub ASE}/F<1.5x10{sup -5} in fluence. Finally, the paper proposes a front-end pulse shaping technique that combines an optical Kerr gate with cw 248 nm light and a 1 mum control beam shaped by advanced fiber optic technology, such as the one used in the National Ignition Facility (NIF) laser.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced lithium storage capability of FeF 3 ·0.33H 2 O single crystal with active insertion site exposed

Iron fluoride cathode for lithium batteries intrigues researchers for decades due to high capacity and low cost, but suffers from poor electronic and ionic conductivity. Hierarchical micro/nano construction with preferred orientation growth can shorten ion diffusion pathway and facilitate electron transportation without inducing side reactions. FeF 3 ·0.33H 2 O hierarchical microspheres self-assembled by octagonal single crystal slices are prepared. Benefiting from the artful structure, SAED and XRD characterizations confirm that the octagonal single crystal slices provides more lithium ions intercalation positions (4c sites). Electrochemical tests demonstrate that the well designed FeF 3 ·0.33H 2 O single crystal (FFH-S) delivers 30 mAh g -1 higher capacity (172 mAh g -1 at 0.1C) than the common FeF 3 ·0.33H 2 O polycrystal (FFH-P). In-situ XRD combined with theoretic calculation elucidate the difference in lithium storage capacity. Instructive argument that single crystal octagon slices with [110] oriented growth provide more active sites for lithium ions intercalation contributes to the preparation of high performance iron fluoride cathode materials for rechargeable battery.

25 ENERGY STORAGE↗

DEMONSTRATION OF LONG-TERM STORAGE CAPABILITY FOR SPENT NUCLEAR FUEL IN L BASIN

The U.S. Department of Energy decisions for the ultimate disposition of its inventory of used nuclear fuel presently in, and to be received and stored in, the L Basin at the Savannah River Site, and schedule for project execution have not been established. A logical decision timeframe for the DOE is following the review of the overall options for fuel management and disposition by the Blue Ribbon Commission on America's Nuclear Future (BRC). The focus of the BRC review is commercial fuel; however, the BRC has included the DOE fuel inventory in their review. Even though the final report by the BRC to the U.S. Department of Energy is expected in January 2012, no timetable has been established for decisions by the U.S. Department of Energy on alternatives selection. Furthermore, with the imminent lay-up and potential closure of H-canyon, no ready path for fuel disposition would be available, and new technologies and/or facilities would need to be established. The fuel inventory in wet storage in the 3.375 million gallon L Basin is primarily aluminum-clad, aluminum-based fuel of the Materials Test Reactor equivalent design. An inventory of non-aluminum-clad fuel of various designs is also stored in L Basin. Safe storage of fuel in wet storage mandates several high-level 'safety functions' that would be provided by the Structures, Systems, and Components (SSCs) of the storage system. A large inventory of aluminum-clad, aluminum-based spent nuclear fuel, and other nonaluminum fuel owned by the U.S. Department of Energy is in wet storage in L Basin at the Savannah River Site. An evaluation of the present condition of the fuel, and the Structures, Systems, or Components (SSCs) necessary for its wet storage, and the present programs and storage practices for fuel management have been performed. Activities necessary to validate the technical bases for, and verify the condition of the fuel and the SSCs under long-term wet storage have also been identified. The overall conclusion is that the fuel can be stored in L Basin, meeting general safety functions for fuel storage, for an additional 50 years and possibly beyond contingent upon continuation of existing fuel management activities and several augmented program activities. It is concluded that the technical bases and well-founded technologies have been established to store spent nuclear fuel in the L Basin. Methodologies to evaluate the fuel condition and characteristics, and systems to prepare fuel, isolate damaged fuel, and maintain water quality storage conditions have been established. Basin structural analyses have been performed against present NPH criteria. The aluminum fuel storage experience to date, supported by the understanding of the effects of environmental variables on materials performance, demonstrates that storage systems that minimize degradation and provide full retrievability of the fuel up to and greater than 50 additional years will require maintaining the present management programs, and with the recommended augmented/additional activities in this report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Lithium storage capability of CuGeO{sub 3} nanorods

Highlights: ► We synthesized nanosized CuGeO{sub 3} by a facial hydrothermal method for Li battery. ► A high capacity of 690 mAh g{sup −1} at 50 cycles is achieved. ► The capacity is remarkably higher than that of the GeO{sub 2} electrode. ► The nanosized CuGeO{sub 3} also shows good cyclability. -- Abstract: Copper metagermanate (CuGeO{sub 3}) nanorods were synthesized through a low temperature hydrothermal method at 180 °C. The as-synthesized CuGeO{sub 3} nanorods show a well crystallined nanostructure with diameters in the range from 40 to 70 nm, and a length from 250 to 350 nm. Electrochemical measurements demonstrate that the CuGeO{sub 3} nanorods exhibit a first charge capacity of 924 mAh g{sup −1} and 690 mAh g{sup −1} after 50 cycles, which is remarkably improved than the pure nanosize GeO{sub 2} electrode. This investigation indicates that CuGeO{sub 3} nanorods could be utilized as a high capacity anode material in lithium-ion batteries by reducing particle size and metal oxide addition. The lithium storage mechanisms for the improved capacity retention were also studied.

