Search NASASearch

SEARCH · Search NASA

Results for “Stream temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Experimental transient turbine blade temperatures in a research engine for gas stream temperatures cycling between 1067 and 1567 k

Experimental transient turbine blade temperatures were obtained from tests conducted on air-cooled blades in a research turbojet engine, cycling between cruise and idle conditions. Transient data were recorded by a high speed data acquisition system. Temperatures at the same phase of each transient cycle were repeatable between cycles to within 3.9 K (7 F). Turbine inlet pressures were repeatable between cycles to within 0.32 N/sq cm (0.47 psia). The tests were conducted at a gas stream temperature of 1567 K (2360 F) at cruise, and 1067 K (1460 F) at idle conditions. The corresponding gas stream pressures were about 26.2 and 22.4 N/sq cm (38 and 32.5 psia) respectively. The nominal coolant inlet temperature was about 811 K (1000 F).

Gauntner, D. J.

Experimental transient vane temperatures in a cascade for gas stream temperature cycling between 922 and 1644 K (1200 and 2500 F)

Experimental transient turbine vane metal temperatures were obtained from tests conducted on air-cooled vanes installed in a four-vane cascade for a gas temperature cycled between 922 and 1644 K (1200 and 2500 F). Transient data were recorded by a high-speed data acquisition system. Temperatures at the same phase of each transient cycle were repeatable between cycles to within 11 kelvins (20 F), simulated cruise and idle steady-state readings were repeated by the cruise and idle readings taken from the ends of a transient half-cycle at low pressure to within 17 kelvins (30 F). The tests were conducted at pressure levels of 31 and 83 N-sq cm (45 and 120 psia) with coolant temperatures of 811 and 589 K (1000 and 600 F), respectively.

Gauntner, D. J.

Boundary-layer Transition at High Reynolds Numbers as Obtained in Flight of a 20 Degree Cone-cylinder with Wall to Local Stream Temperature Ratios near 1.0

Boundary-layer transition data at low ratios of wall to local stream temperature have been obtained during the free flight of a highly polished cone-cylinder to a maximum Mach number of 5.02 A maximum transition Reynolds number of 32 x 10(exp 6) occurred at a distance of 25.84 inches from the cone apex. The temperature ratio at transition for a local Mach number of 4.0 was approximately 1.30 as compared with theoretical infinite stability solutions of 1.47 and 1.65 by Dunn and Lin (three-dimensional) and Van Driest (two-dimensional), respectively.

Rabb, Leaonard

Free-stream temperature, density, and pressure measurements in an expansion tube flow

An experimental study was conducted to determine test-flow conditions in the Langley pilot model expansion tube. Measurements of temperature, density, wall pressure, pitot pressure, and shock and interface velocities were compared with theoretical calculations based on various models of the flow cycle. The vibrational temperature and integrated density of the molecular oxygen component of the flow were measured by use of vacuum ultraviolet absorption techniques. These measurements indicate both the presence and possible degree of nonequilibrium in the flow. Data are compared with several simplified models of the flow cycle, and data trends are discussed.

Haggard, K. V.

Internal-liquid-film-cooling Experiments with Air-stream Temperatures to 2000 Degrees F. in 2- and 4-inch-diameter Horizontal Tubes

Report presents the results of an investigation conducted to determine the effectiveness of liquid-cooling films on the inner surfaces of tubes containing flowing hot air. Experiments were made in 2- and 4-inch-diameter straight metal tubes with air flows at temperatures from 600 degrees to 2000 degrees F. and diameter Reynolds numbers from 2.2 to 14 x 10(5). The film coolant, water, was injected around the circumference at a single axial position on the tubes at flow rates from 0.02 to .24 pound per second per foot of tube circumference (0.8 to 12 percent of the air flow). Liquid-coolant films were established and maintained around and along the tube wall in concurrent flow with the hot air. The results indicated that, in order to film cool a given surface area with as little coolant flow as possible, it may be necessary to limit the flow of coolant introduced at a single axial position and to introduce it at several axial positions. The flow rate of inert coolant required to maintain liquid-film cooling over a given area of tube surface can be estimated when the gas-flow conditions are known by means of a generalized plot of the film-cooling data.

Kinney, George R

Diffusive ignition and combustion in a wall jet

Hydrogen is injected from a downstream facing step in a wall into a high-temperature stream. Temperature and hydroxyl radical concentration are measured downstream of the injection plane by means of ultraviolet absorption spectroscopy. The experimental results are compared with theory which is based on a finite-difference solution of boundary-layer equations. Finite-rate kinetics equations are included in the analysis. The analytic predictions are also compared with previously obtained experimental results which are based on probe measurements. Comparison is made between calculated and observed ignition distances.

Kurkov, A. P.

Diffusive ignition and combustion in a wall jet

Hydrogen is injected from a downstream facing step in a wall into a high-temperature stream. Temperature and hydroxyl radical concentration are measured downstream of the injection plane by means of ultraviolet absorption spectroscopy. The experimental results are compared with theory which is based on a finite-difference solution of boundary-layer equations. Finite-rate kinetics equations are included in the analysis. The analytic predictions are also compared with previously obtained experimental results which are based on probe measurements. Comparison is made between calculated and observed ignition distances.

Kurkov, A. P.

