ARM: C Scanning ARM Precipitation Radar (CSAPR); Surveillance Scan
C Scanning ARM Precipitation Radar (CSAPR); Surveillance Scan
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
C Scanning ARM Precipitation Radar (CSAPR); Surveillance Scan
C Scanning ARM Precipitation Radar (CSAPR); Surveillance Scan, auxiliary data
Ka-Band Scanning ARM Cloud Radar (KASACR); Surveillance Scan
Ka-Band Scanning ARM Cloud Radar (KASACR); Surveillance Scan, auxiliary data
Objective: The aim of this study was to quantify false-positive and incidental findings from annual surveillance imaging in asymptomatic, American Joint Committee on Cancer stage III melanoma patients. Methods: This was a cohort study of patients treated at Melanoma Institute Australia (2000–2015) with baseline computed tomography (CT) or positron emission tomography (PET)/CT imaging and at least two annual surveillance scans. False-positives were defined as findings suspicious for melanoma recurrence that were not melanoma, confirmed by histopathology, subsequent imaging, or clinical follow-up, while incidental findings were defined as non-melanoma-related findings requiring further action. Outcomes of incidental findings were classified as ‘benign’ if they resolved spontaneously or were not seriously harmful; ‘malignant’ if a second malignancy was identified; or ‘other’ if potentially harmful. Results: Among 154 patients, 1022 scans were performed (154 baseline staging, 868 surveillance) during a median follow-up of 85 months (interquartile range 56–112); 57 patients (37%) developed a recurrence. For baseline and surveillance imaging, 124 false-positive results and incidental findings were identified in 81 patients (53%). The frequency of these findings was 5–14% per year, and an additional 181 tests, procedures, and referrals were initiated to investigate these findings. The diagnosis was benign in 109 findings of 124 findings (88%). Fifteen patients with a benign finding underwent an unnecessary invasive procedure. Surveillance imaging identified distant metastases in 20 patients (13%). Conclusion: False-positive results and incidental findings occur in at least half of all patients undergoing annual surveillance imaging, and the additional healthcare use is substantial. These findings persist over time. Clinicians need to be aware of these risks and discuss them with patients, alongside the expected benefits of surveillance imaging.
Evolution of precipitation structures are simulated and compared with radar observations for the November Madden-Julian Oscillation (MJO) event during the DYNAmics of the MJO (DYNAMO) field campaign. Three ground-based, ship-borne, and spaceborne precipitation radars and three cloud-resolving models (CRMs) driven by observed large-scale forcing are used to study precipitation structures at different locations over the central equatorial Indian Ocean. Convective strength is represented by 0-dBZ echo-top heights, and convective organization by contiguous 17-dBZ areas. The multi-radar and multi-model framework allows for more stringent model validations. The emphasis is on testing models' ability to simulate subtle differences observed at different radar sites when the MJO event passed through. The results show that CRMs forced by site-specific large-scale forcing can reproduce not only common features in cloud populations but also subtle variations observed by different radars. The comparisons also revealed common deficiencies in CRM simulations where they underestimate radar echo-top heights for the strongest convection within large, organized precipitation features. Cross validations with multiple radars and models also enable quantitative comparisons in CRM sensitivity studies using different large-scale forcing, microphysical schemes and parameters, resolutions, and domain sizes. In terms of radar echo-top height temporal variations, many model sensitivity tests have better correlations than radar/model comparisons, indicating robustness in model performance on this aspect. It is further shown that well-validated model simulations could be used to constrain uncertainties in observed echo-top heights when the low-resolution surveillance scanning strategy is used.
