Search NASA⌕ Search

SEARCH · Search NASA

Results for “Surface imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Correlative Surface Imaging Reveals Chemical Signatures for Bacterial Hotspots on Plant Roots

The rhizosphere is arguably the most complex microbial habitat on earth, comprising an integrated network of plant roots, soil and a highly diverse microbial community (the rhizosphere microbiome)1. Understanding, predicting and controlling plant-microbe interactions in the rhizosphere will allow us to harness the plant microbiome as a means to increase or restore plant ecosystem productivity, improve plant responses to a wide range of environmental perturbations, and mitigate effects of climate change by designing ecosystems for long-term soil carbon storage1. To this end, it is imperative to develop new molecular approaches with high spatial resolution to capture interactions at the plant-microbe, microbe-microbe, and plant-plant interfaces. In this work, we designed an imaging sample holder that allows integrated surface imaging tools to map the same locations of a plant root-microbe interface with submicron lateral resolutions, providing novel in vivo analysis of root-microbe interactions. Specifically, confocal fluorescence microscopy, time-of-flight secondary ion mass spectrometry (ToF-SIMS), X-ray photoelectron spectroscopy (XPS), and scanning electron microscope (SEM) were used for the first time for correlative imaging of the Brachypodium distachyon root and its interaction with Pseudomonas SW25, a typical plant growth-promoting soil bacterium. Imaging data suggest that the root surface is inhomogeneous and that the interaction between Pseudomonas and Brachypodium roots was confined to only few spots along the sampled root segments and that the bacterial attachment spots were enriched in Na- and S-related and high-mass organic species. We conclude that attachment of the Pseudomonas cells to the root surface is outcompeted by strong root-soil mineral interactions but facilitated by formation of extracellular polymeric substances (EPS).

Plant root, Plant growth-promoting bacteria, soil,↗

Molded plasmonic crystals for detecting and spatially imaging surface bound species by surface-enhanced Raman scattering.

This report introduces a type of plasmonic crystal that consists of metal coated nanostructures of relief molded on a polymer film as a substrate for surface-enhanced Raman scattering (SERS). Such crystals exhibit SERS enhancement factors of {approx} 10{sup 5}, over large areas and with sufficiently high levels of uniformity for precise two-dimensional Raman mapping of surface bound monolayers. The ease of fabrication together with the high sensitivities and spatial resolution that can be achieved suggests an attractive route to SERS substrates for portable chemical warfare agent detection, environmental monitors, noninvasive imaging of biomolecules, and other applications.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Development of a Mars Surface Imager

The Mars Surface Imager (MSI) is a multispectral, stereoscopic, panoramic imager that allows imaging of the full scene around a Mars lander from the lander body to the zenith. It has two functional components: panoramic imaging and sky imaging. In the most recent version of the MSI, called PIDDP-cam, a very long multi-line color CCD, an innovative high-performance drive system, and a state-of-the-art wavelet image compression code have been integrated into a single package. The requirements for the flight version of the MSI and the current design are presented.

Squyres, Steve W.↗

A Voluntary Breath-Hold Treatment Technique for the Left Breast With Unfavorable Cardiac Anatomy Using Surface Imaging

Purpose: Breath-hold (BH) treatments can be used to reduce cardiac dose for patients with left-sided breast cancer and unfavorable cardiac anatomy. A surface imaging technique was developed for accurate patient setup and reproducible real-time BH positioning. Methods and Materials: Three-dimensional surface images were obtained for 20 patients. Surface imaging was used to correct the daily setup for each patient. Initial setup data were recorded for 443 fractions and were analyzed to assess random and systematic errors. Real time monitoring was used to verify surface placement during BH. The radiation beam was not turned on if the BH position difference was greater than 5 mm. Real-time surface data were analyzed for 2398 BHs and 363 treatment fractions. The mean and maximum differences were calculated. The percentage of BHs greater than tolerance was calculated. Results: The mean shifts for initial patient setup were 2.0 mm, 1.2 mm, and 0.3 mm in the vertical, longitudinal, and lateral directions, respectively. The mean 3-dimensional vector shift was 7.8 mm. Random and systematic errors were less than 4 mm. Real-time surface monitoring data indicated that 22% of the BHs were outside the 5-mm tolerance (range, 7%-41%), and there was a correlation with breast volume. The mean difference between the treated and reference BH positions was 2 mm in each direction. For out-of-tolerance BHs, the average difference in the BH position was 6.3 mm, and the average maximum difference was 8.8 mm. Conclusions: Daily real-time surface imaging ensures accurate and reproducible positioning for BH treatment of left-sided breast cancer patients with unfavorable cardiac anatomy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel spirometry based on optical surface imaging

