Search NASA⌕ Search

SEARCH · Search NASA

Results for “Strain Gages”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Application of Strain Gages in a Highly Advective Environment for Measurement of Fluid-Structure Interactions

A multi-year experimental program has been conducted to develop a program for applying strain gages to prototypic, plate-type fuel for high performance research reactors for use during flow testing. Plate strain measurements were intended to support the qualification of new fuel materials for use in high performance research reactors under the Materials Management and Minimization (MMM) Fuels Qualification Program (FQP). A survey of currently available strain gaging materials and processes was undertaken with a focus on applications towards thin, wide aspect ratio flow channels and fuel plates exposed to high velocity flows. Special consideration was taken to minimize the effect of the strain gage installations on the flow field. This test program has resulted in the selection of appropriate strain gage construction, adhesives, protective coatings, and assembly techniques to allow the real-time acquisition of plate strain during flow testing of the Generic Test Plate Assembly (GTPA) within the Oregon State University (OSU) Hydro-Mechanical Fuel Test Facility (HMFTF). All processes have been documented in procedures developed and utilized within the ASME NQA-1 compliant quality assurance program under which the HMFTF operates. Matrix testing has been completed using the results of this work with successful measurement of plate deformation due to hydraulic loading during flow testing.

Weiss, Aaron↗

Measurement of maximum strain of steel beam structures based on average strains from vibrating wire strain gages

In structural health monitoring, the safety of steel beam structures can be assessed by comparing the measured maximum stress and the allowable stress of the beam calculated by a design code. For the case of a steel beam subjected to variable lateral loadings, many difficulties exist in measuring the maximum stress in a beam with point sensors that can measure the strain only at a local point of a beam since the location and magnitude of the maximum stress induced in a beam by the loading change. Although traditional strain sensors can measure the strain only at a local point, a vibrating wire strain gage (VWSG) that measures integrated strains over its gage length can consider the variation of strains due to variable loadings. This paper presents an estimation model to determine the maximum strains or stresses in a steel beam based on average strains measured using VWSGs. The model is derived by defining the relation between the average strains measured using VWSGs and the maximum strains of beams. The model is experimentally tested by comparing the maximum strain directly obtained from electrical strain gages and the estimated maximum strain based on the average strain from VWSGs.

42 ENGINEERING↗

Virtual strain gage size study

DIC is a non-linear low-pass spatial filtering operation; whether we consider the effect of the subset and shape function, the strain window used in the strain calculation, of other post-processing of the results, each decision will impact the spatial resolution, of the measurement. More fundamentally, the speckle size limits, the spatial resolution by dictating the smallest possible subset. After this decision the processing settings are controlled by the allowable noise level balanced by possible bias errors created by the data filtering. This article describes a process to determine optimum DIC software settings to determine if the peak displacements or strains are being found.

97 MATHEMATICS AND COMPUTING↗

FY 2017 Status of Sodium Freezing and Remelting Tests

The Sodium Freezing and Remelting experiment facility at Argonne National Laboratory has been significantly modified and improved. The main improvement was replacement of the two original stainless steel test sections that had strain gages limited by their bonds to the stainless steel to maximum temperatures of 350°C with a single new test section with strain gages that can be utilized up to 980°C and a thin wall to enhance measured strains. Wetting of stainless steel by sodium within a practical time of one to a few days is expected to require temperatures of 450°C or greater. Thus, the higher temperature strain gages enable wetting in a short time of a few days. Wetting below 350°C would have required an impractically long time of at least weeks. Other improvements included upgrading of the loop configuration, incorporation of a cold finger to purify sodium, a new data acquisition system, and reinstallation of the many heaters, heater controllers, and thermocouples. After the loop had been heated to 400°C for about two hours, an initial sodium freezing test was conducted. It is thought that the sodium might have at least partially wetted the stainless steel wall under these conditions. The strain gage measurements indicate that an incremental step inward deformation of the test section thin wall occurred as the temperature decreased through the sodium freezing temperature. This behavior is consistent with sodium initially adhering to the stainless steel inner wall but breaking away from the wall as the freezing sodium contracted. Conduct of additional sodium freezing tests under well wetted conditions was prevented as a result of stoppage of all electrical work at Argonne by the Laboratory Director on July 25, 2017. A pathway to resuming electrical work is now in place at Argonne and additional sodium freezing testing will resume next fiscal year.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Apparatus for pre-stress-straining rod-type specimens in tension for in-situ passive fracture testing

