At least 19 records

Combined TDLAS and chemiluminescence imaging in a flat flame burner operated with NH3/H2 blends

Ammonia is viewed as a viable hydrogen carrier due to favorable storage and transport characteristics. While it can be re-converted to hydrogen at point-of-use via thermal catalytic cracking, direct utilization in combustion systems can result in reduced costs and improved efficiency. A major barrier to this approach is the low flammability and potential for high nitrogen oxide emissions, driven by fuel-bound nitrogen and complex kinetic pathways. While a number of kinetic mechanisms currently exist for simulating ammonia combustion, a major need continues to be direct information about species profiles in easy-to-model systems capable of isolating chemical kinetics from multi-dimensional fluid dynamic effects. This paper reports on recent species measurements made in a flat flame burner using a combined tunable-diode-laser-absorption-spectroscopy (TDLAS) and chemiluminescence imaging approach. Three flame conditions were included representative of NH3/H2 blends, partially cracked NH3 (inc. N2), and 100% NH3 with enhanced air (30% oxygen). Two NIR distributed feedback (DFB) laser diodes were used to determine H2O concentration and temperature (via ratio thermometry) at various radial and axial positions, after which an inverse Abel transform was used to infer centerline values. Companion images were collected using a Princeton Instrument PI-MAX intensified camera equipped with a 105mm UV lens and multiple filter sets targeting OH*, NH*, and NH2* emission. Results were compared to companion Cantera burner-stabilized flame simulations using various kinetic mechanisms. A recent mechanism including excited species chemistry was also included, to investigate whether excited and ground state profiles exhibit significant differences.

ammonia combustion↗

Development of TDLAS for Water Vapor Concentration Measurement during VHTR Steam Ingress

Very-high-temperature reactors (VHTR) utilize a graphite-moderated, helium-cooled design that provides higher efficiencies and a low-carbon source of process heat (>700 deg. C) for many industrial applications. Safety concerns have led to extensive accident condition investigations. Steam generator heat-exchanger tube rupture accidents (SGTR) can lead to increased reactor core steam density, which causes neutron slowing-down and chemical corrosion of the graphite fuel elements and structural columns. It is important to be able to computationally model the propagation of steam throughout the lower plenum and nuclear reactor core, but experimental data is needed to validate such models. The primary objective of this project is to instrument a scaled down experiment of a VHTR designed by Ohio State University (OSU), with tunable diode laser absorption spectroscopy (TDLAS) diagnostics to measure steam concentration changes and map how water vapor propagates through the test facility's lower plenum and core. The basic principle of absorption spectroscopy is based on a molecular species ability to absorb photons of specific energies. A collimated laser beam of known energy is passed through a test section containing a sample gas. When a transition of the absorbing gas species resonates with the laser frequency, a certain amount of energy will be absorbed based on the rovibrational characteristics of the molecule. The intensity of the transmitted laser light can be measured by a detector after exiting the test section. The Beer-Lambert Law of absorbance is used to recover this information relating beam attenuation to the system dimensions, gas composition, pressure, and temperature. The line-strength is a function of temperature alone and relates the fraction of molecules in a given rovibrational state through the partition function. The partition function describes the statistical properties of a system in thermodynamic equilibrium where the states obey a Boltzmann distribution. Thus, the number density of molecules in a particular state can be determined from the total internal partition function at a particular temperature. The lineshape function of a given absorption transition is derived from the physical interaction between the absorbing species and is dependent on temperature and pressure. Random thermal motion of absorbing molecules result in broadening of the linewidth, called Doppler broadening, which follows a Gaussian distribution. Molecular collisions result in broadening and shifting of the linewidth, called pressure broadening, which follows a Lorentzian distribution. The overall lineshape results in a Voigt profile, which is a convolution of the Gaussian and Lorentzian distributions. The Voigt profile does not have a simple analytical form and is most often calculated numerically or approximated by complex functions. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Compact TDLAS based optical sensor for ppb-level ethane detection by use of a 3.34 μm room-temperature CW interband cascade laser