36 MATERIALS SCIENCE↗

Dielectric properties and energy storage capability of antiferroelectric Pb{sub 0.92}La{sub 0.08}Ti{sub 0.05}O{sub 3} film-on-foil capacitors.

Antiferroelectric (AFE) Pb{sub 0.92}La{sub 0.08}Zr{sub 0.95}Ti{sub 0.05}O{sub 3} (PLZT) films were grown on nickel foils with lanthanum nickel oxide buffer by chemical solution deposition. We observed field-induced AFE-to-ferroelectric (FE) phase transition. The electric field for the AFE-to-FE phase transition (E{sub AF} {approx} 270 kV/cm) and that for the reverse phase transition (E{sub FA} {approx} 230 kV/cm) were measured at room temperature on samples with PLZT films of {approx}1-{micro}m thickness. Relative permittivity of {approx}560 and dielectric loss of <0.05 were measured near zero DC bias field. Hysteresis loop analysis showed that energy densities of {approx}53 and 37 J/cm3 can be stored and recovered from the film-on-foil capacitors at 25 and 150 C, respectively. Highly accelerated life tests were conducted. The projected mean time to failure is >5000 h when the capacitors are operated at room temperature with an applied field of {approx}300 kV/cm.

36 MATERIALS SCIENCE↗

Environmental Assessment for the Above Ground Storage Capability at the Waste Isolation Pilot Plant Draft

The Waste Isolation Pilot Plant (WIPP) is the nation’s only approved repository for the disposal of defense related/defense generated transuranic (TRU) and mixed hazardous TRU waste (henceforth called TRU waste). The mission of the WIPP Project is to realize the safe disposal of TRU waste from TRU waste generator sites in the Department of Energy waste complex. The WIPP Project was authorized by Title II, Section 213(a) of Public Law 96-164 (U. S. Congress 1979). Congress designated the WIPP facility “for the express purpose of providing a research and development facility to demonstrate the safe disposal of radioactive wastes resulting from the defense activities and programs of the United States exempted from regulation by the Nuclear Regulatory Commission (NRC).” The WIPP facility is operated by the U. S. Department of Energy (DOE). Transuranic waste that is disposed in the WIPP facility is defined by Section 2(18) the WIPP Land Withdrawal Act of 1992 (LWA) (U. S. Congress, 1992) as: “waste containing more than 100 nanocuries of alpha-emitting transuranic isotopes per gram of waste, with half-lives greater than 20 years, except for: (A) high-level radioactive waste; (B) waste that the Secretary has determined, with the concurrence of the Administrator, does not need the degree of isolation required by the disposal regulations; or (C) waste that the NRC has approved for disposal on a case-by-case basis in accordance with part 61 of title 10, Code of Federal Regulations (CFR).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Review of Sandia Energy Storage Research Capabilities and Opportunities (2020 to 2030)

Large-scale integration of energy storage on the electric grid will be essential to enabling greater penetration of intermittent renewable energy sources, modernizing the grid for increased flexibility security, reliability, and resilience, and enabling cleaner forms of transportation. The purpose of this report is to summarize Sandia's research and capabilities in energy storage and to provide a preliminary roadmap for future efforts in this area that can address the ongoing program needs of DOE and the nation. Mission and vision statements are first presented followed by an overview of the organizational structure at Sandia that provides support and activities in energy storage. Then, a summary of Sandia's energy storage capabilities is presented by technology, including battery storage and materials, power conversion and electronics, subsurface-based energy storage, thermal/thermochemical energy storage, hydrogen storage, data analytics/systems optimization/controls, safety of energy storage systems, and testing/demonstrations/model validation. A summary of identified gaps and needs is also presented for each technology and capability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multisource Mobile Transfer Learning Algorithm Based on Dynamic Model Compression

With the development of the Internet of Things, the application of computer vision on mobile phones is becoming more and more extensive and people have higher and higher requirements for the timeliness of the recognition results returned and the processing capabilities of the mobile phone for image recognition. However, the processing capability and storage capability of the user terminal equipment cannot meet the needs of identifying and storing a large number of pictures, and the data transmission process will cause high energy consumption of the terminal equipment. At the same time, multisource deep transfer learning has outstanding performance in computer vision and image classification. However, due to the huge amount of calculation of the deep network model, it is impossible to use the existing excellent network model to realize image recognition and classification on the mobile terminal. In order to solve the abovementioned problems, we propose a multisource mobile transfer learning algorithm based on dynamic model compression, this algorithm considers the realization of multisource transfer learning computing in the case of multiple mobile device computing source domains, and the method also guarantees data privacy and security for each device (origin domain). Meanwhile, extensive experiments show that our method can achieve remarkable results in popular image classification datasets.

