Search NASA⌕ Search

SEARCH · Search NASA

Results for “Super resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The Double-edged Sword of Data-driven Super-Resolution: Adversarial Super-resolution Models

Data-driven super-resolution (SR) methods are often integrated into imaging pipelines as preprocessing steps to improve downstream tasks such as classification and detection. However, these SR models introduce a previously unexplored attack surface into imaging pipelines. In this paper, we present AdvSR, a framework demonstrating that adversarial behavior can be embedded directly into SR model weights during training, requiring no access to inputs at inference time. Unlike prior attacks that perturb inputs or rely on backdoor triggers, AdvSR operates entirely at the model level. By jointly optimizing for reconstruction quality and targeted adversarial outcomes, AdvSR produces models that appear benign under standard image quality metrics while inducing downstream misclassification. We evaluate AdvSR on three SR architectures (SRCNN, EDSR, SwinIR) paired with a YOLOv11 classifier and demonstrate that AdvSR models can achieve high attack success rates with minimal quality degradation. These findings highlight a new model-level threat for imaging pipelines, with implications for how practitioners source and validate models in safety-critical applications.

Sullivan, Haley [ORNL] (ORCID:0000000274069217)↗

Super-resolution computational saturated absorption microscopy

Imaging beyond the diffraction limit barrier has attracted wide attention due to the ability to resolve previously hidden image features. Of the various super-resolution microscopy techniques available, a particularly simple method called saturated excitation microscopy (SAX) requires only simple modification of a laser scanning microscope: The illumination beam power is sinusoidally modulated and driven into saturation. SAX images are extracted from the harmonics of the modulation frequency and exhibit improved spatial resolution. Unfortunately, this elegant strategy is hindered by the incursion of shot noise that prevents high-resolution imaging in many realistic scenarios. Here, we demonstrate a technique for super-resolution imaging that we call computational saturated absorption (CSA) in which a joint deconvolution is applied to a set of images with diversity in spatial frequency support among the point spread functions (PSFs) used in the image formation with saturated laser scanning fluorescence microscopy. CSA microscopy allows access to the high spatial frequency diversity in a set of saturated effective PSFs, while avoiding image degradation from shot noise.

Murray, Gabe (ORCID:0000000295655485)↗

Spatial-Spectral Representation for X-Ray Fluorescence Image Super-Resolution

X-ray fluorescence (XRF) scanning of works of art is becoming an increasing popular nondestructive analyticalmethod. The high quality XRF spectra is necessary to obtain significant information on both major and minor elements used for characterization and provenance analysis. However, there is a tradeoff between the spatial resolution of an XRF scan and the signalto- noise ratio (SNR) of each pixel’s spectrum, due to the limited scanning time. In this project, we propose an XRF image super-resolution method to address this tradeoff; thus, obtaining a high spatial resolution XRF scan with high SNR. We fuse a lowresolution XRF image and a conventional RGB high-resolution image into a product of both high spatial and high spectral resolution XRF image. There is no guarantee of a one to one mapping between XRF spectrum and RGB color since, for instance, paintings with hidden layers cannot be detected in visible but can in X-ray wavelengths. We separate the XRF image into the visible and nonvisible components. The spatial resolution of the visible component is increased utilizing the high-resolution RGB image, whereas the spatial resolution of the non-visible component is increased using a total variation super-resolution method. Finally, the visible and nonvisible components are combined to obtain the final result.

