Search NASA⌕ Search

SEARCH · Search NASA

Results for “TENSILE STRESS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A silicon microwire under a three-dimensional anisotropic tensile stress

Three-dimensional tensile stress, or triaxial tensile stress, is difficult to achieve in a material. We present the investigation of an unusual three-dimensional anisotropic tensile stress field and its influence on the electronic properties of a single crystal silicon microwire. The microwire was created by laser heating an amorphous silicon wire deposited in a 1.7 μm silica glass capillary by high pressure chemical vapor deposition. Tensile strain arises due to the thermal expansion mismatch between silicon and silica. Synchrotron X-ray micro-beam Laue diffraction (μ-Laue) microscopy reveals that the three principal strain components are +0.47% (corresponding to a tensile stress of +0.7 GPa) along the fiber axis and nearly isotropic +0.02% (corresponding to a tensile stress of +0.3 GPa) in the cross-sectional plane. This effect was accompanied with a reduction of 30 meV in the band gap energy of silicon, as predicted by the density-functional theory calculations and in close agreement with energy-dependent photoconductivity measurements. While silicon has been explored under many stress states, this study explores a stress state where all three principal stress components are tensile. Given the technological importance of silicon, the influence of such an unusual stress state on its electronic properties is of fundamental interest.

36 MATERIALS SCIENCE↗

Tensile-stress effect on ferroelectric Barkhausen noise

Here, this study examines the effect of tensile stress on the ferroelectric properties of Pb(Zr 0.4 Ti 0.6 )O 3 thin film, with a focus on Barkhausen noise, observed for the first time under such conditions. Tensile stress significantly alters domain wall motions, affecting Barkhausen noise more than average polarization. Frequency analysis identifies grain boundaries as primary pinning sites, consistent across stress levels. A nonlinear relationship between stress, domain wall mobility, and polarization is found, where increased stress initially enhances pinning and polarization changes, but this effect diminishes at higher stress levels, indicating a shift in behavior.

36 MATERIALS SCIENCE↗

Improved experimental and diagnostic techniques for dynamic tensile stress–strain measurement with a Kolsky tension bar

Kolsky tension bar experiments were improved for dynamic tensile stress–strain measurements with higher fidelity and minimal uncertainties. The difficulties associated with specimen gripping, relatively short gage section, and geometric discontinuity at the bar ends all compromise the accuracy of the traditional strain measurement method in a Kolsky tension bar experiment. Here in this study, an improved three-channel splitting-beam laser extensometer technique was developed to directly and independently track the displacement of the incident and transmission bar interfaces. By adopting a dual-channel configuration on the incident bar side, the resolution and measurement range of this laser extensometer were coordinated between the two channels to provide highly precise measurement at both small and large strains under high strain-rate loading condition. On the transmission bar side an amplified channel, similar to that used on the incident bar side, was adopted to measure the transmission bar displacement with high resolution. With this novel design, a maximum resolution of approximately 500 nm can be obtained for the bar displacement measurement, which corresponds to a strain of 0.0079% for a specimen with 6.35 mm gage length. To further improve the accuracy, a pair of lock nuts were used to tighten the tensile specimen to the bars in an effort not only to prevent the specimen from potential pre-torsional deformation and damage during installation, but also to provide better thread engagement between the specimen and the bar ends. As a demonstration of this technique, dynamic tensile stress–strain response of a 304L stainless steel was characterized with high resolution in both elastic and plastic deformations.

42 ENGINEERING↗

Role of Tensile Stress in DNA Nanoresonators for Epigenetic Studies

The evaluation of epigenetic features such as DNA methylation is becoming increasingly important in many biochemical processes like gene expression and transcription as well as in several diseases like schizophrenia or diabetes. Here, in this work, we report that self-assembled nanomechanical resonators entirely composed of DNA molecules can be used to explore gross changes in DNA methylation levels (0–25–50%), while careful control of tensile stress is needed to reduce the variability of resonance frequency for rigorous quantification. The effect of the tensile stress retained by the suspended DNA nanoresonators on the application of the technique is extensively explored using a combination of laser Doppler vibrometry and atomic force spectroscopy. DNA nanoresonators are real-time, label-free sensors and could avoid chemical functionalization and sample amplification. Therefore, they may represent in the future a key complementary routine tool for global DNA methylation analysis needed to evaluate the consequences of environmental stresses on the human genome.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tensile stress effect on epitaxial BiFeO 3 thin film grown on KTaO 3

