At least 19 records

Streak camera receiver definition study

Detailed streak camera definition studies were made as a first step toward full flight qualification of a dual channel picosecond resolution streak camera receiver for the Geoscience Laser Altimeter and Ranging System (GLRS). The streak camera receiver requirements are discussed as they pertain specifically to the GLRS system, and estimates of the characteristics of the streak camera are given, based upon existing and near-term technological capabilities. Important problem areas are highlighted, and possible corresponding solutions are discussed.

Johnson, C. B.↗

The first satellite laser echoes recorded on the streak camera

The application of the streak camera with the circular sweep for the satellite laser ranging is described. The Modular Streak Camera system employing the circular sweep option was integrated into the conventional Satellite Laser System. The experimental satellite tracking and ranging has been performed. The first satellite laser echo streak camera records are presented.

Hamal, Karel↗

Streak camera based SLR receiver for two color atmospheric measurements

To realize accurate two-color differential measurements, an image digitizing system with variable spatial resolution was designed, built, and integrated to a photon-counting picosecond streak camera, yielding a temporal scan resolution better than 300 femtosecond/pixel. The streak camera is configured to operate with 3 spatial channels; two of these support green (532 nm) and uv (355 nm) while the third accommodates reference pulses (764 nm) for real-time calibration. Critical parameters affecting differential timing accuracy such as pulse width and shape, number of received photons, streak camera/imaging system nonlinearities, dynamic range, and noise characteristics were investigated to optimize the system for accurate differential delay measurements. The streak camera output image consists of three image fields, each field is 1024 pixels along the time axis and 16 pixels across the spatial axis. Each of the image fields may be independently positioned across the spatial axis. Two of the image fields are used for the two wavelengths used in the experiment; the third window measures the temporal separation of a pair of diode laser pulses which verify the streak camera sweep speed for each data frame. The sum of the 16 pixel intensities across each of the 1024 temporal positions for the three data windows is used to extract the three waveforms. The waveform data is processed using an iterative three-point running average filter (10 to 30 iterations are used) to remove high-frequency structure. The pulse pair separations are determined using the half-max and centroid type analysis. Rigorous experimental verification has demonstrated that this simplified process provides the best measurement accuracy. To calibrate the receiver system sweep, two laser pulses with precisely known temporal separation are scanned along the full length of the sweep axis. The experimental measurements are then modeled using polynomial regression to obtain a best fit to the data. Data aggregation using normal point approach has provided accurate data fitting techniques and is found to be much more convenient than using the full rate single shot data. The systematic errors from this model have been found to be less than 3 ps for normal points.

Varghese, Thomas K.↗

Design and validation of a nanosecond short-wave infrared streak camera using gaseous detonation experiments

A custom short-wave infrared (SWIR) galvanometric streak camera was developed to provide nanosecond- scale, time-resolved optical diagnostics. The system was designed as a compact, mechanically driven alternative to traditional tube-based streak cameras, using a galvanometer mirror and multiple-reflection optical path to achieve high temporal resolution while maintaining electronic synchronization for trigger sequencing. Temporal resolution achieved 139.5 ns/px, allowing direct conversion of image-slope gradients to physical wave velocities. The instrument was validated using hydrogen-oxygen-argon detonations within a modular detonation tube, capturing transient emission structures and post-detonation decay behavior with microsecond precision. Although signal levels in filtered configurations were limited by lens transmission and detector sensitivity, the system successfully resolved intensity rise and decay characteristics across 10-60 % argon mixtures. The observed trends demonstrate the feasibility of compact galvanometer-based streak systems for high-speed SWIR imaging in reactive environments!

42 ENGINEERING↗

Streak camera time calibration procedures

Time calibration procedures for streak cameras utilizing a modulated laser beam are described. The time calibration determines a writing rate accuracy of 0.15% with a rotating mirror camera and 0.3% with an image converter camera.

Long, J.↗

High resolution vidicon-based readout system for photon-counting streak camera applications

The design, implementation, and evaluation of a high-resolution vidicon-based reconfigurable imaging system for integration into a photon-counting streak camera that can be readily coupled to a standard interface and computer have been achieved. Experimental results are reported which demonstrate that the design goals are met, providing the capability to measure differential time to better than 3 picosecond accuracy. Augmented by real-time calibration, the accuracy, linearity, noise levels, and stability of the system are adequate to support dual wavelength laser ranging.

Varghese, Thomas K.↗

Picosecond streak camera display of an intermodal coupling matrix at a multimode fiber splice

A technique is developed that permits direct visualization of the coupling matrix for all guided modes of a moderately multimode fiber optic at a splice or mode coupler. The matrix is formed by an array of spots at the output of a picosecond streak camera. The technique also permits unambiguous determination of the phase velocity and group velocity of the modes.

