Search NASA⌕ Search

SEARCH · Search NASA

Results for “TARGET CHAMBERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Detection and elimination of reflections in beam-foil target chambers

Description of techniques for detecting and reducing to negligible values beam-radiation reflection and scattering in high vacuum target chambers used in beam foil experiments. It is suggested that all target chambers be checked in the manner described in order to discover and reduce intensity variations that may not be obvious on the usual beam-foil decay curves.

Bickel, W. S.↗

The MUSE Target Chamber Post Veto

The Muon Scattering Experiment (MUSE) was developed to address the proton radius puzzle through simultaneous electron–proton and muon-proton scattering using the Paul Scherrer Institute’s πM1 secondary beamline. MUSE uses a large-solid-angle, non-magnetic spectrometer to detect beam particles scattering from a liquid hydrogen cell contained within a vacuum chamber. Due to the large scattering windows, the structural integrity of the chamber is supported by posts located at small scattering angles. While out of the acceptance, particles in the tails of the beam distribution can strike these posts, causing a significant trigger background. We describe the design and performance of the Target Chamber Post Veto (TCPV) detector installed inside the vacuum chamber to remove these background events at the trigger level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chamber Interior Viewing System (CIVS 2.0)

The NIF facility is used to conduct fusion and high-density scientific research. The experiments are conducted inside of a 10-meter diameter vacuum chamber called the “Target Chamber”. The target chamber is covered in ports to permit adding equipment to the exterior. Some of this equipment extends into the target chamber such as the target positioners and diagnostics. Other equipment sits on the surface and looks inward, such as the CIVS system. CIVS stands for Chamber Interior Viewing System. The CIVS system provides simple black and white digital images of the interior of the target chamber in real time. These images are used for positioner alignment, trouble shooting and observing for positioner collision. The views through these cameras need to be clear enough for the operators to safely conduct these tasks. One of the products of the experiments conducted in the target chamber are neutrons. These neutrons expand outward from the center of the target chamber with great energy. If the neutrons hit the sensor chip on a digital camera they will “kill” the sensor pixel where they contact, and the result will be a permanently bright white pixel on the image. Over time these “dead” pixels will build up and make the camera less and less usable providing a “staticky” image. The current solution of replacing the cameras when they become damaged is unsustainable due to both the cameras being out of production and the increased rate of camera failure based upon the increased number and energy of neutrons being generated. Current supplies of the correct camera type are dwindling with no source of replacement and the projected rate of replacement is unsustainable. Without a redesign, the function provided by the current CIVS system will be lost.

42 ENGINEERING↗

Selective Functionalization of Carbon Nanotubes: Part II

An alternative method of low-temperature plasma functionalization of carbon nanotubes provides for the simultaneous attachment of molecular groups of multiple (typically two or three) different species or different mixtures of species to carbon nanotubes at different locations within the same apparatus. This method is based on similar principles, and involves the use of mostly the same basic apparatus, as those of the methods described in "Low-Temperature Plasma Functionalization of Carbon Nanotubes" (ARC-14661-1), NASA Tech Briefs, Vol. 28, No. 5 (May 2004), page 45. The figure schematically depicts the basic apparatus used in the aforementioned method, with emphasis on features that distinguish the present alternative method from the other. In this method, one exploits the fact that the composition of the deposition plasma changes as the plasma flows from its source in the precursor chamber toward the nanotubes in the target chamber. As a result, carbon nanotubes mounted in the target chamber at different flow distances (d1, d2, d3 . . .) from the precursor chamber become functionalized with different species or different mixtures of species. In one series of experiments to demonstrate this method, N2 was used as the precursor gas. After the functionalization process, the carbon nanotubes from three different positions in the target chamber were examined by Fourier-transform infrared spectroscopy to identify the molecular groups that had become attached. On carbon nanotubes from d1 = 1 cm, the attached molecular groups were found to be predominantly C-N and C=N. On carbon nanotubes from d2 = 2.5 cm, the attached molecular groups were found to be predominantly C-(NH)2 and/or C=NH2. (The H2 was believed to originate as residual hydrogen present in the nanotubes.) On carbon nanotubes from d3 = 7 cm no functionalization could be detected - perhaps, it was conjectured, because this distance is downstream of the plasma source, all of the free ions and free radicals of the plasma had recombined into molecules.