Comprehensive crystal structural study is performed for BiFeO 3 (BFO) film grown on KTaO 3 (KTO) substrate using transmission electron microscopy (TEM) and x-ray diffraction (XRD). Nano beam electron diffraction (NBED) combined with structure factor calculation and high resolution TEM images clearly reveal that the crystal structure within BFO thin film is rhombohedral BFO, i.e., bulk BFO phase. Epitaxial relationship found by NBED indicates the BFO film grows in a manner that minimizes lattice mismatch with KTO. It further suggests BFO film is under slight biaxial tensile stress (~0.35%) along in-plane direction. XRD reveals BFO lattice is under compressive stress (~1.6%), along out-of-plane direction as a result of the biaxial tensile stress applied along in-plane direction. This leads to Poisson’s ratio of ~0.68. In addition, we demonstrate (1) why hexagonal notation rather than pseudocubic one is required for accurate BFO phase evaluation and (2) a new XRD method that shows how rhombohedral BFO can readily be identified among other phases by measuring a rhombohedral specific Bragg’s peak.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Relating Hydro–Mechanical and Elastodynamic Properties of Dynamically Stressed Tensile–Fractured Rock in Relation to Applied Normal Stress, Fracture Aperture, and Contact Area

We exploit nonlinear elastodynamic properties of fractured rock to probe the micro-scale mechanics of fractures and understand the relation between fluid transport and fracture aperture under dynamic stressing. Experiments were conducted on rough, tensile-fractured Westerly granite subject to triaxial stresses. We measure fracture permeability for steady-state fluid flow with deionized water. Pore pressure oscillations are applied at amplitudes ranging from 0.2 to 1 MPa at 1 Hz frequency. During dynamic stressing we transmit ultrasonic signals through the fracture using an array of piezoelectric transducers (PZTs) to monitor evolution of interface properties. We examine the influence of fracture aperture and contact area by conducting measurements at effective normal stresses of 10–20 MPa. Additionally, the evolution of contact area with stress is characterized using pressure sensitive film. These experiments are conducted separately with the same fracture and map contact area at stresses from 9 to 21 MPa. The measurements are a proxy for “true” contact area for the fracture surface and we relate them to elastic properties using the calculated PZT sensor footprints via numerical modeling of Fresnel zones. We compare the elastodynamic response of the fracture using the stress-induced changes in ultrasonic wave velocities for transmitter-receiver pairs to image spatial variations in contact properties. We show that nonlinear elasticity and permeability enhancement decrease with increasing normal stress. Additionally, post-oscillation wave velocity and permeability exhibit quick recoveries toward pre-oscillation values. Estimates of fracture contact area (global and local) demonstrate that the elastodynamic and permeability responses are dominated by fracture topology.

58 GEOSCIENCES↗

Identification of Post-necking Tensile Stress–Strain Behavior of Steel Sheet: An Experimental Investigation Using Digital Image Correlation Technique

The stress–strain behavior of sheet metal is commonly evaluated by tensile test. However, the true stress–strain curve is restricted up to uniform elongation of the material. Usually, after the uniform elongation of the material the true stress–strain is obtained by extrapolation. The present work demonstrates a procedure to find out the true tensile stress–strain curve of the steel sheet after necking using digital image correlation (DIC) technique. Hill’s normal anisotropic yield criteria and local strains measured by DIC technique are used to correct the local stress and strain states at the diffuse necked area. The proposed procedure is shown to successfully determine the true tensile stress–strain curve of ferritic and dual-phase steel sheets after necking/uniform elongation.

