Search NASA⌕ Search

SEARCH · Search NASA

Results for “TEMPERATURE PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Total temperature probes for high-temperature hypersonic boundary-layer measurements

The design and test results of two types of total temperature probes that were used for hypersonic boundary-layer measurements are presented. The intent of each design was to minimize the total error and to maintain minimal size for measurements in boundary layers 1.0 in. thick and less. A single platinum-20-percent-rhodium shield was used in both designs to minimize radiation heat transfer losses during exposure to the high-temperature test stream. The shield of the smaller design was flattened at the flow entrance to an interior height of 0.02 in., compared with 0.03 in. for the larger design. The resulting vent-to-inlet area ratios were 60 and 50 percent. A stainless steel structural support sleeve that was used in the larger design was excluded from the smaller design, which resulted in an outer diameter of 0.059 in., to allow closer placement of the probes to each other and to the wall. These small design changes to improve resolution did not affect probe performance. Tests were conducted at boundary-layer-edge Mach numbers of 5.0 and 6.2. The nominal free-stream total temperatures were 2600 degrees and 3200 degrees R. The probes demonstrated extremely good reliability. The best performance in terms of recovery factor occurred when the wire-based Nusselt number was at least 0.04. Recommendations for future probe designs are included.

Albertson, Cindy W.↗

Estimating Soil Thermal Inertia Profiles From the Passive Equilibration of a Temperature Probe

Knowledge of the distribution of soil thermal properties is important for understanding subsurface hydrological and biogeochemical processes. This study describes and evaluates quick thermal profiling (QTP), a new measurement technique aimed at providing rapid, depth-resolved measurements of soil thermal inertia at numerous locations across the landscape. A cylindrical probe with temperature sensors at multiple depths is quickly inserted into the ground, and soil thermal inertia is estimated from how quickly the probe temperature equilibrates with the soil. To this end, a finite volume heat transfer model is used to generate temperature equilibration time series across combinations of controlling factors, and a gridded search inversion approach is applied to infer soil thermal inertia. Field tests in the Arctic indicate that QTP measurements have a minimum uncertainty of 0.14 J m −2 K −1 s −1/2 and covary with dual-probe heat pulse thermal analyzer measurements (concordance correlation coefficient = 0.56) with a root-mean-square error of 0.40 J m −2 K −1 s −1/2 . Besides demonstrating the value of QTP for estimating thermal inertia, this study identifies various sources of measurement uncertainty, particularly probe-soil contact resistance and frictional heating. Further, analysis of soil samples indicates that thermal inertia can be used to estimate thermal conductivity and dry bulk density in the studied area, although such inferences are highly site-specific. Overall, the QTP method holds promise to generate thermal inertia data products and to complement other characterization approaches for advancing understanding of soil properties across far more locations than is currently possible.

Lamb, J. R. [Lawrence Berkeley National Laboratory↗

Thermoelectrically-cooled variable-temperature probe

Variable-temperature probe for electron spectroscopy requires no cryogenic liquids or resistance heating elements. Device consists of heat sink, probe tip, and nickel-plated copper body which resists oxidation and transfers heat efficiently between tip and heat sink.

Kelso, R. M.↗

Pioneer Venus Orbiter Electron Temperature Probe

The Orbiter Electron Temperature Probe (OETP) instrumentation and measurement technique has been designed to perform in-situ measurements of electron temperature and electron and ion density in the ionosphere of Venus. Adaptive sweep voltage circuitry continuously tracks the changing electron temperature and spacecraft potential while auto-ranging electrometers adjust their gain in response to the changing plasma density. Control signals used in the instrument to achieve this automatic tracking provide a continuous monitor of the ionospheric parameters without telemetering each volt-ampere curve. Internal data storage permits high data rate sampling of selected raw characteristic curves for low rate transmission to earth. These curves are used to verify or correct the inflight processed data. Sample in orbit measurements are presented to demonstrate instrument performance.

Krehbiel, J. P.↗

Flight-test results from two total temperature probes for air-data measurements up to 2014 K (3625 R)

An experimental temperature probe package containing a fluidic oscillator temperature probe and a shielded thermocouple temperature probe was tested during several X-15 flights. The X-15 flights provided greatly varying test conditions, including a wide range of rapidly changing total temperatures and Mach numbers which extended from subsonic to hypersonic speeds. Within restricted ranges of free-stream Mach number, free-stream unit weight flow, and local stagnation pressure, both probes yielded ramp outputs of temperature parallel to ramp inputs of free-stream total temperature. Within these ranges both probes were used to determine total temperature in the Mach 6 temperature environment. Because ambient temperature was known, both probes were used to estimate velocity and Mach number.

Nugent, J.↗

Displacement Compensation of Temperature Probe Data

Analysis of temperature data from a probe in a vertical Bridgman furnace growing germanium crystals revealed a displacement of the temperature profile due to conduction error. A theoretical analysis shows that the displacement compensation is independent of local temperature gradient. A displacement compensation value should become a standard characteristic of temperature probes used for temperature profile measurements.

Welch, Christopher S.↗

Water-Cooled Total-Temperature Probe

Water-cooled supersonic total-pressure, static-pressure, and total-temperature probes developed to study high-temperature jet plumes. Total-temperature probe tested up to 2,000 degrees F incorporates annular cooling system up to thermocouple lead. Lead extends into test chamber to sense temperature of supersonic external flow. Design novel and significant. Applicable in development of jet engines and in research on fast flows of hot gases.

