At least 19 records

Experimental transient turbine blade temperatures in a research engine for gas stream temperatures cycling between 1067 and 1567 k

Experimental transient turbine blade temperatures were obtained from tests conducted on air-cooled blades in a research turbojet engine, cycling between cruise and idle conditions. Transient data were recorded by a high speed data acquisition system. Temperatures at the same phase of each transient cycle were repeatable between cycles to within 3.9 K (7 F). Turbine inlet pressures were repeatable between cycles to within 0.32 N/sq cm (0.47 psia). The tests were conducted at a gas stream temperature of 1567 K (2360 F) at cruise, and 1067 K (1460 F) at idle conditions. The corresponding gas stream pressures were about 26.2 and 22.4 N/sq cm (38 and 32.5 psia) respectively. The nominal coolant inlet temperature was about 811 K (1000 F).

Gauntner, D. J.

Advancing stream temperature prediction with a generalizable large-sample framework across CONUS river reaches

Accurately predicting stream temperature in ungauged basins remains a critical challenge for water resource management, thermoelectric power plant cooling, and ecosystem conservation. Large-sample machine learning models trained on hundreds of well-monitored river basins have shown remarkable performance; however, such models have yet to be developed solely using forcing data that can be readily extracted to simulate stream temperatures anywhere in the contiguous United States (CONUS). In this study, we present a scalable, large-sample deep learning framework using Long Short-Term Memory (LSTM) networks to simulate daily stream temperatures in ungauged basins across the CONUS. The framework leverages both modeled reanalysis of meteorological and streamflow inputs as well as static attributes available for all 2.7 million CONUS river reaches in the National Hydrography Dataset Plus (NHDPlusV2). By generating dynamical inputs from predefined thermally relevant upstream contributing areas, rather than the entire upstream basin, the model also offers improvements in very large basins where full-basin averaging can dilute the most important influences on stream temperature. Evaluated across 300 basins, the model achieves a median Mean Absolute Error (MAE) of 1.1 °C and a Nash-Sutcliffe Efficiency (NSE) of 0.95 on temporally and spatially distinct test folds—comparable to models trained exclusively using meteorological and streamflow observational data. The flexible, high-performing framework generalizes to any unmonitored river reach without significant regulation or unnatural thermal input immediately upstream, substantially expanding predictive capabilities in data-scarce regions.

Hydrology

Stream Temperature Responses to Summer Urban Rain Events Along the Savannah River

The hydrological urban heat island (HUHI) is a recent facet of the urban heat island (UHI), describing thermal enhancement of bodies of water in response to urbanization. Although the forefront of this work has been studied for large Metropolitan areas, this effect on developing cities is currently unknown. To locally measure and quantify HUHI effects in a developing city, we utilized Multi-Radar Multi Sensor (MRMS) radar-derived rainfall data to estimate rainfall in the Augusta Metropolitan Area (AMA) and the Savannah Metropolitan Area (SMA), two developing communities adjacent to the Savannah River. We analyzed mean temperature trends of two stream gauges measuring temperature at, and downstream of the central AMA and the SMA. Results show overall peak stream temperatures within AMA are reached within a 2hr timeframe with surge temperatures between 1-2 K, perhaps assisted by the presence of the Augusta Shoals further upstream. The SMA appears to have little HUHI effects due to urban greening and impacts to coastal meteorology. It is suggested that Moderate rainfall events (10-25mm of rainfall) have a significant correlation (~0.1 correlation coefficient with a significance level of 0.05) between stream temperature and rainfall, indicating potential warmer runoff input into the Savannah River. Although results seem promising, further research into moderate rainfall events are needed to determine the extent of the HUHI for AMA.

Wermter, Joseph E. [Savannah River National Labora

Experimental transient vane temperatures in a cascade for gas stream temperature cycling between 922 and 1644 K (1200 and 2500 F)

Experimental transient turbine vane metal temperatures were obtained from tests conducted on air-cooled vanes installed in a four-vane cascade for a gas temperature cycled between 922 and 1644 K (1200 and 2500 F). Transient data were recorded by a high-speed data acquisition system. Temperatures at the same phase of each transient cycle were repeatable between cycles to within 11 kelvins (20 F), simulated cruise and idle steady-state readings were repeated by the cruise and idle readings taken from the ends of a transient half-cycle at low pressure to within 17 kelvins (30 F). The tests were conducted at pressure levels of 31 and 83 N-sq cm (45 and 120 psia) with coolant temperatures of 811 and 589 K (1000 and 600 F), respectively.