A mid-infrared ethane (C 2 H 6 ) sensor based on a wavelength modulation spectroscopy (WMS) technique was developed using a thermoelectrically cooled (TEC), continuous-wave (CW) interband cascade laser (ICL) emitting at 3.34 μm and a dense multi-pass gas cell (MPGC, 17 × 6.5 × 5.5 cm 3 ) with a 54.6 m optical path length. A compact optical sensor system with a physical size of 35.5 × 18 × 12.5 cm 3 was designed and constructed. An ICL was employed for targeting a strong C 2 H 6 line at 2996.88 cm -1 at <100 Torr gas pressure in the fundamental absorption band of C 2 H 6 . The sensor performance, including the minimum detection limit (MDL) and the stability were improved by reducing the effect of laser power drift by means of the 2f/1f-WMS technique. A MDL of ~1.2 parts per billion (ppbv) for 2f-WMS and ~1.0 ppbv for 2f/1f-WMS were achieved, respectively, with a measurement time of 4 s. The MDL was further improved from 299 pptv (@108 s for 2f-WMS) to 239 pptv (@208 s for 2f/1f-WMS), based on an Allan deviation analysis.The rise time (@0 → 100 ppbv) and fall time (@100 → 0 ppbv) were determined to be ~64 s and ~48 s,respectively, at a gas pressure of <100 Torr for the C 2 H 6 sensor operation.

03 NATURAL GAS↗

Liquid film thickness measurement by two-line TDLAS

A fiber-based two-line tunable diode-laser absorption sensor with two near-infrared (NIR) distributed-feedback (DFB) diode lasers at ∼1.4 μm was used for non-intrusive time-resolved liquid water film thickness measurement. When probing the liquid film at two different wavelengths with significantly different absorption cross-sections, the additional signal losses due to surface fowling, reflection and beam steering can be eliminated. In this work, the evaporation process of a liquid film on transparent quartz plate was tracked and large fluctuations of film thickness were found at the end of the evaporation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combined TDLAS and chemiluminescence imaging in a flat flame burner operated with NH3/H2 blends

Ammonia is a promising hydrogen carrier due to its favorable storage and transport characteristics. However, its direct use in combustion systems is limited by low flammability and potential for high nitrogen oxide emissions. To better understand ammonia combustion, researchers conducted experiments using a flat flame burner and measured species profiles using tunable-diode-laser-absorption-spectroscopy and chemiluminescence imaging. They tested three flame conditions with different ammonia-hydrogen blends and oxygen levels. The results were compared to simulations using various kinetic mechanisms, including one that accounts for excited species chemistry. The goal is to provide direct information about species profiles in a simple system, isolating chemical kinetics from fluid dynamic effects, which can inform the development of more efficient and low-emission combustion systems using ammonia.

ammonia combustion↗

In situ metrology to characterize water vapor delivery during atomic layer deposition

Water is often employed as the oxygen source in metal oxide atomic layer deposition (ALD) processes. It has been reported that variations in the amount of water delivered during metal oxide ALD can impact the oxide film properties. Hence, one contribution to optimizing metal oxide ALD processes would be to identify methods to better control water dose. The development of rapid, quantitative techniques for in situ water vapor measurements during ALD processes would be beneficial to achieve this goal. In this report, the performance of an in situ tunable diode laser absorption spectroscopy (TDLAS) scheme for performing rapid, quantitative water partial pressure measurements in a representative quarter-inch ALD delivery line is described. This implementation of TDLAS, which utilizes a near-infrared distributed-feedback diode laser and wavelength modulation spectroscopy, provides measurements of water partial pressure on a timescale comparable to or shorter than the timescale of the gas dynamics in typical ALD systems. Depending on the degree of signal averaging, this TDLAS system was capable of measuring the water partial pressure with a detection limit in the range of ∼0.80 to ∼0.08 Pa. The utility of this TDLAS scheme was demonstrated by using it to identify characteristics of a representative water delivery system that otherwise would have been difficult to predict. Those characteristics include (1) the magnitude and time dependence of the pressure transient that can occur during water injection, and (2) the dependence of the steady-state water partial pressure on the carrier gas flow rate and the setting of the water ampoule flow restriction.

