Search NASA⌕ Search

SEARCH · Search NASA

Results for “System testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Nodal Capacity Expansion Modeling with ReEDS: A Case Study of the RTS-GMLC Test System

Test systems play an important role in power systems analysis and are used extensively for a wide range of purposes like reliability analysis, production cost modeling, studying the impacts of load shifting, and many more. These test systems have continued to evolve over the years to keep pace with changing system compositions due to technology and policy changes. In this work, we apply the Regional Energy Deployment System (ReEDS) model, a large-scale capacity expansion model (CEM), on the nodal RTS-GMLC system to perform capacity expansion of the bus-level test system. This work both demonstrates that a large-scale CEM can successfully be applied to nodal systems, and that the CEM can allow a test system to be evolved to meet desired criteria. The process allowed the coupling of CEM data not available in the test system (such as capital costs) with test system data to provide plausible system evolutions in line with scenario specifications.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Automated Testing System

The Automated Testing System (ATS) is an open-source, Python-based tool for automating the running of tests of an application across a broad range of high performance computers.

Dempsey, StephanieM.↗

An ERCOT test system for market design studies

An open source test system is developed that permits the dynamic modeling of centrally-managed wholesale power markets operating over highvoltage transmission grids. In default mode, the test system models basic operations in the Electric Reliability Council of Texas (ERCOT): namely, centrally-managed day-ahead and real-time markets operating over successive days, with congestion handled by locational marginal pricing. These basic operational features characterize all seven U.S. energy regions organized as centrally-managed wholesale power markets. Modeled participants include dispatchable generators, load-serving entities, and non-dispatchable generation such as unrmed wind and solar power. Users can congure a broad variety of parameters to study basic market and grid features under alternative system conditions. Users can also easily extend the test system's Java/Python software classes to study modied or newly envisioned market and grid features. Finally, the test system is integrated with a high-level simulation framework that permits it to function as a software component within larger systems, such as multi-country systems or integrated transmission and distribution systems. Finally, detailed test cases with 8-bus and 200-bus transmission grids are reported to illustrate these test system capabilities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Introducing the 9500 Node Distribution Test System to Support Advanced Power Applications: An Operations-Focused Approach

The 9500 Node Test System is a representative section of distribution power system model developed as a part of the GridAPPS-D™ project, an effort funded by DOE as a part of the Grid Modernization Lab Consortium (GMLC) program. The test system was developed to fulfill a growing need to represent the rapidly evolving state of electric distribution systems by combining elements of legacy infrastructure systems, modern feeder topologies, and an anticipated future with smart grid technologies. It also provides a network model capable of supporting the simulation of operational scenarios such as the ones in a utility distribution control center. This test system allows the evaluation of the performance of advanced power applications in real-time, such as one that simulates the operations of an Advanced Distribution Management Systems (ADMS), Distributed Energy Resource Management Systems (DERMS), etc. in a Distribution control center. This model is an extension of the widely used IEEE 8500 Node Test Feeder and is currently being validated to become an IEEE test case to help increase adoption and widespread usage among both academia and industry. It is a full-size model representative of a section of a utility’s distribution system with multiple feeders fed from different substations. The model includes multiple distribution circuits, a sub-transmission system, multiple substations, behind the meter customer rooftop photovoltaics (PV), and multiple utility-scale distributed energy resources. To enable accurate simulations of operational scenarios, the 9500 Node Test System is designed to support procedure-based operations, with the ability to realistically demonstrate switching operations, feeder reconfiguration, adjustment of volt-var control equipment, dispatch of distributed generation, and response to planned and unplanned outages. The 9500 Node Test System includes three radial distribution feeders with 12.3 MVA of average load, consisting of both medium voltage and low voltage equipment each supplied by a different distribution substation. The three distribution feeders are connected to each other through Normally-Open switches which can be closed when needed to simulate restoration scenarios due to a fault. One feeder represents today’s grid with low penetration of customer-side renewables. The second represents a potential future grid with microgrids and 100% renewable penetration. The third has no customer generation resources, a district steam plant, and a utility-scale solar farm. The three diverse circuits were created to allow the simulation of both today’s situation as well as potential future scenarios. All three feeders have customers connected by low-voltage secondary triplex lines. This test system meets all requirements outlined in the report for creating a simulation environment that would enable discussion between key technical stakeholders as well as having the potential to accelerate operational application development and their subsequent testing and integration. The new model is a possible representation of what we believe the distribution grid may look like in the future: a high penetration of renewables, reconfigurable radial and mesh topology, numerous DERs, islanded microgrids, and significantly increased data and measurement density. The system supports both the solution of existing and newer algorithms but also enables the evaluation of applications in a realistic operational environment defined by task oriented procedural steps that represent the interaction between the control center operator and field personnel.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A self-certifying FPGA based pixel readout chip test system for CMS ETL upgrade

