Search NASA⌕ Search

SEARCH · Search NASA

Results for “System control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

D-Zero Silicon Cooling System Moisture Injection System Control System

This engineering note describes the Monitoring, Controls, Interlock, and Alarm systems used to operate the Dzero Silicon Moisture Injection System that injects moisture into the Silicon Dry Air Purge System. The actual software programming is not included in this document, but the programming actions and interactions are included.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Secure control systems with application to cyber-physical systems

Control systems are computer-based systems with networked units consisting of sensors, actuators, control processing units, and communication devices. The role of control system is to interact, monitor, and control physical processes. Reactive power control is a fundamental issue in ensuring the security of the power network. It is claimed that Synchronous Condensers (SC) have been used at both distribution and transmission voltage levels to improve stability and to maintain voltages within desired limits under changing load conditions and contingency situations. Performance of PI controller corresponding to various tripping faults are analyzed for SC systems. Most of the eort in protecting these systems has been in protection against random failures or reliability. However, besides failures these systems are subject to various signal attacks for which new analysis are discussed here. When a breach does occur, it is necessary to react in a time commensurate with the physical dynamics of the system as it responds to the attack. Failure to act swiftly enough may result in undesirable, and possibly irreversible, physical eects. Therefore, it is meaningful to evaluate the security of a cyber-physical system, especially to protect it from cyber-attack. Illustrative numerical examples are provided together with an application to the SC systems.

Dong, Jin↗

Deception used for Cyber Defense of Control Systems

Control system cyber security defense mechanisms may employ deception to make it more difficult for attackers to plan and execute successful attacks. These deceptive defense mechanisms are organized and initially explored according to a specific deception taxonomy and the seven abstract dimensions of security previously proposed as a framework for the cyber security of control systems.

99 GENERAL AND MISCELLANEOUS↗

Management of Control System Information SecurityI: Control System Patch Management

The use of information technologies in control systems poses additional potential threats due to the frequent disclosure of software vulnerabilities. The management of information security involves a series of policy-making on the vulnerability discovery, disclosure, patch development and patching. In this paper, we use a system approach to devise a model to understand the interdependencies of these decision processes. In more details, we establish a theoretical framework for making patching decision for control systems, taking into account the requirement of functionability of control systems. We illustrate our results with numerical simulations and show that the optimal operation period of control systems given the currently estimated attack rate is roughly around a half a month.

97 MATHEMATICS AND COMPUTING↗

Supervisory-level control system demand control of an HVAC system

A supervisory-level control system is provided and includes a summation unit receptive of first and second signals, an HVAC system to generate the second signal according to first set-point signals and to a second set-point signal and a supervisory controller. The supervisory controller includes a control unit, a set-point scheduler and a zone level set-point distribution unit. The control unit is receptive of an error signal representing a difference between the first and second signals from the summation unit. The set-point scheduler is receptive of a demand signal generated by the control unit according to the error signal. The set-point scheduler generates a set-point command signal and the second set-point signal according to the demand signal. The zone level set-point distribution unit is configured to generate the first set-point signals in accordance with the set-point command signal.

Adetola, Veronica↗

The dual axis radiographic hydrodynamic test (DARHT) facility personnel safety system (PSS) control system

The mission of the Dual Axis Radiograph Hydrodynamic Test (DARHT) Facility is to conduct experiments on dynamic events of extremely dense materials. The PSS control system is designed specifically to prevent personnel from becoming exposed to radiation and explosive hazards during machine operations and/or the firing site operation. This paper will outline the Radiation Safety System (RSS) and the High Explosive Safety System (HESS) which are computer-controlled sets of positive interlocks, warning devices, and other exclusion mechanisms that together form the PSS.

43/57↗

THE SNS RESONANCE CONTROL COOLING SYSTEM CONTROL VALVE UPGRADE PERFORMANCE

The normal-conducting linac of the Spallation Neutron Source (SNS) uses 10 separate Resonance Control Cooling System (RCCS) water skids to control the resonance of 6 Drift Tube Linac (DTL) and 4 Coupled Cavity Linac (CCL) accelerating structures. The RCCS water skids use 2 control valves; one to regulate the chilled water flow and the other to bypass water to a chilled water heat exchanger. These valves have hydraulic actuators that provide position and feedback to the control system. Frequency oscillations occur using these hydraulic actuators due to their coarse movement and control of the valves. New pneumatic actuator and control positioners have been installed on the DTL3 RCCS water skid to give finer control and regulation of DTL3 cavity temperature. This paper shows a comparison of resonance control performance for the two valve configurations.