Louradour, F.↗

Simultaneous Spectral Temporal Adaptive Raman Spectrometer - SSTARS

Raman spectroscopy is a prime candidate for the next generation of planetary instruments, as it addresses the primary goal of mineralogical analysis, which is structure and composition. However, large fluorescence return from many mineral samples under visible light excitation can render Raman spectra unattainable. Using the described approach, Raman and fluorescence, which occur on different time scales, can be simultaneously obtained from mineral samples using a compact instrument in a planetary environment. This new approach is taken based on the use of time-resolved spectroscopy for removing the fluorescence background from Raman spectra in the laboratory. In the SSTARS instrument, a visible excitation source (a green, pulsed laser) is used to generate Raman and fluorescence signals in a mineral sample. A spectral notch filter eliminates the directly reflected beam. A grating then disperses the signal spectrally, and a streak camera provides temporal resolution. The output of the streak camera is imaged on the CCD (charge-coupled device), and the data are read out electronically. By adjusting the sweep speed of the streak camera, anywhere from picoseconds to milliseconds, it is possible to resolve Raman spectra from numerous fluorescence spectra in the same sample. The key features of SSTARS include a compact streak tube capable of picosecond time resolution for collection of simultaneous spectral and temporal information, adaptive streak tube electronics that can rapidly change from one sweep rate to another over ranges of picoseconds to milliseconds, enabling collection of both Raman and fluorescence signatures versus time and wavelength, and Synchroscan integration that allows for a compact, low-power laser without compromising ultimate sensitivity.

Blacksberg, Jordana↗

High speed photography, videography, and photonics III; Proceedings of the Meeting, San Diego, CA, August 22, 23, 1985

Papers are presented on the picosecond electronic framing camera, photogrammetric techniques using high-speed cineradiography, picosecond semiconductor lasers for characterizing high-speed image shutters, the measurement of dynamic strain by high-speed moire photography, the fast framing camera with independent frame adjustments, design considerations for a data recording system, and nanosecond optical shutters. Consideration is given to boundary-layer transition detectors, holographic imaging, laser holographic interferometry in wind tunnels, heterodyne holographic interferometry, a multispectral video imaging and analysis system, a gated intensified camera, a charge-injection-device profile camera, a gated silicon-intensified-target streak tube and nanosecond-gated photoemissive shutter tubes. Topics discussed include high time-space resolved photography of lasers, time-resolved X-ray spectrographic instrumentation for laser studies, a time-resolving X-ray spectrometer, a femtosecond streak camera, streak tubes and cameras, and a short pulse X-ray diagnostic development facility.

Ponseggi, B. G.↗

A solid state lightning propagation speed sensor

A device to measure the propagation speeds of cloud-to-ground lightning has been developed. The lightning propagation speed (LPS) device consists of eight solid state silicon photodetectors mounted behind precision horizontal slits in the focal plane of a 50-mm lens on a 35-mm camera. Although the LPS device produces results similar to those obtained from a streaking camera, the LPS device has the advantages of smaller size, lower cost, mobile use, and easier data collection and analysis. The maximum accuracy for the LPS is 0.2 microsec, compared with about 0.8 microsecs for the streaking camera. It is found that the return stroke propagation speed for triggered lightning is different than that for natural lightning if measurements are taken over channel segments less than 500 m. It is suggested that there are no significant differences between the propagation speeds of positive and negative flashes. Also, differences between natural and triggered dart leaders are discussed.

Mach, Douglas M.↗

Two wavelength satellite laser ranging using SPAD

When ranging to satellites with lasers, there are several principal contributions to the error budget: from the laser ranging system on the ground, from the satellite retroarray geometry, and from the atmosphere. Using a single wavelength, we have routinely achieved a ranging precision of 8 millimeters when ranging to the ERS-1 and Starlette satellites. The systematic error of the atmosphere, assuming the existing dispersion models, is expected to be of the order of 1 cm. Multiple wavelengths ranging might contribute to the refinement of the existing models. Taking into account the energy balance, the existing picosecond lasers and the existing receiver and detection technology, several pairs or multiple wavelengths may be considered. To be able to improve the atmospheric models to the subcentimeter accuracy level, the differential time interval (DTI) has to be determined within a few picoseconds depending on the selected wavelength pair. There exist several projects based on picosecond lasers as transmitters and on two types of detection techniques: one is based on photodetectors, like photomultipliers or photodiodes connected to the time interval meters. Another technique is based on the use of a streak camera as an echo signal detector, temporal analyzer, and time interval vernier. The temporal analysis at a single wavelength using the streak camera showed the complexity of the problem.