Gao, Peng↗

Numerical investigation of a joint approach to thermal energy storage and compressed air energy storage in aquifers

Different from conventional compressed air energy storage (CAES) systems, the advanced adiabatic compressed air energy storage (AA-CAES) system can store the compression heat which can be used to reheat air during the electricity generation stage. Thus, AA-CAES system can achieve a higher energy storage efficiency. Similar to the AA-CAES system, a compressed air energy storage in aquifers (CAESA) system, which is integrated with an aquifer thermal energy storage (ATES) could possibly achieve the same objective. In order to investigate the impact of ATES on the performance of CAESA, different injection air temperature schemes are designed and analyzed by using numerical simulations. Key parameters relative to energy recovery efficiencies of the different injection schemes, such as pressure distribution and temperature variation within the aquifers as well as energy flow rate in the injection well, are also investigated in this study. The simulations show that, although different injection schemes have a similar overall energy recovery efficiency (~97%) as well as a thermal energy recovery efficiency (~79.2%), the higher injection air temperature has a higher energy storage capability. Our results show the total energy storage for the injection air temperature at 80 °C is about 10% greater than the base model scheme at 40 °C. Sensitivity analysis reveal that permeability of the reservoir boundary could have significant impact on the system performance. However, other hydrodynamic and thermodynamic properties, such as the storage reservoir permeability, thermal conductivity, rock grain specific heat and rock grain density, have little impact on storage capability and the energy flow rate. Our study suggests that the combination of ATES and CAESA can help keep the high efficiency of energy storage so as to make CAESA system more efficiency.

25 ENERGY STORAGE↗

SRS K-AREA MATERIAL STORAGE - EXPANDING CAPABILITIES

In support of the Department of Energy’s continued plans to de-inventory and reduce the footprint of Cold War era weapons’ material production sites, the K-Area Material Storage (KAMS) facility, located in the K-Area Complex (KAC) at the Savannah River Site reservation, has expanded since its startup authorization in 2000 to accommodate DOE’s material consolidation mission. During the facility’s growth and expansion, KAMS will have expanded its authorization capability of material types and storage containers to allow up to 8200 total shipping containers once the current expansion effort completes in 2014. Recognizing the need to safely and cost effectively manage other surplus material across the DOE Complex, KAC is constantly evaluating the storage of different material types within K area. When modifying storage areas in KAC, the Documented Safety Analysis (DSA) must undergo extensive calculations and reviews; however, without an extensive and proven security posture the possibility for expansion would not be possible. The KAC maintains the strictest adherence to safety and security requirements for all the SNM it handles. Disciplined Conduct of Operations and Conduct of Projects are demonstrated throughout this historical overview highlighting various improvements in capability, capacity, demonstrated cost effectiveness and utilization of the KAC as the DOE Center of Excellence for safe and secure storage of surplus SNM.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PV + Storage, Resiliency, Capacity, and Ancillary Services in SAM

This presentation from the PV Performance Modeling Collaborative workshop, grid integration track, in May 2019 outlines the current PV + Storage capabilities in the System Advisor Model (SAM) and highlights several upcoming capabilities related to storage, resiliency, capacity, and ancillary services.

14 SOLAR ENERGY↗

Enhancing Charge Storage of Mo 2 Ti 2 C 3 MXene by Partial Oxidation

Abstract Driving the pseudocapacitive redox intercalation in 2DMXenes with neutral electrolytes is important for safer, more sustainable, and improved electrochemical charge storage. Single transition metal MXenes, such as Ti 3 C 2 , have shown great promise for energy storage, owing to their high conductivity and redox activity. Mixed metallic MXenes, such as out‐of‐plane ordered Mo 2 Ti 2 C 3 , have remained underexplored in energy storage because of the absence of redox activity in most of the electrolytes. Simultaneous structural modifications and instigating intercalation pseudocapacitance in neutral electrolytes could be a viable strategy for enhancing their electrochemical properties. Herein, a facile synthesis of partially oxidized Mo 2 Ti 2 C 3 MXene (PO‐Mo 2 Ti 2 C 3 ) exhibiting improved charge storage capability is demonstrated. Optical, structural, and spectroscopic analyses indicate the formation of oxide nanostructures upon thermal oxidation of Mo 2 Ti 2 C 3 . This leads to an enhanced energy storage capability with remarkably improved cyclability as well as a high Coulombic efficiency in a neutral LiCl electrolyte. This work highlights the importance of structural modifications of MXenes to enhance their charge storage and shows the promise of less explored double transition metal MXenes in energy storage.

Chemistry↗