Search NASA⌕ Search

SEARCH · Search NASA

Results for “TESLA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

SU-F-J-166: Volumetric Spatial Distortions Comparison for 1.5 Tesla Versus 3 Tesla MRI for Gamma Knife Radiosurgery Scans Using Frame Marker Fusion and Co-Registration Modes

Purpose: To compare typical volumetric spatial distortions for 1.5 Tesla versus 3 Tesla MRI Gamma Knife radiosurgery scans in the frame marker fusion and co-registration frame-less modes. Methods: Quasar phantom by Modus Medical Devices Inc. with GRID image distortion software was used for measurements of volumetric distortions. 3D volumetric T1 weighted scans of the phantom were produced on 1.5 T Avanto and 3 T Skyra MRI Siemens scanners. The analysis was done two ways: for scans with localizer markers from the Leksell frame and relatively to the phantom only (simulated co-registration technique). The phantom grid contained a total of 2002 vertices or control points that were used in the assessment of volumetric geometric distortion for all scans. Results: Volumetric mean absolute spatial deviations relatively to the frame localizer markers for 1.5 and 3 Tesla machine were: 1.39 ± 0.15 and 1.63 ± 0.28 mm with max errors of 1.86 and 2.65 mm correspondingly. Mean 2D errors from the Gamma Plan were 0.3 and 1.0 mm. For simulated co-registration technique the volumetric mean absolute spatial deviations relatively to the phantom for 1.5 and 3 Tesla machine were: 0.36 ± 0.08 and 0.62 ± 0.13 mm with max errors of 0.57 and 1.22 mm correspondingly. Conclusion: Volumetric spatial distortions are lower for 1.5 Tesla versus 3 Tesla MRI machines localized with markers on frames and significantly lower for co-registration techniques with no frame localization. The results show the advantage of using co-registration technique for minimizing MRI volumetric spatial distortions which can be especially important for steep dose gradient fields typically used in Gamma Knife radiosurgery. Consultant for Elekta AB.

60 APPLIED LIFE SCIENCES↗

TESLA's High Gradient March: Thirty years anniversary of TESLA Technology Collaboration (TTC)

In 2020, the TTC (TESLA Technology Collaboration) celebrates 30 years of collaborative efforts on SRF technologies. The first international TESLA workshop on a TeV Energy Superconducting Linear Accelerator was held at Cornell University on July 23-26, 1990. The purpose of the meeting was to work on a parameter list for a superconducting high energy physics collider in the Teravolt energy region and to explore ideas on how to increase the gradients and lower the costs for the accelerator structures. It was clear from the beginning that the needed technological progress would require a large international collaboration. This meeting was indeed the origin of a long preparation effort toward a future ILC (International Linear Collider), which eventually led to the realization of the TTF (TESLA Test Facility, since 2005 operated as the DESY user facility FLASH) and the European XFEL also at DESY, and created the conditions supporting the proposals for several large SRF-based research facilities like SNS, LCLS-II, ESS, PIP-II and SHINE, as well as a growing number of smaller facilities around the world. Highlights of this 30-year international collaboration are presented and celebrated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tesla Valve Integration into Propulsion Systems for Water Hammer Mitigation

Water hammer is a pressure surge or wave caused when a liquid in motion is forced to stop or change direction suddenly. Satellite and in-space propulsion systems exhibit this effect when valves, which can pulse several times per second, close quickly to isolate propellant from thrusters. The inherent nature of pulsing thrusters quickly has made water hammer a constant design challenge for these systems. Historically, the standard is to accept that the Maximum Design Pressure (MDP) of the system must account for a full worst case water-hammer event, which can be several times the Maximum Expected Operating Pressure (MEOP). An investigation is being conducted to determine the effectiveness of tesla valves in reducing water hammer amplitudes. Tesla Valves can be used in-line within propulsion systems to allow unrestricted flow in one direction and restricted flow in the opposite direction without the use of added mechanical or electrical components. Tesla valves use fixed internal geometry to allow for this unrestricted and restricted flow. With the increase and capability of Additive Manufacturing (AM), different configurations and concepts of tesla valves can be manufactured and tested at minimal cost. This concept could possibly be used to allow for a less complicated, or robust satellite and in-space propulsion system. This presentation will cover topics of additive manufactured design of tesla valves, testing, and variables to consider within tesla valve creation.

