Search NASA⌕ Search

SEARCH · Search NASA

Results for “TECHNOLOGISTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Technologist in Residence for Advanced Manufacturing and Materials in Unconventional Oil and Gas Equipment and Infrastructure

The DOE Technologist in Residence (TIR) program pairs a senior technical staff member from a National Laboratory (Lab Technologist), and a senior technical staff member(s) from a clean energy manufacturing company or consortium of companies (Industry Technologist). Each technologist may represent single or multiple national laboratories, or single or multiple companies. These pairs of Lab and industry technologists work together for a period of 18 to 24 months to accomplish several goals: 1) Identify the participating company’s (or companies’) technical priorities and challenges, and the resources and capabilities in DOE’s National Laboratories that may be highly suitable to address them; 2) Propose collaborative R&D efforts to develop science-based solutions to the company’s (or companies’) most strategic scientific, technological, and business issues; and 3) Develop a general framework agreement and begin developing specific scopes of work for the proposed collaborative R&D efforts. The proposed R&D will then take place outside of the program and will not use TIR program funds. Oak Ridge National Laboratory (ORNL) and Pioneer Natural Resources were awarded a TIR project by DOE in late 2016 and the CRADA component of the project was initiated in 2017. This report describes work performed under the CRADA agreement between 2017 and 2020.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Inaugural Technologist in Communities Scanning Tour: Automated and Electrified On-Demand Mobility (Follow-On Summary Report: April 24-25, 2023) [Slides]

In 2023, the Technologist in Communities (TIC) program hosted its inaugural scanning tour across the American Southwest, with a goal of investigating the region's leading public mobility systems and their integration with on-demand public mobility services. The scanning tour concept was inspired by and named after a U.S. Department of Transportation Federal Highway Administration practice of hosting "scanning tours," both domestically and abroad, to explore innovative transportation practices throughout the 1990s and early 2000s. Guided by the idea that "seeing is believing," scanning tours created opportunities for government and industry representatives to collectively experience new technologies and best practices firsthand. In 2023, the National Renewable Energy Laboratory (NREL) followed suit by leading the inaugural TIC scanning tour. TIC, part of the Technology Integration program within the U.S. Department of Energy's (DOE's) Vehicle Technologies Office, supports positive energy and mobility outcomes in communities across rural to urban contexts. TIC enables technical experts to work directly with leaders and stakeholders in communities and assist them in implementing promising new technologies. This first TIC scanning tour invited NREL, DOE, and industry experts to survey innovative public mobility practices and their integration into public transit systems across the Southwest. The tour's goals included examining the state of innovation in public mobility in cities, communities, and airports; facilitating collaboration between entities; and sparking potential new partnerships. The following report summarizes key findings from the scanning tour.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MO-DE-BRA-01: Flipped Physics Courses Within a Radiologic Technologist Program: Video Production and Long Term Outcomes

Purpose: To determine if the flipped class format has an effect on examination results for a radiologic technologist (RT) program and discuss benefits from creating video resources. Methods: From 2001–2015, students had taken both a radiological physics and quality control (QC) class as a part of their didactic training. In 2005/2006, the creation of videos of didactic lectures and QC test demonstrations allowed for a flip where content was studied at home while exercises and reviews were done in-class. Final examinations were retrospectively reviewed from this timeframe. 12 multiple choice physics questions (MCP) and 5 short answer QC questions (SAQC) were common to pre and post flip exams. The RT program’s ARRT exam scores were also obtained and compared to national averages. Results: In total, 36 lecture videos and 65 quality control videos were created for the flipped content. Data was ∼2.4GB and distributed to students via USB or CD media. For MCP questions, scores improved by 7.9% with the flipped format and significance (Student’s t-test, p<0.05) was found for 3 of the 12 questions. SAQC questions showed improvement by 14.6% and significance was found for 2 of the 5 questions. Student enrollment increased from ∼14 (2001–2004) to ∼23 students (2005–15). Content was continuously added post-flip due to the efficiency of delivery. The QC class in 2003 covered 45 test setups in-class while 65 were covered with video segments in 2014. Flipped materials are currently being repurposed. In 2015, this video content was restructured into an ARRT exam review guide and in 2016, the content was reorganized for fluoroscopy training for physicians. Conclusion: We believe that flipped classes can improve efficiency of content delivery and improve student performance even with an increase in class size. This format allows for flexibility in learning as well as re-use in multiple applications.

