Search NASA⌕ Search

SEARCH · Search NASA

Results for “Supine Position”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

SU-F-T-520: Dosimetric Comparison of Radiation Treatment Plans for Whole Breast Irradiation Between 3D Conformal in Prone and Supine Positions Vs. VMAT and IMRT in Supine Positions

Purpose: The target volume for Whole Breast Irradiation (WBI) is dictated by location of tumor mass, breast tissue distribution, and involvement of lymph nodes. Dose coverage and Organs at Risk (OARs) sparing can be difficult to achieve in patients with unfavorable thoracic geometries. For these cases, inverse-planned and 3D-conformal prone treatments can be alternatives to traditional supine 3D-conformal plans. A dosimetric comparison can determine which of these techniques achieve optimal target coverage while sparing OARs. Methods: This study included simulation datasets for 8 patients, 5 of whom were simulated in both supine and prone positions. Positioning devices included breast boards and Vaclok bags for the supine position, and prone breast boards for the prone position. WBI 3-D conformal plans were created for patients simulated in both positions. Additional VMAT and IMRT WBI plans were made for all patients in the supine position. Results: Prone and supine 3D conformal plans had comparable PTV coverage. Prone 3D conformal plans received a significant 50% decrease to V20, V10, V5 and V30% for the ipsilateral lung in contrast to the supine plans. The heart also experienced a 10% decrease in maximum dose in the prone position, and V20, V10, V5 and V2 had significantly lower values than the supine plan. Supine IMRT and VMAT breast plans obtained comparable PTV coverage. The heart experienced a 10% decrease in maximum dose with inverse modulated plans when compared to the supine 3D conformal plan, while V20, V10, V5 and V2 showed higher values with inverse modulated plans than with supine 3D conformal plans. Conclusion: Prone 3D-conformal, and supine inverse planned treatments were generally superior in sparing OARs to supine plans with comparable PTV coverage. IMRT and VMAT plans offer sparing of OARs from high dose regions with an increase of irradiated volume in the low dose regions.

60 APPLIED LIFE SCIENCES↗

Haemodynamic changes during neck pressure and suction in seated and supine positions

We sought to quantify the contribution of cardiac output (Q) and total vascular conductance (TVC) to carotid baroreflex-mediated changes in mean arterial pressure (MAP) in the upright seated and supine positions. Acute changes in carotid sinus transmural pressure were evoked using brief 5 s pulses of neck pressure and neck suction (NP/NS) via a simplified paired neck chamber that was developed to enable beat-to-beat measurements of stroke volume using pulse-doppler ultrasound. Percentage contributions of Q and TVC were achieved by calculating the predicted change in MAP during carotid baroreflex stimulation if only the individual changes in Q or TVC occurred and all other parameters remained at control values. All NP and NS stimuli from +40 to -80 Torr (+5.33 to -10.67 kPa) induced significant changes in Q and TVC in both the upright seated and supine positions (P < 0.001). Cardiopulmonary baroreceptor loading with the supine position appeared to cause a greater reliance on carotid baroreflex-mediated changes in Q. Nevertheless, in both the seated and supine positions the changes in MAP were primarily mediated by alterations in TVC (percentage contribution of TVC at the time-of-peak MAP, seated 95 +/- 13, supine 76 +/- 17 %). These data indicate that alterations in vasomotor activity are the primary means by which the carotid baroreflex regulates blood pressure during acute changes in carotid sinus transmural pressure.

Clinical Trial↗

Comparison of Magnetic Resonance Imaging and Computed Tomography for Breast Target Volume Delineation in Prone and Supine Positions

