Soldering iron temperature indicator
Thermocouple implanted in metal mass simulates heat transfer characteristics of connection which is to be soldered. Light signals indicate whether temperature is right, too high, or too low.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Thermocouple implanted in metal mass simulates heat transfer characteristics of connection which is to be soldered. Light signals indicate whether temperature is right, too high, or too low.
One of the nondestructive thermography inspection techniques uses photographic flashlamps. The flashlamps provide a short duration (about 0.005 sec) heat pulse. The short burst of energy results in a momentary rise in the surface temperature of the part. The temperature rise may be detrimental to the top layer of the part being exposed. Therefore, it is necessary to ensure the nondestructive nature of the technique. Amount of the temperature rise determines whether the flashlamp heating would be detrimental to the part. A direct method for the temperature measurement is to use of an infrared pyrometer that has much shorter response time than the flash duration. In this paper, an alternative technique is given using the irreversible temperature 'indicators. This is an indirect technique and it measures the temperature rise on the irreversible temperature indicators and computes the incident heat flux. Once the heat flux is known, the temperature rise on the part can be computed. A wedge shaped irreversible temperature indicator for measuring the heat flux is proposed. A procedure is given to use the wedge indicator.
Patches of braze alloys having known fusion are applied to portions of a metal surface where temperature indicators are required. This method is used to measure temperatures over the range of 175 degrees to 2100 degrees fahrenheit where it is not feasible to employ conventional temperature detectors.
The ratio of intensities of hydrogen Balmer lines H-alpha/H-beta is proposed as an indicator of electron temperature in a nonequilibrium plasma. Although different from the equilibrium case, the intensity ratio is a unique function of electron temperature provided that the optical depth is small for the visible lines and the plasma is far out of equilibrium. For such a plasma, the H-alpha/H-beta intensity ratios are computed. The results are tabulated in the form of a conversion table between the measured excitation temperature and the true electron temperature. The ranges of applicability of the conversion table are also computed and are presented in separate tables. An example is shown in which particle densities are consistent with the Saha equilibrium condition at the apparent excitation temperature even though the plasma is in nonequilibrium at a different true electron temperature.
High crystallization temperatures for igneous rocks from Tranquillity Base indicated from late formation of sulfide liquid forming complex troilite intergrowths and iron
This report is an attempt at a new method of coating the surface of the cylinder with materials that undergo chemical change at definite temperatures as indicated by a change in color. In this way it was hoped that the substance itself would indicate directly the position of its isotherms, which in measurements with thermocouples requires a tedious amount of labor.
A laser induced fluorescence technique, suitable for measuring fluctuating temperatures in cold turbulent flows containing very low concentrations of nitric oxide is described. Temperatures below 300 K may be resolved with signal to noise ratios greater than 50 to 1 using high peak power, tunable dye lasers. The method relies on the two photon excitation of selected ro-vibronic transitions. The analysis includes the effects of fluorescence quenching and shows the technique to be effective at all densities below ambient. Signal to noise ratio estimates are based on a preliminary measurement of the two photon absorptivity for a selected rotational transition in the NO gamma (0,0) band.
A laser-induced fluorescence technique based on the pulsed two-photon excitation of NO is presented which is especially suited for the measurement of fluctuating temperatures in cold turbulent flows. The technique uses the fluorescence from the UV gamma bands of NO produced by two-photon excitation of NO (A 2 Sigma +, nu-prime = 0 - X 2 Pi, nu-double prime = 0) to obtain a rotational temperature. An analysis is presented of relevant aspects of the two-photon absorption process including microphysical processes, spectral intensities as a function of transition and laser spectral widths, line-shape integrals, the nonequilibrium response of the medium to a laser pulse, fluorescence energies, signal to noise ratio, and focusing effects. An analysis of absolute two-photon absorptivity measured in a nonflowing cell is then presented and used to predict signal to noise ratios greater than 50 for supersonic flows at temperatures below 300 K.
Fusible thin film coatings used in determining aerodynamic heat transfer coefficients at hypersonic speeds
Evaluation of organic compounds for temperature indicators for subambient temperatures
Temperature profiles variability for data obtained by rocketsonde thermistors launched with small time and spatial separation
We present infrared and millimeter wavelength observations of the cold IRAS source 21391 + 5802 and its associated molecular core. Infrared observations at lambda = 3.5 microns reveal a heavily obscured, central point source which is coincident with a compact lambda = 2.7 mm continuum and C18O emission region. The source radiates about 310 solar luminosities, primarily at FIR wavelengths, suggesting that it is a young stellar object of intermediate mass. The steeply rising spectral energy distribution and the large fraction of the system mass residing in circumstellar material imply that IRAS 21391 + 5802 is in an early stage of evolution. The inferred dust temperature indicates a temperature gradient in the core. A comprehensive model for the surrounding core of dust and gas is devised to match the observed dust continuum emission and multitransition CS emission from this and previous studies. We find a r exp -1.5 +/- 0.2 density gradient consistent with that of a gravitationally evolved core and a total core mass of 380 solar masses. The observed dust emission is most consistent with a lambda exp -1.5 - lambda exp -2 dust emissivity law; for a lambda exp -2 law, the data are best fit by a mass opacity coefficient of 3.6 x 10 exp -3 sq cm/g at lambda = 1.25 mm.