A stress-strain testing apparatus imposes a stress-strain on a specimen while disposed in a controlled environment. Each end of the specimen is fastened to an end cap and a strain gage is attached to the specimen. An adjusting mechanism and a compression element are disposed between the end caps forming a frame for applying forces to the end caps and thereby stress-straining the specimen. The adjusting mechanism may be extended or retracted to increase or decrease the imposed stress-strain on the specimen, and the stress-strain is measured by the strain gage on the specimen while the apparatus is exposed to an environment such as high pressure hydrogen. Strain gages may be placed on the frame to measure stress-strains in the frame that may be caused by the environment.

42 ENGINEERING↗

TESTING AND ANALYSIS OF CAP CONCRETE STRESS AND STRAIN DUE TO SHRINKAGE, CREEP, AND EXPANSION FINAL REPORT

In-situ decommissioning of Reactors P- and R- at the Savannah River Site will require filling the reactor vessels with a special concrete based on materials such as magnesium phosphate, calcium aluminate or silica fume. Then the reactor vessels will be overlain with an 8 ft. thick layer of Ordinary Portland Cement (OPC) steel reinforced concrete, called the 'Cap Concrete'. The integrity of this protective layer must be assured to last for a sufficiently long period of time to avoid ingress of water into the reactor vessel and possible movement of radioactive contamination into the environment. During drying of this Cap Concrete however, shrinkage strains are set up in the concrete as a result of diffusion and evaporation of water from the top surface. This shrinkage varies with depth in the poured slab due to a non-uniform moisture distribution. This differential shrinkage results in restraint of the upper layers with larger shrinkage by lower layers with lesser displacements. Tensile stresses can develop at the surface from the strain gradients in the bulk slab, which can lead to surface cracking. Further, a mechanism called creep occurs during the curing period or early age produces strains under the action of restraining forces. To investigate the potential for surface cracking, an experimental and analytical program was started under TTQAP SRNL-RP-2009-01184. Slab sections made of Cap Concrete mixture were instrumented with embedded strain gages and relative humidity sensors and tested under controlled environmental conditions of 23 C and relative humidities (RH) of 40% and 80% over a period of 50 days. Calculation methods were also developed for predictions of stress development in the full-scale concrete placement over the reactor vessels. These methods were evaluated by simulating conditions for the test specimens and the calculation results compared to the experimental data. A closely similar test with strain gages was performed by Kim and Lee for a concrete mixture that did not employ humidity sensors and the admixtures used in this program. Yuan and Wan tried to predict the shrinkage strains and stresses in the Kim and Lee experiment, but did not include a creep analysis. Grasley and Lange conducted full restraint load tests on a concrete prism instrumented with humidity sensors over a 7 day curing period. The hypothetical case of full-scale placement of the Cap Concrete was also analyzed using the developed analytical methods. The calculation performed in this report is for scoping purposes only.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterization of High Strain Rate Mechanical behavior of AZ31 magnesium alloy using 3D Digital Image Correlation

Characterization of the material mechanical behavior at sub-Hopkinson regime (0.1 to 1000 s{sup -1}) is very challenging due to instrumentation limitations and the complexity of data analysis involved in dynamic loading. In this study, AZ31 magnesium alloy sheet specimens are tested using a custom designed servo-hydraulic machine in tension at nominal strain rates up to 1000 s{sup -1}. In order to resolve strain measurement artifacts, the specimen displacement is measured using 3D Digital Image correlation instead from actuator motion. The total strain is measured up to {approx} 30%, which is far beyond the measurable range of electric resistance strain gages. Stresses are calculated based on the elastic strains in the tab of a standard dog-bone shaped specimen. Using this technique, the stresses measured for strain rates of 100 s{sup -1} and lower show little or no noise comparing to load cell signals. When the strain rates are higher than 250 s{sup -1}, the noises and oscillations in the stress measurements are significantly decreased from {approx} 250 to 50 MPa. Overall, it is found that there are no significant differences in the elongation, although the material exhibits slight work hardening when the strain rate is increased from 1 to 100 s{sup -1}.

