Search NASA⌕ Search

SEARCH · Search NASA

Results for “Stover”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Interacting nuclei in distant galaxies

The N-galaxy 3C 390.3 has been monitored spectroscopically since 1974 (Osterbrock, Koski and Phillips 1975; Oke 1988). From various archives and literature, it is found that the Balmer lines change their intensities and profiles in a dramatic manner. The H alpha profile is very broad and peculiar, and the relative intensities of its two humps changes consistently with time, possibly periodically. Before 1980, the blue hump was significantly stronger than the one in the red. From 1980 to 1983 the blue hump became stronger (see Oke 1988). After 1983 the H alpha profile has returned to its early shape and seems to have completed a full circle. Unlike the rapid (on the order of a month or even less) and aperiodic variation in the continuum and integrated line intensities, the change in broad profile seems slow and consistent. Taking the analogy of cataclysmic variables, the double-horn profiles have been observed in cases of interacting stars. For example, the emission lines, both in He II and hydrogen Balmer lines in GD 552 (Stover 1985) show double-horn profiles and periodical changes in their line profiles, including the change in ratios of two humps. It is understood that the D-wave components (Smak 1976) are the signature of an emitting disk and the S-wave component is from the emission at a hot spot which rotates and results in a moving component in the velocity space. The mass flow from the nearby interacting star provides the stream toward the core of a neutron star or white dwarf. Therefore, it is proposed that the variation of broad line profiles observed in 3C 390.3 may be the result of a pair of interacting massive cores. The rotational velocity dominates and produces a variable double-horn profile. However, the line widths observed in broad line radio galaxies are one order larger than that in interacting stars. The Balmer decrements imply a much smaller density (10(exp 10-12) cm(exp-3)) than that in the cataclysmic variables. The much larger velocity and much thinner density make it unlikely that the broad line emission is simply formed in an accretion disk. The authors postulate that a significant rotational motion is involved. If the observed squared profiles are indeed due to the rotational velocity field, one can naturally explain their rare occurrence.

Zheng, Wei↗

Effect of Thrustor Arcing on Ion Rocket System Design

Arcing between the electrodes of an ion rocket thrustor is investigated for the effect it will have on the overall design of ion rocket systems. The effect of generator, transformer, and inserted impedances on system stability and efficiency, and on operating lifetime of thrustor components are considered. Rate of arcing, preferential arc paths, speed of arc interruption, and response of thrustors to voltage transients are also discussed. The study indicates that arcing is a system hazard and that arcing rates are of prime importance in the design and development of thrustors, thrustor arrays, and system components. Two system models for reducing the hazard are proposed, based on principles developed herein, published data, and experience available from operation of nine-module electron-bombardment thrustor array. Experimental investigation of these models is presently underway.

THRUSTOR↗

Method for making small pointed thermocouples

Constantan wire worked to a needle point and covered with a copper coating produces a small, concentric, fast-reaction thermocouple that has the fast response time necessary to measure rapid temperature changes accurately and only slightly alters the environment being measured.

Stover, C. M.↗

An investigation of transient pressure and plasma properties in a pinched plasma column

The transient pinched plasma column generated in a linear Z-pinch was studied experimentally and analytically. The plasma column was investigated experimentally with the following plasma diagnostics: a special rapid response pressure transducer, a magnetic field probe, a voltage probe and discharge luminosity. Axial pressure profiles on the discharge chamber axis were used to identify three characteristic regions of plasma column behavior; they were in temporal sequence: strong axial pressure asymmetry noted early in plasma column lifetime followed by plasma heating in which there is a rapid rise in static pressure and a slight decrease static pressure before plasma column breakup. Plasma column lifetime was approximately 5 microseconds. The axial pressure asymmetry was attributed to nonsimultaneous pinching of the imploding current sheet along the discharge chamber axis. The rapid heating is attributed in part to viscous effects introduced by radial gradients in the axial streaming velocity. Turbulent heating arising from discharge current excitation of the ion acoustic wave instability is also considered a possible heating mechanism.