07 ISOTOPE AND RADIATION SOURCES↗

Acceptable Knowledge Technologist Procedure

Process acceptable knowledge (AK) is a waste stream characterization method that can be used to meet all or part of the waste analysis requirements appropriate for the waste. The method may include documented knowledge of process (KOP), additional characterization data, and/or facility records of analysis. LANL will use process AK to ensure chemical compatibility; assign matrix parameter categories and Environmental Protection Agency (EPA) hazardous waste numbers (HWNs) commonly referred to as EPA codes to waste streams; and determine the waste material parameters and radionuclides present in waste streams.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-F-P-06: Moving From Computed Radiography to Digital Radiography: A Collaborative Approach to Improve Image Quality

Purpose: To bring together radiologists, technologists, and physicists to utilize post-processing techniques in digital radiography (DR) in order to optimize image acquisition and improve image quality. Methods: Sub-optimal images acquired on a new General Electric (GE) DR system were flagged for follow-up by radiologists and reviewed by technologists and medical physicists. Various exam types from adult musculoskeletal (n=35), adult chest (n=4), and pediatric (n=7) were chosen for review. 673 total images were reviewed. These images were processed using five customized algorithms provided by GE. An image score sheet was created allowing the radiologist to assign a numeric score to each of the processed images, this allowed for objective comparison to the original images. Each image was scored based on seven properties: 1) overall image look, 2) soft tissue contrast, 3) high contrast, 4) latitude, 5) tissue equalization, 6) edge enhancement, 7) visualization of structures. Additional space allowed for additional comments not captured in scoring categories. Radiologists scored the images from 1 – 10 with 1 being non-diagnostic quality and 10 being superior diagnostic quality. Scores for each custom algorithm for each image set were summed. The algorithm with the highest score for each image set was then set as the default processing. Results: Images placed into the PACS “QC folder” for image processing reasons decreased. Feedback from radiologists was, overall, that image quality for these studies had improved. All default processing for these image types was changed to the new algorithm. Conclusion: This work is an example of the collaboration between radiologists, technologists, and physicists at the University of New Mexico to add value to the radiology department. The significant amount of work required to prepare the processing algorithms, reprocessing and scoring of the images was eagerly taken on by all team members in order to produce better quality images and improve patient care.

60 APPLIED LIFE SCIENCES↗

Health Literacy and Patient Preparation in Radiology

Health literacy is the capacity of an individual to obtain, process, and understand basic health information and services needed to make appropriate health decisions. Unfortunately, more than half of Canadians cannot adequately navigate the health care system because they have limited health literacy. Patients with low health literacy may have limited reading abilities and poorer comprehension of written preparation documents. An important consideration in the radiation sciences for these patients is the ability to follow preparation requirements for diagnostic imaging procedures. It has been suggested that patients with limited health literacy are often less prepared for diagnostic examinations, and as a result, tend to have examinations of poorer diagnostic quality. Medical radiation technologists play an important role in educating patients regarding medical imaging examinations and helping them to properly prepare for these procedures. The purpose of this article is to define health literacy, provide some practical strategies to help medical radiation technologists identify patients with limited health literacy, and how to address limited health literacy issues to improve the quality of diagnostic imaging examinations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-H-206-01: An Automated Approach for Identifying Geometric Distortions in Gamma Cameras

