Search NASA⌕ Search

SEARCH · Search NASA

Results for “Surface thermocouples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Advanced Multiphysics Code Coupling for Cladding Surface Thermocouples During Two-Phase Heat Transfer from Nuclear Fuel

Transient testing of nuclear fuel involves the evaluation of fuel performance under off-normal and accident conditions and is essential for proving design performance. Instrumentation included in such experiments commonly includes thermocouples attached to the outer surface of the cladding to provide temperature measurements throughout the transient. However, the presence of thermocouples on the cladding surface can alter the local heat transfer characteristics with the surrounding coolant. These localized effects can influence the temperature of the nearby cladding surface and introduce uncertainties in interpreting the thermocouple data. Understanding the impact of thermocouples attached to the outer surface of the cladding is crucial for accurate data interpretation as well as its effect on the thermomechanical behavior of the cladding. This paper presents a novel methodology for simulating the impact of outer cladding thermocouples during transient testing of nuclear fuels. The simulation framework leverages the thermal-hydraulic capabilities of RELAP5-3D coupled to the BISON fuel performance code through the RELAPCouplingApp interface. The methodology is compared against Accident Tolerant Fuel Reactivity Initiated Accident-1-E experiment performed at Idaho National Laboratory. The results reveal approximately 100°C difference between thermocouple-altered temperature and virgin cladding surface. The model overpredicts surface rewet time due to conservative correlations.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design and Implementation of Surface Eroding Thermocouples for Stage-One Modular Divertor Integration at the DIII-D Tokamak

The DIII-D has upgraded its upper divertor to a modular system using copper alloy pedestals to alter the divertor geometry without changing the vessel structure. Six new graphite tiles were designed for the shape and volume rise (SVR) divertor. Here, these new SVR tiles facilitated the formation of a poloidal array of 27 surface eroding thermocouples (SETCs) in the upper divertor region. At one location, a specialized recessed SETC, paired with a standard flush SETC, was installed in one of the ceiling tiles to provide comprehensive heat flux measurements, distinguishing between charged and noncharged particle contributions. Upgrades were made to the SETC system in the small-angle slot (SAS) divertor to improve overall performance. These upgrades included optimizing the feedthrough system to double the thermocouple cable capacity and reallocating cables from the SAS area to the SVR divertor. A compact isolation amplifier system with a fixed gain of 41 was employed to improve the signal level and minimize interference. Additionally, two analog-to-analog fiber systems were implemented for transmitting thermocouple signals over a single fiber, significantly reducing both noise levels and costs. The newly installed SETCs in the SVR divertor successfully completed initial commissioning testing. The SETCs captured the in-out asymmetry in the power distribution between the inner and outer strike points and demonstrated the dependency of the heat flux profile on the outer strike point location. During divertor detachment, heat flux mitigation was noted at the outer strike point location, while significant heat flux contributions from neutral particles were measured in the SVR divertor.

Divertor↗

Surface normal emissivity measurements in uncoated and oxidized B-coated plasma facing component materials in the long wavelength infrared spectrum

Accurate surface emissivity measurements are integral to the fidelity of the infrared thermography diagnostic evaluation in fusion reactors. The emissivities of ATJ TM graphite, Sigrafine® (R6510) graphite, and TZM alloy were measured as a function of temperature in accordance with the Contact Thermometer Method in the ASTM E1933 standard. Samples were heated resistively in a high-vacuum chamber, and the surface temperature was monitored using a surface thermocouple and a Telops long-wavelength infrared camera. The surfaces of Sigrafine® graphite and TZM alloy samples were coated with 10 nm and 20 nm layers of oxidized boron and were also measured in the uncoated condition. The thickness was assessed from measurement by a quartz crystal microbalance (QCM). ATJ TM graphite was uncoated. The measured emissivity of ATJ TM Graphite ranged from 0.82 to 0.83, uncoated Sigrafine® graphite ranged from 0.76 to 0.98, and uncoated TZM alloy ranged from 0.11 to 0.13. Oxidized boron coatings increased the emissivity of the TZM alloy to 0.18–0.23 but decreased the emissivity of Sigrafine® graphite to 0.56–0.66 for a 10 nm coating and to 0.65–0.74 for a 20 nm coating. In contrast to the expected blackbody radiance, the emissivity of uncoated Sigrafine® graphite and TZM alloy did not monotonically increase with temperature from 100 to 500 ℃.