36 MATERIALS SCIENCE↗

Large scale centrifuge test of a geomembrane-lined landfill subject to waste settlement and seismic loading

Highlights: • A large centrifuge model of a geomembrane-lined landfill was seismically loaded. • The scaled peak acceleration of the strongest input motion was 0.6 g. • Laboratory testing was conducted to obtain properties of the model materials. • Collected data included liner strains due to downdrag and seismic loading. • Results show that settlement and seismic loading can potentially damage geomembranes. • Results can be used to validate numerical models for geomembrane performance. •The laboratory and centrifuge testing data is publicly available. - Abstract: A large scale centrifuge test of a geomembrane-lined landfill subject to waste settlement and seismic loading was conducted to help validate a numerical model for performance based design of geomembrane liner systems. The test was conducted using the 240 g-ton centrifuge at the University of California at Davis under the U.S. National Science Foundation Network for Earthquake Engineering Simulation Research (NEESR) program. A 0.05 mm thin film membrane was used to model the liner. The waste was modeled using a peat-sand mixture. The side slope membrane was underlain by lubricated low density polyethylene to maximize the difference between the interface shear strength on the top and bottom of the geomembrane and the induced tension in it. Instrumentation included thin film strain gages to monitor geomembrane strains and accelerometers to monitor seismic excitation. The model was subjected to an input design motion intended to simulate strong ground motion from the 1994 Hyogo-ken Nanbu earthquake. Results indicate that downdrag waste settlement and seismic loading together, and possibly each phenomenon individually, can induce potentially damaging tensile strains in geomembrane liners. The data collected from this test is publically available and can be used to validate numerical models for the performance of geomembrane liner systems.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Highly stretchable miniature strain sensor for large dynamic strain measurement

In this paper, a new type of highly stretchable strain sensor was developed to measure large strains. The sensor was based on the piezo-resistive response of carbon nanotube (CNT)/polydimethylsiloxane (PDMS) composite thin films. The piezo-resistive response of CNT composite gives accurate strain measurement with high frequency response, while the ultra-soft PDMS matrix provides high flexibility and ductility for large strain measurement. Experimental results show that the CNT/PDMS sensor measures large strains (up to 8 %) with an excellent linearity and a fast frequency response. The new miniature strain sensor also exhibits much higher sensitivities than the conventional foil strain gages, as its gauge factor is 500 times of that of the conventional foil strain gages.

47 OTHER INSTRUMENTATION↗

Surge Nozzle NDE Specimen Mechanical Stress Improvement Analysis

The purpose of this project was to perform a finite element analysis of a pressurized water reactor pressurizer surge nozzle mock-up to predict both the weld residual stresses created in its construction and the final stress state after the application of the Mechanical Stress Improvement Process (MSIP). Strain gages were applied to the inner diameter of the mock-up to record strain changes during the MSIP. These strain readings were used in an attempt to calculate the final stress state of the mock-up as well.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Deformation Behavior and TExture Evolution of Steel Alloys under Axial-Torsional Loading

Using hollow cylinder samples with suitable geometry obtained from round bar stock, the deformation behavior of bcc Fe based 12L14 steel alloy is evaluated under multi-axial conditions. A stacked strain gage rosette and extensometer mounted on the cylindrical surface at the mid height of the specimen provided strain tensor as a function of applied stress for pure tensile and torsion tests prior to yielding. This study examines elastic and yield behavior and effects of these with respect to texture evolution. Hollow cylinder specimen geometry (tubes) with small wall thickness and relatively (to its thickness) large inner diameter is used. The variation of observed yield surface in deviatoric plane and the effect on mode of deformation (tension versus torsion versus its combination) on stress-strain behavior is discussed. Bulk texture was studied using neutron time-of-flight diffractometer at High-Pressure-Preferred Orientation (HIPPO) - Los Alamos Neutron Science Center (LANSCE) instrument and the evolution of texture and related anisotropy for pure tension versus torsion are also included.