Purpose: To develop a clinically-deployable, automated process for detecting artifacts in routine nuclear medicine (NM) quality assurance (QA) bar phantom images. Methods: An artifact detection algorithm was created to analyze bar phantom images as part of an ongoing QA program. A low noise, high resolution reference image was acquired from an x-ray of the bar phantom with a Philips Digital Diagnost system utilizing image stitching. NM bar images, acquired for 5 million counts over a 512×512 matrix, were registered to the template image by maximizing mutual information (MI). The MI index was used as an initial test for artifacts; low values indicate an overall presence of distortions regardless of their spatial location. Images with low MI scores were further analyzed for bar linearity, periodicity, alignment, and compression to locate differences with respect to the template. Findings from each test were spatially correlated and locations failing multiple tests were flagged as potential artifacts requiring additional visual analysis. The algorithm was initially deployed for GE Discovery 670 and Infinia Hawkeye gamma cameras. Results: The algorithm successfully identified clinically relevant artifacts from both systems previously unnoticed by technologists performing the QA. Average MI indices for artifact-free images are 0.55. Images with MI indices < 0.50 have shown 100% sensitivity and specificity for artifact detection when compared with a thorough visual analysis. Correlation of geometric tests confirms the ability to spatially locate the most likely image regions containing an artifact regardless of initial phantom orientation. Conclusion: The algorithm shows the potential to detect gamma camera artifacts that may be missed by routine technologist inspections. Detection and subsequent correction of artifacts ensures maximum image quality and may help to identify failing hardware before it impacts clinical workflow. Going forward, the algorithm is being deployed to monitor data from all gamma cameras within our health system.

60 APPLIED LIFE SCIENCES↗

DOE's National Solar Thermal Test Facility Operations and Maintenance (Final Report FY19-21)

Sandia National Laboratories has been tasked to operate and maintain the National Solar Thermal Test Facility (NSTTF) located in Kirtland Airforce Base near Albuquerque, NM. The NSTTF provides established test platforms and experienced researchers and technologists in the field of Concentrating Solar Technologies (CST) and Concentrating Solar Power (CSP). This three-year project seeks to maintain the NSTTF for development, testing, and application of new CSP technologies that are instrumental in advancing the state-of-the-art in support of SunShot and Generation 3 CSP technology goals. In turn, these technologies will form the foundation of the global CSP industry and continue to advance the technology to new levels of efficiency, higher temperatures, lower costs, lower risk, and higher reliability. The NSTTF provides established test platforms and highly experienced researchers and technologists in the CSP field.

14 SOLAR ENERGY↗

A General Framework for Monitoring Image Acquisition Workflow in the Radiology Environment: Timeliness for Acute Stroke CT Imaging

Many facets of an image acquisition workflow leave a digital footprint, making workflow analysis amenable to an informatics-based solution. This paper describes a detailed framework for analyzing workflow and uses acute stroke response timeliness in CT as a practical demonstration. We review methods for accessing the digital footprints resulting from common technologist/device interactions. This overview lays a foundation for obtaining data for workflow analysis. We demonstrate the method by analyzing CT imaging efficiency in the setting of acute stroke. We successfully used digital footprints of CT technologists to analyze their workflow. We presented an overview of other digital footprints including but not limited to contrast administration, patient positioning, billing, reformat creation, and scheduling. A framework for analyzing image acquisition workflow was presented. This framework is transferable to any modality, as the key steps of image acquisition, image reconstruction, image post processing, and image transfer to PACS are common to any imaging modality in diagnostic radiology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental Study on the Porosity of Electron Beam Melting-Manufactured Ti6Al4V

Electron beam melting (EBM) is one of the powder bed fusion technologies, which utilizes a high-energy electron beam, as a moving heat source, in order to melt (by rapid self-cooling) metal powder and produce parts in a layer-building fashion. Anyway, many technical aspects concerning the quality of EBM-produced components are still industrial open items and studies need to be carried out. In accordance with the industrial needs, in this work researchers have studied the influence of two process parameters, i.e., samples orientation and height in the build chamber. The experiments have consisted in rectangular parallelepiped (50 × 10 × 10 mm) samples Ti6Al4V produced by EBM following a two-factor DOE. A tomographic investigation of all the samples produced by EBM has been carried out in order to get a complete set of data on porosity defects that have been analyzed showing the influence of process parameters on the porosity generation and pointing out typical features of defect distributions. The results obtained from this work have given precious information to designers and EBM technologists in order to: optimize the components’ design and the building setup obtaining a manufacturing process with the minimal level of porosity defects (best growth orientation). provide information for mechanical post-processing (metal removal).