Emissivity↗

The effectiveness of D 2 pellet and gas injection in reducing intra-ELM tungsten erosion and heat flux in the DIII-D small angle slot divertor

Edge localized modes (ELMs) in H-mode plasmas can melt and erode plasma-facing components (PFCs) and lead to impurities in the core, reducing confinement. This study analyzes the use of D 2 pellet and gas injection for ELM mitigation on the DIII-D tokamak during the 2022 Small Angle Slot V-shaped Tungsten (W) (SAS-VW) divertor campaign, reducing W erosion and heat flux during ELMs. D α (656 nm) and WI (400.9 nm) filterscopes and Langmuir probes provide photon emission and electron density/temperature to estimate W atom erosion using the S/XB method, while surface eroding thermocouples measured ELM peak heat flux at the outer strike point (OSP). Thomson Scattering measurements of pedestal T e and n e provided input to predict W divertor erosion and heat flux during ELMs via the Free-Streaming plus Recycling Model (FSRM). While a greater D 2 mass injection rate decreased the ELM peak heat flux, the impact on W erosion was not monotonic. The average ‘large’ intra-ELM W erosion was lower for plasma shots with D 2 mass injection compared to the plasma shots without any D 2 mass injection in the SAS-VW divertor. However, plasma shots did not see significant changes in ‘large’ intra-ELM W divertor erosion as the D 2 mass injection rate increased. On average, the FSRM overestimated SAS-VW experimental intra-ELM W erosion by a factor of 6.9, but the overestimation is reduced to a factor of 3.6 with the implication of C deposition effects. Generally, experimentally measured and predicted quantities were worse for plasma shots with a lower D 2 mass injection rate and corresponding higher plasma carbon (C) impurity percentage (f C ). The discrepancies are postulated to be due to C/W material mixing, for which a simple analytic mixed-material model is presented. These results highlight the importance of incorporating and improving the robustness of a mixed-material layer model in the analysis of PFC erosion on present and future tokamak devices.

Carbon (C)↗

Non-intrusive temperature measurements in the vicinity of a thermocouple using synchrotron x-ray fluorescence

A highly spatially resolved synchrotron x-ray fluorescence (XRF) thermometry technique has been used to map temperature fields around a 125 mu m type R thermocouple immersed in a stoichiometric premixed methane flame. The high spatial resolution of the XRF technique allowed temperatures to be measured close to the thermocouple and the impact of the thermocouple on the flame to be assessed. This paper discusses some of the nontrivial challenges of these measurements including the recovery of spectral features from the krypton fluorescent agent that are overlapped by those from the thermocouple metals at locations near the bead surface. The calculated temperatures from 1D premixed flame simulations are in excellent agreement with measurements along the centerline. The results show that the 125 mu m thermocouple induces minimal disturbances to the gas flow and any catalytic effects originating from the bare wires are also inconsequential. Here, the methodology has advanced to a stage where it enables comparisons between the gas temperature in the vicinity of the thermocouple and the actual thermocouple reading.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Department of Transportation PHMSA Aerosol Spray Project: Phase-0