Purpose: To evaluate the feasibility of using optical surface imaging (OSI) to measure the dynamic tidal volume (TV) of the human torso during free breathing. Methods: We performed experiments to measure volume or volume change in geometric and deformable phantoms as well as human subjects using OSI. To assess the accuracy of OSI in volume determination, we performed experiments using five geometric phantoms and two deformable body phantoms and compared the values with those derived from geometric calculations and computed tomography (CT) measurements, respectively. To apply this technique to human subjects, an institutional review board protocol was established and three healthy volunteers were studied. In the human experiment, a high-speed image capture mode of OSI was applied to acquire torso images at 4–5 frames per second, which was synchronized with conventional spirometric measurements at 5 Hz. An in-house MATLAB program was developed to interactively define the volume of interest (VOI), separate the thorax and abdomen, and automatically calculate the thoracic and abdominal volumes within the VOIs. The torso volume change (TV C = ΔV{sub torso} = ΔV{sub thorax} + ΔV{sub abdomen}) was automatically calculated using full-exhalation phase as the reference. The volumetric breathing pattern (BP{sub v} = ΔV{sub thorax}/ΔV{sub torso}) quantifying thoracic and abdominal volume variations was also calculated. Under quiet breathing, TVC should equal the tidal volume measured concurrently by a spirometer with a conversion factor (1.08) accounting for internal and external differences of temperature and moisture. Another MATLAB program was implemented to control the conventional spirometer that was used as the standard. Results: The volumes measured from the OSI imaging of geometric phantoms agreed with the calculated volumes with a discrepancy of 0.0% ± 1.6% (range −1.9% to 2.5%). In measurements from the deformable torso/thorax phantoms, the volume differences measured using OSI imaging and CT imaging were 1.2% ± 2.1% (range −0.5% to 3.6%), with a linear regression fitting (slope = 1.02 and R{sup 2} = 0.999). In volunteers, the relative error in OSI tidal volume measurement was −2.2% ± 4.9% (range −9.2% to 4.8%) and a correlation of r = 0.98 was found with spirometric measurement. The breathing pattern values of the three volunteers were substantially different from each other (BP{sub v} = 0.15, 0.45, and 0.32). Conclusions: This study demonstrates the feasibility of using OSI to measure breathing tidal volumes and breathing patterns with adequate accuracy. This is the first time that dynamic breathing tidal volume as well as breathing patterns is measured using optical surface imaging. The OSI-observed movement of the entire torso could serve as a new respiratory surrogate in the treatment room during radiation therapy.

60 APPLIED LIFE SCIENCES↗

SU-E-J-55: End-To-End Effectiveness Analysis of 3D Surface Image Guided Voluntary Breath-Holding Radiotherapy for Left Breast

Purpose To evaluate the effectiveness of using 3D-surface-image to guide breath-holding (BH) left-side breast treatment. Methods Two 3D surface image guided BH procedures were implemented and evaluated: normal-BH, taking BH at a comfortable level, and deep-inspiration-breath-holding (DIBH). A total of 20 patients (10 Normal-BH and 10 DIBH) were recruited. Patients received a BH evaluation using a commercialized 3D-surface- tracking-system (VisionRT, London, UK) to quantify the reproducibility of BH positions prior to CT scan. Tangential 3D/IMRT plans were conducted. Patients were initially setup under free-breathing (FB) condition using the FB surface obtained from the untaged CT to ensure a correct patient position. Patients were then guided to reach the planned BH position using the BH surface obtained from the BH CT. Action-levels were set at each phase of treatment process based on the information provided by the 3D-surface-tracking-system for proper interventions (eliminate/re-setup/ re-coaching). We reviewed the frequency of interventions to evaluate its effectiveness. The FB-CBCT and port-film were utilized to evaluate the accuracy of 3D-surface-guided setups. Results 25% of BH candidates with BH positioning uncertainty > 2mm are eliminated prior to CT scan. For >90% of fractions, based on the setup deltas from3D-surface-trackingsystem, adjustments of patient setup are needed after the initial-setup using laser. 3D-surface-guided-setup accuracy is comparable as CBCT. For the BH guidance, frequency of interventions (a re-coaching/re-setup) is 40%(Normal-BH)/91%(DIBH) of treatments for the first 5-fractions and then drops to 16%(Normal-BH)/46%(DIBH). The necessity of re-setup is highly patient-specific for Normal-BH but highly random among patients for DIBH. Overall, a −0.8±2.4 mm accuracy of the anterior pericardial shadow position was achieved. Conclusion 3D-surface-image technology provides effective intervention to the treatment process and ensures favorable day-to-day setup accuracy. DIBH setup appears to be more uncertain and this would be the patient group who will definitely benefit from the extra information of 3D surface setup.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-TeP1-03: Pre-Treatment Surface Imaging Based Collision Detection