Meyyappan, Meyya↗

Assessment of personal airborne exposures and surface contamination from x-ray vaporization of beryllium targets at the National Ignition Facility

Here, this article presents air and surface sampling data collected over the first two years since beryllium was introduced as a target material at the National Ignition Facility. Over this time, 101 experiments with beryllium-containing targets were executed. The data provides an assessment of current conditions in the facility and a baseline for future impacts as new, reduced regulatory limits for beryllium are being proposed by both the Occupational Safety and Health Administration and Department of Energy. This study also investigates how beryllium deposits onto exposed surfaces as a result of x-ray vaporization and the effectiveness of simple decontamination measures in reducing the amount of removable beryllium from a surface. Based on 1,961 surface wipe samples collected from entrant components (equipment directly exposed to target debris) and their surrounding work areas during routine reconfiguration activities, only one result was above the beryllium release limit of 0.2 µg/100 cm 2 and 27 results were above the analytical reporting limit of 0.01 µg/100 cm 2 , for a beryllium detection rate of 1.4%. Surface wipe samples collected from the internal walls of the NIF target chamber, however, showed higher levels of beryllium, with beryllium detected on 73% and 87% of the samples during the first and second target chamber entries (performed annually), respectively, with 23% of the samples above the beryllium release limit during the second target chamber entry. The analysis of a target chamber wall panel exposed during the first 30 beryllium-containing experiments (cumulatively) indicated that 87% of the beryllium contamination remains fixed onto the surface after wet wiping the surface and 92% of the non-fixed contamination was removed by decontaminating the surface using a dry wipe followed by a wet wipe. Personal airborne exposures assessed during access to entrant components and during target chamber entry indicated that airborne beryllium was not present in workers' breathing zones. Finally, all the data thus far have shown that beryllium has been effectively managed to prevent exposures to workers during routine and non-routine work.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Titanium Hydroxide - a Volatile Species at High Temperature

An alternative method of low-temperature plasma functionalization of carbon nanotubes provides for the simultaneous attachment of molecular groups of multiple (typically two or three) different species or different mixtures of species to carbon nanotubes at different locations within the same apparatus. This method is based on similar principles, and involves the use of mostly the same basic apparatus, as those of the methods described in "Low-Temperature Plasma Functionalization of Carbon Nanotubes" (ARC-14661-1), NASA Tech Briefs, Vol. 28, No. 5 (May 2004), page 45. The figure schematically depicts the basic apparatus used in the aforementioned method, with emphasis on features that distinguish the present alternative method from the other. In this method, one exploits the fact that the composition of the deposition plasma changes as the plasma flows from its source in the precursor chamber toward the nanotubes in the target chamber. As a result, carbon nanotubes mounted in the target chamber at different flow distances (d1, d2, d3 . . .) from the precursor chamber become functionalized with different species or different mixtures of species.

Nguyen, QuynhGiao N.↗

Fielding the LANL Gas Cherenkov Detector (GCD-3) at the National Ignition Facility: The engineering challenges of designing, analyzing, fabricating, testing, and commissioning the next-generation GCD detector and WellDIM3.9m insertion manipulator for use at NIF

We report that fielding the LANL third-generation Gas Cherenkov Detector (GCD-3) at the National Ignition Facility (NIF) revealed an array of complex engineering challenges. Fielding the GCD-3 Detector in a 3.9 meter re-entrant Well on the NIF Target Chamber required the development of a specialized detector deployment system named the WellDIM3.9m Diagnostic Manipulator (WellDIM). The most stringent design requirement entailed a no-load/no-contact condition with the Well, which dictated that all seismic loads be transferred to the Target Chamber port flange. The WellDIM transports the GCD-3 into the Well at a distance of 3.9m from Target Chamber Center. Finally, the GCD-3 Detector, outfitted with additional shielding to mitigate higher NIF backgrounds, will serve as a prototype for the future, heavily shielded “Super-GCD”.