This report discusses the work conducted at Sandia National Laboratories during the preliminary phase (Phase-0) of the Department of Transportation (DOT) Pipeline and Hazardous Materials Safety Administration (PHMSA) project tasked to better understand what happens to a high-pressure liquid canister or vessel during a fire in which an accidental instantaneous release occurs. Phase 0 had two main objects: (1) to establish a methodology for the high temperature and pressure spray vessel release and (2) to characterize the spray droplet formation. For this test series, diagnostic equipment such as the Malvern Spraytec, high-speed photometric cameras, pencil gauges, and thermocouples were used. Additionally, the effect of surface tension on the particle size distribution was evaluated with 1-liter of distilled water and with the same including the addition of 0.5% soap/water mixture. Results from this effort indicated that the plume formed from the instantaneous release in all conditions primarily included two distinct particle size distributions including 217-312µm and 0.53µm on average. Soapy water formed a higher concentration of smaller mist (0.53µm) than distilled water, potentially due to decreased surface tension with the added surfactant. Though results showed good correlation to certain particle size distributions it is encouraged to conduct additional tests like this with a wider range of liquids with different properties, which could affect the overall particle size distribution when released.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Leveraging MARVEL and SPHERE to Demonstrate NEAMS Thermal Hydraulics Codes

The Single Primary Heat Extraction and Removal Emulator (SPHERE) and Microreactor Applications Research Validation and Evaluation (MARVEL) were utilized to demonstrate thermal hydraulics codes of the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. A recent long-duration test of a sodium heat pipe conducted at the SPHERE facility was utilized for the validation of the heat pipe code Sockeye. The first 10 hours of operation featured a startup of the heat pipe from room temperature; this portion was modeled with Sockeye and compared to the experimental data. Measurements included several thermocouple measurements across the length of the heat pipe surface. Two of Sockeye’s heat pipe models were applied to experiment, as well as several models of the cooling at the condenser end of the heat pipe. Sockeye results gave a decent match to the experimental data, with notable discrepancy in the condenser section, where experimental data indicated a significant inactive length of the heat pipe. The MARVEL microreactor was modeled through a coupled simulation of System Analysis Module (SAM) and SubChannel Module (SCM). This multiscale coupled simulation was performed as an exercise to demonstrate the compatibility and applicability of these codes for thermal-hydraulic analysis of microreactors. The coupling between the SCM and SAM codes for multiscale modeling of MARVEL, was achieved through a domain overlapping approach. In this example a transient SAM simulation provided boundary conditions to SCM, and SCM provided pressure drop to SAM.

97 - MATHEMATICS AND COMPUTING↗

Wrought FeCrAl alloy (C26M) cladding behavior and burst under simulated loss-of-coolant accident conditions

Cladding burst experiments for FeCrAl cladding were performed in the Severe Accident Test Station facility at Oak Ridge National Laboratory. These experiments were simulated using the BISON fuel performance code to better understand the cladding plastic behavior and failure under simulated loss-of-coolant accident conditions. 3D cladding surface boundary conditions were generated using composite axial and azimuthal profiles from experiment thermocouple data. To improve the simulation analysis capabilities in BISON for cladding burst behavior, new thermal creep, plasticity, and failure stress models specific to C26M, a wrought FeCrAl alloy, were developed and implemented. Initial cladding burst results indicated a general underprediction in the failure temperature of the six cladding burst simulations versus the observed failure temperatures. Close investigation of the experiment timing versus the underlying tensile test data revealed that, compared with the tensile specimens, the cladding tubes did not experience the same long holding time at high temperatures. New tensile tests were performed at high temperatures using a temperature ramp similar to the simulated loss-of-coolant accident experiments. These new tensile curves showed an approximately 80% increase in the ultimate tensile strength of the C26M alloy, indicating that a holding time of 10 min at 700 °C and 800 °C allows annealing to change the material microstructure. Using the updated tensile properties, the burst temperatures and stresses from the simulations showed remarkable agreement with the experimental results. This study was then extended by varying the initial pressure to highlight the burst temperature difference between standard Zircaloy-4 and C26M cladding under equivalent conditions. The results show that C26M has a burst temperature that is approximately 70–130 K greater than that of Zircaloy-4. In conclusion, these modeling predictions can be further improved by collecting high-temperature tensile data for C26M beyond the temperature ranges used in this work.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NPFTURBULENCE: Turbulent Parameters by airborne measurements