Gauntner, D. J.

Foundational Dataset for Developing Large-Sample Stream Temperature Models in the Conterminous United States

This dataset provides inputs, evaluation results, and trained weights from a large-sample Long Short-Term Memory (LSTM) model designed to predict daily stream temperatures across unregulated river reaches in the conterminous United States (CONUS). It includes dynamic meteorological and hydrologic forcings, static physiographic attributes, and model outputs from cross-validation experiments spanning 300 basins. It supports reproducible modeling, direct application for new basins, and provides data suitable for integration with reservoir and river simulations under current and future climates. It contains two .zip files described below · RQ-AI_runs.zip: Model outputs from 10-fold cross-validation experiments, including observed and predicted daily stream temperatures, along with test performance metrics for water years 2017–2019. Two versions are included: 1. Model trained and validated using subbasin-area weighted dynamic features. 2. Model trained and validated using whole-basin area weighted dynamic features. · RQ-AI_inputs.zip: Collection of all formatted dynamic and static predictor datasets (meteorological, hydrologic, and physiographic features) used in model training and analysis. Detailed instructions and data structure is held at the following GitLab repository: https://code.ornl.gov/tempwise/training.

Gomez-Velez, Jesus [Oak Ridge National Laboratory

Boundary-layer Transition at High Reynolds Numbers as Obtained in Flight of a 20 Degree Cone-cylinder with Wall to Local Stream Temperature Ratios near 1.0

Boundary-layer transition data at low ratios of wall to local stream temperature have been obtained during the free flight of a highly polished cone-cylinder to a maximum Mach number of 5.02 A maximum transition Reynolds number of 32 x 10(exp 6) occurred at a distance of 25.84 inches from the cone apex. The temperature ratio at transition for a local Mach number of 4.0 was approximately 1.30 as compared with theoretical infinite stability solutions of 1.47 and 1.65 by Dunn and Lin (three-dimensional) and Van Driest (two-dimensional), respectively.

Rabb, Leaonard

Free-stream temperature, density, and pressure measurements in an expansion tube flow

An experimental study was conducted to determine test-flow conditions in the Langley pilot model expansion tube. Measurements of temperature, density, wall pressure, pitot pressure, and shock and interface velocities were compared with theoretical calculations based on various models of the flow cycle. The vibrational temperature and integrated density of the molecular oxygen component of the flow were measured by use of vacuum ultraviolet absorption techniques. These measurements indicate both the presence and possible degree of nonequilibrium in the flow. Data are compared with several simplified models of the flow cycle, and data trends are discussed.

Haggard, K. V.

Internal-liquid-film-cooling Experiments with Air-stream Temperatures to 2000 Degrees F. in 2- and 4-inch-diameter Horizontal Tubes

Report presents the results of an investigation conducted to determine the effectiveness of liquid-cooling films on the inner surfaces of tubes containing flowing hot air. Experiments were made in 2- and 4-inch-diameter straight metal tubes with air flows at temperatures from 600 degrees to 2000 degrees F. and diameter Reynolds numbers from 2.2 to 14 x 10(5). The film coolant, water, was injected around the circumference at a single axial position on the tubes at flow rates from 0.02 to .24 pound per second per foot of tube circumference (0.8 to 12 percent of the air flow). Liquid-coolant films were established and maintained around and along the tube wall in concurrent flow with the hot air. The results indicated that, in order to film cool a given surface area with as little coolant flow as possible, it may be necessary to limit the flow of coolant introduced at a single axial position and to introduce it at several axial positions. The flow rate of inert coolant required to maintain liquid-film cooling over a given area of tube surface can be estimated when the gas-flow conditions are known by means of a generalized plot of the film-cooling data.