36 MATERIALS SCIENCE↗

Experimental determination of the stress evolution in a prebent steel very high-performance concrete beam by means of an active stressmeter

ConclusionsThis experimental research allowed to emphasize two main factors for the quality of the measurements by active stress-meters: on one hand, the accuracy of the location and the orientation of the jacks considering the severe conditions during the casting and in contrast, and the reliability with time of the embedded strain gages considering the possible presence of important electric disturbances in the environment. However, during 4 months, the quality of the strain signals used for the control turned out satisfactory and the obtained values are close to the theoretical computation. The evolution of the pressure during the same period shows a good regularity and a good agreement between the measurements and the values computed by the two-function method using the CEB-MC90 model code in its 1999 version for the prediction of concrete creep and shrinkage{sup 11} and the model of Yue and Taerwe{sup 10} for the creep recovery law (maximal difference of only 0.6 MPa after 4 months of recording). The aim of the direct measurement of stresses can be considered as reached, the prediction of the stress state in the beam according to the two-function method being validated with a precision of ±1.5% (uncertainty of about 1 MPa for a devise designed for a stress range up to 35 MPa).

42 ENGINEERING↗

Internal strain gradients quantified in bone under load using high-energy X-ray scattering.

High-energy synchrotron X-ray scattering (>60 keV) allows noninvasive quantification of internal strains within bone. In this proof-of-principle study, wide angle X-ray scattering maps internal strain vs position in cortical bone (murine tibia, bovine femur) under compression, specifically using the response of the mineral phase of carbonated hydroxyapatite. The technique relies on the response of the carbonated hydroxyapatite unit cells and their Debye cones (from nanocrystals correctly oriented for diffraction) to applied stress. Unstressed, the Debye cones produce circular rings on the two-dimensional X-ray detector while applied stress deforms the rings to ellipses centered on the transmitted beam. Ring ellipticity is then converted to strain via standard methods. Strain is measured repeatedly, at each specimen location for each applied stress. Experimental strains from wide angle X-ray scattering and an attached strain gage show bending of the rat tibia and agree qualitatively with results of a simplified finite element model. At their greatest, the apatite-derived strains approach 2500 {micro}{var_epsilon} on one side of the tibia and are near zero on the other. Strains maps around a hole in the femoral bone block demonstrate the effect of the stress concentrator as loading increased and agree qualitatively with the finite element model. Experimentally, residual strains of approximately 2000 {micro}{var_epsilon} are present initially, and strain rises to approximately 4500 {micro}{var_epsilon} at 95 MPa applied stress (about 1000 {micro}{var_epsilon} above the strain in the surrounding material). The experimental data suggest uneven loading which is reproduced qualitatively with finite element modeling.

59 BASIC BIOLOGICAL SCIENCES↗

High fidelity measurement of room temperature creep in NW alloys

The objective of this work was to assemble instrumentation to do the best resolution strain measurements with available equipment overa long (goal of 3 month) period of time on 304L samples. Two creep tests were performed on 304L samples for 10 6 seconds and instrumented with both strain gages and extensometers. The results of the test show the difficulty in accurately instrumenting creep tests for long periods of time. While the data from the strain gages at 10 6 seconds proved to be still discernable from the background noise caused by temperature and air fluctuations and instrument noise, lower creep rates will require enhanced measurement techniques. An additional one to two orders of magnitude of elapsed time appears feasible.

36 MATERIALS SCIENCE↗

Structural Health Monitoring of Epoxy Bond between Dissimilar Materials

Structures composed of adhesively bonded materials face many challenges when subjected to thermal loading, as adherend material(s) behave differently and can induce stresses in the glue bond. Current methods to test bond strength are limited to destructive tests, which increase costs to produce adhesively bonded structures. Strain gages are proposed to monitor the expansion profile of adhesive bonds as structures undergo thermal loading. Because resulting signals are DC in nature, no spectral quantities can be observed. Principle component analysis (PCA) is proposed to differentiate between damaged and undamaged structures. Training data are taken for various damage states and the minimum Mahalanobis distance is calculated to categorize testing data into damage state. The results indicate the potential for a strain-gage based monitoring system with PCA based decision-making, with further research necessary prior to implementation of the system.