The original data were collected during the field campaign of “Turbulent layers promoting New Particle Formation” experiment (NPFTURBULENCE; https://www.arm.gov/research/campaigns/aaf2024npfturbulence) over the Atmospheric Radiation Measurement (ARM) user facility's Southern Great Plains (SGP) atmospheric observatory (https://www.arm.gov/capabilities/observatories/sgp ) in north-central Oklahoma. The ARM Aerial Facility ArcticShark uncrewed aerial system (UAS, https://www.arm.gov/capabilities/observatories/aaf/uas) was based at Blackwell–Tonkawa Municipal Airport (IATA: BWL, ICAO: KBKN, FAA LID: BKN, 36.74475° N, 97.34918° W, 313.9 m MSL), for the field campaign from May 5 through May 29, 2024. The ArcticShark UAS performed 11 flights, including 10 research flights over the Central Facility of the ARM SGP to measure atmospheric state, turbulence, surface IR temperature and imagery, and aerosol number concentration and size distribution. The current data set presents a comprehensive collection of turbulent parameters in the atmospheric boundary layer or lower free troposphere based on airborne measurement throughout the field campaign. The primary instruments used to create the current data set were the Aircraft Integrated Meteorological Measurement System (AIMMS-30) and the fine-wire thermocouple probe. For user convenience, the current data set includes several parameters commonly used in turbulent research for normalization and/or scaling: atmospheric boundary-layer height, surface conditions, convective scales for temperature, and velocity, etc.

54 ENVIRONMENTAL SCIENCES↗

Thermocouple and RTD Drift Due to Neutron Irradiation and Temperature for Space Nuclear Applications: A Review

Temperature measurement is a key factor in the safe and reliable operation of nuclear reactors. Thermocouples and resistance temperature detectors (RTDs) are among the most common and reliable tools deployed for temperature measurement, and some are capable of operating in extreme environments such as very high temperature and neutron radiation fields anticipated in nuclear thermal propulsion (NTP) or fission surface power. These devices are known to exhibit drifting behavior in their temperature readings throughout their operational lifetimes. Here, to help select appropriate instrumentation, it is important to identify the factors that influence drift as well as typical behavior in these environments. This work is focused on identifying contributing factors in the performance of thermocouples and RTDs. An extensive literature review is included that discusses several experimental results in different environments. Although individual instrument performance may vary with construction methods, materials selection, and vendors, this review aims to assist in the selection process and identify typical expected behaviors of several devices.

Chesser, Ryan J. [Oak Ridge National Laboratory (O↗

Emissivity measurements of CuCrZr alloy

The Facility for Rare Isotope Beams (FRIB) heavy-ion accelerator, in user operation since 2022, produces rare isotope beams via interactions of high-intensity stable ion beams with a graphite production target. Approximately 20–40% of the primary beam power is deposited in the target, while the remaining 60–80% is absorbed by the beam dump. The minichannel beam dump (MCBD), currently operated at 20 kW and designed for operation up to 50 kW, uses CuCrZr alloy absorber plates. Thermal validation and thermal cycling tests of the MCBD were conducted at the Applied Research Laboratory (ARL) at Pennsylvania State University. Temperature measurements were obtained from an infrared (IR) camera. Since accurate temperature determination requires reliable emissivity values, the emissivity of CuCrZr was measured using the IR camera validated against thermocouple reference temperatures up to approximately 650 °C. The measurements were conducted under a vacuum level of approximately 10 -5 torr to minimize emissivity variations due to surface oxidation. The emissivity of CuCrZr was determined to be 0.057 ± 0.009 using a constant fit to the measured data over the surface temperature range from 100–650 °C.

Accelerator Subsystems and Technologies↗

Experimental investigation of a closed vapour box module for a divertor-like configuration in Magnum-PSI