42 ENGINEERING↗

NIF-TAS Miniature Calibration Station

“On Aug. 8, 2021, an experiment at Lawrence Livermore National Laboratory’s (LLNL’s) National Ignition Facility (NIF) made a significant step toward ignition, achieving a yield of more than 1.3 megajoules (MJ). This advancement puts researchers at the threshold of fusion ignition, an important goal of the NIF, and opens access to a new experimental regime.” NIF experiments are conducted by symmetrically focusing 192 laser beams from NIF (three football fields in length) into the Target Chamber (10-meter diameter sphere) onto a target 2mm in size. The reaction produces a hot spot the diameter of a human hair, generating more than 10 quadrillion watts of fusion power for 100 trillionths of a second. These high pressures and temperatures created by the NIF have only been seen on the surface of the sun. To achieve fusion ignition, the target must be compressed to high pressures and temperatures, which requires symmetric compression. This symmetry requires precise alignment of the laser beams to the target. To achieve this precise symmetry a Target Alignment System (TAS) was developed to aid in aligning the beams to the target. The accomplishment on Aug 8 th could not have been accomplished without the TAS. TAS has proven to be a critical contributor to the success of NIF experiments. Each TAS is composed of several Charge Couple Device (CCD) sensors and various support electronics. Unfortunately, these CCDs are no longer available in industry as they have become outdated and obsolete. There is a limited amount of spare CCDs in the facility. As the NIF continues to increase its energy output of its fusion ignition shot experiments (heigh yield shots), more neutrons are being emitted from the Target Chamber. These neutrons are very damaging to the TAS electronics and its sensors, thus degrading and reducing its life expectancy dramatically. The increase of neutrons exceeds the damage threshold of the CCDs. This would increase the demand for more frequent TAS refurbishments and calibrations. The increase in resources to perform these refurbishments and calibrations would not be sustainable. In efforts to prolong the life of each TAS system it was determined that the TAS should be removed for every High Yield Shot and then reinstalled. The high precision fully calibrated TAS can easily be knocked out of alignment during these installs and reinstall exchanges and being transported in and out of the NIF. The Miniature Calibration Station System was developed to verify that the critical calibration parameters have been preserved during every TAS exchange. The Miniature Calibration Station System (Mini-Cal) would need to be a scaled down (in size and scope), portable version of the offline TAS calibration station to verify the critical TAS parameters are still within tolerances.

42 ENGINEERING↗

Tunable UV upgrade on OMEGA EP

The OMEGA EP laser has been upgraded to provide a UV wavelength-tunable beam to support the study of wavelength detuning for the mitigation of cross-beam energy transfer in direct-drive inertial confinement fusion. The beamline delivers up to 0.5 TW in pulses up to 1-ns duration (0.1 TW up to 2.5 ns), to either the OMEGA or OMEGA EP target chambers with wavelength tunable from 350.2 to 353.4 nm. The upgrade leverages the existing optical parametric amplification (OPA) system in the short-pulse front end of OMEGA EP Beamline 1 for amplification of a new tunable, narrowband fiber front end over a broad spectral range. The tunable OPA output is spatially shaped to form a round OMEGA-like beam, which is amplified in the OMEGA EP beamline, then frequency tripled and characterized using the existing OMEGA EP long-pulse infrastructure. A new 3ω beam-transport system intercepts the tunable UV beam near the OMEGA EP target chamber and image relays it to the P9 port of the OMEGA target chamber for joint shots with the OMEGA 60-beam laser. Commissioning of the tunable UV capability has been completed, and four experimental campaigns have been supported with the tunable beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Active Measurement of Plasma Parameters in Over-Dense MFE Reactor Plasma Using High Frequency Beat-Wave Resonantly Generated Thermal Bernstein Waves