42 ENGINEERING↗

Tunable-diode laser absorption spectrometry

Tunable-diode laser absorption spectrometry (TDLAS) affords a number of advantages for atmospheric measurements. It is a universal method, applicable, in principle, to all gases of atmospheric interest. Because of its extremely high spectral resolution it provides unequivocal identification of the target species, with no interferences from other gases. It provides real-time, in situ measurements with time resolutions better than 1 minute. The sensitivity of the current TDLAS system is marginally capable of measuring HO2. This species exists in the troposphere at concentrations which are up to 2 orders of magnitude higher than those of HO and, in addition, is much less susceptible to removal by the surfaces of the instrument and its sampling system. HO2 is an important HO sub x species in its own right but can also give direct information on the HO concentration by virtue of the rapid partitioning between these two species. The addition of the high-frequency modulation technique to the TDLAS system would ensure its ability to measure HO2 under most atmospheric conditions. The ability of the TDLAS to measure hydrogen peroxide (H2O2) in the ambient atmosphere was also demonstrated. H2O2 measurements give a clear indication of HO sub x mixing ratios and are also important as a photolytic source of HO and as an important oxidant for other atmospheric consitituents such as SO2.

Schiff, H. I.↗

Spatially Resolved Temperature and Water Vapor Concentration Distributions in Supersonic Combustion Facilities by TDLAT

Detailed knowledge of the internal structure of high-enthalpy flows can provide valuable insight to the performance of scramjet combustors. Tunable Diode Laser Absorption Spectroscopy (TDLAS) is often employed to measure temperature and species concentration. However, TDLAS is a path-integrated line-of-sight (LOS) measurement, and thus does not produce spatially resolved distributions. Tunable Diode Laser Absorption Tomography (TDLAT) is a non-intrusive measurement technique for determining two-dimensional spatially resolved distributions of temperature and species concentration in high enthalpy flows. TDLAT combines TDLAS with tomographic image reconstruction. More than 2500 separate line-of-sight TDLAS measurements are analyzed in order to produce highly resolved temperature and species concentration distributions. Measurements have been collected at the University of Virginia's Supersonic Combustion Facility (UVaSCF) as well as at the NASA Langley Direct-Connect Supersonic Combustion Test Facility (DCSCTF). Due to the UVaSCF s unique electrical heating and ability for vitiate addition, measurements collected at the UVaSCF are presented as a calibration of the technique. Measurements collected at the DCSCTF required significant modifications to system hardware and software designs due to its larger measurement area and shorter test duration. Tomographic temperature and water vapor concentration distributions are presented from experimentation on the UVaSCF operating at a high temperature non-reacting case for water vitiation level of 12%. Initial LOS measurements from the NASA Langley DCSCTF operating at an equivalence ratio of 0.5 are also presented. Results show the capability of TDLAT to adapt to several experimental setups and test parameters.

Busa, K. M.↗

Measurements on NASA Langley Durable Combustor Rig by TDLAT: Preliminary Results

Detailed knowledge of the internal structure of high-enthalpy flows can provide valuable insight to the performance of scramjet combustors. Tunable Diode Laser Absorption Spectroscopy (TDLAS) is often employed to measure temperature and species concentration. However, TDLAS is a path-integrated line-of-sight (LOS) measurement, and thus does not produce spatially resolved distributions. Tunable Diode Laser Absorption Tomography (TDLAT) is a non-intrusive measurement technique for determining two-dimensional spatially resolved distributions of temperature and species concentration in high enthalpy flows. TDLAT combines TDLAS with tomographic image reconstruction. Several separate line-of-sight TDLAS measurements are analyzed in order to produce highly resolved temperature and species concentration distributions. Measurements have been collected at the University of Virginia's Supersonic Combustion Facility (UVaSCF) as well as at the NASA Langley Direct-Connect Supersonic Combustion Test Facility (DCSCTF). Measurements collected at the DCSCTF required significant modifications to system hardware and software designs due to its larger measurement area and shorter test duration. Initial LOS measurements from the NASA Langley DCSCTF operating at an equivalence ratio of 0.5 are presented. Results show the capability of TDLAT to adapt to several experimental setups and test parameters.

