Search NASA⌕ Search

SEARCH · Search NASA

Results for “Subtraction Technique”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Optical image subtraction techniques, 1975-1985

Real- and nonreal-time optical image subtraction (OIS) techniques are reviewed. Real-time OIS techniques include source encoding, polarization modulation, pseudocolor image difference detection, the holographic shear lens technique, and nonlinear optics. Included in the nonreal-time category are speckle diffuser encoding, speckle-pattern encoding, halftone screen encoding, and polarization-shifted encoding. It is concluded that the most useful techniques are the real-time operations. It is noted that some nonreal-time optical techniques can be applied directly while others may be converted into real-time ones through the use of advance real-time spatial light modulators or electrooptic devices.

Liu, Hua-Kuang↗

A Chromaticity Analysis and PSF Subtraction Techniques for SCExAO/CHARIS Data

We present an analysis of instrument performance using new observations taken with the Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS) instrument and the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) system. In a correlation analysis of our data sets (which use the broadband mode covering the J band through the K band in a single spectrum), we find that chromaticity in the SCExAO/CHARIS system is generally worse than temporal stability. We also develop a point-spread function (PSF) subtraction pipeline optimized for the CHARIS broadband mode, including a forward modeling-based exoplanet algorithmic throughput correction scheme. We then present contrast curves using this newly developed pipeline. An analogous subtraction of the same data sets using only the H-band slices yields the same final contrasts as the full JHK sequences; this result is consistent with our chromaticity analysis, illustrating that PSF subtraction using spectral differential imaging (SDI) in this broadband mode is generally not more effective than SDI in the individual J, H, or K bands. In the future, the data processing framework and analysis developed in this paper will be important to consider for additional SCExAO/CHARIS broadband observations and other ExAO instruments which plan to implement a similar integral field spectrograph broadband mode.

Benjamin L. Gerard↗

Non-Intrusive Measurements Using Femtosecond Laser in Atmospheric Pressure Plasma Jet

Femto-second (fs) lasers offer state-of-the art non-intrusive diagnostic capabilities in plasma flow environments. The diagnostics in plasma flows using a fs-laser that are relevant to this proposal include Two-photon Absorption Laser Induced Fluorescence (TALIF) for measuring the number density of an atomic species, and Femto-second Laser Electronic Excitation Tagging (FLEET) for performing velocity measurements in plasma flows. Various aspects of these diagnostics using fs-lasers are still an active domain of research. The TALIF technique has been used to measure the number density of atomic species in various plasma flow environments like atmospheric pressure plasma jet (APPJ) and arc-jet flows. This technique utilizes a fs-laser to excite an atomic species and the subsequent relaxation process through fluorescence is recorded to make measurements. A narrow band-pass filter is used to isolate the fluorescence signal that is in the infra-red regime. However, broad-band background emissions can potentially pass through the filter and induce noise in the TALIF signal. Particularly, arc-jet plasma flows inherently contain background emissions. In such plasma flow environments, in addition to the filter, the background-subtraction technique will play an important role in reducing the noise that is induced in the number density measurements using TALIF. The proposed research focuses on evaluating the effectiveness of a background-subtraction technique by measuring atomic oxygen using a femtosecond (fs) TALIF in APPJ with induced background emissions and comparing measurements obtained without inducing the emissions. Therefore, by quantifying the changes in the signal-to-noise ratio caused by a background-subtraction technique applied for APPJ, it will enable a better understanding of the uncertainties in the background subtracted fs-TALIF measurements for arc-jet plasma flows. In addition to this, FLEET will be used to obtain velocity in the APPJ, and the impact of background emissions will be analyzed. Under this effort, the experimenters and research personnel will gain the technical know-how in the operational and theoretical aspects of the advanced fs-laser-based diagnostic techniques. The knowledge gained in this process will then also directly be applied to a separate ONR funded project at the Aerodynamics Research Center (ARC), UT Arlington, related to arc-jet flow characterization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improved Reference Sampling and Subtraction: A Technique for Reducing the Read Noise of Near-Infrared Detector Systems