Purpose: To determine whether T2-weighted MRI improves seroma cavity (SC) and whole breast (WB) interobserver conformity for radiation therapy purposes, compared with the gold standard of CT, both in the prone and supine positions. Methods and Materials: Eleven observers (2 radiologists and 9 radiation oncologists) delineated SC and WB clinical target volumes (CTVs) on T2-weighted MRI and CT supine and prone scans (4 scans per patient) for 33 patient datasets. Individual observer's volumes were compared using the Dice similarity coefficient, volume overlap index, center of mass shift, and Hausdorff distances. An average cavity visualization score was also determined. Results: Imaging modality did not affect interobserver variation for WB CTVs. Prone WB CTVs were larger in volume and more conformal than supine CTVs (on both MRI and CT). Seroma cavity volumes were larger on CT than on MRI. Seroma cavity volumes proved to be comparable in interobserver conformity in both modalities (volume overlap index of 0.57 (95% Confidence Interval (CI) 0.54-0.60) for CT supine and 0.52 (95% CI 0.48-0.56) for MRI supine, 0.56 (95% CI 0.53-0.59) for CT prone and 0.55 (95% CI 0.51-0.59) for MRI prone); however, after registering modalities together the intermodality variation (Dice similarity coefficient of 0.41 (95% CI 0.36-0.46) for supine and 0.38 (0.34-0.42) for prone) was larger than the interobserver variability for SC, despite the location typically remaining constant. Conclusions: Magnetic resonance imaging interobserver variation was comparable to CT for the WB CTV and SC delineation, in both prone and supine positions. Although the cavity visualization score and interobserver concordance was not significantly higher for MRI than for CT, the SCs were smaller on MRI, potentially owing to clearer SC definition, especially on T2-weighted MR images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Limb blood flow - Rest and heavy exercise in sitting and supine positions in man

The objectives of the study were twofold: (1) to determine the effect of body position (hydrostatic pressure) on total blood flow in active and passive limbs at rest and after severe exercise; and (2) to further evaluate the impedance technique for measurement of blood flow. To this end, the effect of body position on the redistribution of total blood flow in active (leg) and passive (forearm) limbs during exercise was determined by measuring total limb impedance (blood flow) in five male and one female subjects in sitting and supine positions with a modified Beckman BR-100 rheograph. The results show that, at rest and after exercise, the supine position induces significantly greater flows in the leg but not in the forearm. With severe exercise, blood flows are increased in both passive and active limbs, so that there is probably no net transfer of blood volume from passive to active muscles. The advantages of the impedance technique over other methods are stressed.

Greenleaf, J. E.↗

Exercise temperature regulation in man in the upright and supine positions.

Rectal, auditory canal, and mean skin temperatures and various metabolic measurements were taken on subjects during 70-min exercise periods, in the upright and supine positions, on a bicycle ergometer. The results indicate nonlinear relationships between sweating and core skin temperatures and suggest the action of undefined thermal and/or nonthermal inputs in the control of exercise temperature regulation.

Greenleaf, J. E.↗

Plasma volume and electrolyte shifts with heavy exercise in sitting and supine positions

An experimental study was carried out to compare fluid and electrolyte shifts after heavy exercise performed by four voluntary male subjects (26-45 yr) in sitting and supine positions. Plasma volume and electrolyte shifts were measured during the 6-min control period and for 60 min after a continuous peak oxygen uptake test. The results indicate that the most likely driving force for the restitution of plasma volume after peak exercise is provided by a change in hydrostatic and/or systemic blood pressures when exercise ceases.

Greenleaf, J. E.↗

Experimental investigation of the visual field dependency in the erect and supine positions

The increasing utilization of simulators in many fields, in addition to aeronautics and space, requires the efficient use of these devices. It seemed that personnel highly influenced by the visual scene would make desirable subjects, particularly for those simulators without sufficient motion cues. In order to evaluate this concept, some measure of the degree of influence of the visual field on the subject in necessary. As part of this undertaking, 37 male and female subjects, including eight test pilots, were tested for their visual field dependency or independency. A version of Witkin's rod and frame apparatus was used for the tests. The results showed that nearly all the test subjects exhibited some degree of field dependency, the degree varying from very high field dependency to nearly zero field dependency in a normal distribution. The results for the test pilots were scattered throughout a range similar to the results for the bulk of male subjects. The few female subjects exhibited a higher field dependency than the male subjects. The male subjects exhibited a greater field dependency in the supine position than in the erect position, whereas the field dependency of the female subjects changed only slightly.

Lichtenstein, J. H.↗

Effect of body repositioning after venous air embolism. An echocardiographic study