Abstract Convectively generated cold pools are important to the Earth system as they exert strong controls on deep convective-storm initiation, intensity, and life cycle. Despite their importance, efforts to introduce such cold pool controls into weather and climate models lack guidance and/or physical constraints from cold pool observations. This work presents a detailed, purely observational analysis of a cold pool event that took place on 23–24 May 2011 in north-central Oklahoma. The characteristics of the cold pool, and the spatiotemporal evolution of the hydrometeors and dynamics in the proximity of the cold pool, are studied with high-resolution observations. The unprecedented dataset used in this work to study cold pool characteristics includes an enhanced network of surface weather stations, a high-temporal-frequency sounding array, and the NEXRAD and Atmospheric Radiation Measurement (ARM) Southern Great Plains radar networks. The potential use of NEXRAD surveillance scans to estimate height and propagation speed of the leading edge of the cold pool (LECP) is presented in this work. Manual identification and tracking of the LECP from NEXRAD imagery shows a spatial and temporal heterogeneity of the LECP properties. Surprisingly, over its detected life cycle, the LECP speed remains almost constant, even though the strength of the cold pool diminishes in time and its height varies. Radar analysis shows that pulses of graupel and hail within downdrafts in the convective system generating the cold pool appeared to be related to temporary increases in the LECP height.
Evolution of precipitation structures are simulated and compared with radar observations for the November Madden-Julian Oscillation (MJO) event during the DYNAmics of the MJO (DYNAMO) field campaign. Three ground-based, ship-borne, and space-borne precipitation radars and three Cloud-Resolving Models (CRMs) driven by observed large-scale forcing are used to study precipitation structures at different locations over the central equatorial Indian Ocean. Convective strength is represented by 0-dBZ echo-top heights, and convective organization by contiguous 17-dBZ areas. The multi-radar and multi-model framework allows for more stringent model validations. The emphasis is on testing models’ ability to simulate subtle differences observed at different radar sites when the MJO event passed through. The results show that CRMs forced by site-specific large-scale forcing can reproduce not only common features in cloud populations, but also subtle variations observed by different radars. The comparisons also revealed common deficiencies in CRM simulations where they underestimate radar echo-top heights for the strongest convection within large, organized precipitation features. Cross-validations with multiple radars and models also enable quantitative comparisons in CRM sensitivity studies using different large-scale forcing, microphysical schemes and parameters, resolutions, and domain sizes. In terms of radar echo-top height temporal variations, many model sensitivity tests have better correlations than radar/model comparisons, indicating robustness in model performance on this aspect. It is further shown that well-validated model simulations could be used to constrain uncertainties in observed echo-top heights when the low-resolution surveillance scanning strategy is used.
Purpose: This study demonstrates a methodology for tracking changes in metastatic bone disease using trajectories in material basis space in serial dual energy computed tomography (DECT) studies. Methods: This study includes patients with bone metastases from breast cancer that had clinical surveillance CT scans using a General Electric CT750HD in dual energy mode. A radiologist defined regions-of-interested (ROI) for bone metastasis, normal bone, and marrow across the serial DECT scans. Our approach employs a Radon transform to forward-projection the basis images, namely, water and iodine, into sinogram space. This data is then repartitioned into fat/bone and effective density/Z image pairs using assumed energy spectrums for the x-ray energies. This approach both helps remove negative material densities and avoids adding spectrum-hardening artifacts. These new basis data sets were then reconstructed via filtered back-projection to create new material basis pair images. The trajectories of these pairs were then plotted in the new basis space providing a means to both visualize and quantitatively measure changes in the material properties of the tumors. Results: ROI containing radiologist defined metastatic bone disease showed well-defined trajectories in both fat/bone and effective density/Z space. ROI that contained radiologist defined normal bone and marrow did not exhibit any discernible trajectories and were stable from scan to scan. Conclusions: The preliminary results show that changes in material composition and effective density/Z image pairs were seen primarily in metastasis and not in normal tissue. This study indicates that by using routine clinical DECT it may be possible to monitor therapy response of bone metastases because healing or worsening bone metastases change material composition of bone. Additional studies are needed to further validate these results and to test for their correlation with outcome.