Michael A Willis↗

Edison vs. Tesla

As Edison vs. Tesla week heats up at the Energy Department, we are exploring the rivalry between Thomas Edison and Nikola Tesla and how their work is still impacting the way we use energy today. Whether you're on Team Tesla or Team Edison, both inventors were key players in creating things like batteries, power plants and wireless technologies -- all innovations we still use today. And as we move toward a clean energy future, energy efficient lighting, like LED bulbs, and more efficient electric motors not only help us save money on electricity costs but help combat climate change. For this, Tesla and Edison both deserve our recognition.

99 GENERAL AND MISCELLANEOUS↗

Comparative analysis of thermal management systems in electric vehicles at extreme weather conditions: Case study on Nissan Leaf 2019 Plus, Chevrolet Bolt 2020 and Tesla Model 3 2020

With the surge in electric vehicle (EV) adoption and the need for extended driving ranges, optimizing energy efficiency, particularly through thermal management, is critical, especially in extreme weather. Managing the substantial energy needed for cabin climate control and battery temperature regulation can increase energy demands by over 50 %, severely limiting range. This study conducts a comparative analysis of thermal management systems (TMS) in three popular EV vehicles, 2020 Chevrolet Bolt, 2019 Nissan Leaf Plus, and 2020 Tesla Model 3, evaluating their distinct TMS configurations and performance under varied weather conditions. Using both numerical simulations and experimental data collected on a controlled test bench at Argonne National Laboratory, we assess how TMS architecture and operational modes influence energy consumption and range. A comprehensive TMS model was developed, integrating cabin and battery thermal sub-models in the Autonomie software platform, to simulate temperature fluctuations and range impacts. Cabin climate was modeled using a mono-zonal approach, while battery cell temperature distribution was estimated through a 2D nodal structure. Each vehicle's distinct TMS setup was evaluated: the Chevrolet Bolt and Tesla Model 3 use a dual evaporator vapor compression cycle with a PTC heater for the cabin and a coolant loop for battery thermal management; the Nissan Leaf Plus employs a heat pump with a PTC heater for the cabin and air-cooling for the battery. Tests conducted at ambient temperatures of 35°C, 22°C, -7°C, and -18°C reveal significant differences in energy use and range reduction across both configurations and conditions. At 35°C, the Tesla Model 3, Chevrolet Bolt, and Nissan Leaf Plus have a range reduction of 8%, 9%, and 13%, respectively, due to air conditioning. In winter, heating technology is paramount; at -7°C, the Nissan Leaf's heat pump configuration achieves a lower range reduction (19.3%) compared to the Tesla and Chevrolet Bolt PTC heaters, which reduce range by 28.3% and 31%, respectively. Further, this study provides valuable insights for automotive engineers, EV technology researchers, and thermal management system designers aiming to enhance electric vehicle performance by understanding how different weather conditions and TMS architectures impact energy consumption and driving range.

33 ADVANCED PROPULSION SYSTEMS↗

Evaluation of Artifacts and Distortions of Titanium Applicators on 3.0-Tesla MRI: Feasibility of Titanium Applicators in MRI-Guided Brachytherapy for Gynecological Cancer