UC Davis was funded to explore the combination of beat-wave excitation and laser scattering to make completely non-invasive determination of local plasma conditions. This involves the use of two high frequency mm-wave sources of differing frequencies (the pump waves) to excite plasma waves at the difference of the frequencies, which is known as the beat frequency. The difference frequency or the frequency of the beat wave is chosen so that we produce plasma waves whose fluctuating electron density is a sensitive function of plasma parameters at the location where the source waves overlap. This fluctuation can be detected from outside the plasma, by measuring the deflection of a probe beam directed at the overlap region between the two pump waves (i.e., collective scattering). This work is an extension of mm-wave frequencies of a 10 GHz beat-wave experiment conducted on the DDT toroidal device (see Fig. 1) in a magnetized plasma where the excited Langmuir wave is replaced by the magnetized upper hybrid wave. Here, two high power (> 1 kW) ~94 GHz pump sources will be employed to match the upper hybrid resonance. The primary envisioned experiment is to drive the electron Bernstein wave (EBW) in the interior of a magnetized plasma. The EBW is a hot-plasma electrostatic wave, which cannot propagate in vacuum. Roots of the EBW dispersion relation occur at frequencies slightly higher than harmonics of the electron cyclotron frequency. Use of the EBW has particular advantages for measuring plasma magnetic field in plasmas with relatively high density and low magnetic field, as is the case in spherical tokamaks. This is the “over dense” condition of future efficient high beta magnetic confinement fusion reactors such as the spherical tokamak (STs). The overarching goal of the proposed project is to demonstrate beat wave EBW excitation in low density and temperature parameters that are directly scalable to over-dense spherical tokamaks such as NSTX or MAST, where measurement of magnetic field by electron cyclotron emission (ECE) is experimentally complex, and requires models of plasma profiles in order to interpret results. In such experiments, availability of point measurements of magnetic field strength provided by a beat-wave diagnostic would serve as a powerful independent check on the ECE results, serving to validate the assumed profiles and wave-propagation models used. The first step was to assemble/modify the target chamber in which the beat-wave plasma experiments will take place. Here, the target chamber of the CTIX compact-toroid (spheromak) injector was chosen. At the time that the proposal was submitted, the aim was to conduct the experiments in the CTIX experimental facilities located at the Livermore campus of UC Davis using microwave/mm-wave equipment brought from the main campus., However, by the time DoE funds for this project were awarded, the CTIX experimental facilities located at the Livermore campus of UC Davis were in the process of being shut down due to the closure of the Livermore campus by Lawrence Livermore National Laboratory (LLNL). Consequently, the equipment needed for this project was crated up and shipped from Livermore to Davis as part of the laboratory shutdown after space on campus was secured and College of Engineering approval secured. Once it arrived in Davis on December 20, 2018, work on the project began in earnest with the initial efforts directed toward developing a new plasma target source. Because of the shutdown of the CTIX facility, the scope of the project thus had to be reduced due to the abbreviated amount of time allocated to the project once the shutdown/move had been completed. Chamber modifications have been completed, including the fabrication and installation of a 38 GHz interferometer, as described in Sec. 3. The thermionic plasma source has been tested and characterized. The magnetic field required for the EBW experiments will be generated by permanent magnets mounted on plates positioned above and below the chamber. Magnetic simulations have been performed, and show that a 3-ring magnet arrangement on each plate, with a plate separation of 50 cm, is required to achieve the ~100 G uniform magnetic field in the interaction region that we feel is necessary to ensure good EBW coupling. We proved unable to successfully revive either of Prof. Luhmann’s two high power (≥20 kW) 94 GHz millimeter-wave sources after their extended time in storage and decided to postpone further efforts and concentrate on slightly lower power sources. Consequently, we were successful in reviving a ~2 kW extended klystron amplifier (EIK), which together with a ~2 kW extended interaction oscillator (EIO) will provide the two pump sources required for the project. Safe operation of the EIO requires extensive modifications to one of Prof. Luhmann’s pulse modulators - these modulator modifications are ongoing, which has unfortunately delayed the planned beat-wave experiments. Details of this work are provided in Sec. 3. Even though project funding has now ended, we still plan to proceed to complete the EIO pulse modulator modifications, install the two ~94 GHz pump wave sources on the target chamber, and conduct unmagnetized tests of the beat-wave concept which involve coupling to unmagnetized electron plasma waves rather than magnetized EBWs. Should these experiments prove successful, we plan to submit a follow-up proposal for additional funding which would allow us to undertake the magnetized EBW experiments.

42 ENGINEERING↗

Report on High-Contrast Advanced Radiographic Capability Review

The Advanced Radiographic Capability (ARC) project at the National Ignition Facility (NIF) is designed to generate picosecond duration, kilo-Joule laser pulses to produce xrays for backlighting NIF experiments. The baseline concept (Figure 1), utilizing a single NIF beam quad, diverts the beamline(s) using insertable pick-off mirrors to a compressor chamber in the target bay and focuses it to target chamber center. When fully implemented, ARC will use a quad of NIF beamlines to deliver eight Petawatt-class, high-intensity pulses in a split aperture configuration (2 short pulse apertures per NIF beamline). These short pulses will be adjustable in energy (up to 13.2 kJ in full implementation), delays (0-80 ns) and pulse durations (1-50 ps) and can be individually pointed to targets. ARC will enable dynamic, multi-frame x-ray imaging (radiography) on NIF for applications in laser driven fusion and other high-energy density science missions. The near-term missions in support of the SSP program are described below.