Stover, E. K.↗

An investigation of transient pressures and plasma properties in a pinched plasma column

The transient pinched plasma column generated in a linear Z-pinch was studied experimentally and analytically. The plasma column was investigated experimentally with several plasma diagnostics; they were: a rapid response pressure transducer, a magnetic field probe, a voltage probe, and discharge luminosity. Axial pressure profiles on the discharge chamber axis were used to identify three characteristic regions of plasma column behavior: (1) strong axial pressure asymmetry noted early in plasma column lifetime, (2) followed by plasma heating in which there is a rapid rise in static pressure, and (3) a slight decrease static pressure before plasma column breakup. Plasma column lifetime was approximately 5 microseconds. The axial pressure asymmetry was attributed to nonsimultaneous pinching of the imploding current sheet along the discharge chamber axis. The rapid heating could be attributed in part to viscous effects introduced by radial gradients in the axial streaming velocity.

Stover, E. K.↗

Transient flow and heating characteristics in a pinched plasma column.

The generation of axial flow and heating of an argon plasma in a pinched plasma column of a pulsed, linear z-pinch device was examined experimentally and analytically. Transient (about 5 microsec) axial pressure profiles identify three characteristic periods in the column history. These include (1) strong axial pressure asymmetry indicative of plasma streaming, (2) isotropic, rapidly rising plasma pressure indicative of plasma heating, and (3) column breakup. An efficient conversion of radial collapse to axial streaming velocity is identified. Mechanisms for such an effect and subsequent heating are evaluated; significance to transients in pulsed plasma accelerators is identified.

York, T. M.↗

Transient flow and heating in a pinched plasma column

The axial flow and heating of an argon plasma in a pinched plasma column of a pulsed, linear z-pinch device was experimentally examined with a unique pressure sensing instrument capable of resolving mass flow properties. Transient axial pressure profiles identify periods of intense flow and heating. Mechanisms generating such effects are considered.

York, T. M.↗

A time reference distribution concept for a time division communication network

Starting with an assumed ideal network having perfect clocks at every node and known fixed transmission delays between nodes, the effects of adding tolerances to both transmission delays and nodal clocks is described. The advantages of controlling tolerances on time rather than frequency are discussed. Then a concept is presented for maintaining these tolerances on time throughout the network. This concept, called time reference distribution, is a systematic technique for distributing time reference to all nodes of the network. It is reliable, survivable and possesses many other desirable characteristics. Some of its features such as an excellent self monitoring capability will be pointed out. Some preliminary estimates of the accuracy that might be expected are developed and there is a brief discussion of the impact upon communication system costs. Time reference distribution is a concept that appears very attractive. It has not had experimental evaluation and has not yet been endorsed for use in any communication network.

Stover, H. A.↗

System tests with electric thruster beam and accelerator directly powered from laboratory solar arrays

Laboratory high voltage solar arrays were operated directly connected to power the beam and accelerator loads of an 8-centimeter ion thruster. The beam array comprised conventional 2 by 2 centimeter solar cells; the accelerator array comprised multiple junction edge-illuminated solar cells. Conventional laboratory power supplies powered the thruster's other loads. Tests were made to evaluate thruster performance and to investigate possible electrical interactions between the solar arrays and the thruster. Thruster performance was the same as with conventional laboratory beam and accelerator power supplies. Most of the thruster beam short circuits that occurred during solar array operation were cleared spontaneously without automatic or manual intervention. No spontaneous clearing occurred during conventional power supply operation.

Stover, J. B.↗

ERDA/Lewis research center photovoltaic systems test facility

A national photovoltaic power systems test facility (of initial 10-kW peak power rating) is described. It consists of a solar array to generate electrical power, test-hardware for several alternate methods of power conversion, electrical energy storage systems, and an instrumentation and data acquisition system.

Forestieri, A. F.↗

Photovoltaic power system tests on an 8-kilowatt single-phase line-commutated inverter

Efficiency and power factor were measured as functions of solar array voltage and current. The effects of input shunt capacitance and series inductance were determined. Tests were conducted from 15 to 75 percent of the 8 kW rated inverter input power. Measured efficiencies ranged from 76 percent to 88 percent at about 50 percent of rated inverter input power. Power factor ranged from 36 percent to 72 percent.

Stover, J. B.↗

Overview of timing/synchronization for digital communications

Systems in general, and switched systems in particular, are explained. It pointed out some of the criteria that greatly influence timing/synchronization subsystem design for a military communications network but have little or no significance for civil systems. Timing techniques were evaluated in terms of fundamental features. Different combinations of these features covered most possibilities from which a synchronous timing system could be chosen.

Stover, H. A.↗