Dai, Qiqin↗

Distinguishing one from many using super-resolution compressive sensing

We present that distinguishing whether a signal corresponds to a single source or a limited number of highly overlapping point spread functions (PSFs) is a ubiquitous problem across all imaging scales, whether detecting receptor-ligand interactions in cells or detecting binary stars. Super-resolution imaging based upon compressed sensing exploits the relative sparseness of the point sources to successfully resolve sources which may be separated by much less than the Rayleigh criterion. However, as a solution to an underdetermined system of linear equations, compressive sensing requires the imposition of constraints which may not always be valid. One typical constraint is that the PSF is known. However, the PSF of the actual optical system may reflect aberrations not present in the theoretical ideal optical system. Even when the optics are well characterized, the actual PSF may reflect factors such as non-uniform emission of the point source (e.g. fluorophore dipole emission). As such, the actual PSF may differ from the PSF used as a constraint. Similarly, multiple different regularization constraints have been suggested including the l 1 -norm, l 0 -norm, and generalized Gaussian Markov random fields (GGMRFs), each of which imposes a different constraint. Other important factors include the signal-to-noise ratio of the point sources and whether the point sources vary in intensity. In this work, we explore how these factors influence super-resolution image recovery robustness, determining the sensitivity and specificity. In conclusion, we determine an approach that is more robust to the types of PSF errors present in actual optical systems.

42 ENGINEERING↗

Deploying Adversarial Attacks in Super-Resolution Models

Reliable super-resolution methods are crucial for applications like remote sensing, grid resilience and disaster impact analysis, and standoff biometrics. These methods infuse additional high-frequency information into reconstructions, allowing for better contextualization and image intelligence. However, super-resolution models can also introduce hallucinations or other unseen vulnerabilities that could be exploited by an adversary. This is further compounded by the prominence of deep learning in these models, as models are often blindly applied on out-of-distribution images. In this work, we implement adversarial attacks in common open-source super-resolution models and examine their impact on reconstructions and downstream classification tasks. We find that an adversarially trained super-resolution model can produce high-quality reconstructions that degrade downstream classifications. Moreover, these attacks do not require access to low-resolution imagery or class labels at inference time. These results demonstrate the vulnerability of super-resolution methods to malicious actors and motivates the development of a detector for super-resolution adversarial attacks. Further exploration of adversarial attacks in this domain is required to ensure trustworthiness and robustness of super-resolution models for national security applications.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Advances in Image-Domain Multi-Resolution and Super-Resolution Algorithms for Industrial X-Ray Computed Tomography: A Literature Survey and New Insights

Industrial X-ray Computed Tomography (XCT) is a nondestructive method for inspection and character ization of materials and parts. XCT captures images of a part from various angles, and these images are then used to construct Three-Dimensional (3D) representations of that part. This method enables assessing the quality of the parts, identifying defects and understanding their physical properties without damaging them.

36 MATERIALS SCIENCE↗

Ultrafast CMOS image sensors and data-enabled super-resolution for multimodal radiographic imaging and tomography

We summarize recent progress in ultrafast Complementary Metal Oxide Semiconductor (CMOS) image sensor development and the application of neural networks for post-processing of CMOS and charge-coupled device (CCD) image data to achieve sub-pixel resolution (thus $super$-$resolution$). The combination of novel CMOS pixel designs and data-enabled image post-processing provides a promising path towards ultrafast high-resolution multi-modal radiographic imaging and tomography applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstructing High Resolution ESM Data Through a Novel Fast Super Resolution Convolutional Neural Network (FSRCNN)

In this work, we present the first application of a fast super resolution convolutional neural network (FSRCNN) based approach for downscaling earth system model (ESM) simulations. Unlike other SR approaches, FSRCNN uses the same input feature dimensions as the low resolution input. This allows it to have smaller convolution layers, avoiding over-smoothing, and reducing computational costs. We adapt the FSRCNN to improve reconstruction on ESM data, we term the FSRCNN-ESM. We use high-resolution (~0.25°) monthly averaged model output of five surface variables over North America from the US Department of Energy's Energy Exascale Earth System Model's control simulation. These high-resolution and corresponding coarsened low-resolution (~1°) pairs of images are used to train the FSRCNN-ESM and evaluate its use as a downscaling approach. We find that FSRCNN-ESM outperforms FSRCNN and other super-resolution methods in reconstructing high resolution images producing finer spatial scale features with better accuracy for surface temperature, surface radiative fluxes, and precipitation.