BACKGROUND: Current therapy for massive venous air embolism (VAE) may include the use of the left lateral recumbent (LLR) position, although its effectiveness has been questioned. This study used transesophageal echocardiography to evaluate the effect of body repositioning on intracardiac air and acute cardiac dimension changes. METHODS: Eighteen anesthetized dogs in the supine position received a venous air injection of 2.5 ml/kg at a rate of 5 ml/ s. After 1 min the dogs were repositioned into either the LLR, LLR 10 degrees head down (LLR-10 degrees), right lateral recumbence, or remained in the supine position. RESULTS: Repositioning after VAE resulted in relocation of intracardiac air to nondependent areas of the right heart. Peak right ventricular (RV) diameter increase and mean arterial pressure decrease were greater in the repositioned animals compared with those in the supine position (P < 0.05). Right ventricular diameter and mean arterial pressure showed an inverse correlation (r = 0.81). Peak left atrial diameter decrease was greater in the LLR and LLR-10 degrees positions compared with the supine position (P < 0.05). Repositioning did not influence peak pulmonary artery pressure increase, and no correlation was found between RV diameter and pulmonary artery pressure. All animals showed electrocardiogram and echocardiographic changes reconcilable with myocardial ischemia. CONCLUSIONS: In dogs, body repositioning after VAE provided no benefit in hemodynamic performance or cardiac dimension changes, although relocation of intracardiac air was demonstrated. Right ventricular air did not appear to result in significant RV outflow obstruction, as pulmonary artery pressure increased uniformly in all groups and was not influenced by the relocation of intracardiac air. The combination of increased RV afterload and arterial hypotension, possibly with subsequent RV ischemia rather than RV outflow obstruction by an airlock appeared to be the primary mechanism for cardiac dysfunction after VAE.

NASA Discipline Environmental Health↗

Role of belly board device in the age of intensity modulated radiotherapy for pelvic irradiation

Small bowel dose often represents a limiting factor for radiation treatment of pelvic malignancies. To reduce small bowel toxicity, a belly board device (BBD) with a prone position is often recommended. Intensity modulated radiotherapy (IMRT) could reduce dose to small bowel based on the desired dose-volume constraints. We investigated the efficacy of BBD in conjunction with IMRT. A total of 11 consecutive patients with the diagnosis of rectal cancer, who were candidates for definitive therapy, were selected. Patients were immobilized with BBD in prone position for simulation and treatment. Supine position computed tomography (CT) data were either acquired at the same time or during a diagnostic scan, and if existed was used. Target volumes (TV) as well as organs at risk (OAR) were delineated in both studies. Three-dimensional conformal treatment (3DCRT) and IMRT plans were made for both scans. Thus for each patient, 4 plans were generated. Statistical analysis was conducted for maximum, minimum, and mean dose to each structure. When comparing the normalized mean Gross TV dose for the different plans, there was no statistical difference found between the planning types. There was a significant difference in small bowel sparing when using prone position on BBD comparing 3DCRT and IMRT plans, favoring IMRT with a 29.6% reduction in dose (p = 0.007). There was also a statistically significant difference in small bowel sparing when comparing supine position IMRT to prone-BBD IMRT favoring prone-BBD IMRT with a reduction of 30.3% (p = 0.002). For rectal cancer when small bowel could be a limiting factor, prone position using BBD along with IMRT provides the best sparing. We conclude that whenever a dose escalation in rectal cancer is desired where small bowel could be limiting factor, IMRT in conjunction with BBD should be selected.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sleep and Respiration in Microgravity

Sleep is often reported to be of poor quality in microgravity, and studies on the ground have shown a strong relationship between sleep-disordered breathing and sleep disruption. During the 16-day Neurolab mission, we studied the influence of possible changes in respiratory function on sleep by performing comprehensive sleep recordings on the payload crew on four nights during the mission. In addition, we measured the changes in the ventilatory response to low oxygen and high carbon dioxide in the same subjects during the day, hypothesizing that changes in ventilatory control might affect respiration during sleep. Microgravity caused a large reduction in the ventilatory response to reduced oxygen. This is likely the result of an increase in blood pressure at the peripheral chemoreceptors in the neck that occurs when the normally present hydrostatic pressure gradient between the heart and upper body is abolished. This reduction was similar to that seen when the subjects were placed acutely in the supine position in one-G. In sharp contrast to low oxygen, the ventilatory response to elevated carbon dioxide was unaltered by microgravity or the supine position. Because of the similarities of the findings in microgravity and the supine position, it is unlikely that changes in ventilatory control alter respiration during sleep in microgravity. During sleep on the ground, there were a small number of apneas (cessation of breathing) and hypopneas (reduced breathing) in these normal subjects. During sleep in microgravity, there was a reduction in the number of apneas and hypopneas per hour compared to preflight. Obstructive apneas virtually disappeared in microgravity, suggesting that the removal of gravity prevents the collapse of upper airways during sleep. Arousals from sleep were reduced in microgravity compared to preflight, and virtually all of this reduction was as a result of a reduction in the number of arousals from apneas and hypopneas. We conclude that any sleep disruption in microgravity is not the result of respiratory factors.