Busa, Kristin↗

Laser Absorption Spectroscopy Measurements of Post-Shock Non-Equilibrium Species in the NASA Ames Electric Arc Shock Tube

The NASA Ames Electric Arc Shock Tube (EAST) is a unique facility capable of generating high enthalpy, shock-heated impulse gas flows representative of the kinetic and radiative conditions encountered by atmospheric entry vehicles. The facility maintains a successful history with emission spectroscopy, providing measurements of absolute radiance upon which various validation studies are anchored. The central objective of this work is to develop a comprehensive tunable diode laser absorption spectroscopy (TDLAS) sensing capability to provide complementary experimental insights to existing emission techniques. More specifically, a fast-scanning TDLAS-based diagnostic targeting the cyano radical (CN) in the near-infrared(near-IR) near 926.6 nm is employed in mixtures of 2.2% CH4in N2by mole for a sweep of incident shock velocities ranging 3.0-5.5 km/s and fill pressures 0.3-1.15 Torr. Laser scan rates up to 500 kHz probe multiple absorption features to provide quantitative measurements of temperature and species number density profiles behind the incident shock. In all instances, the temperature trend is consistent between emission-inferred and TDLAS-inferred measurements. However, at the lower-velocity conditions, there is an appreciable offset between the Data Parallel Line Relaxation Code (DPLR) simulation and experimental measurements. A similar behavior is observed in number density profiles, with emission measurements providing inferences of the CN(B) and CN(A) state, while TDLAS measurements provide an additional inference of the CN(X) state. In the fast-scanned experiments, measurement inferred number densities suggest a much faster production of CN at early times than captured by the model. This discrepancy motivates ongoing, additional spectroscopic and kinetics CN experiments to resolve the accuracy of modeling assumptions.

Efaine Chang↗

Tunable diode laser absorption spectroscopy-based tomography system for on-line monitoring of two-dimensional distributions of temperature and H{sub 2}O mole fraction

To monitor two-dimensional (2D) distributions of temperature and H{sub 2}O mole fraction, an on-line tomography system based on tunable diode laser absorption spectroscopy (TDLAS) was developed. To the best of the authors’ knowledge, this is the first report on a multi-view TDLAS-based system for simultaneous tomographic visualization of temperature and H{sub 2}O mole fraction in real time. The system consists of two distributed feedback (DFB) laser diodes, a tomographic sensor, electronic circuits, and a computer. The central frequencies of the two DFB laser diodes are at 7444.36 cm{sup −1} (1343.3 nm) and 7185.6 cm{sup −1} (1391.67 nm), respectively. The tomographic sensor is used to generate fan-beam illumination from five views and to produce 60 ray measurements. The electronic circuits not only provide stable temperature and precise current controlling signals for the laser diodes but also can accurately sample the transmitted laser intensities and extract integrated absorbances in real time. Finally, the integrated absorbances are transferred to the computer, in which the 2D distributions of temperature and H{sub 2}O mole fraction are reconstructed by using a modified Landweber algorithm. In the experiments, the TDLAS-based tomography system was validated by using asymmetric premixed flames with fixed and time-varying equivalent ratios, respectively. The results demonstrate that the system is able to reconstruct the profiles of the 2D distributions of temperature and H{sub 2}O mole fraction of the flame and effectively capture the dynamics of the combustion process, which exhibits good potential for flame monitoring and on-line combustion diagnosis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Localization and Quantification of Trace-gas Fugitive Emissions Using a Portable Optical Spectrometer