58 GEOSCIENCES↗

Optimal Transport for Super Resolution Applied to Astronomy Imaging

Super resolution is an essential tool in optics, especially on interstellar scales, due to physical laws restricting possible imaging resolution. We propose using optimal transport and entropy for super resolution applications. We prove that the reconstruction is accurate when sparsity is known and noise or distortion is small enough. We prove that the optimizer is stable and robust to noise and perturbations. We compare this method to a state of the art convolutional neural network and get similar results for much less computational cost and greater methodological flexibility.

Rawson, Michael G.↗

Super-resolution imaging of non-fluorescent reactions via competition

Super-resolved fluorescence microscopy techniques have enabled substantial advances in the chemical and biological sciences. However, they can only interrogate entities that fluoresce, and most chemical or biological processes do not involve fluorescent species. Here we report a competition-enabled imaging technique with super-resolution (COMPEITS) (a COMPetition-Enabled Imaging Technique with Super-resolution) that enables quantitative super-resolution imaging of non-fluorescent processes. It is based on the incorporation of competition into a single-molecule fluorescence-detection scheme. We demonstrate COMPEITS by investigating a photoelectrocatalytic reaction; we map, with nanometre precision, a non-fluorescent surface reaction that is important for water decontamination on single photocatalyst particles. The subparticle-level quantitative information of reactant adsorption affinities unambiguously decouples size- and shape-scaling laws on specific particle facets and uncovers a surprising biphasic shape dependence, leading to catalyst design principles for optimal reactant adsorption efficacy. With its ability to provide spatially resolved information on the behaviours of unlabelled, non-fluorescent entities under operando conditions, COMPEITS could interrogate a variety of surface processes in fields ranging from heterogeneous catalysis and materials engineering to nanotechnology and energy sciences.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Super-Resolution Algorithm for Enhancement of FLASH LIDAR Data: Flight Test Results

This paper describes the results of a 3D super-resolution algorithm applied to the range data obtained from a recent Flash Lidar helicopter flight test. The flight test was conducted by the NASA's Autonomous Landing and Hazard Avoidance Technology (ALHAT) project over a simulated lunar terrain facility at NASA Kennedy Space Center. ALHAT is developing the technology for safe autonomous landing on the surface of celestial bodies: Moon, Mars, asteroids. One of the test objectives was to verify the ability of 3D super-resolution technique to generate high resolution digital elevation models (DEMs) and to determine time resolved relative positions and orientations of the vehicle. 3D super-resolution algorithm was developed earlier and tested in computational modeling, and laboratory experiments, and in a few dynamic experiments using a moving truck. Prior to the helicopter flight test campaign, a 100mX100m hazard field was constructed having most of the relevant extraterrestrial hazard: slopes, rocks, and craters with different sizes. Data were collected during the flight and then processed by the super-resolution code. The detailed DEM of the hazard field was constructed using independent measurement to be used for comparison. ALHAT navigation system data were used to verify abilities of super-resolution method to provide accurate relative navigation information. Namely, the 6 degree of freedom state vector of the instrument as a function of time was restored from super-resolution data. The results of comparisons show that the super-resolution method can construct high quality DEMs and allows for identifying hazards like rocks and craters within the accordance of ALHAT requirements.

Bulyshev, Alexander↗

Novel Super-Resolution Approach to Time-Resolved Volumetric 4-Dimensional Magnetic Resonance Imaging With High Spatiotemporal Resolution for Multi-Breathing Cycle Motion Assessment