Near-infrared array detectors, like the James Webb Space Telescope (JWST) NIRSpec's Teledyne's H2RGs, often provide reference pixels and a reference output. These are used to remove correlated noise. Improved reference sampling and subtraction (IRS(exp 2)) is a statistical technique for using this reference information optimally in a leastsquares sense. Compared with the traditional H2RG readout, IRS(exp 2) uses a different clocking pattern to interleave many more reference pixels into the data than is otherwise possible. Compared with standard reference correction techniques, IRS(exp 2) subtracts the reference pixels and reference output using a statistically optimized set of frequency dependent weights. The benefits include somewhat lower noise variance and much less obvious correlated noise. NIRSpec's IRS(exp 2) images are cosmetically clean, with less 1/f banding than in traditional data from the same system. This article describes the IRS(exp 2) clocking pattern and presents the equations needed to use IRS(exp 2) in systems other than NIRSpec. For NIRSpec, applying these equations is already an option in the calibration pipeline. As an aid to instrument builders, we provide our prototype IRS(exp 2) calibration software and sample JWST NIRSpec data. The same techniques are applicable to other detector systems, including those based on Teledyne's H4RG arrays. The H4RG's interleaved reference pixel readout mode is effectively one IRS(exp 2) pattern.

Methods-statistical↗

Optical Image Subtraction

Report reviews optical image subtraction techniques developed during years 1975 through 1985. Useful in such disciplines as studies of earth resources, meteorology, automatic surveillance, pattern recognition, studies of urban growth, and compression of bandwidth in communication systems. Describes following real-time techniques: source encoding, polarization modulation, pseudocolor image-difference detection, holographic-shear-lens technique, and nonlinear electro-optics. Reported non-real-time image-subtraction techniques are following, all of which involve intensity subtraction: speckle-diffuser encoding, speckle-pattern encoding, halftone-screen encoding,and polarization-shifted carrier encoding. Offers an attractive alternative to digital electronic image subtraction, is faster and treats all parts of images simultaneously.

Liu, Hua-Kuang↗

LISA Pathfinder Instrument Data Analysis

LISA Pathfinder (LPF) is an ESA-launched demonstration mission of key technologies required for the joint NASA-ESA gravitational wave observatory in space, LISA. As part of the LPF interferometry investigations, analytic models of noise sources and corresponding noise subtraction techniques have been developed to correct for effects like the coupling of test mass jitter into displacement readout, and fluctuations of the laser frequency or optical pathlength difference. Ground testing of pre-flight hardware of the Optical Metrology subsystem is currently ongoing at the Albert Einstein Institute Hannover. In collaboration with NASA Goddard Space Flight Center, the LPF mission data analysis tool LTPDA is being used to analyze the data product of these tests. Furthermore, the noise subtraction techniques and in-flight experiment runs for noise characterization are being defined as part of the mission experiment master plan. We will present the data analysis outcome of preflight hardware ground tests and possible noise subtraction strategies for in-flight instrument operations.

Guzman, Felipe↗

Analog video magnetograms in real time.

Description of a video differential photometer which is the result of an attempt to adapt television technology to the task of producing an electronic equivalent of the photographic subtraction technique. Advantages of electronic subtraction are potentially greater field sensitivity, immediate availability of the subtracted magnetograms (virtually in real time), and greater versatility in combining and comparing image data. Commercial television equipment was used in construction of the apparatus. All video subtraction, averaging, and other processing is done in analog form. The final magnetogram is displayed on an ordinary television monitor.

Smithson, R. C.↗

Confining potential in momentum space

A method is presented for the solution in momentum space of the bound state problem with a linear potential in r space. The potential is unbounded at large r leading to a singularity at small q. The singularity is integrable, when regulated by exponentially screening the r-space potential, and is removed by a subtraction technique. The limit of zero screening is taken analytically, and the numerical solution of the subtracted integral equation gives eigenvalues and wave functions in good agreement with position space calculations.

Norbury, John W.↗

Confining potential in momentum space

A method is presented for the solution in momentum space of the bound state problem with a linear potential in r space. The potential is unbounded at large r leading to a singularity at small q. The singularity is integrable, when regulated by exponentially screening the r-space potential, and is removed by a subtraction technique. The limit of zero screening is taken analytically, and the numerical solution of the subtracted integral equation gives eigenvalues and wave functions in good agreement with position space calculations.