Prochazka, Ivan↗

A geodetic laser radar rangefinder with 10(exp -7) resolution

A novel geodetic laser radar rangefinder (GLRR) unit utilizing a pair of synchronized 10-psec streak camera systems was developed for displacement measurements of the earth's plates. In order to achieve minimum computing error and assure extremely high spatial resolution, an optical pulse registration clock was developed and used to register a fiducial mark on the time scale of the system. Conventional optical rangefinders have been limited to a relative resolution of 10(exp -6) even for short distances. The system to be reported on today has the capability of measuring a 50km range with an accuracy of 4mm corresponding to a relative resolution of 10(exp -7). With a gain of greater than 3 x 10(exp 3), the system has the capability of detecting extremely weak signals on the order of photon counting. This combined with temporal gating makes daytime measurements comparable in signal-to-noise ratio to nighttime viewing. This is useful for measuring faint signals returning over a range of several tens of kilometers. The present ranging system was designed to observe the mutual displacement of geodetic plates and was employed to measure the boundary between the Philippine and Asian geodetic plates that pass beneath the Suruga Bay near Hamamatsu City, Japan. The system has been in operation for over 3 years. In addition, the system has the ability of producing and detecting optical ranging pulses of several wavelengths simultaneously, making this a complete multicolor system. The basic GLRR system consists of a frequency stabilizing crystal, optical clock, YAG laser, KDP doubling crystal, DK*P tripling crystal, two matched streak cameras (A and B), a control computer, and an output/input periscope system.

Mizushima, Y.↗

Electrical design of the flexible imaging diffraction diagnostic for laser experiments (FIDDLE) at the National Ignition Facility (NIF)—Requirements, design, and performance

The Flexible Imaging Diffraction Diagnostic for Laser Experiments (FIDDLE) is a newly developed diagnostic for imaging time resolved diffraction in experiments at the National Ignition Facility (NIF). It builds on the successes of its predecessor, the Gated Diffraction Development Diagnostic (G3D). The FIDDLE was designed to support eight Daedalus version 2 sensors (six more hCMOS sensors than any other hCMOS-based diagnostic in NIF to date) and an integrated streak camera. We will review the electrical requirements, design, and performance of the electrical subsystems that were created to support this large number of cameras in the FIDDLE. The analysis of the data that the FIDDLE is intended to collect relies heavily on the accurate and well-understood timing of each sensor. We report camera-to-camera timing jitter of less than 100 ps rms and sensor integration times of 2.2 ns FWHM in 2-2 timing mode. Additionally, diffraction experiments on the NIF produce electric fields (EMI) on the order of 1 kV/m, which have been observed to negatively impact the performance of some electrical components of the FIDDLE. We report on the results of testing hCMOS camera electronics in a similar EMI environment generated in an offline lab. In addition, we also summarize the use of a novel approach to using a vector network analyzer as an EMI leak detector to understand and reduce the negative impacts of EMI on the FIDDLE.

47 OTHER INSTRUMENTATION↗

Optically multiplexed neutron time-of-flight technique for inertial confinement fusion

Neutron time-of-flight (nTOF) detectors are crucial in diagnosing the performance of inertial confinement fusion (ICF) experiments, which implode targets of deuterium–tritium fuel to achieve thermonuclear conditions. These detectors utilize the fusion neutron energy spectrum to extract key measurements, including the hotspot ion temperature and fuel areal density. Previous work [Danly et al., Rev. Sci. Instrum. 94, 043502 (2023)] has demonstrated adding 1D spatial resolution to an nTOF-like detector using a neutron aperture and streak camera to measure the ion temperature profile of an ICF implosion. By contrast, the study presented herein explores modifying the 1D detector to use a fast photomultiplier tube (PMT) to validate the design of a 2D spatially resolved instrument based on reconstruction from 1D profiles. The modification would collect time-of-flight traces from separate scintillators in an imaging array with one PMT using optical fibers of varying lengths to time-multiplex the signals. This technique has been demonstrated in ride-along experiments on the OMEGA laser with 20 fiber-coupled scintillator channels connected to a Photek PMT210. Results provide constraints on the fiber lengths and PMT gating requirements to promote pulse fidelity throughout all channels. Calibration of the detector to fixed nTOFs can provide a preliminary estimate of the instrument response function (IRF), although measurement of the IRF is currently under way. These results suggest that nTOF signals can potentially be time-multiplexed with fibers so long as the design is strategic to mitigate signal-to-noise reduction, modal dispersion, and charge build-up in the PMT, which has implications beyond ion temperature imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Particle Streak Velocimetry of Supersonic Nozzle Flows

A novel velocimetry technique to probe the exhaust flow of a laboratory scale combustor is being developed. The technique combines the advantages of standard particle velocimetry techniques and the ultra-fast imaging capabilities of a streak camera to probe high speed flows near continuously with improved spatial and velocity resolution. This "Particle Streak Velocimetry" technique tracks laser illuminated seed particles at up to 236 picosecond temporal resolution allowing time-resolved measurement of one-dimensional flows exceeding 2000 m/s as are found in rocket nozzles and many other applications. Developmental tests with cold nitrogen have been performed to validate and troubleshoot the technique with supersonic flows of much lower velocity and without background noise due to combusting flow. Flow velocities on the order of 500 m/s have been probed with titanium dioxide particles and a continuous-wave laser diode. Single frame images containing multiple streaks are analyzed to find the average slope of all incident particles corresponding to the centerline axial flow velocity. Long term objectives for these tests are correlation of specific impulse to theoretical combustion predictions and direct comparisons between candidate green fuels and the industry standard, monomethylhydrazine, each tested under identical conditions.

Willits, J. D.↗