A flexible self-certifying pixel readout test system for testing the Endcap Timing Read-Out Chip (ETROC) has been developed for the CMS MIP Timing Detector (MTD), part of the upgrade for the HL-LHC. The system includes an FPGA-based (Xilinx KC705) test system that can take data from an emulator or up to four ETROC boards in telescope mode. A python based DAQ system simplifies configuration, calibration, and testing of the chips. The system provides an efficient & reliable solution for testing ETROC (ETROC2 since April 2023 with 16x16 pixels, full-size, full functionality prototype) and can be extended to other readout chips with similar architecture (AIDA integration is currently being explored).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cataloging Legacy Data from the Tritium Systems Test Assembly Program

The Tritium Systems Test Assembly (TSTA) at Los Alamos National Laboratory, operational from 1984 to 2001, was critical in advancing fusion fuel cycle technologies, including tritium storage, gas separation, and pumping. TSTA’s contributions, particularly in safe tritium operations, have influenced subsequent fusion projects. This paper discusses the ongoing effort to digitize and catalog TSTA’s historical data to create a searchable resource for the fusion research community. While the long-term objective is to develop a relational database for structured data management, the project remains in the early phase, with current efforts focused on scanning and indexing physical documents. Initial plans for database implementations are also presented, outlining key considerations for structure, query indexing, and standardization. As digitization progresses, future discussions will refine these implantation details to ensure an efficient and comprehensive system. This initiative aims to preserve critical legacy data, enhance the design of tritium system facilities, and support the next generation of fusion energy research.

42 ENGINEERING↗

Using Hardware-In-The-Loop Methodology to Develop Test Systems

Hardware in the Loop (HIL) testing methodologies have become widespread in industry. Typically, they focus on developing control algorithms for systems such as autonomous vehicles or aircraft. An oft overlooked aspect of product development is the design and fabrication of a test system for validating that the product meets requirements. Abstractly, a test system differs little from a control system—testers provide signals to the unit, monitor feedback, and base decisions on the results. While the time scales may differ, the functionalities are conceptually similar. Viewed in this light, it becomes natural to extend HIL approaches to tester development. By replacing a physical unit with a proxy model deployed to a real-time or pseudo real-time target, test systems can be developed in parallel with the design and fabrication of a first production unit. This saves considerable time in the life cycle from conceptual design to realized product. This manuscript demonstrates the process flow using a capacitive discharge unit as an exemplar.

42 ENGINEERING↗

Posiva's Onkalo{sup R} FST (Full-Scale In Situ System Test) - 20051

The FST - Full-scale In Situ System Test - is a unique full-scale demonstration of disposal system in crystalline host rock. The FST was constructed in ONKALO{sup R} demonstration area at the disposal depth of 420 metres, in Posiva's actual final disposal facility at Olkiluoto, Finland. The demonstration has included design, manufacture, installation and comprehensive instrumentation for monitoring the evolution of the disposal system and its components. The demonstration tunnel and experimental deposition holes were excavated in 2010 in ONKALO to address that they can be excavated to meet the requirements set for them. Two experimental deposition holes, bored in the floor of the tunnel, host each a canister surrounded by bentonite clay buffer rings/segments in the holes. Inside the canisters are heating elements to simulate decay heat emitted by spent fuel. The tunnel part used for the test is about 50 m long and it was filled with bentonite clay backfill after the installation of the canisters and buffer components. The tunnel is closed with a steel-reinforced concrete plug. The test is equipped with 500 sensors to monitor early evolution of the system. To forecast the evolution of the system, a mathematical model has been created. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of the KRUSTY Nuclear System Test