Kinney, George R

Diffusive ignition and combustion in a wall jet

Hydrogen is injected from a downstream facing step in a wall into a high-temperature stream. Temperature and hydroxyl radical concentration are measured downstream of the injection plane by means of ultraviolet absorption spectroscopy. The experimental results are compared with theory which is based on a finite-difference solution of boundary-layer equations. Finite-rate kinetics equations are included in the analysis. The analytic predictions are also compared with previously obtained experimental results which are based on probe measurements. Comparison is made between calculated and observed ignition distances.

Kurkov, A. P.

Diffusive ignition and combustion in a wall jet

Hydrogen is injected from a downstream facing step in a wall into a high-temperature stream. Temperature and hydroxyl radical concentration are measured downstream of the injection plane by means of ultraviolet absorption spectroscopy. The experimental results are compared with theory which is based on a finite-difference solution of boundary-layer equations. Finite-rate kinetics equations are included in the analysis. The analytic predictions are also compared with previously obtained experimental results which are based on probe measurements. Comparison is made between calculated and observed ignition distances.

Kurkov, A. P.

Assessing Heterogeneity of Surface Water Temperature Following Stream Restoration and a High-Intensity Fire from Thermal Imagery

Thermal heterogeneity of rivers is essential to support freshwater biodiversity. Salmon behaviorally thermoregulate by moving from patches of warm water to cold water. When implementing river restoration projects, it is essential to monitor changes in temperature and thermal heterogeneity through time to assess the impacts to a river’s thermal regime. Lightweight sensors that record both thermal infrared (TIR) and multispectral data carried via unoccupied aircraft systems (UASs) present an opportunity to monitor temperature variations at high spatial (<0.5 m) and temporal resolution, facilitating the detection of the small patches of varying temperatures salmon require. Here, we present methods to classify and filter visible wetted area, including a novel procedure to measure canopy cover, and extract and correct radiant surface water temperature to evaluate changes in the variability of stream temperature pre- and post-restoration followed by a high-intensity fire in a section of the river corridor of the South Fork McKenzie River, Oregon. We used a simple linear model to correct the TIR data by imaging a water bath where the temperature increased from 9.5 to 33.4 °C. The resulting model reduced the mean absolute error from 1.62 to 0.35 °C. We applied this correction to TIR-measured temperatures of wetted cells classified using NDWI imagery acquired in the field. We found warmer conditions (+2.6 °C) after restoration (p < 0.001) and median absolute deviation for pre-restoration (0.30) to be less than both that of post-restoration (0.85) and post-fire (0.79) orthomosaics. In addition, there was statistically significant evidence to support the hypothesis of shifts in temperature distributions pre- and post-restoration (KS test 2009 vs. 2019, p < 0.001, D = 0.99; KS test 2019 vs. 2021, p < 0.001, D = 0.10). Moreover, we used a Generalized Additive Model (GAM) that included spatial and environmental predictors (i.e., canopy cover calculated from multispectral NDVI and photogrammetrically derived digital elevation model) to model TIR temperature from a transect along the main river channel. This model explained 89% of the deviance, and the predictor variables showed statistical significance. Collectively, our study underscored the potential of a multispectral/TIR sensor to assess thermal heterogeneity in large and complex river systems.

Barker, Matthew I. (ORCID:0000000252864930)

Full-coverage film cooling

Transpiration cooling is treated and then full coverage discrete hole injection for three injection orientations. Spacings with pitch to diameter ratios of 5 and 10 are discussed. The array is staggered, with the transverse pitch and the streamwise pitch the same. Results are presented in terms of the Stanton number using the heat transfer coefficient defined in terms of the difference between the wall temperature and the free stream temperature. Two values of Stanton number are provided for each situation: one with the injectant at wall temperature, and the other with the injectant at free stream temperature. These two values are equivalent to knowing the heat transfer coefficient and the adiabatic effectiveness. The heat transfer coefficient thus defined is used with the actual wall temperature to and the actual gas temperature to calculate the heat load. The principle of superposition thus invoked is valid exactly when the governing equations are linear.

Moffat, R. J.