Efficient management of extreme heat fluxes in the divertor region to extend the lifetime of the components remains a critical challenge for the realization of nuclear fusion-based power plants. Among the alternative concepts explored for the divertor region, the use of liquid metals, particularly lithium, is of interest due its ability to dissipate the incoming plasma heat flux through the vapour shielding effect (VS). In this work, we experimentally investigated a ‘closed’ configuration of a dedicated Vapour Box Module (VBM) in the linear plasma device Magnum-PSI. The goal of the experiments is to simulate the vapour box divertor environment conditions and assess its performance in terms of power mitigation and redistribution and lithium confinement. Initial testing without Li demonstrated the efficacy of a closed VBM structure in inducing detachment via neutral gas accumulation. Apertures which enabled non-condensing gas to be effectively pumped while ensuring lithium condensed on the inner surfaces were therefore added. With a lithium capillary porous structure target used, lithium is directly vaporized by the plasma, forming a dense lithium vapour cloud that interacts with the incoming plasma. This resulted in a significant reduction of the target temperature of at least 48%, together with a temperature locking effect, a phenomenon typically observed in the VS regime. Lithium vapour confinement within the VBM was strongly correlated with the wall temperature. Relatively cold walls promoted Li re-condensation and therefore improved Li confinement, although with the expected trade-off of increased hydrogenic retention on lithium-wetted surfaces. As the wall temperature increased, the confinement efficiency decreased, consistent with reduced Li re-condensation and thermally activated Li–H chemistry and remobilization at the walls. Diagnostic measurements through embedded thermocouples and calorimetry revealed that lithium vaporization and re-condensation processes also playedsignificant roles in plasma power dissipation. The results advance the case for a closed divertor chamber with direct lithium evaporation from the strike-points as a viable method to manage divertor heat fluxes in future fusion reactors.

Romano, Fabio [Dutch Institute for Fundamental Ene↗

TRUST Sensors in Environments: Thermocouples (SE-TC), Release FY25

The Delivery Environments Testbeds to Reduce Uncertainty in Simulations and Tests (TRUST) project is a broad project intended to analyze simplified problems experimentally and with modeling and simulation. The purpose of analyzing these simplified problems is to extend solution methods to more complex problems, as well as understand deficiencies and gaps in knowledge of methods currently used in more complex analyses. The TRUST project encompasses several smaller testbeds intended to isolate individual phenomena. The testbed under consideration in this report is the Sensors in Environments: Thermocouples testbed. In previous years, the purpose of this testbed was to quantify uncertainty of thermocouple sensors. To accomplish this, an aluminum plate was placed in a thermal chamber and subject to various types of thermal loading. Thermocouples were placed in various locations on the aluminum plate in various configurations (e.g., embedded in the plate, placed under Kapton tape), and an effort was made to quantify uncertainty in these measurements. Finite element simulations were performed to investigate how sensitive these measurements were to parameters such as the boundary conditions on the plate and material properties. However, a fundamental source of uncertainty in this analysis was the convective heat transfer from the plate. Convective heat transfer is a complex physical phenomenon comprised of a number of interacting sub-processes and is difficult to predict accurately a priori. As such, the main purpose of this testbed in FY25 was to better understand, both experimentally and numerically, the convective heat transfer from the plate. This is a highly applicable problem to several more complex problems, as convective heat transfer occurs in nearly all problems where a body is moving through air. Numerically, this required a two-step approach. First, the air flow in the thermal chamber was in vestigated using computational fluid dynamics. The commercial solver Fluent was used to perform these simulations. From these simulations, a heat transfer coefficient over the surface of the plate was calculated. This heat transfer was then used as boundary conditions for finite element heat transfer simulations within the plate, which were performed using Abaqus. Significant effort was devoted to automating the handoff between these two solvers. Experimentally, previous thermocouple results in the plate were used to validate the time-dependent thermal profiles produced from Abaqus. Further experimental efforts were performed both to help validate the Fluent simulations and to inform its boundary conditions. For example, hot-wire anemometers were used to measure the velocity in the chamber, which would be particularly useful in understanding the chamber inlet velocity. Thermocouple measurements were also taken in the chamber, instead of only on the plate, to serve as validation evidence for the Fluent simulations. Numerical results showed that the Fluent to Abaqus workflow matched previous plate thermocouple measurements well. This type of handoff is useful for more complex experiments, or those that are not able to be examined in as great of detail as this testbed, as it was performed without any experimental input. Experimental results, however, were more mixed. The anemometers proved unreliable, with inconsistent measurements across all anemometers, even at locations that were nearly identical. On the other hand, the thermocouples provided a relatively rich view of the temperature field in the chamber.