Purpose: Modern radiotherapy increasingly employs large immobilization devices, gantry attachments, and couch rotations for treatments. All of which raise the risk of collisions between the patient and the gantry / couch. Collision detection is often achieved by manually checking each couch position in the treatment room and sometimes results in extraneous imaging if collisions are detected after image based setup has begun. In the interest of improving efficiency and avoiding extra imaging, we explore the use of a surface imaging based collision detection model. Methods: Surfaces acquired from AlignRT (VisionRT, London, UK) were transferred in wavefront format to a custom Matlab (Mathworks, Natick, MA) software package (CCHECK). Computed tomography (CT) scans acquired at the same time were sent to CCHECK in DICOM format. In CCHECK, binary maps of the surfaces were created and overlaid on the CT images based on the fixed relationship of the AlignRT and CT coordinate systems. Isocenters were added through a graphical user interface (GUI). CCHECK then compares the inputted surfaces to a model of the linear accelerator (linac) to check for collisions at defined gantry and couch positions. Note, CCHECK may be used with or without a CT. Results: The nominal surface image field of view is 650 mm × 900 mm, with variance based on patient position and size. The accuracy of collision detections is primarily based on the linac model and the surface mapping process. The current linac model and mapping process yield detection accuracies on the order of 5 mm, assuming no change in patient posture between surface acquisition and treatment. Conclusions: CCHECK provides a non-ionizing method to check for collisions without the patient in the treatment room. Collision detection accuracy may be improved with more robust linac modeling. Additional gantry attachments (e.g. conical collimators) can be easily added to the model.

60 APPLIED LIFE SCIENCES↗

Accuracy Evaluation of a 3-Dimensional Surface Imaging System for Guidance in Deep-Inspiration Breath-Hold Radiation Therapy

Purpose: To investigate the applicability of 3-dimensional (3D) surface imaging for image guidance in deep-inspiration breath-hold radiation therapy (DIBH-RT) for patients with left-sided breast cancer. For this purpose, setup data based on captured 3D surfaces was compared with setup data based on cone beam computed tomography (CBCT). Methods and Materials: Twenty patients treated with DIBH-RT after breast-conserving surgery (BCS) were included. Before the start of treatment, each patient underwent a breath-hold CT scan for planning purposes. During treatment, dose delivery was preceded by setup verification using CBCT of the left breast. 3D surfaces were captured by a surface imaging system concurrently with the CBCT scan. Retrospectively, surface registrations were performed for CBCT to CT and for a captured 3D surface to CT. The resulting setup errors were compared with linear regression analysis. For the differences between setup errors, group mean, systematic error, random error, and 95% limits of agreement were calculated. Furthermore, receiver operating characteristic (ROC) analysis was performed. Results: Good correlation between setup errors was found: R{sup 2}=0.70, 0.90, 0.82 in left-right, craniocaudal, and anterior-posterior directions, respectively. Systematic errors were {<=}0.17 cm in all directions. Random errors were {<=}0.15 cm. The limits of agreement were -0.34-0.48, -0.42-0.39, and -0.52-0.23 cm in left-right, craniocaudal, and anterior-posterior directions, respectively. ROC analysis showed that a threshold between 0.4 and 0.8 cm corresponds to promising true positive rates (0.78-0.95) and false positive rates (0.12-0.28). Conclusions: The results support the application of 3D surface imaging for image guidance in DIBH-RT after BCS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of the Accuracy of a 3D Surface Imaging System for Patient Setup in Head and Neck Cancer Radiotherapy

