Search NASASearch

SEARCH · Search NASA

Results for “TACTILE DISCRIMINATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Tactile discrimination and representations of texture, shape, and softness

We present here some of the salient results on the tactual discriminabilities of human subjects obtained through psychophysical experiments, and the associated peripheral neural codes obtained through electrophysiological recordings from monkey single nerve fibers. Humans can detect the presence of a 2 micron high single dot on a smooth glass plate stroked on the skin, based on the responses of Meissner type rapidly adapting fibers (RAs). They can also detect a 0.06 micron high grating on the plate, owing to the response of Pacinian corpuscle fibers. Among all the possible representations of the shapes of objects, the surface curvature distribution seems to be the most relevant for tactile sensing. Slowly adapting fibers respond to both the change and rate of change of curvature of the skin surface at the most sensitive spot in their receptive fields, whereas RAs respond only to the rate of change of curvature. Human discriminability of compliance of objects depends on whether the object has a deformable or rigid surface. When the surface is deformable, the spatial pressure distribution within the contact region is dependent on object compliance, and hence information from cutaneous mechanoreceptors is sufficient for discrimination of subtle differences in compliance. When the surface is rigid, kinesthetic information is necessary for discrimination, and the discriminability is much poorer than that for objects with deformable surfaces.

Srinivasan, M. A.

Cognitive information processing

Cognitive information processing studies of digital and PCM picture and signal transmission systems, and methods for tactile display reading and magnetic tape to Braille conversion

DIGITAL TRANSDUCER

Investigation of the effects of extravehicular activity (EVA) gloves on performance

The objective was to assess the effects of extravehicular activity (EVA) gloves at different pressures on human hand capabilities. A factorial experiment was performed in which three types of EVA gloves were tested at five pressure differentials. The independent variables tested in this experiment were gender, glove type, pressure differential, and glove make. Six subjects participated in an experiment where a number of dexterity measures, namely time to tie a rope, and the time to assemble a nut and bolt were recorded. Tactility was measured through a two point discrimination test. The results indicate that with EVA gloves strength is reduced by nearly 50 percent, there is a considerable reduction in dexterity, performance decrements increase with increasing pressure differential, and some interesting gender glove interactions were observed, some of which may have been due to the extent (or lack of) fit of the glove to the hand. The implications for the designer are discussed.

Bishu, Ram R.

Flexible tactile sensing arrays for robotics: Architectural robustness and yield considerations

No tactile sensor array developed to date fills all, nor even most, of the requirements of: (1) many sensor elements to minimize tactile imaging time, (2) close spacing of small sensing elements for fine spatial discrimination, (3) ability to be molded to a convex fingertip surface for taction on concave surfaces, (4) ability to sense both force and temperature in order to fully mimic biological touch, (5) tolerance to overscale forces without damage, and (6) graceful failure in use, i.e., functional survival of most of the array when part of it is damaged, well. Several investigators have recently developed tactile sensing arrays suitable for imaging shapes on hard flat surfaces, but not well suited for taction on curved surfaces. Others have developed single tactile sensors suitable for incorporation into arrays, which will probably prove uneconomical when large numbers of sensors are needed. Still others have developed flexible capacitive arrays suitable for use on curved surfaces but incapable of obtaining temperature or proximity data. A technology is being developed herein suitable to the achievement of all of the above goals, and to incrementally demonstrate useful steps toward those goals.

Barth, Phillip W.

Vibratory tactile display for textures

We have developed a tactile display that produces vibratory stimulus to a fingertip in contact with a vibrating tactor matrix. The display depicts tactile surface textures while the user is exploring a virtual object surface. A piezoelectric actuator drives the individual tactor in accordance with both the finger movement and the surface texture being traced. Spatiotemporal display control schemes were examined for presenting the fundamental surface texture elements. The temporal duration of vibratory stimulus was experimentally optimized to simulate the adaptation process of cutaneous sensation. The selected duration time for presenting a single line edge agreed with the time threshold of tactile sensation. Then spatial stimulus disposition schemes were discussed for representation of other edge shapes. As an alternative means not relying on amplitude control, a method of augmented duration at the edge was investigated. Spatial resolution of the display was measured for the lines presented both in perpendicular and parallel to a finger axis. Discrimination of texture density was also measured on random dot textures.

Ikei, Yasushi