36 MATERIALS SCIENCE↗

FEM Modeling of In-Plane Stress Distribution in Thick Brittle Coatings/Films on Ductile Substrates Subjected to Tensile Stress to Determine Interfacial Strength

The ceramic-metal interface is present in various material structures and devices that are vulnerable to failures, like cracking, which are typically due to their incompatible properties, e.g., thermal expansion mismatch. In failure of these multilayer systems, interfacial shear strength is a good measure of the robustness of interfaces, especially for planar films. There is a widely-used shear lag model and method by Agrawal and Raj to analyse and measure the interfacial shear strength of thin brittle film on ductile substrates. The use of this classical model for a type of polymer derived ceramic coatings (thickness ~18 μm) on steel substrate leads to high values of interfacial shear strength. Here, we present finite element simulations for such a coating system when it is subjected to in-plane tension. Results show that the in-plane stresses in the coating are non-uniform, i.e., varying across the thickness of the film. Therefore, they do not meet one of the basic assumptions of the classical model: uniform in-plane stress. Furthermore, effects of three significant parameters, film thickness, crack spacing, and Young’s modulus, on the in-plane stress distribution have also been investigated. ‘Thickness-averaged In-plane Stress’ (TIS), a new failure criterion, is proposed for estimating the interfacial shear strength, which leads to a more realistic estimation of the tensile strength and interfacial shear strength of thick brittle films/coatings on ductile substrates.

36 MATERIALS SCIENCE↗

Capillary flow in UHPFRC with synthetic fibers, under high tensile stresses

A novel Ultra High-Performance Fiber Reinforced Concrete (UHPFRC) mix with synthetic fibers and a low clinker matrix, henceforth referred to as PE-UHPFRC, has been developed for structural applications. It exhibits a high tensile elastic limit above 7 MPa, a tensile strength of more than 10 MPa, and a very high tensile hardening domain of above 3.5%. In order to effectively use this material, its protective properties have been investigated on the basis of the effect of tensile deformation and subsequent cracking on water transport properties, for a wide range of tensile strain. A special setup was developed to measure the capillary absorption of liquids while the specimen is under tension. The results show a considerable reduction in capillary absorption in case of PE-UHPFRC compared with Strain Hardening Cement-based Composites (SHCC). Moreover, the results highlight the considerable effect of the onset of cracking on capillary absorption.

36 MATERIALS SCIENCE↗

Dynamic fracture of tantalum under extreme tensile stress

The understanding of fracture phenomena of a material at extremely high strain rates is a key issue for a wide variety of scientific research ranging from applied science and technological developments to fundamental science such as laser-matter interaction and geology. Despite its interest, its study relies on a fine multiscale description, in between the atomic scale and macroscopic processes, so far only achievable by large-scale atomic simulations. Direct ultrafast real-time monitoring of dynamic fracture (spallation) at the atomic lattice scale with picosecond time resolution was beyond the reach of experimental techniques. We show that the coupling between a high-power optical laser pump pulse and a femtosecond x-ray probe pulse generated by an x-ray free electron laser allows detection of the lattice dynamics in a tantalum foil at an ultrahigh strain rate of Embedded Image ~2 × 10 8 to 3.5 × 10 8 s -1 . A maximal density drop of 8 to 10%, associated with the onset of spallation at a spall strength of ~17 GPa, was directly measured using x-ray diffraction. The experimental results of density evolution agree well with large-scale atomistic simulations of shock wave propagation and fracture of the sample. Our experimental technique opens a new pathway to the investigation of ultrahigh strain-rate phenomena in materials at the atomic scale, including high-speed crack dynamics and stress-induced solid-solid phase transitions.