42 ENGINEERING↗

The right conditions for high-precision dynamic temperature and heat capacity measurement via pyrometry and conductivity

The pursuit of accurate bulk temperature T under extreme conditions has been a long-standing goal of the high pressure science community, complicated by a lack of data to inform models. To reach these extremely high-pressure, high-temperature (high P − T) conditions, a combination of dynamic and heated static experiments (e.g., diamond or gem anvil cel experiments) are used. For example, in a diamond anvil cell (DAC) experiment, a sample placed in the DAC is first pressurized. Following pressurization, the sample T is increased either by heating the entire DAC (usually using resistive heating, and limited to ∼1000K) or by applying intense laser power to the sample surfaces. In a dynamic experiment, the process of pressurizing the sample also heats it. In the case of shock physics experiments, such heating is substantial, easily reaching thousands of Kelvin; in our work we have seen T ∼17000K. Most methods of measuring temperature at ambient are not compatible with experiments under these high-pressure, high-temperature conditions: thermocouples break, melt, or have conductivity properties that differ from ambient where they are calibrated; thermometers would melt; both are too slow. As a result most methods are based on non-contact techniques such as x-ray diffraction broadening, neutron scattering, or optical methods. Of these, optical methods using the visible and near-infrared region of the spectrum are the most commonly used as the sources and detectors are readily available. In the case of optical methods the optical depth, and therefore the measurement location, is limited to the surface. When a window or anvil material is used, heat flows from the sample into the window/anvil. Likewise, if the sample undergoes a change in thermodynamic state, such as expansion upon release, different T may be expected. As a result, the surface or apparent temperature T app measurement will differ from the bulk or interior temperature that is desired. This surface measurement must be related to the bulk measurement using thermal transport models and material models. While it is tempting to conclude that one should just use x-ray methods that directly probe the interior, even these methods have been shown to depend on thermal transport and material models. Regardless of the method used to create the high P − T condition, therefore, we must understand the role of thermal transport and material models upon our interpretation of the T measurement, as well as the errors and uncertainties associated with the choice of models used in the analysis. This is a substantial area of research and this paper is by no means a complete survey of the relevant sources of uncertainty. For example, we have yet to begin to address alternate transport models in a detailed manner (e.g., Tan-Ahrens), or the many models that use additional layers to approximate melting, turbulence, or epitaxial phenomena). Likewise, we have not explored the impact upon uncertainty of thermal models that use temperature-dependent thermal transport coefficients, or the wide range of material models that can be applied. Instead, this paper focuses on using one simple model, the Urtiew-Grover model, to understand the sources of error in T measurement so that we may identify how best to focus future research efforts to return the best improvements and avoid working on over-optimizing a single type of measurement. To this end, we work through some of the best and worst case scenarios for T measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental analysis of conductive drying of paper and board

The primary heat transfer source in the conventional multi-cylinder drying of paper and board is conduction. Conduction is facilitated by high-tension contact with steam-heated cylinders, while convective drying, the main mass transfer source, operates as heated air flows over the paper web in the pockets. This conduction process occurs at elevated temperatures and contact pressures to ensure effective contact between the wet paper web and the heated cylinders. The contact pressures and temperatures of the hot surface significantly influence the conductive drying characteristics. This research paper presents an experimental study that involves designing a simple lab-scale setup with in-situ and continuous sensing capabilities for various commercially available grades of paper and board. Embedded thermocouples measure the temperatures of the heated platen and the sheet, allowing the collection of flux data to determine heat transfer characteristics. Here, the goal of this study is to ascertain the instantaneous contact coefficients for different basis weights as a function of moisture content. The acquired data will provide valuable insights and information towards process development, design and simulation of the paper drying process.