Purpose: To develop and evaluate a super-resolution approach to reconstruct time-resolved 4-dimensional magnetic resonance imaging (TR-4DMRI) with a high spatiotemporal resolution for multi-breathing cycle motion assessment. Methods and Materials: A super-resolution approach was developed to combine fast 3-dimensional (3D) cine MRI with low resolution during free breathing (FB) and high-resolution 3D static MRI during breath hold (BH) using deformable image registration. A T1-weighted, turbo field echo sequence, coronal 3D cine acquisition, partial Fourier approximation, and SENSitivity Encoding parallel acceleration were used. The same MRI pulse sequence, field of view, and acceleration techniques were applied in both FB and BH acquisitions; the intensity-based Demons deformable image registration method was used. Under an institutional review board–approved protocol, 7 volunteers were studied with 3D cine FB scan (voxel size: 5 × 5 × 5 mm{sup 3}) at 2 Hz for 40 seconds and a 3D static BH scan (2 × 2 × 2 mm{sup 3}). To examine the image fidelity of 3D cine and super-resolution TR-4DMRI, a mobile gel phantom with multi-internal targets was scanned at 3 speeds and compared with the 3D static image. Image similarity among 3D cine, 4DMRI, and 3D static was evaluated visually using difference image and quantitatively using voxel intensity correlation and Dice index (phantom only). Multi-breathing-cycle waveforms were extracted and compared in both phantom and volunteer images using the 3D cine as the references. Results: Mild imaging artifacts were found in the 3D cine and TR-4DMRI of the mobile gel phantom with a Dice index of >0.95. Among 7 volunteers, the super-resolution TR-4DMRI yielded high voxel-intensity correlation (0.92 ± 0.05) and low voxel-intensity difference (<0.05). The detected motion differences between TR-4DMRI and 3D cine were −0.2 ± 0.5 mm (phantom) and −0.2 ± 1.9 mm (diaphragms). Conclusion: Super-resolution TR-4DMRI has been reconstructed with adequate temporal (2 Hz) and spatial (2 × 2 × 2 mm{sup 3}) resolutions. Further TR-4DMRI characterization and improvement are necessary before clinical applications. Multi-breathing cycles can be examined, providing patient-specific breathing irregularities and motion statistics for future 4D radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Illuminating the Night: A Survey of Super-Resolution Methods for Nighttime Light Images

Nighttime Light (NTL) images provide critical insights into urbanization, disaster response, and energy consumption. The VIIRS Day/Night Band (DNB) sensor offers high-quality NTL imagery with daily revisit rates, but the available spatial resolution hinders fine-grained accurate analysis. Super-resolution techniques aim to increase the resolution of NTL images, enabling more detailed assessments of infrastructure, light pollution, economic activity, and power outages. However, existing state-of-the-art super-resolution methods designed for natural images struggle with the unique characteristics of NTL data. This work provides a comprehensive review of super-resolution methods across multiple image modalities, evaluates their effectiveness on VIIRS DNB data, and proposes a multi-modal super-resolution approach tailored to NTL imagery. The proposed approach integrates VIIRS DNB data with road networks and land use information to improve reconstruction accuracy and spatial detail. Code is available for this project at https://code.ornl.gov/viirs-sr/sr-demos.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using 2.5D super-resolution to improve flaw detection in metal additive manufacturing parts

Industrial X-ray computed tomography (XCT) enables non-destructive inspection of additively manufactured (AM) parts, but high-resolution scanning requires long acquisition times and significant computational resources, limiting throughput in production environments. Super-resolution techniques can recover high-resolution information from low-resolution scans, but existing methods face a trade-off between 2D approaches that ignore inter-slice information and 3D methods that are computationally prohibitive for practical deployment. To address this trade-off, we propose a 2.5D deep learning-based super-resolution approach that uses seven neighbouring low-resolution slices to super-resolve the centre slice. This work evaluates the method on real XCT scans of steel AM parts, comparing reconstruction quality and flaw detection performance of 2D, 2.5D, and 3D ESRGAN-based super-resolution methods. Results demonstrate that 2.5D super-resolution significantly improves detection of small, process-induced flaws (e.g. porosity) compared to 2D methods, while avoiding the prohibitive computational burden of full 3D approaches. These findings provide initial evidence of 2.5D super-resolution as a practical, deployable solution for improving flaw detection in high-throughput industrial XCT inspection.

X-ray CT↗