West, John B.↗

Effects of posture on blood flow diversion by hypoxic pulmonary vasoconstriction in dogs

We used differential excretion of sulphur hexafluoride from the left and right lung to measure blood flow diversion by hypoxic pulmonary vasoconstriction (HPV) in the prone and supine positions in dogs (n = 9). Gas exchange was assessed using the multiple inert gas elimination technique. Blood flow diversion from the hypoxic (3% oxygen) left lung was mean 70.7 (SD 11.2)% in the supine compared with 57.0 (12.1)% in the prone position (P < 0.02). The supine position was associated with increased perfusion to low VA/Q regions (P < 0.05). The increased flow diversion with hypoxia in the supine position was associated with more ventilation to high VA/Q regions (P < 0.05). We conclude that flow diversion by hypoxic pulmonary vasoconstriction is greater in the supine position. This effect could contribute to the variable response in gas exchange with positioning in patients with ARDS.

Non-NASA Center↗

Effect of 3-Day Bed Rest on the Basal Sympathetic Activity and Responsiveness of this System to Physiological Stimuli In Athletes and Sedentary Subjects

The aims of this study were: (1) to examine the effect of three days of bed rest (BR) on basal plasma epinephrine [E] and norepinephrine [NE] and the catecholamine responses to various physiological stimuli, and (2) to find out whether previous physical activity modifies effects of BR. In the first series, 29 young men (11 sedentary students, 8 endurance and 10 strength trained athletes) were submitted to oral glucose tolerance test in supine position and to active orthostatic test before and after 3 days of BR. Plasma [E] and [NE] were measured after overnight fast (basal condition), at 60, 120 and 180 min after glucose ingestion (70 a), and at the 8th min of unsupported standing. In the second series, other 22 subjects (12 sedentary students, 10 endurance and 10 strength trained athletes) were submitted to 2 min cold pressor test (CPT) and exercise. Plasma E and NE were determined in the supine position after overnight fast and at 60th and 120th s of hand cooling. Then, after breakfast followed by 2-3 hour sitting, the subjects performed cycle ergometer exercise with workload increasing until volitional exhaustion. Plasma [E] and [NE] were determined at the end of each load. Plasma catecholamines were determined made radioenzymatically. After BR, basal plasma [NE] was decreased in endurance and strength athletes (p<0.01) but not in sedentary subjects. In neither group BR affected the basal [E]. Responses of both catecholamines to glucose load were diminished after BR in all three groups (p<0.05) but the effect was most pronounced in the endurance athletes. All subjects tolerated well 8-min standing although their heart rate response was increased after BR. Plasma catecholamine responses standing were not significantly affected by BR in either group but the plasma [NE] and [E] during standing were lowered after BR in endurance athletes (p<0.01). BR did not affect blood pressure and catecholamine responses to CPT. The pre- and post-exercise plasma catecholamines were similar before and after BR although the subjects achieved lower maximal loads after BR. In endurance athletes the threshold for plasma NA rise occurred at lower work intensity after than before BR (p<0.05).

Smorawinski, Jerzy↗

Effect of acute exposure to hypergravity (GX vs. GZ) on dynamic cerebral autoregulation

We examined the effects of 30 min of exposure to either +3GX (front-to-back) or +GZ (head-to-foot) centrifugation on cerebrovascular responses to 80 degrees head-up tilt (HUT) in 14 healthy individuals. Both before and after +3 GX or +3 GZ centrifugation, eye-level blood pressure (BP(eye)), end tidal PCO2 (PET(CO2)), mean cerebral flow velocity (CFV) in the middle cerebral artery (transcranial Doppler ultrasound), cerebral vascular resistance (CVR), and dynamic cerebral autoregulatory gain (GAIN) were measured with subjects in the supine position and during subsequent 80 degrees HUT for 30 min. Mean BP(eye) decreased with HUT in both the GX (n = 7) and GZ (n = 7) groups (P < 0.001), with the decrease being greater after centrifugation only in the GZ group (P < 0.05). PET(CO2) also decreased with HUT in both groups (P < 0.01), but the absolute level of decrease was unaffected by centrifugation. CFV decreased during HUT more significantly after centrifugation than before centrifugation in both groups (P < 0.02). However, these greater decreases were not associated with greater increases in CVR. In the supine position after centrifugation compared with before centrifugation, GAIN increased in both groups (P < 0.05, suggesting an autoregulatory deficit), with the change being correlated to a measure of otolith function (the linear vestibulo-ocular reflex) in the GX group (r = 0.76, P < 0.05) but not in the GZ group (r = 0.24, P = 0.60). However, GAIN was subsequently restored to precentrifugation levels during postcentrifugation HUT (i.e., as BP(eye) decreased), suggesting that both types of centrifugation resulted in a leftward shift of the cerebral autoregulation curve. We speculate that this leftward shift may have been due to vestibular activation (especially during +GX) or potentially to an adaptation to reduced cerebral perfusion pressure during +GZ.