Purpose: The aim of this study was to characterize the levels of artifacts and distortions of titanium applicators on 3.0-Tesla magnetic resonance imaging (MRI). Methods and Materials: Fletcher-Suit-Delclos-style tandem and ovoids (T and O) and tandem and ring applicator (T and R) were examined. The quality assurance (QA) phantoms for each applicator were designed and filled with copper sulphate solution (1.5 g/l). The artifacts were quantified with the registration of corresponding computed tomography (CT) images. A favorable MR sequence was searched in terms of artifacts. Using the sequence, the artifacts were determined. The geometric distortions induced by the applicators were quantified through each registration of CT and MRI without applicators. The artifacts of T and O were also evaluated on in vivo MRI datasets of 5 patients. Results: T1-weighted MRI with 1-mm slice thickness was found as a favorable MR sequence. Applying the sequence, the artifacts at the tandem tip of T and O and T and R were determined as 1.5 {+-} 0.5 mm in a superior direction in phantom studies. In the ovoids of T and O, we found artifacts less than 1.5 {+-} 0.5 mm. The artifacts of a T and O tandem in vivo were found as less than 2.6 {+-} 1.3 mm on T1-weighted MRI, whereas less than 6.9 {+-} 3.4 mm on T2-weighted MRI. No more than 1.2 {+-} 0.6 mm (3.0 {+-} 1.5 mm) of distortions, due to a titanium applicator, were measured on T1-weighted MRI (T2-). Conclusion: In 3.0-Tesla MRI, we found the artifact widths at the tip of tandem were less than 1.5 {+-} 0.5 mm for both T and O and T and R when using T1-weighted MRI in phantom studies. However, exclusive 3.0-Tesla MRI-guided brachytherapy planning with a titanium applicator should be cautiously implemented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An 8-GW long-pulse generator based on Tesla transformer and pulse forming network

A long-pulse generator TPG700L based on a Tesla transformer and a series pulse forming network (PFN) is constructed to generate intense electron beams for the purpose of high power microwave (HPM) generation. The TPG700L mainly consists of a 12-stage PFN, a built-in Tesla transformer in a pulse forming line, a three-electrode gas switch, a transmission line with a trigger, and a load. The Tesla transformer and the compact PFN are the key technologies for the development of the TPG700L. This generator can output electrical pulses with a width as long as 200 ns at a level of 8 GW and a repetition rate of 50 Hz. When used to drive a relative backward wave oscillator for HPM generation, the electrical pulse width is about 100 ns on a voltage level of 520 kV. Factors affecting the pulse waveform of the TPG700L are also discussed. At present, the TPG700L performs well for long-pulse HPM generation in our laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Liquid neon heat transfer as applied to a 30 tesla cryomagnet

Since superconducting magnets cooled by liquid helium are limited to magnetic fields of about 18 teslas, the design of a 30 tesla cryomagnet necessitates forced convection liquid neon heat transfer in small coolant channels. As these channels are too small to handle the vapor flow if the coolant were to boil, the design philosophy calls for suppressing boiling by subjecting the fluid to high pressures. Forced convection heat transfer data are obtained by using a blowdown technique to force the fluid vertically through a resistance-heated instrumented tube. The data are obtained at inlet temperatures between 28 and 34 K and system pressures between 28 to 29 bars. Data correlation is limited to a very narrow range of test conditions, since the tests were designed to simulate the heat transfer characteristics in the coolant channels of the 30 tesla cryomagnet concerned. The results can therefore be applied directly to the design of the magnet system.-

Papell, S. S.↗

MR elastography of liver at 3 Tesla: comparison of gradient-recalled echo (GRE) and spin-echo (SE) echo-planar imaging (EPI) sequences and agreement across stiffness measurements