Report includes specifications for the use and production of instruments used in the navigation and operation of aircraft. Specifications are included for the following instruments: barometer or altimeter, compass, air speed meter, inclinometer, drift meter, tachometer, oil gauge, oil pressure gauge, gasoline gauge, gasoline flow indicator, distance indicator, barograph, angle of attack indicator, radiator temperature indicator, gasoline feed system pressure indicator, sextant, airplane director.
In this work, a constitutive model for zircaloy-4 embedded with δ-phase hydride rim/blister structures (δ-phase zircaloy hydride) is presented. Nanoindentation and nano-scale impact experiments were performed on the δ-hydride blisters as a function of temperature in order to obtain strain rate dependent location specific constitutive response. A power law viscoplastic constitutive model was chosen to represent the strain rate dependent behavior. The strength coefficient and the strain hardening exponent in the power law relation were found to decrease with increase in temperature indicating softening behavior at higher temperatures. The strain rate exponent remained constant with increase in temperature indicating that the rate dependent ductility does not change significantly at higher temperatures. A finite element method based model was created to analyze the failure behavior and the ductile to brittle transition in zircaloy hydride. The model predicted that fracture strength of δ-phase zircaloy hydride decreases linearly with increase in temperature.
Comparisons of satellite-derived temperatures with correlative temperatures indicate that the LIMS temperatures are accurate and contain more of the needed vertical resolution for calculating a residual mean circulation for transporting tracer-like species. Generally, the LIMS temperatures are accurate to at least 2 K. Other satellite data sets are comprised of temperatures with coarser vertical resolution, leading to biases that occur with an error pattern that is characteristic of their resolution. Their biases exceed 2 K at some altitudes. Retrievals of species using an infrared limb emission technique are sensitive to any temperature bias. Generally, the IMS comparisons with other data sets for ozone and water vapor are good to better than 20 percent; this represents an independent confirmation of the quality of LIMS and temperatures. Zonal mean comparisons between LIMS and SAMS temperatures also indicate agreement to better than 2 K from about 7 to 2hPa. Therefore, we are confident that SAMS N2O and CH4 are relatively free of temperature bias in that region. These factors support the generally good agreement in G90 between model N2O transported using a LIMS-derived RMC and the N2O contours from SAMS.
The accuracy and durability of two means for measuring the metal temperature of gas-turbine blades were investigated experimentally in a turbojet engine. Cemented thermocouples that could be placed in walls as thin 0.010 inch and commercial temperature-indicating paints were evaluated at turbine-inlet temperatures up to about 1650 degrees F and for centrifugal forces equivalent to about 42,000 times gravity. The cemented thermocouples operated satisfactorily. The temperature-indicating paints were neither as accurate nor as durable as the cemented thermocouples.
Thermocouples are generally used to provide real-time temperature indications in instrumented tests performed at material and test reactors. Passive temperature monitors, such as Silicon Carbide (SiC) and melt wires, may be included in such tests as an independent technique of detecting peak temperatures experienced during irradiation. In less expensive static (drop-in) capsule tests, which have no leads attached for real-time data transmission, melt wires, and SiC temperature monitors (TMs) are essentially the only possibility for peak temperature indication. A melt wire involves placing materials (wires) of a known composition and melting temperature in a test. An inventory is maintained at Material Science Laboratory (MSL) for melt wires ranging in temperatures from 30°C to 1500°C. Unfortunately, melt wires are limited in that it can only detect whether a single temperature is or is not exceeded (melt wire melted or not). SiC TMs, which can also be used to detect peak irradiation temperatures, are advantageous because a single monitor can allow to determine the peak temperature reached within a relatively broad range (100 – 1200°C) resulting in accuracies within ±20°C. Irradiation temperature is determined by measuring a property change after isochronal annealing or during a continuously monitored annealing process using specialized equipment at MSL. Recent research has produced a passive monitor known as sublime temperature monitor. This passive sensor has the capability of recording temperature gradients and pinpointing exactly where a temperature is located along that gradient. Long measurement lengths are achieved with very high accuracy in the location of desired temperature measurements (±2 mm over a 1 m span); however, this sensor has not been deployed in a nuclear reactor. This article will focus only on passive temperature sensors currently being researched and implemented under the Advanced Sensors and Instrumentation (ASI) program at Idaho National Laboratory (INL).
An analytical investigation was made of a transient method of calibrating fine wire thermocouples. The system consisted of a 10 mil diameter standard thermocouple (Pt, Pt-13% Rh) and an 0.8 mil diameter chromel-alumel thermocouple attached to a 20 mil diameter electrically heated platinum wire. The calibration procedure consisted of electrically heating the wire to approximately 2500 F within about a seven-second period in an environment approximating atmospheric conditions at 120,000 feet. Rapid periodic readout of the standard and fine wire thermocouple signals permitted a comparison of the two temperature indications. An analysis was performed which indicated that the temperature distortion at the heater wire produced by the thermocouple junctions appears to be of negligible magnitude. Consequently, the calibration technique appears to be basically sound, although several practical changes which appear desirable are presented and discussed. Additional investigation is warranted to evaluate radiation effects and transient response characteristics.