36 MATERIALS SCIENCE↗

Enhanced Mechanical Properties and Wear Resistance of FeCrAl Alloys at ~ 300°C and Higher Temperatures

Abstract Worldwide, light water reactors (LWRs) have been using zirconium (Zr)-based alloys for the cladding of the uranium dioxide fuel for more than 6 decades. Zr alloys oxidize rapidly in the presence of water and steam at temperatures > 450°C; therefore, they do not respond well to scenarios of loss of coolant accidents. There is a global effort by nuclear materials technologists to find more robust or stronger cladding materials for LWRs. One option is to use an iron-chromium-aluminum (FeCrAl) alloy since they have excellent resistance to high temperature oxidation and superior mechanical properties at LWR operation temperatures. Results show that (1) FeCrAl alloys have better mechanical properties than Zr alloy and are orders of magnitude more resistant to creep at temperatures higher than LWR normal operation conditions. (2) FeCrAl alloys have better resistance to fretting wear than Zr alloys at the normal operation conditions of LWRs.

Materials Science↗

Reliability of the {sup 123}I-mIBG heart/mediastinum ratio: Results of a multicenter test–retest reproducibility study

A quantitative measurement, the Heart-to-Mediastinum (H/M) ratio of counts derived from a planar acquisition approximately 4 hours after injection of {sup 123}I-mIBG, is a strong predictor of outcomes in patients with stable class II-III heart failure and LVEF ≤ 35%. This study assessed the test–retest reproducibility of the H/M ratio in such patients. 47 subjects with class II-III systolic heart failure and LVEF ≤ 35% were tested at two time intervals separated by 5 to 14 days. Subjects were imaged twice on the same camera using the same radionuclide dose. Images were sent to a core analysis lab, where three nuclear technologists independently determined the H/M ratios. The primary endpoint was test–retest H/M ratio reproducibility calculated as the absolute difference in mean value determined by the three readers. Mean subject age was 65 ± 12 years, 85% were male, and mean BMI was 29 ± 6 kg/m{sup 2}. Mean injected activity was 10.18 ± 0.43 mCi for first dose and 10.09 ± 0.52 mCi for the second dose. The mean and SD values for first and repeat studies were almost identical: the 95% confidence interval of the mean test–retest difference was 0.055 to 0.076. Bland–Altman plots showed no systematic effect of the H/M ratio on the magnitude of the difference between replicate measurements. Inter-reader measurements were nearly identical. There were no serious adverse events despite exposure to {sup 123}I-mIBG on 2 occasions in a short time period. The Heart-to-Mediastinum ratio of {sup 123}I-mIBG is a consistent and highly reproducible measurement in stable Class II to III heart failure patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective study of ultraviolet radiation exposure and risk of breast cancer in the United States

Although there are few environmental risk factors for breast cancer, some epidemiologic studies found that exposure to solar UV radiation (UVR) may lower risk. Prior epidemiologic studies are limited by narrow ambient UVR ranges and lack lifetime exposure assessment. To address these issues, we studied a cohort with residences representing a wide range of ambient UVR. Using the nationwide U.S. Radiologic Technologists study (USRT), we examined the association between breast cancer risk and UVR based on ambient UVR, time outdoors, a combined variable of ambient UVR and time outdoors (combined UVR), and sun susceptibility factors. Participants reported location of residence and hours spent outdoors during five age periods. Ambient UVR was derived by linking satellite-based annual UVR estimates to self-reported residences. Lifetime values were calculated by averaging these measures accounting for years spent in that location. We examined the risk of breast cancer among 36,725 participants (n=716 cases) from baseline questionnaire completion (2003–2005) through 2012–2013 using Cox proportional hazards models. Breast cancer risk was unrelated to ambient UVR (HR for lifetime 5th vs 1st quintile=1.22, 95% CI: 0.95–1.56, p-trend=0.36), time outdoors (HR for lifetime 5th vs 1st quintile=0.87, 95% confidence interval (CI): 0.68–1.10, p-trend=0.46), or combined UVR (HR lifetime 5th vs 1st quintile =0.85, 95% CI: 0.67–1.08, p-trend=0.46). Breast cancer risk was not associated with skin complexion, eye or hair color, or sunburn history. This study does not support the hypothesis that UVR exposure lowers breast cancer risk. - Highlights: • Prior studies of UVR and breast cancer are inconsistent and limited. • We assessed UVR exposure across the lifetime and in three ways. • Conducted a prospective analysis of UVR exposure and breast cancer risk. • No association of any UVR exposure metric at any age with breast cancer risk. • Our findings suggest UVR exposure does not reduce risk of breast cancer.