Purpose: To compare 2D gradient-recalled echo (GRE) and 2D spin-echo (SE) echo-planar imaging (EPI) MR elastography (MRE) for measurement of hepatic stiffness in adult patients with known or suspected liver disease at 3 Tesla. Materials and methods: Three hundred and eighty-seven consecutive patients underwent MRE of the liver at 3 Tesla with 2D-GRE and 2D-SE-EPI sequences. ‘Mean liver stiffness (LS)’ calculated by averaging 3 ROIs in the right lobe, ‘Maximum LS’ calculated by an ROI in the right lobe; and ‘Freehand LS’ calculated by an ROI in the entire liver were measured by two independent readers. Inter-observer and inter-class variability in stiffness measurements were assessed. Stiffness values were correlated with degree of liver fibrosis (METAVIR scores) in 97 patients who underwent biopsy. The diagnostic performance was compared by a receiver-operating characteristic analysis. Results: The technical failure rate was 2.8% for 2D-SE-EPI (11/387) and 4.1% for 2D-GRE (16/387, 9 had R{sub 2}* > 80 s{sup −1} indicating iron overload). There is high reproducibility for both GRE and SE-EPI variants (ICC = 0.84–0.94 for both GRE and SE-EPI MRE). The highest sensitivity, specificity, and accuracy of differentiating mild fibrosis (F0–F2) from advanced fibrosis (F3–F4) are 0.84 (GRE Freehand measurement), 0.92 (GRE Maximum stiffness measurement), and 0.88 (GRE Freehand measurement), respectively. Conclusions: High intra-class correlation and intra-reader correlation are seen on measured hepatic stiffness for both 2D-GRE and 2D-SE-EPI MRE. 2D-SE-EPI has lower failure rate. Diagnostic performance of both sequences is equivalent, with highest sensitivity for 2D-GRE Freehand stiffness measurement, and highest specificity 2D-GRE Maximum stiffness measurement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A six-channel pediatric coil array for detection of children spinal pathologies by MRI at 1.5 Tesla

Nowadays, magnetic resonance (MR) in Mexico has become a standard technique for clinical imaging. Although most of the times the MR systems contain only coils oriented for adults. Radiologists use these coils for children studies due to the non-availability of pediatric coils. Image quality is decreased due to the low signal to noise ratio delivered to the system. The development of RF coils is always focused towards increasing SNR and optimizing the RF penetration into the sample. Moreover, spinal pathologies in children, which are an important topic in pediatric care, cover congenital and neuromuscular disorders that occur in childhood. In this work, the design of a dedicated six-channel coil for detection of spinal pathologies at 1.5 Tesla is addressed. Numerical electromagnetic simulations were performed in order to evaluate their magnetic field performance at (63.6 MHz) 1.5 Tesla. The magnetic field uniformity as well as the RF penetration depth of the coil configurations was evaluated in order to find the best/optimized coil array configuration. The coil is comprised of three rows, one with 4 coil elements and two with only one coil element. Phantom and in vivo images were acquired with the six-channel pediatric coil array. The phantom images agree with the simulated data. In vivo images acquired with the 6-channel pediatric coil array have shown very good penetration depth and homogeneity, which allow better image quality throughout the whole FOV. In addition, the parallel imaging capabilities of the array allow the acceleration of the experiments avoiding possible motion artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Operation of normal-conducting rf cavities in multi-Tesla magnetic fields for muon ionization cooling: A feasibility demonstration

Ionization cooling is the preferred method for producing bright muon beams. This cooling technique requires the operation of normal conducting, radio-frequency (rf) accelerating cavities within the multi-tesla fields of dc solenoid magnets. Under these conditions, cavities exhibit increased susceptibility to rf breakdown, which can damage cooling channel components and imposes limits on channel length and transmission efficiency. We report, for the first time, stable high-vacuum, normal-conducting cavity operation at gradients of 50 MV / m in an external magnetic field of three tesla, through the use of beryllium cavity elements. This eliminates a significant technical risk that has previously been inherent in ionization cooling channel designs.

43 PARTICLE ACCELERATORS↗

Tesla Model 3 Autopilot On-road Data

This dataset encompasses about 60 individual drives of a 2020 Tesla Model 3 with Autopilot in its relevant operational domain covering more than 1,000 miles. The majority of the data was collected during highway and suburban driving. Information collected includes vehicle CAN data as well as Lidar and camera data from a vehicle mounted sensor array. Vehicle CAN data and information on traffic surrounding the Ego-vehicle derived from the sensor array are postprocessed and merged to provide one combined CVS data file per drive. ![tesla m3 image](tesla-m3.png)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Vacuum RF Breakdown of Accelerating Cavities in Multi-Tesla Magnetic Fields

Ionization cooling of intense muon beams requires the operation of high-gradient, normal-conducting RF structures within multi-Tesla magnetic fields. The application of strong magnetic fields has been shown to lead to an increase in vacuum RF breakdown. This phenomenon imposes operational (i.e. gradient) limitations on cavities in ionization cooling channels, and has a bearing on the design and operation of other RF structures as well, such as photocathodes and klystrons. We present recent results from Fermilab's MuCool Test Area (MTA), in which 201 and 805 MHz cavities were operated at high power both with and without the presence of multi-Tesla magnetic fields. We present an analysis of damage due to breakdown in these cavities, as well as measurements related to dark current and their relation to a conceptual model describing breakdown phenomena.