42 ENGINEERING↗

Molecular beam epitaxy growth and characterization of GePb alloys

Pb based group-IV alloys such as GePb have been gaining interest as a potential alternative for infrared detectors, quantum materials, and high-speed electronic devices. Challenges remain in their growth due to the extremely low solid solubility of Pb in the Ge–Pb system. This paper reports molecular beam epitaxy growth of GePb alloy thin films on Ge(100) substrates. Effusion cells of Ge and Pb are used to control the flux ratio independently. The optimal substrate temperature is found to be near the thermocouple temperature of 300 °C based on the characterization of the grown films using high-resolution x-ray diffraction. A large change in the Ge:Pb beam equivalent pressure ratio from 10:1 to 1:1 results in only a minimal increase of the Pb composition from 0.74% to 2.84% as estimated from Raman spectroscopy and Rutherford backscattering spectrometry. Furthermore, scanning electron microscopy images show a large volume of Pb islands on the surface that form into either long trapezoidal rods or uniform droplets, with increasing Pb flux and growth time the density of Pb islands increased.

36 MATERIALS SCIENCE↗

NPFTURBULENCE: Fast Response Temperature by Airborne Measurements

The original data were collected during the field campaign of the “Turbulent layers promoting New Particle Formation” experiment (NPFTURBULENCE; https://www.arm.gov/research/campaigns/aaf2024npfturbulence; https://www.arm.gov/publications/programdocs/doe-sc-arm-25-004.pdf ) over the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) Atmospheric Observatory (https://www.arm.gov/capabilities/observatories/sgp ) in north-central Oklahoma. The ARM Aerial Facility ArcticShark uncrewed aerial system (UAS, https://www.arm.gov/capabilities/observatories/aaf/uas) was based at Blackwell–Tonkawa Municipal Airport (IATA: BWL, ICAO: KBKN, FAA LID: BKN, 36.74475° N, 97.34918° W, 313.9 m MSL), for the field campaign from May 5 through May 29, 2024. The ArcticShark UAS performed 11 flights, including 10 research flights over the Central Facility of the ARM SGP to measure atmospheric state, turbulence, surface IR temperature and imagery, aerosol number concentration and size distribution. The current dataset presents fast response temperature in the atmospheric boundary layer and lower free troposphere measured on the airborne platform throughout the field campaign. The primary instruments used to create the current dataset were the fine wire thermocouple probe, Pitot-static system (part of the UAS control), and infrared gas analyzer sensor for H2O and CO2 (LI-840A). All parameters used in the temperature calculations (static and dynamic pressure, absolute humidity in form of dew point temperature) were included in the data set. For user convenience, one additional parameter was also included: the type of flight flag (level, up, down, turn, and combination of thereof).

Air temperature↗

Fast Response Temperature by airborne measurements over BNF

The original data were collected during the AAF Engineering Flights (AEF2025) in the vicinity of the ARM Bankhead National Forest (BNF) Atmospheric Observatory (https://www.arm.gov/capabilities/observatories/bnf ) in northwestern Alabama in March 2025. The ARM Aerial Facility ArcticShark uncrewed aerial system (UAS, https://www.arm.gov/capabilities/observatories/aaf/uas) was based at the public-use airport of Posey Field, Alabama (FAA LID: 1M4, 34.28027778° N, 87.60055556° W, 283m MSL) from March 9 through March 24, 2025. The ArcticShark UAS performed nine flights, including eight research flights over the AMF3 (BNF Main Site) and Supplemental Facilities to measure atmospheric state, turbulence, surface IR temperature and imagery, and aerosol number concentration and size distribution. The current data set presents fast response temperature in the atmospheric boundary layer and lower free troposphere measured on the airborne platform throughout the field campaign. The primary instruments used to create the current data set were the fine wire thermocouple probe, the Aircraft Integrated Meteorological Measurement System (AIMMS-30), the Pitot-static system (part of UAS flight control), and the infrared gas analyzer sensor for H2O and CO2 (LI-840). All parameters used in temperature calculations (static pressure, True Air Speed, and absolute humidity in form of dew point temperature) were included in the data set. For user convenience, one additional parameter was also included: the type of flight flag (level, up, down, turn, and combination of thereof).

Air temperature, fast response↗