Lagen, Nicholas T.↗

Electron temperatures and densities in the Venus ionosphere - Pioneer Venus orbiter electron temperature probe results

The Pioneer Venus orbiter electron temperature probe was used to obtain altitude profiles of electron temperature and density in the ionosphere of Venus. Elevated temperatures at times of low solar wind flux might indicate support for a certain model. According to this model, less than 5% of the solar wind energy is deposited at the ionopause and is conducted downward through an unmagnetized ionosphere to the region below 200 km where electron cooling to the neutral atmosphere proceeds rapidly. The patterns of electron temperatures and densities at higher solar wind fluxes are considered, the variability of the ionopause height in the late afternoon is noted, and the role of an induced magnetic barrier in the neighborhood of the ionopause is discussed.

Brace, L. H.↗

Correction analysis for a supersonic water cooled total temperature probe tested to 1370 K

The authors address the thermal analysis of a water cooled supersonic total temperature probe tested in a Mach 2 flow, up to 1366 K total temperature. The goal of this experiment was the determination of high-temperature supersonic jet mean flow temperatures. An 8.99 cm exit diameter water cooled nozzle was used in the tests. It was designed for exit Mach 2 at 1366 K exit total temperature. Data along the jet centerline were obtained for total temperatures of 755 K, 1089 K, and 1366 K. The data from the total temperature probe were affected by the water coolant. The probe was tested through a range of temperatures between 755 K and 1366 K with and without the cooling system turned on. The results were used to develop a relationship between the indicated thermocouple bead temperature and the freestream total temperature. The analysis and calculated temperatures are presented.

Lagen, Nicholas T.↗

High-Temperature Probe Station Developed to Characterize Microwave Devices Through 500 C

A photograph and a block diagram of the high-temperature probe station are shown. The system consists of the ceramic heater mounted on a NASA shuttle tile insulator, a direct current power supply, a personal-computer-based data acquisition and temperature controller, microwave probes, a microscope, and a network analyzer. The ability to perform microwave tests at high temperatures is becoming necessary. There is now a need for sensors and communication circuits that can operate at 500 C and above for aircraft engine development and monitoring during flight. To address this need, researchers have fabricated devices using wide bandgap semiconductors such as SiC with targeted operating temperatures of 500 to 600 C. However, the microwave properties of these devices often change drastically with temperature, so any designs that are intended to be used in such an environment must be characterized at high temperatures. For some reliability, lifetime, and direct-current testing, the device under test can be packaged and characterized in an oven. However, for RF and microwave measurements, it is usually not possible to establish a calibrated reference plane at the device terminals within a package. In addition, the characteristics of the package would vary over a 500 C temperature range, and this would have to be accounted for when the data were analyzed. A high temperature probe station allows circuits and devices to be characterized through on wafer measurements across a broad temperature range with known reference plane. The conventional, commercially available thermal wafer-probe stations that are used to evaluate microwave devices across a controlled temperature range have a typical upper limit of 200 C. Standalone thermal heating chucks are available with an extended upper temperature range of 300 to 400 C. To effectively characterize devices at temperatures up to and surpassing 500 C, Glenn researchers developed a custom probe station. In the past, custom probe stations have been developed to test devices under other extreme environments, such as cryogenic temperatures as low as 37 K. Similarly, this custom probe station was specifically modified for high-temperature use. It allows devices to be measured quickly and flexibly, without the use of wire bonds and test fixtures. The probe station is shown making scattering parameter measurements from 1 to 50 GHz with a Hewlett-Packard 8510C Network Analyzer. There is a half-wafer of silicon directly on top of the heater to provide a uniform heated platform for our sample. A quarter wafer of silicon carbide forms the substrate for our test circuit of several transmission lines.

Downey, Alan N.↗

Pioneer Venus orbiter electron temperature probe

This document lists the scientific accomplishments of the Orbiter Electron Temperature Probe (OETP) group. The OETP instrument was fabricated in 1976, integrated into the PVO spacecraft in 1977, and placed in orbit about Venus in December 1978. The instrument operated flawlessly for nearly 14 years until PVO was lost as it entered the Venusian atmosphere in October 1992. The OETP group worked closely with other PVO investigators to examine the Venus ionosphere and its interactions with the solar wind. After the mission was completed we continued to work with the scientist selected for the Venus Data Analysis Program (VDAP), and this is currently leading to additional publications.

Brace, Larry H.↗

Design and construction of a low-velocity boundary-layer temperature probe

This paper presents the results of a study performed to determine the probe geometry and thermal characteristics for a low-velocity boundary-layer temperature probe capable of eliminating conduction errors. Design curves for four common thermoelectric pairs are presented, and an experimental turbulent boundary-layer temperature profile is compared with the theoretical laminar sublayer equation to verify that the probe eliminates conduction errors.

Blackwell, B. F.↗

Methyl acetylene as a temperature probe for dense interstellar clouds

Methyl acetylene (propyne) appears to be a convenient and reliable probe of kinetic temperature for dense (few x 10 to the 4th/ cu cm) molecular clouds. A method is presented for fitting a (J + 1) - J K-multiplet to obtain the kinetic temperature from a single observation, facilitating the direct construction of kinetic temperature maps. Observations of Tau MC1, Ori MC1, Sgr B2, DR 21, DR 21 (OH), and S140 are presented to demonstrate the validity of the technique. Determination of methyl acetylene column densities requires, in addition, knowledge of the rotational excitation temperature. The relative abundance of CH3CCH appears to be within a factor of 2 of 2.5 x 10 to the -9th. Because of the large uncertainties in estimates of total gas column density, it is not clear whether there is genuine source-to-source variation in the CH3CCH relative abundance.

Kuiper, T. B. H.↗