Background: The role of surveillance studies in limited-stage diffuse large B-cell lymphoma (DLBCL) in the rituximab era has not been well defined. We sought to evaluate the use of imaging (computed tomography [CT] and positron emission tomography [PET]-CT) scans and lactate dehydrogenase (LDH) in surveillance of patients with stage I to II DLBCL. Methods: A retrospective analysis was performed of patients who received definitive treatment between 2000 and 2013. Results: One hundred sixty-two consecutive patients with stage I to II DLBCL were treated with chemotherapy +/− rituximab, radiation, or combined modality therapy. The 5-year rates of overall survival (OS) and freedom from progression (FFP) were 81.2% and 80.8%, respectively. Of the 162 patients, 124 (77%) were followed up with at least 1 surveillance PET scan beyond end-of-treatment scans; of those, 94 of 124 (76%) achieved a complete metabolic response on PET scan after completion of chemotherapy, and this was associated with superior FFP (P=.01, HR=0.3) and OS (P=.01, HR 0.3). Eighteen patients experienced relapse after initial response to therapy. Nine relapses were initially suspected by surveillance imaging studies (8 PET, 1 CT), and 9 were suspected clinically (5 by patient-reported symptoms and 4 by symptoms and physical examination). No relapses were detected by surveillance LDH. The median duration from initiation of treatment to relapse was 14.3 months among patients with relapses suspected by imaging, and 59.8 months among patients with relapses suspected clinically (P=.077). There was no significant difference in OS from date of first therapy or OS after relapse between patients whose relapse was suspected by imaging versus clinically. Thirteen of 18 patients underwent successful salvage therapy after relapse. Conclusions: A complete response on PET scan immediately after initial chemotherapy is associated with superior FFP and OS in stage I to II DLBCL. The use of PET scans as posttreatment surveillance is not associated with a survival advantage. LDH is not a sensitive marker for relapse. Our results argue for limiting the use of posttreatment surveillance in patients with limited-stage DLBCL.
Purpose: To analyze CT radiation dosimetry trends in a pediatric population imaged with modern (2004-2013) CT technology Methods: The institutional review board approved this retrospective review. Two cohorts of pediatric patients that received CT scans for treatment or surveillance for Wilms tumor (n=73) or Neuroblastoma (n=74) from 2004–2013 were included in this study. Patients were scanned during this time period on a GE Ultra (8 slice; 2004–2007), a GE VCT (2008–2011), or a GE VCT-XTe (2011–2013). Each patient's individual or combined chest, abdomen, and pelvic CT exams (n=4138) were loaded onto a PACS workstation (Intelerad, Canada) and measured to calculate their effective diameter and SSDE. Patient SSDE was used to estimate patient organ dosimetry based on previously published data. Patient's organ dosimetry were sorted by gender, weight, age, scan protocol (i.e., chest, abdomen, or pelvis), and CT scanner technology and averaged accordingly to calculate population averaged absolute and effective dose values. Results: Patient radiation dose burden calculated for all genders, weights, and ages decreased at a rate of 0.2 mSv/year (4.2 mGy/year; average organ dose) from 2004–2013; overall levels decreased by 50% from 3.0 mSv (60.0 mGy) to 1.5 mSv (25.9 mGy). Patient dose decreased at equal rates for both male and female, and for individual scan protocols. The greatest dose savings was found for patients between 0–4 years old (65%) followed by 5-9 years old (45%), 10–14 years old (30%), and > 14 years old (21%). Conclusion: Assuming a linear-nothreshold model, there always will be potential risk of cancer induction from CT. However, as demonstrated among these patient populations, effective and organ dose has decreased over the last decade; thus, potential risk of long-term side effects from pediatric CT examinations has also been reduced.
Serum tumor markers (STMs) play a critical role in the diagnosis, staging and follow-up of both seminomatous and nonseminomatous testicular germ cell neoplasms. Levels of alpha-fetoprotein (AFP), human chorionic gonadotropin (HCG), and lactate dehydrogenase (LDH), especially those measured after orchiectomy, also have implications for patient prognosis. Given that testicular germ cell tumors represent the most common solid tumor in men aged 20–34, radiologists must have familiarity with the clinical utilization and implications of these STMs. This article will review the classical patterns of STM elevation most commonly seen in pure seminomatous and nonseminomatous germ cell tumors while also providing case-based examples highlighting the importance of STM correlation with imaging. The role of STMs in clinical staging and disease surveillance will also be discussed.