NASA Discipline Neuroscience↗

Effect of Acute Exposure to Hypergravity (Gx vs. Gz) on Dynamic Cerebral Autoregulation

We examined the effects of 30 min of exposure to either +3G(sub x) or +3G(sub z) centrifugation on cerebrovascular responses to 800 head-up tilt (HUT) in 14 healthy individuals. Both before and after +3G(sub x) or +3G(sub z) centrifugation, eye-level blood pressure (BP(sub eye)), end tidal CO2 (P(sub ET)CO2), mean cerebral flow velocity (CFV) in the middle cerebral artery (trans cranial Doppler ultrasound), cerebral vascular resistance (CVR) and dynamic cerebral autoregulatory gain (GAIN) were measured with subjects in the supine position and during subsequent 800 HUT for 30 min. Mean BP(sub eye) decreased with HUT in both the G(sub x) (n= 7) and G(sub z) (n=7) groups (P less than 0.00l), with the decrease being greater after centrifugation only in the G(sub z) group (P less than 0.05). P(sub ET)CO2 also decreased with HUT in both groups (P less than 0.0l), but the absolute level of decrease was unaffected by centrifugation. CFV decreased during HUT more significantly after than before centrifugation in both groups (P less than 0.02). However, these greater decreases were not associated with greater increases in CVR. In the supine position after compared to before centrifugation, GAIN increased in both groups (P less than 0.05, suggesting an autoregulatory deficit), with the change being correlated to a measure of otolith function (the linear vestibulo-ocular reflex) in the G(sub x) group (R=0.76, P less than 0.05) but not in the G(sub z) group (R=0.24, P=0.60). However, GAIN was subsequently restored to pre-centrifugation levels during post-centrifugation HUT (i.e., as BP(sub eye) decreased), suggesting that both types of centrifugation resulted in a leftward shift of the cerebral autoregulation curve. We speculate that this leftward shift may have been due to vestibular activation (especially during +G(sub x)) or potentially to an adaptation to reduced cerebral perfusion pressure during +G(sub z).

Serrador, Jorge M.↗

Whole breast nodal irradiation using supine VMAT and prone 3D planning: A case study

The purpose of this study was to compare the variations in doses to the ipsilateral lung and heart between the supine whole breast and nodal volumetric-modulated arc therapy (VMAT) technique and the prone 3-dimensional conformal radiation therapy (3DCRT) technique. In this study, 3 patients who were simulated in the prone and supine positions were planned using supine VMAT and prone 3DCRT techniques to compare planning target volume (PTV) coverage as well as dose to organs at risk (ORs), including the heart and ipsilateral lung. Although all constraints were met, the ideal treatment technique depended on the patient's anatomy and lumpectomy location. Supine VMAT provided excellent coverage to the target structures but encountered difficulty in limiting dose to the ipsilateral lung and heart. When compared with the supine VMAT technique, the prone 3DCRT limited dose to the ipsilateral lung and heart but provided less dose coverage to the target volumes.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-418: Evaluation of Organs at Risk (OAR) Sparing in Left Breast Irradiation Techniques