The Kilowatt Reactor Using Stirling TechnologY (KRUSTY) was a prototypic nuclear-powered test of a 5-kW(thermal) Kilopower space reactor. This paper presents results from the KRUSTY nuclear system test, which operated the power system at various temperatures and power levels for 28 consecutive hours. The testing showed that the system operated as expected and that the reactor is highly tolerant of possible failure conditions and transients. The key feature demonstrated was the ability of the reactor to load-follow the demand of the power conversion system. The thermal power of the test ranged from 1.5 to 5.0 kW(thermal), with a fuel temperature up to 880°C. Each 80-W(electric)–rated Stirling converter produced ~90 W(electric) at a component efficiency of ~35% and an overall system efficiency of ~25%.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of a test system for data links of the ATLAS Inner Tracker (ITk) upgrade silicon pixel detector

This contribution introduces a novel test system developed to evaluate the signal transmission quality in high-speed data links for the 2026 Inner Tracker (ITk) upgrade of the ATLAS experiment. Using an FPGA-based data acquisition (DAQ) framework, the setup can run simultaneous Bit Error Rate (BER) tests for up to 64 channels and generate virtual eye diagrams, for qualifying the ∼26k electrical links at the ATLAS ITk data rate of 1.28 Gb/s. The paper includes results from system calibration, yielding its contribution to the measured losses, and preliminary results from tests of prototype and pre-production assemblies of on-detector links of the three ATLAS ITk Pixel subsystems.

47 OTHER INSTRUMENTATION↗

A Robotics Enabled Eddy Current Testing System for Autonomous Inspection of Heat Exchanger Tubes

The objective of the project is to develop a robotics enabled eddy current testing system (REECTS) in automatic probe deployment, inspection, and data acquisition and analysis. The main functions of the REECTS are to: 1) identify geometry and locations of heat exchange tubes with assistance of an imaging recognition system; 2) precisely control the position and motion speed of ECT probes by an adaptive control system; 3) facilitate data analysis and real-time decision making for autonomous inspection assisted by machine learning algorithms.

20 FOSSIL-FUELED POWER PLANTS↗

Developing a PSCAD Model of the Reduced 240-Bus WECC Test System: Preprint

Fast-acting controls of inverter-based resources (IBR) introduce unprecedented dynamics to bulk power systems and island power grids, especially the high-frequency dynamics ranging from $>5$ Hz to hundreds of Hz. These oscillatory stability problems cannot be captured by the phasor domain simulations, e.g., in PSS/E, Powerworld and TSAT, due to insufficient modeling. Instead, they should be studied by electromagnetic transient (EMT) simulations by using proper EMT dynamic models. This paper develops and validates the PSCAD model of the reduced 240-bus Western Electricity Coordinating Council (WECC) test system. The PSCAD model will be released to the public, which can be used by both academia and power industry practitioners for studying the fast dynamic problems without any Critical Energy/Electric Infrastructure Information (CEII).

240-bus WECC test system↗

Filter Test System for Nuclear Container Filters

The purpose of this procedure is to measure the collection efficiency of the filters that are integrated into the lids of containers for nuclear material at Los Alamos National Laboratory (LANL). As an application of this procedure, a filter test report certificate can be created to document the measurement process. This procedure is intended to describe the TA-55, PF-4 (room 6A) operation of a Filter Test System (FTS) for Hagan and SAVY storage containers.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Complete the Design, Cost Estimate, Assembly Plan, and Operating Instructions for a Bench-Scale Packed-Bed Tubular Methanol Catalyst Testing System

This report details the design of a test stand that converts carbon dioxide and hydrogen into methanol via a two-step process. The first step is a reverse water-gas shift reaction, carried out at 600°C and 25 bar to reduce carbon dioxide to carbon monoxide, and the second is a synthesis reaction that forms methanol at 260°C and 75 bar. The purpose of the system is to test catalysts for each of these steps. The test stand produces approximately 1.5 gallons of crude methanol (methanol mixed with water) per day, and recycles unreacted syngas for increased efficiency. At peak recycle, the stand is expected to consume 0.29 cylinders per day of carbon dioxide and 1.43 cylinders per day of hydrogen. It is planned to be built next to the Blue Star electrolysis unit in the Energy Systems Laboratory (ESL) and includes future plans of acquiring hydrogen from that stand rather than gas cylinders. At this phase of research, three key documents have been produced, as summarized in Table 1. These documents are primarily intended to describe the system and its operation, demonstrate that selected components are appropriate for the intended application, identify potential hazards, safeguards, and mitigation strategies, and ensure that the system is designed to appropriate standards. The body of the report and its appendices provide a narrative of the work completed in FY25. The parts required to build the test stand will be procured and assembled in FY26. Testing will be conducted in the final quarter.

10 - SYNTHETIC FUELS↗