43 PARTICLE ACCELERATORS↗

Analysis and improvement of input channel selection algorithm for reliability of control systems in nuclear power plants - 138

In most of non-safety NSSS (Nuclear Steam Supply System) control systems, a process input is composed of two channels for redundancy. In a normal situation, the average of both input channels is used in the control algorithm. If a failed channel is detected, the 'channel selection algorithm' chooses the remaining normal input channel. For a bumpless transition, many implemented control systems include the 'ramping rate' function, which makes it possible for the selected input to slowly approach the new input channel. However, it recently turned out that this function adopted for positive effects may result in unintended consequences for the related control system and the plant in certain cases. Due to a process transient in the plant according to a significant event, any related sensor input signal can rapidly change and finally exceed the pre-defined range for detecting an out-of-range event in a short time. During the process of channel conversion due to a rapid transient in the plant, the processed input from the redundant channels can be distorted if the ramping rate function is not properly implemented. As a result, it can result in a plant shutdown because the control system fails to perform the critical function to mitigate a plant transient. To solve these potential problems, we analyzed the overall causes and derived a proposed algorithm for improving reliability and performance of the control systems. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Examining System-Wide Impacts of Solar PV Control Systems with a Power Hardware-in-the-Loop Platform

High penetration levels of distributed solar PV power generation can lead to adverse power quality impacts such as excessive voltage rise, voltage flicker, and reactive power values that result in unacceptable voltage levels. Advanced inverter control schemes have been proposed that have the potential to mitigate many power quality concerns. However, closed-loop control may lead to unintended behavior in deployed systems as complex interactions can occur between numerous operating devices. In order to enable the study of the performance of advanced control schemes in a detailed distribution system environment, a Hardware-in-the-Loop (HIL) platform has been developed. In the HIL system, GridLAB-D, a distribution system simulation tool, runs in real-time mode at the Pacific Northwest National Laboratory (PNNL) and supplies power system parameters at a point of common coupling to hardware located at the National Renewable Energy Laboratory (NREL). Hardware inverters interact with grid and PV simulators emulating an operational distribution system and power output from the inverters is measured and sent to PNNL to update the real-time distribution system simulation. The platform is described and initial test cases are presented. The platform is used to study the system-wide impacts and the interactions of controls applied to inverters that are integrated into a simulation of the IEEE 8500-node test feeder, with inverters in either constant power factor control or active volt/VAR control. We demonstrate that this HIL platform is well-suited to the study of advanced inverter controls and their impacts on the power quality of a distribution feeder. Additionally, the results from HIL are used to validate GridLAB-D simulations of advanced inverter controls.

14 SOLAR ENERGY↗

The ILC global control system.

The scale and performance parameters of the ILC require new thinking in regards to control system design. This design work has begun quite early in comparison to most accelerator projects, with the goal of uniquely high overall accelerator availability. Among the design challenges are high control system availability, precision timing and rf phase reference distribution, standardizing of interfaces, operability, and maintainability. We present the current state of the design and take a prospective look at ongoing research and development projects.

43 PARTICLE ACCELERATORS↗

Microreactor Automated Control System - Digital Twin Models and Advanced Control Systems Updates

Automation of control systems is expected to be important in the economic and safe operation of microreactors. Therefore, there is a need to develop and demonstrate automated control for microreactors, along with the development of testbeds for this purpose. This report provides updates on the status of a nonnuclear microreactor automated control system (MACS)—a real-time, hardware-in-the-loop testbed for non-nuclear testing of microreactor control system automation. A real-time hardware-in-the-loop testbed incorporates the realistic dynamics of physical systems into control system development and testing. The collaborative effort between Oak Ridge National Laboratory (ORNL) and Idaho National Laboratory (INL) resulted in the development of a prototypic microreactor plant-level digital twin that includes the reactor and a balance of plant system. Advanced control strategies were incorporated to demonstrate testing of control automation solutions. The gRPC communication protocol, which was implemented in the hardware-in-the-loop testbed by INL, was coupled to a digital twin model developed using the TRANsient Simulation Framework of Reconfigurable Models (TRANSFORM) library in Modelica. This digital twin simulation was tested with the ViBRANT hardware for realistic feedback and visual representation of control action in real time. A modular Python client structure was developed to manage functional mock-up unit-based simulation and real-time gRPC communication. Hardware-in-the-loop testing indicated that the modeled reactor—a natural-convection, molten-salt coolant loop configuration—responds well to control of drum positioning for modulation of reactor core power, as well as system-level control and downstream demand changes. Ongoing research is focused on integrating additional control algorithms that utilize data from newly included sensors within the MACS hardware testbed, as well as demonstrating and assessing the performance of the different automated control algorithms on multiple additional operational scenarios.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Resilient Hierarchical Networked Control Systems: Secure Controls for Critical Locations and at Edge

Integration of information and communication technology (ICT) offers new opportunities in improving the management and operation of critical infrastructures such as power systems as it allows connection of different sensors and control components via a communication network, leading to the so-called networked control systems (NCS). However, the use of open and pervasive ICT such as the Internet or wireless communication technologies comes at a price of making NCS vulnerable to cyber intrusions/attacks which may cause physical damage. Here, this chapter presents control algorithms to ensure resilient and safe operation of NCS under unknown cyberattacks. Specifically, a variant of dynamic watermarking strategies is presented by embedding encoding/decoding components of chaotic signals into the NCS for secure control for critical locations where the measurement/control signals are transmitted to/from the control center via a communication network. In addition, resilient cooperative control algorithms are discussed to ensure safe operation at edge of the NCS which consists of a large number of distributed controllable devices. Several numerical examples are provided to illustrate the proposed control strategies.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Electricity Distribution System Resilient Control System Metrics