We present a portable optical spectrometer for fugitive emissions monitoring of methane (CH4). The sensor operation is based on tunable diode laser absorption spectroscopy (TDLAS), using a 5 cm open path design, and targets the 2ν3 R(4) CH4 transition at 6057.1 cm-1 (1651 nm) to avoid cross-talk with common interfering atmospheric constituents. Sensitivity analysis indicates a normalized precision of 2.0 ppmv∙Hz-1/2, corresponding to a noise-equivalent absorption (NEA) of 4.4×10-6 Hz-1/2 and minimum detectible absorption (MDA) coefficient of αmin = 8.8×10-7 cm-1∙Hz-1/2. Our TDLAS sensor is deployed at the Methane Emissions Technology Evaluation Center (METEC) at Colorado State University (CSU) for initial demonstration of single-sensor based source localization and quantification of CH4 fugitive emissions. The TDLAS sensor is concurrently deployed with a customized chemi-resistive metal-oxide (MOX) sensor for accuracy benchmarking, demonstrating good visual correlation of the concentration time-series. Initial angle-of-arrival (AOA) results will be shown, and development towards source magnitude estimation will be described.

03 NATURAL GAS↗

Measurements of H2O, CO2, CO and Static Temperature inside Rotating Detonation Engines (RDEs)

A high-speed tunable-diode laser absorption spectrometer (TDLAS) for resolving gas composition and static temperature within rotating detonation engines (RDEs) was developed. A fixed-wavelength, direct absorption approach was taken to achieve the MHz speeds that are required to capture the fast transients present in the RDE flow field. Total pressure gain across an RDE has yet to be shown experimentally. Coupling these fast TDLAS measurements with velocimetry measurements would allow quantifying the total pressure across the combustor.

Rotating detonation engine, RDE, TDLAS, tunable-di↗

Time-resolved populations of N 2 (A 3 Σ u + ,v) in nanosecond pulse discharge plasmas

Absolute time-resolved populations of N 2 in the excited A 3 Σ u + electronic state that are generated in a repetitive ns pulse discharge in nitrogen have been measured by Cavity Ring Down Spectroscopy (CRDS) and Tunable Diode Laser Spectroscopy (TDLAS). CRDS measurements of N 2 (A 3 Σ u + ,v = 0–2) populations are made in the discharge afterglow at pressures of 22 and 39 Torr. The data reduction procedure takes into account the linewidth of the pulsed laser source, which is comparable with the absorption linewidth and results in a non-single exponential ring down decay. Peak N 2 (A 3 Σ u + ,v = 0–2) populations after a 10-pulse ns discharge burst are in the range of 10 12 –10 13 cm -3 . In the afterglow, these populations exhibit a relatively slow decay with the characteristic time of approximately 500 μs, most likely due to the quenching by N atoms. TDLAS data have been taken at a higher pressure of 132 Torr. Absolute time-resolved N 2 (A 3 Σ u + ,v = 0,1) number densities are measured during ns pulse discharge bursts up to 5 pulses long and in the afterglow, peaking at 6·10 12 cm -3 and 3·1013 cm -3 , respectively. The results indicate that N 2 (A 3 Σ u + ) is generated after every discharge pulse on a 20–50 μs time scale, much longer compared to the discharge pulse duration of ~100 ns, and subsequently decays between the pulses. The decay rate increases during the discharge burst. In the afterglow, N 2 (A 3 Σ u + ,v = 0,1) population decay significantly more rapidly compared to the low-pressure CRDS conditions, with the characteristic time of approximately 160 μs after a 5-pulse discharge burst.