Full-coverage film cooling

Transpiration cooling is treated and then full coverage discrete hole injection for three injection orientations. Spacings with pitch to diameter ratios of 5 and 10 are discussed. The array is staggered, with the transverse pitch and the streamwise pitch the same. Results are presented in terms of the Stanton number using the heat transfer coefficient defined in terms of the difference between the wall temperature and the free stream temperature. Two values of Stanton number are provided for each situation: one with the injectant at wall temperature, and the other with the injectant at free stream temperature. These two values are equivalent to knowing the heat transfer coefficient and the adiabatic effectiveness. The heat transfer coefficient thus defined is used with the actual wall temperature to and the actual gas temperature to calculate the heat load. The principle of superposition thus invoked is valid exactly when the governing equations are linear.

Moffat, R. J.

Indicators of Climate Change Impacts on the Water Cycle and Water Management

Managing water is a top social and economic responsibility and is expected to become even more critical as climate change, in addition to other human activities, alters water availability and quality. Robust indicators reflecting the effects of climate change on the U.S. and global water cycles are needed in order to appropriately manage water resources. Here, we describe a suite of seventeen water cycle and management indicators, which are based on synthesis of available datasets. These indicators include: average and heavy precipitation, standardized precipitation index, annual, 7-day low and 3-day high streamflow volume, streamflow timing, snow cover, snow water equivalent, groundwater level, lake water temperature, stream water temperature, dissolved oxygen, salinity, Palmer Drought Severity Index, water withdrawals and water use. We also identify three indicators that could be included in the suite of water cycle and management indicators with some additional, directed work: snowfall, evapotranspiration and soil moisture. Our conceptual framework focuses on known water cycle changes in addition to potential effects on management, and addresses water quantity and quality, as well as water use and related interactions with freshwater ecosystems, societal impacts, and management. Water cycle indicators are organized into three categories: (1) hydrologic processes, (2) water quality processes, and (3) water quality and quantity impacts. Indicators described here are recommended to serve as critical references for periodic climate assessments. As such, these indicators support analyses of the effects of global change on the natural environment, agriculture, energy, and water resources, among other sectors. Additionally, we identify research gaps and needs that can be addressed to advance the development of future indicators.

Christa D Peters-Lidard

Effects of Nose Radius and Extreme Cooling on Boundary-Layer Transition for Three Smooth 15°-Cone-Cylinders in Free Flight at Mach Numbers to 8.50

Three highly polished 15°- included- angle cone- cylinders with hemispherical tips of several diameters ( 2, 3, and 4 in.) have been flown in order to obtain boundary- layer transition data at very low wall to local stream temperature ratios, and heat- transfer data. All surfaces had a 2-microinch average roughness height. Laminar flow existed over the entire hemispherical nose of the 2- and 3-inch-tip- diameter models throughout the complete flight history. Extreme cooling to wall to local stream temperature ratios at the sonic point as low as 0.20 did not cause transition on the nose for diameters as large as 3 inches. However, extreme cooling did cause early transition on the 4-inch model where it appears probable that transition occurred forward of the 45° station at a wall to local stream temperature ratio of about 0.26. Variations in tip diameter influenced transition downstream of the nose under conditions of extreme cooling. The 2-inch- tip model was laminar at all cone- cylinder stations at temperature ratios as low as 0.32 whereas the 3- and 4-inch-tip models were turbulent at the same local flow conditions but at higher wall to local temperature ratios. Transition on the cone and cylinder of the 3- and 4-inch- tip bodies appeared to be sensitive to local Mach number, and occurred at higher local temperature ratios when values of local Mach number were higher. Increasing the nose diameter from 2 to 3 inches significantly changed the local flow conditions for which laminar flow existed on the cone- cylinder afterbody. However, a further increase in tip size t o a 4-inch diameter had no discernable effect on the local flow conditions at transition. The transition results of the 3- and 4-inch-nose-diameter smooth bodies are similar to those observed on a 7/8-inch-nose-diameter body with roughened surfaces. Turbulent boundary layers resulted in both cases at very low wall to local stream temperature ratios. Both laminar and turbulent heat-transfer data were in good agreement with theoretical Stanton numbers when heat-transfer reduction due to tip blunting was considered.

CYLINDRICAL AFTERBODY

Mixer conditions temperature of liquified gas streams

Room temperature gaseous hydrogen mixed with liquified hydrogen in a venturi produces a two- phased liquid hydrogen stream at a stable temperature. This technique is useful in laboratory testing where presently, temperature control is maintained by a calibrated heat leak that results in considerable expenditure of cryogenic refrigerants.

Talmor, E.

Design and Testing of an Automated System using Thermochromatic Liquid Crystals to Determine Local Heat Transfer Coefficients for an Impinging Jet

Using thermochromatic liquid crystal to measure surface temperature, an automated transient method with time-varying free-stream temperature is developed to determine local heat transfer coefficients. By allowing the free-stream temperature to vary with time, the need for complicated mechanical components to achieve a step temperature change is eliminated, and by using the thermochromatic liquid crystals as temperature indicators, the labor intensive task of installing many thermocouples is omitted. Bias associated with human perception of the transition of the thermochromatic liquid crystal is eliminated by using a high speed digital camera and a computer. The method is validated by comparisons with results obtained by the steady-state method for a circular Jet impinging on a flat plate. Several factors affecting the accuracy of the method are evaluated.

Tan, Benjamin