In order to assess the resilience of a system, a set of measures must be defined. Varying control architecture while considering such a system of metrics targeted at resilience can determine the relative merit of the architectures with respect to the resilience of the system. Traditionally, electricity distribution is concerned with delivery of power from transmission or sub transmission to consumer loads with basic control of tap changing transformers and capacitor banks to regulate delivered voltage and provide reactive power support, respectively. In the near future, modern distribution systems architecture are anticipated to include substantially more controllable assets enabling more complicated control architectures to optimized based on reliability and economics. This paper reports on the definition of resilience metrics developed for modern distribution systems for delivery of electricity. Specifically, the metrics are focused on adaptive capacity related to the scale for which the system is able to resist, respond, recover and restore after disturbances in real or reactive power and time requirements to respond and restore the system to a complete normalcy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Designing an Intrusion Detection for an Adjustable Speed Drive System Controlling a Critical Process

In this article, we address the cyber-security problem of industrial control systems (ICSs) when their sensor measurements may be compromised due to an attacker who has intercepted those measurements via a network. We introduce a general-purpose method “Dynamic Watermarking (DW)” to detect potential cyber-intrusions on speed sensor measurements within industrial control systems, which deploy an adjustable speed drive (ASD) to control a critical process. The DW method is injecting a random private low-amplitude signal with a zero mean Gaussian distribution, “watermark”, into one of the input phase voltages powering the ASD system. The watermark signal propagates through the system including pulse width modulation (PWM) power conversion stage and motor, then ultimately appears in the speed sensor measurements. By deploying two statistical DW tests with two proper thresholds, the system can detect potential cyber-intrusions or unobservable cyber-attacks such as replay attacks and false data injection attacks (FDIA). The DW method tested on a laboratory-scale ASD system experimentally to protect the system against cyber-intrusions. This system, powered by a commercial PWM drive operating at 208 V, 3-phase, and 3.7 kW, served as our experimental platform.

42 ENGINEERING↗

Notional Examples and Benchmark Aspects of a Resilient Control System

Digital control system technology has pervaded most industries, leading to improvements in the efficiency and reliability of the associated operations. However, the ease of distributing and connecting related control systems for the purposes of increasing performance has resulted in interdependencies that can lead to unexpected conditions. Even with less complex designs, operators and engineers alike are often left with competing goals that are difficult to resolve. A fundamental reason for this dichotomy is that responsibilities lie with different disciplines, and operations are hosted on separate control systems. In addition, with the rising awareness of cyber security and diverse human interactions with control systems, an understanding of human actions from a malicious and benevolent standpoint is necessary. Resilience considers the multiple facets of requirements that drive the performance of control systems in a holistic fashion, whether they are security or stability, stability or efficiency, human interactions or complex interdependencies. As will be shown by example, current research philosophies lack the depth or the focus on the control system application to satisfy these requirements, such as graceful degradation of hierarchical control while under cyber attack. A resilient control system promises to purposefully consider these diverse requirements, developing an adaptive capacity to complex events that can lead to failure of traditional control system designs.

47 OTHER INSTRUMENTATION↗

Notional Examples and Benchmark Aspects Of a Resilient Control System

Digital control system technology has pervaded most industries, leading to improvements in the efficiency and reliability of the associated operations. However, the ease of distributing and connecting related control systems for the purposes of increasing performance has resulted in interdependencies that can lead to unexpected conditions. Even with less complex designs, operators and engineers alike are often left with competing goals that are difficult to resolve. A fundamental reason for this dichotomy is that responsibilities lie with different disciplines, and operations are hosted on separate control systems. In addition, with the rising awareness of cyber security and diverse human interactions with control systems, an understanding of human actions from a malicious and benevolent standpoint is necessary. Resilience considers the multiple facets of requirements that drive the performance of control systems in a holistic fashion, whether they are security or stability, stability or efficiency, human interactions or complex interdependencies. As will be shown by example, current research philosophies lack the depth or the focus on the control system application to satisfy these requirements, such as graceful degradation of hierarchical control while under cyber attack. A resilient control system promises to purposefully consider these diverse requirements, developing an adaptive capacity to complex events that can lead to failure of traditional control system designs.

47 OTHER INSTRUMENTATION↗

Application of control system studio for the NOvA detector control system

In the NO A experiment, the Detector Controls System (DCS) provides a method for controlling and monitoring important detector hardware and environmental parameters. It is essential for operating the detector and is required to have access to roughly 370,000 independent programmable channels via more than 11,600 physical devices. In this paper, we demonstrate an application of Control System Studio (CSS), developed by Oak Ridge National Laboratory, for the NO A experiment. The application of CSS for the DCS of the NO A experiment has been divided into three phases: (1) user requirements and concept prototype on a test-stand, (2) small scale deployment at the prototype Near Detector on the Surface, and (3) a larger scale deployment at the Far Detector. We also give an outline of the CSS integration with the NO A online software and the alarm handling logic for the Front-End electronics.

Lukhanin, Gennadiy↗