Purpose: To compare dose to organs at risk (OAR) for left sided breast radiation therapy with comparable planning target volume (PTV) coverage in three techniques; free breathing in supine position (FB), deep inspirational breath hold in supine (DIBH) and free breathing in prone position (PP). Methods: Ten left sided breast cancer patients suitable for this study underwent a CT scan in three techniques e.g. supine, FB and DIBH and prone position (PP). One radiation oncologist contoured the PTV and OAR (cardiac components) based on RTOG guidelines. Treatment plans were optimized using field-in-field technique with AAA algorithm. Each plan was optimized to provide identical coverage to PTV such that a reasonable comparison in OAR dosimetry can be evaluated. The prescribed dose to PTV were 42.56 Gy; 2.66 Gy in 16 fractions. Results: Average lung dose parameters; Dmean, V10, V20 and V30 were 0.5 Gy, 0.6%, 0.2%, and 0.1% respectively in PP which is significantly lower than FB (5.9 Gy, 14.2%, 10.7 %, and 8.4%) and DIBH (5.8 Gy, 14.3%, 10.2%, 7.8%). Similarly average heart Dmean, V2.5, V5, V10, and V20 were much lower in PP (1.2Gy, 9.1%, 2.1%, 0.8%, and 0.4%), and in DIBH (1.2 Gy, 10.6%, 1.7%, 0.5%, and 0.1%) compared to FB (2.6 Gy, 21%, 7.2%, 4.4% and 3.3%) respectively. Similar findings were also noted in the heart component left anterior descending artery (LAD) and Left ventricle (LV) which are correlated to radiation related toxicity. Conclusion: Based on the calculated dose, FB technique provides highest heart and lung dose. Prone has lowest lung dose, and DIBH has lowest LAD dose. It is found that PP is always superior for heart, LV, LAD and lung as compared to FB. This conclusion is in contrast to some published study concluding that prone position has no benefit for heart sparing.

60 APPLIED LIFE SCIENCES↗

Optimal Patient Positioning (Prone Versus Supine) for VMAT in Gynecologic Cancer: A Dosimetric Study on the Effect of Different Margins

Purpose/Objective: It is unknown whether the historically found dosimetric advantages of treating gynecologic cancer with the patient in a prone position with use of a small-bowel displacement device (belly-board) remain when volumetric arc therapy (VMAT) is used and whether these advantages depend on the necessary margin between clinical target volume (CTV) and planning target volume (PTV). The aim of this study is to determine the best patient position (prone or supine) in terms of sparing organs at risk (OAR) for various CTV-to-PTV margins and VMAT dose delivery. Methods and Materials: In an institutional review board—approved study, 26 patients with gynecologic cancer scheduled for primary (9) or postoperative (17) radiation therapy were scanned in a prone position on a belly-board and in a supine position on the same day. The primary tumor CTV, nodal CTV, bladder, bowel, and rectum were delineated on both scans. The PTVs were created each with a different margin for the primary tumor and nodal CTV. The VMAT plans were generated with our in-house system for automated treatment planning. For all margin combinations, the supine and prone plans were compared with consideration of all OAR dose-volume parameters but with highest priority given to bowel cavity V{sub 45Gy} (cm{sup 3}). Results: For both groups, the prone position reduced the bowel cavity V{sub 45Gy}, in particular for nodal margins ≥10 mm (ΔV{sub 45Gy} = 23.9 ± 10.6 cm{sup 3}). However, for smaller margins, the advantage was much less pronounced (ΔV{sub 45Gy} = 6.5 ± 3.0 cm{sup 3}) and did not reach statistical significance. The rectum mean dose (D{sub mean}) was significantly lower (ΔD{sub mean} = 2.5 ± 0.3 Gy) in the prone position for both patient groups and for all margins, and the bladder D{sub mean} was significantly lower in the supine position (ΔD{sub mean} = 2.6 ± 0.4 Gy) only for the postoperative group. The advantage of the prone position was not present if it needed a larger margin than the supine position. Conclusion: For patients with gynecologic cancer, the historically found dosimetric advantages for the prone position remain for modern dose delivery techniques if large margins are needed. However, the advantage is lost for small margins and if the prone position needs a larger margin than the supine position.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Short-duration spaceflight impairs human carotid baroreceptor-cardiac reflex responses

The effect of a spaceflight on the vagally mediated baroreceptor-cardiac reflex responses of humans were investigated by measuring the responses (provoked by neck pressure changes) in supine position and the heart rate and blood pressure in the supine and standing positions in 16 astronauts before and after 4- to 5-day long Space Shuttle missions. The results showed that exposures to spaceflight resulted in reduced baseline levels of the vagal-cardiac outflow and the vagally mediated responses to changes of the arterial baroreceptor input and that these changes contribute to postflight reductions of astronauts' ability to maintain standing arterial pressures.

Fritsch, Janice M.↗