42 ENGINEERING↗

Simulation of the Post-Shot Radiation Environment in the National Ignition Facility

The National Ignition Facility at Lawrence Livermore National Laboratory is the world’s biggest and most energetic laser system for inertial confinement fusion. The NIF is designed to perform shots with varying fusion yield (up to 20 MJ or 7.1 × 10 18 neutrons per shot). A great number of diagnostic instruments are present inside the target chamber (TC) and target bay (TB) during shots. The gamma dose rates due to neutron activation are estimated at various decay times following the high-yield (20-MJ) shots. Several components, like the snout assemblies of the diagnostic instrument manipulators and target positioners are inserted inside the TC, close to the target during the shot. These components represent major sources of gamma decay after retraction outside the TC. Five days after a 20-MJ shot, dose rates near the highly activated (retracted) parts are on the order of 1 mSv/h and dose rates within the TB outside the TC but at distance from the retracted components drop to about 50 to 70 μSv/h. The dose is dominated by decay of 24 Na (T 1/2 = 14.95 h) and waiting for two additional days drops the dose rates significantly. Seven days following a 20-MJ shot, dose rates in the immediate vicinity of the retracted components drop to <0.2 mSv/h and the general ambient dose rates within the TB (away from retracted components) near the TC drop to <10 μSv/h. Dose rates at much larger distances from the TC (near TB wall) are an order of magnitude lower. Detailed radiation transport simulations are performed to create detailed dose rate maps for all floors inside the TB. The maps are used to measure worker stay-out times following shots before entry is permitted into the TB.

61 RADIATION PROTECTION AND DOSIMETRY↗

X-Ray Diffraction Measurements on Laser-Compressed Polycrystalline Samples Using a Short-Pulse Laser Generated X-Ray Source

Existing models for most materials do not describe phase transformations and associated lattice dy- namics (kinetics) under extreme conditions of pressure and temperature. Dynamic x-ray diffraction (DXRD) allows material investigations in situ on an atomic scale due to the correlation between solid-state structures and their associated diffraction patterns. In this LDRD project we have devel- oped a nanosecond laser-compression and picosecond-to-nanosecond x-ray diffraction platform for dynamically-compressed material studies. A new target chamber in the Target Bay in building 983 was commissioned for the ns, kJ Z-Beamlet laser (ZBL) and the 0.1 ns, 250 J Z-Petawatt (ZPW) laser systems, which were used to create 8-16 keV plasma x-ray sources from thin metal foils. The 5 ns, 15 J Chaco laser system was converted to a high-energy laser shock driver to load material samples to GPa stresses. Since laser-to-x-ray energy conversion efficiency above 10 keV is low, we employed polycapillary x-ray lenses for a 100-fold fluence increase compared to a conventional pinhole aperture while simultaneously reducing the background significantly. Polycapillary lenses enabled diffraction measurements up to 16 keV with ZBL as well as diffraction experiments with ZPW. This x-ray diffraction platform supports experiments that are complementary to gas guns and the Z facility due to different strain rates. Ultimately, there is now a foundation to evaluate DXRD techniques and detectors in-house before transferring the technology to Z. This page intentionally left blank.

36 MATERIALS SCIENCE↗

A laboratory investigation of potential double layers

In a triple plasma device, the injection of electron current from the source chamber to the target chamber causes the formation of a potential double layer. At a low current density, the space charge of the injected current produces a virtual cathode-type potential double layer. This double layer is stable, and various wave instabilities are observed to associate with this double layer. As the current density is increased, the double layer becomes unstable, and a moving double layer results. As the current density is increased further, the enhanced ionization causes the neutralization of the space charge of the electron beam, and the beam plasma discharge is ignited.

Leung, Philip↗

A laboratory investigation of potential double layers

In a triple plasma device, the injection of electron current from the source chamber to the target chamber causes the formation of a potential double layer. At a low current density, the space charge of the injected current produces a virtual cathode-type potential double layer. This double layer is stable and various wave instabilities are observed to associate with this double layer. As the current density is increased, the double layer becomes unstable and a moving double layer results. As the current density is increased further, the enhanced ionization causes the neutralization of the space charge of the electron beam and the 'beam plasma discharge' is ignited.

Leung, Philip↗

Cryogenic target system for hydrogen layering

Here, a cryogenic target positioning system was designed and installed on the National Ignition Facility (NIF) target chamber. This instrument incorporates the ability to fill, form, and characterize the NIF targets with hydrogen isotopes needed for ignition experiments inside the NIF target bay then transport and position them in the target chamber. This effort brought to fruition years of research in growing and metrologizing high-quality hydrogen fuel layers and landed it in an especially demanding operations environment in the NIF facility. D-T (deuterium-tritium) layers for NIF ignition experiments have extremely tight specifications and must be grown in a very highly constrained environment: a NIF ignition target inside a cryogenic target positioner inside the NIF target bay. Exquisite control of temperature, pressure, contaminant level, and thermal uniformity are necessary throughout seed formation and layer growth to create an essentially-groove-free single crystal layer.

42 ENGINEERING↗