36 MATERIALS SCIENCE↗

Core-drilling technique for in-situ stress evaluation in concrete structures

SummaryFor assessing the existing stresses in distressed reinforced concrete/prestressed concrete structures, the concrete core-drilling technique can be used. This core-drilling technique is a stress measurement technique in which a small core is drilled on the structure and the strain perturbations around the core are measured by instrumenting strain gages aligned in the same direction. Laboratory studies were conducted to evaluate the reliability of this concrete core-drilling technique. Calibration coefficients were evaluated experimentally for the used gage length, location, and configuration. Comparison was also made with coefficients evaluated theoretically. This technique is suitable for prestressed concrete girders where girders are prestressed in one direction (longitudinally). Also in reinforced concrete members like columns, compression zones of beams on the major bending axis (along the span) can be evaluated for their in-situ stresses. This concrete core-drilling technique can be used to determine the in-situ stress with enhanced sensitivity in “in-service” prestressed concrete structures.

36 MATERIALS SCIENCE↗

Studies of Shear Band Velocity Using Spatially and Temporally Resolved Measurements of Strain During Quasistatic Compression of Bulk Metallic Glass

We have made measurements of the temporal and spatial features of the evolution of strain during the serrated flow of Pd{sub 40}Ni{sub 40}P{sub 20} bulk metallic glass tested under quasistatic, room temperature, uniaxial compression. Strain and load data were acquired at rates of up to 400 kHz using strain gages affixed to all four sides of the specimen and a piezoelectric load cell located near the specimen. Calculation of the displacement rate requires an assumption about the nature of the shear displacement. If one assumes that the entire shear plane displaces simultaneously, the displacement rate is approximately 0.002 m/s. If instead one assumes that the displacement occurs as a localized propagating front, the velocity of the front is approximately 2.8 m/s. In either case, the velocity is orders of magnitude less than the shear wave speed ({approx}2000 m/s). The significance of these measurements for estimates of heating in shear bands is discussed.

36 MATERIALS SCIENCE↗

Extraction of Vibration Data with Imaging

To date, the primary sensing technology used to measure the vibration response has been accelerometers and strain gages mounted directly to the structure and using either wired or, more recently, wireless telemetry. Cost issues with these sensors and the associated data acquisition systems typically limit the numbers that are deployed on in situ structures. Although there are a few structures with larger sensing counts that in some cases exceed over 1000 sensors, more typical numbers range from ten to one hundred sensors resulting in low spatial resolution when they are applied to physically large systems. When one considers that nuclear power plant structures usually have complex geometries, material properties, connectivity and boundary conditions, it is clear these current approaches to vibration measurements can only provide limited information about a system’s dynamics response characteristics. As an alternative, many non-contact measurement technologies have emerged, including point wise measurement methods such as Global Positioning System (GPS), microwave interferometry, and laser Doppler vibrometry (LDV), as well as simultaneous full-field measurement methods such as electronic speckle pattern interferometry, holography interferometry, and muon tomography, some of which can provide high spatial resolution measurements. Among these methods, digital video imaging techniques have emerged as a feasible solution for full-field vibration measurements that provide significantly more detailed dynamic response information because every pixel becomes a measurement point. Furthermore, recent advances in image processing and computer vision algorithms have been successfully used to process video data for experimental and operational modal analysis. Such full-field measurements have the potential to significantly improve many current structural assessment procedures including system identification (modal parameter estimation), structural health monitoring, load reconstruction, model validation, and model updating. Furthermore, more recent full-field imaging techniques can be accomplished with relatively low-cost, commercially-available off-the-shelf cameras. However, these measurement procedures have other limitations that must be considered such as the ability to only measure visibly accessible points on a structure and a more limited dynamic range and bandwidth than can be achieved with accelerometers or strain gages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