36 MATERIALS SCIENCE↗

Finite Element Analysis (FEA) for Water-Foam Fracturing of Granite Rock

In addition to the foam data that were obtained from literature and that were collected from the current study, simulation data was also generated from finite element analysis (FEA) conducted in this study using COMSOL Multiphysics software. The FEA models were built to simulate the experiments conducted at Oak Ridge National Laboratory (ORNL) on cement and granite samples. In these FEA models, temperature was kept at ambient while the pressure profile resembled the loading conditions during the ORNL experiments, where pressure was either monotonically increased or applied cyclically. The cement material was used as a model material and was used to study Von Mises stress and tensile stress distribution for different bore hole length geometry using a parametric sweep with water as fracturing fluid using solid-fluid interaction module. For the granite material, FEA models were developed for stress analysis of cylindrical samples with water or foam fluids. The solid mechanics module in COMSOL was implemented to solve for Von Mises stress and tensile stress. The fluid-structure interaction module was implemented to solve for water-foam interaction on granite cylinder with addition of fluid-loading on structure, i.e., large deformation in solid mechanics with no impact on fluid deformation. Foam was considered as a pseudo single-phase compressible fluid for which material properties were calculated from water and gas (nitrogen) phases. The density of foam is calculated as a function of the densities of water and nitrogen, while viscosity is a function of temperature. Four types of FEA analyses were modelled: 1. Monotonic injection with water 2. Monotonic injection with foam 3. Cyclic injection with water 4. Cyclic injection with foam All the COMSOL files are converted to a zip file which is save in .mph.

15 GEOTHERMAL ENERGY↗

Hoop Tensile Failure Stress of 500 µm-Diameter Ceramic Spheres

The tensile failure stress of a brittle-material sphere is important to the survival of the sphere itself but is particularly relevant to systems that employ such spheres for applications in which the sphere exterior is subjected to tension during system fabrication or operation. That maximum hoop or tangential stress can be measured by diametrally compressing a C-sphere specimen directly machined from such spheres. This combination of specimen geometry and test method was conceived at Oak Ridge National Laboratory around 20 years ago. Although the C-sphere geometry has been tested with larger spheres, the ease and efficacy of its testing are unknown for submillimeter sphere diameters. To consider this, C-sphere specimens were machined from yttria-stabilized zirconia (YSZ) spheres of ∼500 µm diameter. The maximum (hoop or tangential) tensile stress was determined as a function of compressive failure force and specimen dimensions using finite element analysis. Companion effective area and volume as a function of Weibull modulus were computed. Hoop tensile failure stresses were then measured and fractography conducted to examine flaw type and location and to estimate the mirror constant of this YSZ grade. This novel study demonstrates that hoop tensile failure stress can be determined with sub-millimeter brittle-material spheres.

Delia, Daniel [ORNL] (ORCID:0000000209023239)↗

Assessment of InSb infrared detector arrays assembly procedure employing ANSYS

Local failure in the InSb infrared detector arrays (InSb IDAs) is chiefly triggered by the local shear stress, the peeling stress, and the tensile stress in the InSb IDAs. Thus, these three stress components are utilized to assess the rationality of the current assembly procedure of the InSb IDAs in this paper, which is described as follows: firstly, performing liquid nitrogen shocking tests on the fabricated InSb IDAs, provided that no local failure phenomena occur in the InSb IDAs, then the balanced composite structure (BCS) is glued with the bottom surface of the InSb IDAs to accomplish the fabrication of the InSb IDAs assembly. We ascertain that the tensile stress in the center region of the InSb substrate declines slightly with the attached BCS, at the same time, both the interfacial shear stress and the peeling stress maintain unchanged at the locations where the local delamination most likely appears. These non-increased stress distribution characteristics with the added BCS confirmed that the current assembly procedure of the InSb IDAs is reasonable, and the glued BCS does not increase the failure probability of the InSb IDAs assembly.

36 MATERIALS SCIENCE↗

Evolution of Microstructure, Residual Stress, and Tensile Properties of Additively Manufactured Stainless Steel Under Heat Treatments

This study investigated the microstructure, residual stress and tensile properties of the directed energy deposited stainless steel 316L (SS316L) under thermal annealing. Microstructure characterization shows the as-printed sample has laser-generated patterns where dendritic structure is observed at the edge of the patterns and cellular structure dominates the interior region. Here, the thermal annealing at 983 and 1093°C effectively removes the dendritic/cellular structures. Synchrotron X-ray diffraction reveals that the as-fabricated SS316L exhibits compressive residual stress of -197.4 MPa. The stress is greatly relieved to -53.8 MPa after annealing at 1093°C. The room temperature tensile testing indicates that the yield strength and ultimate tensile strength drop from 378 and 502 MPa in the as-printed sample to 258 and 446 MPa in the annealed samples (1093°C), respectively. Our study provides insights into the relationship between microstructure, residual stress, and tensile properties of laser additive manufactured SS316L.

36 MATERIALS SCIENCE↗