Norbury, John W.↗

Measurement of the 136 Xe two-neutrino double-β-decay half-life via direct background subtraction in NEXT

Here, we report a measurement of the half-life of the 136 Xe two-neutrino double-β decay performed with a novel direct-background-subtraction technique. The analysis relies on the data collected with the NEXT-White detector operated with 136 Xe-enriched and 136 Xe-depleted xenon, as well as on the topology of double-electron tracks. With a fiducial mass of only 3.5 kg of Xe, a half-life of 2.34$_{-0.46}^{+0.80}$(stat)$_{-0.17}^{+0.30}$(sys)×10 21 yr is derived from the background-subtracted energy spectrum. The presented technique demonstrates the feasibility of unique background-model-independent neutrinoless double-β-decay searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exoplanet Imaging with CHARIS and Future Synergies with WFIRST CGI

The principal science goal of directly imaging exoplanets is spectroscopy. At Subaru, the SCExAO instrument uses the CHARIS integral field spectrograph (IFS) to take spectra of young, self-luminous companions and disks in the near-infrared. CHARIS provides both R70 and R20 spectral resolutions across the J, H, and K bands. Of the two, R20 is the primary observing mode, which provides both excellent spectral coverage of the companions and a larger bandpass for advanced speckle subtraction techniques. Looking to the future, the WFIRST CoronaGraph Instrument (CGI) is a technology demonstration for future missions whose spectroscopic techniques are rooted in what has been demonstrated at ground observatories. CGI will reach very high contrast in broadband light with advanced wavefront control and coronagraphy techniques, paving the way for characterizing Earth-like planets. The spectral resolution of CGI spectroscopic modes is R50 with 15% bandpasses from 600 to 970nm. The calibration, speckle subtraction, and spectral extraction methods for CGI spectroscopy has a strong heritage from techniques developed for SCExAO+CHARIS. We discuss such synergies between CHARIS and CGI characterization capabilities from both a science and engineering perspective, including the new Wollaston polarization upgrade to CHARIS.

Groff, Tyler D.↗

Effective utilization of quantum-cascade distributed-feedback lasers in absorption spectroscopy

A variable duty cycle quasi-cw frequency scanning technique was applied to reduce thermal effects resulting from the high heat dissipation of type I quantum-cascade lasers. This technique was combined with a 100-m path-length multipass cell and a zero-air background-subtraction technique to enhance detection sensitivity to a parts-in-10(9) (ppb) concentration level for spectroscopic trace-gas detection of CH4, N2O, H2O, and C2H5OH in ambient air at 7.9 micrometers. A new technique for analysis of dense high resolution absorption spectra was applied to detection of ethanol in ambient air, yielding a 125-ppb detection limit.

NASA Discipline Environmental Health↗

Delayed ripple counter simplifies square-root computation

Ripple subtract technique simplifies the logic circuitry required in a binary computing device to derive the square root of a number. Successively higher numbers are subtracted from a register containing the number out of which the square root is to be extracted. The last number subtracted will be the closest integer to the square root of the number.

Cliff, R.↗

Measurement of Device Parameters Using Image Recovery Techniques in Large-Scale IC Devices

Devices that respond to radiation on a cell level will produce histograms showing the relative frequency of cell damage as a function of damage. The measured distribution is the convolution of distributions from radiation responses, measurement noise, and manufacturing parameters. A method of extracting device characteristics and parameters from measured distributions via mathematical and image subtraction techniques is described.

radiation↗

Analysis of two Seasat synthetic aperture radar images of an urban scene

Because the Seasat satellite is not polar-orbiting, the look-directions of its SAR radar on the basic ascending and descending orbits were neither in the same direction, orthogonal to, nor opposite to, one another. This calls for a technique by means of which to identify those features within a given geographic region which were imaged from two directions by Seasat SAR and are sensitive to radar orientation. It is demonstrated that images from the two orbits with different look directions can be registered and subtracted from one another, with the resulting difference image highlighting those features that are direction-sensitive. Although this depends on a precise registration the subtraction technique is straightforward once such registration has been obtained.