Purpose: To evaluate the accuracy of three-dimensional (3D) surface imaging system (AlignRT) registration algorithms for head-and-neck cancer patient setup during radiotherapy. Methods and Materials: Eleven patients, each undergoing six repeated weekly helical computed tomography (CT) scans during treatment course (total 77 CTs including planning CT), were included in the study. Patient surface images used in AlignRT registration were not captured by the 3D cameras; instead, they were derived from skin contours from these CTs, thereby eliminating issues with immobilization masks. The results from surface registrations in AlignRT based on CT skin contours were compared to those based on bony anatomy registrations in Pinnacle{sup 3}, which was considered the gold standard. Both rigid and nonrigid types of setup errors were analyzed, and the effect of tumor shrinkage was investigated. Results: The maximum registration errors in AlignRT were 0.2 Degree-Sign for rotations and 0.7 mm for translations in all directions. The rigid alignment accuracy in the head region when applied to actual patient data was 1.1 Degree-Sign , 0.8 Degree-Sign , and 2.2 Degree-Sign in rotation and 4.5, 2.7, and 2.4 mm in translation along the vertical, longitudinal, and lateral axes at 90% confidence level. The accuracy was affected by the patient's weight loss during treatment course, which was patient specific. Selectively choosing surface regions improved registration accuracy. The discrepancy for nonrigid registration was much larger at 1.9 Degree-Sign , 2.4 Degree-Sign , and 4.5 Degree-Sign and 10.1, 11.9, and 6.9 mm at 90% confidence level. Conclusions: The 3D surface imaging system is capable of detecting rigid setup errors with good accuracy for head-and-neck cancer. Further investigations are needed to improve the accuracy in detecting nonrigid setup errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SILVER: Surface Imaging for Lunar Volatiles, Resources, and Exploration

The Surface Imaging for Lunar Volatiles, Exploration, and Resources (SILVER) instrument is a proposed imaging investigation for the 2008 Lunar Reconnaissance Orbiter (LRO) mission. SILVER and its experienced Measurement Team will prepare for and support future lunar human exploration activities, especially landing site identification and certification on the basis of potential resources. SILVER combines a high-resolution pushbroom visible imaging channel (SILVER-HR) and a wide-field-of-view (45 deg) framing imaging channel (SILVER-WF). SILVER-HR will obtain a single-detector 6 km imaging swath of 12,228 pixels at 0.5 m/pixel to image greater than 100 sq km target areas from 50 km altitude, imaging greater than 15% the lunar surface during a 1 year nominal mission. SILVER-HR has excellent stray-light rejection and its imaging detector has selectable time delay integration (TDI) with up to 128 stages for extreme low-light sensitivity, permitting direct imaging of permanently shadowed polar regions in scattered sunlight or earthshine. SILVER-WF will obtain geodetic framing images in a 2048 x 2048 format at 20m/pixel, with 60% along-track overlap stereo for imaging context and for derivation of a global digital elevation model of meter-scale lunar topography.

Pappalardo, R. T.↗

Surface Imaging Skin Friction Instrument and Method

A surface imaging skin friction instrument allowing 2D resolution of spatial image by a 2D Hilbert transform and 2D inverse thin-oil film solver, providing an innovation over prior art single point approaches. Incoherent, monochromatic light source can be used. The invention provides accurate, easy to use, economical measurement of larger regions of surface shear stress in a single test.

Brown, James L.↗

SU-C-BRF-02: Surface Imaging Based Analysis of Intra-Fraction Motion for Breast Radiotherapy Patients

Purpose: To quantify and characterize intrafraction motion for breast radiotherapy treatments using 3D surface imaging. Methods: Thirty free breathing breast patients were monitored with 3D surface imaging over a total of 831 monitoring sessions. Mean translations and rotations were calculated over each minute, each session, and over all sessions combined. The percentage of each session that the root mean square (RMS) of the linear translations were outside of 2 mm, 3 mm, 4 mm, and 5 mm were determined for each patient. Correlations between mean translations per minute and time and between standard deviation per minute and time were evaluated using Pearson's r value. Results: The mean RMS translation averaged over all patients was 2.63 mm +/- 1.63 mm. The patients spent an average of 52%, 24%, 11%, and 5% of the monitoring time outside of 2 mm, 3 mm, 4 mm, and 5 mm RMS tolerances, respectively. The RMS values averaged over all patients were 2.95 mm +/- 1.67 mm, 3.21 +/- 2.11, and 3.57 mm +/- 2.23 mm over the 5th, 10th, and 15th minutes of monitoring, respectively. The RMS values (r = 0.95, p = 0) and the standard deviations of the RMS values (r = 0.97, p = 0) both showed strong significant correlations with time. Conclusion: The majority of patients treatment time is spent within 5 mm of the isocenter. Patient position tends to drift with increasing time in the session. Treatment length should be considered when determining planning margins. An 8 mm margin on a target volume would account for two standard deviations of motion for a treatment up to 15 minutes in length.