54 ENVIRONMENTAL SCIENCES↗

A Roadmap and Cost Implications of Establishing Comprehensive Cancer Care Using a Teleradiotherapy Network in a Group of Sub-Saharan African Countries With No Access to Radiation Therapy

Purpose: To propose a roadmap and explore the cost implications of establishing a teleradiotherapy network to provide comprehensive cancer care and capacity building in countries without access to radiation therapy. Methods and Materials: Ten low-income sub-Saharan countries with no current radiation therapy facilities were evaluated. A basic/secondary radiation therapy center (SRTC) with 2 teletherapy, 1 brachytherapy, 1 simulator, and a treatment planning facility was envisaged at a cost of 5 million US dollars (USD 5M). This could be networked with 1 to 4 primary radiation therapy centers (PRTC) with 1 teletherapy unit, each costing USD 2M. The numbers of PRTCs and SRTCs for each country were computed on the basis of cancer incidence, assuming that a PRTC and SRTC could respectively treat 450 and 900 patients annually. Results: An estimated 71,215 patients in these countries will need radiation therapy in 2020. Stepwise establishment of a network with 99 PRTCs and 28 SRTCs would result in 155 teletherapy units and 96% access to radiation therapy. A total of 310 radiation oncologists, 155 medical physicists, and 465 radiation therapy technologists would be needed. Capacity building could be undertaken through telementoring by networking to various international institutions and professional societies. Total infrastructure costs would be approximately USD 860.88M, only 0.94% of the average annual gross domestic product of these 10 countries. A total of 1.04 million patients could receive radiation therapy during the 15-year lifespan of a teletherapy unit for an investment of USD 826.69 per patient. For the entire population of 218.32 million, this equates to USD 4.11 per inhabitant. Conclusion: A teleradiotherapy network could be a cost-contained innovative health care strategy to provide effective comprehensive cancer care through resource sharing and capacity building. The network could also be expanded to include other allied specialties. The proposal calls for active coordination between all national and international organizations backed up by strong geopolitical commitment and action from all stakeholders.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An evaluation of complementary approaches to elucidate fundamental interfacial phenomena driving adhesion of energetic materials

In this study, cohesive Hamaker constants of solid materials are measured via optical and dielectric properties (i.e., Lifshitz theory), inverse gas chromatography (IGC), and contact angle measurements. To date, however, a comparison across these measurement techniques for common energetic materials has not been reported. This has been due to the inability of the community to produce samples of energetic materials that are readily compatible with contact angle measurements. Here we overcome this limitation by using physical vapor deposition to produce thin films of five common energetic materials, and the contact angle measurement approach is applied to estimate the cohesive Hamaker constants and surface energy components of the materials. The cohesive Hamaker constants range from 85 zJ to 135 zJ across the different films. When these Hamaker constants are compared to prior work using Lifshitz theory and nonpolar probe IGC, the relative magnitudes can be ordered as follows: contact angle > Lifshitz > IGC. Furthermore, the dispersive surface energy components estimated here are in good agreement with those estimated by IGC. Due to these results, researchers and technologists will now have access to a comprehensive database of adhesion constants which describe the behavior of these energetic materials over a range of settings.

36 MATERIALS SCIENCE↗