Bryan, M. L.↗

Constrained Reference Star Differential Imaging: Enabling High-fidelity Imagery of Highly Structured Circumstellar Disks

High-contrast imaging presents us with the opportunity to study circumstellar disks and the planets still embedded within them, providing key insights into the formation and evolution of planetary systems. However, the postprocessing techniques that are often needed to suppress stellar halo light typically result in significant and variable loss of circumstellar light, even when using relatively conservative approaches like reference star differential imaging (RDI). We introduce “constrained reference star differential imaging” (constrained RDI), a new class of RDI point-spread-function (PSF) subtraction techniques for systems with circumstellar disks. Constrained RDI utilizes either high-resolution polarized-intensity (PI) images or disk models to severely limit or even eliminate the signal loss due to oversubtraction that is common to RDI. We demonstrate the ability of constrained RDI utilizing polarimetric data to yield an oversubtraction-free detection of the AB Aurigae protoplanetary disk in total intensity. PI-constrained RDI allows us to decisively recover the spectral signature of the confirmed, recently discovered protoplanet, AB Aurigae b. We further demonstrate that constrained RDI can be a powerful analysis tool for soon-to-be-acquired James Webb Space Telescope coronagraphic imaging of disks. In both cases, constrained RDI provides analysis-ready products that enable more detailed studies of disks and more robust verification of embedded exoplanets.

Kellen Lawson↗

Deep UV Native Fluorescence Imaging of Antarctic Cryptoendolithic Communities

An interdisciplinary team at the Jet Propulsion Laboratory Center for Life Detection has embarked on a project to provide in situ chemical and morphological characterization of Antarctic cryptoendolithic microbial communities. We present here in situ deep ultraviolet (UV) native fluorescence and environmental scanning electron microscopy images transiting 8.5 mm into a sandstone sample from the Antarctic Dry Valleys. The deep ultraviolet imaging system employs 224.3, 248.6, and 325 nm lasers to elicit differential fluorescence and resonance Raman responses from biomolecules and minerals. The 224.3 and 248.6 nm lasers elicit a fluorescence response from the aromatic amino and nucleic acids. Excitation at 325 nm may elicit activity from a variety of biomolecules, but is more likely to elicit mineral fluorescence. The resultant fluorescence images provide in situ chemical and morphological maps of microorganisms and the associated organic matrix. Visible broadband reflectance images provide orientation against the mineral background. Environmental scanning electron micrographs provided detailed morphological information. The technique has made possible the construction of detailed fluorescent maps extending from the surface of an Antarctic sandstone sample to a depth of 8.5 mm. The images detect no evidence of microbial life in the superficial 0.2 mm crustal layer. The black lichen component between 0.3 and 0.5 mm deep absorbs all wavelengths of both laser and broadband illumination. Filamentous deep ultraviolet native fluorescent activity dominates in the white layer between 0.6 mm and 5.0 mm from the surface. These filamentous forms are fungi that continue into the red (iron-rich) region of the sample extending from 5.0 to 8.5 mm. Using differential image subtraction techniques it is possible to identify fungal nuclei. The ultraviolet response is markedly attenuated in this region, apparently from the absorption of ultraviolet light by iron-rich particles coating the filaments. Below 8.5 mm the filamentous morphology of the upper layers gives way to punctate 1-2 micron particles evidencing fluorescent activity following excitation at both deep ultraviolet wavelengths.

Storrie-Lombardi, M. C.↗

Further Investigation on Chromospheric and Prominence Activity of the RS Canum Venaticorum Star SZ Piscium

To continue our study on chromospheric activity and detection for possible prominence events of the very active RS Canum Venaticorum star SZ Piscium (SZ Psc), long-term high-resolution spectroscopic observations were obtained during several observing runs from 2014 to 2018. Based on the spectral subtraction technique, the chromospheric emission of the Ca ii IRT (λ8662, λ8542, and λ8498), H{sub α}, Na i D{sub 1}, D{sub 2} doublet, H{sub β}, and Ca ii H & K lines is mainly associated with the K1 IV primary star of the SZ Psc system, in good agreement with the previous studies, and the F8 V secondary star also shows some chromospheric emission, implying its active chromosphere. Moreover, an optical flare characterized by the He i D{sub 3} line emission together with stronger emission in the other indicators was detected. Furthermore, two chromospheric active longitudes around the two quadratures of the system were identified for most of the time, and the chromospheric activity shows significant changes during a few orbital cycles. The chromospheric activity level seems to show a long-term variation during our observations. There were some excess absorption features in the subtracted H{sub α} line and the other activity indicators, which would be caused by prominence-like materials associated with the K1 IV primary star of the system. Prominence materials could absorb the chromospheric emission and continuum from the K1 IV primary star and even the F8 V secondary one.

79 ASTRONOMY AND ASTROPHYSICS↗