60 APPLIED LIFE SCIENCES↗

SU-E-J-171: Surface Imaging Based Intrafraction Motion Assessments for Whole Brain Radiotherapy

Purpose: To quantify and characterize intrafraction motion for whole brain radiotherapy treatments in open face masks using 3D surface imaging. Methods: Fifteen whole brain patients were monitored with 3D surface imaging over a total of 202 monitoring sessions. Mean translations and rotations were calculated over each minute, each session, and over all sessions combined. The percentage of each session that the root mean square (RMS) of the linear translations were outside of 2 mm, 3 mm, 4 mm, and 5 mm were determined for each patient. Correlations between mean translations per minute and time and between standard deviation per minute and time were evaluated using Pearson's r value. Results: The mean RMS translation averaged over all patients was 1.45 mm +/− 1.52 mm. The patients spent an average of 18%, 10%, 6%, and 3% of the monitoring time outside of 2 mm, 3 mm, 4 mm, and 5 mm RMS tolerances, respectively. The RMS values averaged over all patients were 1.31 mm +/− 0.98 mm, 1.52 +/- 1.04, and 1.30 mm +/− 0.71 mm over the 1th, 5th, and 10th minutes of monitoring, respectively. Neither, the RMS values (p = 0.15) or the standard deviations of the RMS values (p = 0.16) showed significant correlations with time. Conclusion: The patients were positioned within 2 mm of isocenter, which was the initial set-up tolerance, for the majority of their treatments. The average position changed by < 0.3 mm over 10 minutes of monitoring. Short term movements, reflected by the standard deviations, where on the order of 1 mm. This immobilization system provides adequate immobilization over a course of treatment for whole brain radiotherapy. This system may also be suitable for head and neck or stereotactic radiosurgery treatments as well.

60 APPLIED LIFE SCIENCES↗

SU-E-J-139: One Institution’s Experience with Surface Imaging in Proton Therapy

Purpose: X-ray system is commonly used for IGRT in proton therapy, however image acquisition not only increases treatment time but also adds imaging dose. We studied a 3D surface camera system (AlignRT) performance for proton therapy. Methods: System accuracy was evaluated with rigid phantom under two different camera location configurations. For initial clinical applications, post mastectomy chest wall and partial breast treatments were studied. X-ray alignment was used as our ground truth. Our studies included: 1) comparison of daily patient setup shifts between X-ray alignment and SI calculation; 2) interfractional breast surface position variation when aligning to bony landmark on X-ray; 3) absolute positioning using planning CT DICOM data; 4) shifts for multi-isocenter treatment plan; 5) couch isocentric rotation accuracy. Results: Camera locations affected the system performance. After camera relocation, the accuracy of the system for the rigid phantom was within 1 mm (fixed couch), and 1.5 mm (isocentric rotation). For intrafractional patient positioning, X-ray and AlignRT shifts were highly correlated (r=0.99), with the largest difference (mean ± SD) in the longitudinal direction (2.14 ± 1.02 mm). For interfractional breast surface variation and absolute positioning, there were still larger disagreements between the two modalities due to different focus on anatomical landmarks, and 95% of the data lie within 5mm with some outliers at 7 mm–9 mm. For multi-isocenter shifts, the difference was 1 ± 0.56 mm over an 11 cm shift in longitudinal direction. For couch rotation study, the differences was 1.36 ± 1.0 mm in vertical direction, 3.04 ± 2.11 mm in longitudinal direction, and 2.10 ± 1.66 mm in lateral direction, with all rotation differences < 1.5 degree. Conclusion: Surface imaging is promising for intrafractional treatment application in proton therapy to reduce X-ray frequency. However the interfractional discrepancy between the X-ray and SI requires future validation.