43 PARTICLE ACCELERATORS↗

Commissioning of the LCLS-II Prototype HOM Detectors with Tesla-Type Cavities at Fast

Experiments at the Fermilab Accelerator Science and Technology* (FAST) facility detected electron beam-induced high order mode (HOM) signals from Tesla superconducting cavities. This paper describes some of the signal detection hardware used in this experiment, as well as measurements of the HOM signal magnitude versus beam trajectory. These measurements were made both with a single bunch and with a train of 50 bunches at bunch charges from 400 pC/b down to 10 pC/b. The detection hardware is designed for use with the Tesla superconducting cavities of LCLS-II at SLAC** and is based on a prototype already in use at Fermilab. The HOM signal passes through a bandpass filter that is centered on several cavity dipole modes and a zero bias Schottky diode detects its magnitude. Direct comparisons were made between the FNAL chassis and the SLAC prototype for identical beam steering conditions. To support measurements with bunch charges as low as 10 pC, the SLAC detector has RF amplification between the bandpass filter and the diode detector. With this hardware, usable HOM signal measurements are obtained with a single bunch of 10 pC in cryomodule cavities as will be needed for LCLS-II.

43 PARTICLE ACCELERATORS↗

Observations On Submicropulse Electron-beam Effects From Short-range Wakefields In Tesla-type Superconducting RF Cavities

aExperiments were performed at The Fermilab Accelerator Science and Technology (FAST) facility to elucidate the effects of short-range wakefields (SRWs) in TESLA-type rf cavities. FAST has a unique configuration of a photocathode rf gun beam injecting two TESLA-type single cavities (CC1 and CC2) in series prior to the cryomodule. To investigate short-range wakefield effects, we have steered the beam to minimize the signals in the higher-order mode (HOM) detectors of CC1 and CC2 for a baseline, and then selected a vertical corrector to steer the beam off axis at an angle into CC1 or CC2. A Hamamatsu synchro-scan streak camera viewing a downstream OTR screen provided an image of y-t effects within the micropulses with ~10-micron spatial resolution and 2-ps temporal resolution. At 500 pC/b, 50 b, and 2 mrad off-axis steering into CC2, we observed an ~ 100-micron head-tail centroid shift in the streak camera image y(t)-profiles. This centroid shift value is consistent wit h a calculated short-range wakefield effect using ASTRA simulations.

43 PARTICLE ACCELERATORS↗

Investigations of Long-Range Wakefield Effects in a TESLA-type Cryomodule at FAST

The preservation of low emittance of electron beams during transport in the accelerating structures of large facilities is an ongoing challenge. In the cases of the TESLA-type superconducting rf cavities currently used in the European X-ray Free-electron Laser (XFEL) and the under-construction Linac Coherent Light Source upgrade (LCLS-II), off-axis beam transport may result in emittance dilution due to transverse long-range wakefields (LRWs) and short-range wakefields (SRW)***. To investigate such effects, experiments were performed at the Fermilab Accelerator Science and Technology (FAST) facility with its unique configuration of two TESLA-type cavities after the photocathode rf gun followed by an 8-cavity cryomodule CM). We generated beam trajectory changes with the H/V125 corrector set located 4 m upstream of the cryomodule. At 125 pC/bunch, 50 bunches, 25-MeV input, and 100-MeV exit energy, we observed for the first time submacropulse position slews of up to 500 microns at locations ~3 m after the CM and a centroid oscillation at a difference frequency of 240 kHz further downstream. Both are emittance-dilution effects which we mitigated with selective upstream beam steering.

43 PARTICLE ACCELERATORS↗