74 ATOMIC AND MOLECULAR PHYSICS↗

Trace-gas Spectroscopy of Methane on a Silicon Photonic Chip

Recent advances in hybrid integrated silicon photonic (SiPh) technologies are enabling the migration of conventional free-space optical spectroscopic sensors onto a compact on-chip platform [1-3]. In addition to the small spatial footprint and power efficiency, we envision such sensors to be scalably manufactured using existing CMOS-compatible foundry processes, thus providing disruptive SWaP-C (size, weight, power, and cost) benefits in contrast to commercially available optical sensors. Initial demonstration of evanescent TDLAS (tunable diode laser absorption spectroscopy) of methane (CH4) on a passive SiPh waveguide has indicated minimum fractional absorption of (αL)min = 3.3×10-5 Hz-1/2, which is on-par with state-of-art open-path TDLAS sensor systems [4]. Given the general recent movement toward cleaner fuels, CH4 fugitive emissions monitoring is of significant interest given the extremely high radiative forcing potential [5]. For a nominal waveguide length of 30 cm with Γ = 25 % evanescent exposure, this corresponds to ~ 10 ppmv detection sensitivity at 1 s integration time, and further sensitivity enhancement is expected with even longer waveguides, as the laser RIN typically dominates our measurements at nominal waveguide lengths. Despite the excellent sensitivities for short-term integration periods, long-term measurements (> 10 s) are potentially limited on a silicon platform due to the high material thermo-optic coefficient, resulting in significant susceptibility of Fabry-Perot etalons to drift in the presence of even small (~ 1 mK) thermal fluctuations. To this end, customized spectral fitting algorithms have played a significant role in both fringe drift mitigation and peak detection fidelity (e.g. in the presence of a passing CH4 plume), which are crucial for enhancing long-term stability without the need for frequent sensor recalibration. A variety of spectral algorithms have been designed for this purpose, and details will be presented at the meeting.

03 NATURAL GAS↗

Experimental Investigation and CFD Analysis of Steam Ingress Accidents in HTGRs

This study focuses on the short-term phenomena due to steam ingress following an SG tube rupture accident in HTGRs, instead of covering a long-term scenario induced by a small amount of steam ingress during plant lifetime. Our ultimate goal is to better understand water/steam ingress accidents in HTGRs, where the Rankine cycle is adopted as the power conversion cycle. General Atomics’ 350 MWth Modular High Temperature Gas-cooled Reactor (MHTGR) was chosen as the prototypic reactor design. The models of steam nuclear graphite oxidation proposed in the literature are surveyed, and will be examined, validated or improved if needed. Furthermore, this study aims to develop and validate a predictive tool for steam ingress accidents. To measure the steam concentration evolution in an integral effect test (IET) facility, a tunable diode laser absorption spectroscopy (TDLAS) measurement system was developed. The TDLAS measuring system is a non-intrusive and non-perturbative diagnostic technique that can be used to measure the steam temperature and concentration at various conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Field Deployment of a Portable Optical Spectrometer for Methane Fugitive Emissions Monitoring on Oil and Gas Well Pads

We present field deployment results of a portable optical absorption spectrometer for localization and quantification of fugitive methane (CH 4 ) emissions. Our near-infrared sensor targets the 2$ν_3$ R(4) CH 4 transition at 6057.1 cm &minus;1 (1651 nm) via line-scanned tunable diode-laser absorption spectroscopy (TDLAS), with Allan deviation analysis yielding a normalized 2.0 ppmv∙Hz &minus;1/2 sensitivity (4.5 &times; 10 &minus;6 Hz &minus;1/2 noise-equivalent absorption) over 5 cm open-path length. Controlled CH 4 leak experiments are performed at the METEC CSU engineering facility, where concurrent deployment of our TDLAS and a customized volatile organic compound (VOC) sensor demonstrates good linear correlation (R 2 = 0.74) over high-flow (>60 SCFH) CH 4 releases spanning 4.4 h. In conjunction with simultaneous wind velocity measurements, the leak angle-of-arrival (AOA) is ascertained via correlation of CH 4 concentration and wind angle, demonstrating the efficacy of single-sensor line-of-sight (LOS) determination of leak sources. Finally, source magnitude estimation based on a Gaussian plume model is demonstrated, with good correspondence (R 2 = 0.74) between calculated and measured release rates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