60 APPLIED LIFE SCIENCES↗

SU-F-J-22: Lung VolumeVariability Assessed by Bh-CBCT in 3D Surface Image Guided Deep InspirationBreath Hold (DIBH) Radiotherapy for Left-Sided Breast Cancer

Purpose: With the increasing use of DIBH techniques for left-sided breast cancer, 3D surface-image guided DIBH techniques have improved patient setup and facilitated DIBH radiation delivery. However, quantification of the daily separation between the heart and left breast still presents a challenge. One method of assuring separation is to ensure consistent left lung filling. With this in mind, the aim of this study is to retrospectively quantify left lung volume from weekly breath hold-CBCTs (bh-CBCT) of left-sided breast patients treated using a 3D surface imaging system. Methods: Ten patients (n=10) previously treated to the left breast using the C-Rad CatalystHD system (C-RAD AG, Uppsala Sweden) were evaluated. Patients were positioned with CatalystHD and with bh-CBCT. bh-CBCTs were acquired at the validation date, first day of treatment and at subsequent weekly intervals. Total treatment courses spanned from 3 to 5 weeks. bh-CBCT images were exported to VelocityAI and the left lung volume was segmented. Volumes were recorded and analyzed. Results: A total of 41 bh-CBCTs were contoured in VelocityAI for the 10 patients. The mean left lung volume for all patients was 1657±295cc based on validation bh-CBCT. With the subsequent lung volumes normalized to the validation lung volume, the mean relative ratios for all patients were 1.02±0.11, 0.97±0.14, 0.98±0.11, 1.02±0.01, and 0.96±0.02 for week 1, 2, 3, 4, and 5, respectively. Overall, the mean left lung volume change was ≤4.0% over a 5-week course; however left lung volume variations of up to 28% were noted in a select patient. Conclusion: With the use of the C-RAD CatalystHD system, the mean lung volume variability over a 5-week course of DIBH treatments was ≤4.0%. By minimizing left lung volume variability, heart to left breast separation maybe more consistently maintained. AN Gutierrez has a research grant from C-RAD AG.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP3-02: Comparison of Magnitude and Frequency of Patient Positioning Errors in Breast Irradiation Using AlignRT 3D Optical Surface Imaging and Skin Mark Techniques

Purpose: To evaluate clinical usefulness of AlignRT (Vision RT Ltd., London, UK) in reducing patient positioning errors in breast irradiation. Methods: 60 patients undergoing whole breast irradiation were selected for this study. Patients were treated to the left or right breast lying on Qfix Access breast board (Qfix, Avondale, PA) in supine position for 28 fractions using tangential fields. 30 patients were aligned using AlignRT by aligning a breast surface region of interest (ROI) to the same area from a reference surface image extracted from planning CT. When the patient’s surface image deviated from the reference by more than 3mm on one or more translational and rotational directions, a new reference was acquired using AlignRT in-room cameras. The other 30 patients were aligned to the skin marks with room lasers. On-Board MV portal images of medial field were taken daily and matched to the DRRs. The magnitude and frequency of positioning errors were determined from measured translational shifts. Kolmogorov-Smirnov test was used to evaluate statistical differences of positional accuracy and precision between AlignRT and non-AlignRT patients. Results: The percentage of port images with no shift required was 46.5% and 27.0% in vertical, 49.8% and 25.8% in longitudinal, 47.6% and 28.5% in lateral for AlignRT and non-AlignRT patients, respectively. The percentage of port images requiring more than 3mm shifts was 18.1% and 35.1% in vertical, 28.6% and 50.8% in longitudinal, 11.3% and 24.2% in lateral for AlignRT and non-AlignRT patients, respectively. Kolmogorov-Smirnov test showed that there were significant differences between the frequency distributions of AlignRT and non-AlignRT in vertical, longitudinal, and lateral shifts. Conclusion: As confirmed by port images, AlignRT-assisted patient positioning can significantly reduce the frequency and magnitude of patient setup errors in breast irradiation compared to the use of lasers and skin marks.

60 APPLIED LIFE SCIENCES↗

Intermodulation electrostatic force microscopy for imaging surface photo-voltage

We demonstrate an alternative to Kelvin Probe Force Microscopy for imaging surface potential. The open-loop, single-pass technique applies a low-frequency AC voltage to the atomic force microscopy tip while driving the cantilever near its resonance frequency. Frequency mixing due to the nonlinear capacitance gives intermodulation products of the two drive frequencies near the cantilever resonance, where they are measured with high signal to noise ratio. Analysis of this intermodulation response allows for quantitative reconstruction of the contact potential difference. We derive the theory of the method, validate it with numerical simulation and a control experiment, and we demonstrate its utility for fast imaging of the surface photo-voltage on an organic photo-voltaic material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