Search NASASearch

SEARCH · Search NASA

Results for “TEST CHAMBER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A section 110 evaluation of the huron king test chamber, area 3, nevada national security site, nye county, nevada

The U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office tasked Desert Research Institute (DRI) with the identification and evaluation of the Huron King Test Chamber as part of their cultural resources program obligations under Section 110 of the National Historic Preservation Act. The Huron King nuclear test was a vertical line-of-sight weapons effects test that took place in Area 3 on June 24, 1980. Unique to this event was a specially designed aboveground test chamber that held a model defense communications satellite in a vacuum tank meant to replicate the space environment. Sponsored by the Defense Nuclear Agency, the purpose of the experiment was to understand the response of the satellite and its materials and equipment to an electromagnetic pulse and attendant radiation. Between July and August 2022, DRI conducted an archival review on the Huron King experiment and its associated test chamber. Subsequently, pedestrian fieldwork was undertaken at the Huron King Test Chamber by DRI on September 29, 2022. During fieldwork, the outside of the test chamber was documented using a Nevada State Historic Preservation Office Architectural Resource Assessment form. This effort included verifying the substructures that compose the test chamber as determined by the archival review, as well as obtaining a detailed photographic recordation of the exterior and assessing its current condition. Notably, the site where the Huron King test took place has been abandoned and almost entirely naturalized. All of the portable instrumentation trailers, communications and data cabling, and winch systems used to retract the test chamber following the detonation were removed after completion of the experiment in 1980. Only the subsidence crater and the test chamber remain as physical evidence of this experiment. Based on these findings, DRI recommends that the Huron King Test Chamber is eligible for listing in the National Register of Historic Places (NRHP) at the local level under Significance Criteria A and C and that it meets Criteria Consideration G for properties less than 50 years old.

54 ENVIRONMENTAL SCIENCES

The hygrothermal performance of continuous and cavity wood fiber insulation

Wood fiber insulation is an emerging material known for its effective thermal performance and moisture management properties, making it a compelling alternative to conventional insulation. Its vapor permeability and ability to regulate indoor humidity contribute to improved building durability and comfort, particularly in varying climate conditions. The goal of this project is to characterize the hygrothermal performance of a new wood fiber insulation product line in U.S. climate zones and to facilitate the design and construction of the product in residential and light commercial building envelopes. This study investigates the thermal and hygrothermal performance of wood fiber insulation, both as continuous and cavity insulation. The research employs an exhaustive simulation task and an environmental chamber test of a wood fiber insulation. Over 400 simulations were conducted to study the hygrothermal characteristics of bio-based wood fiber insulation in various building envelope configurations across four climate zones. Environmental chamber tests were conducted under controlled winter conditions representative of Climate Zone 5A (Chicago, IL) to complement the simulation results. The chamber tests focused on the hygrothermal performance of the wood fiber insulation and the sheathing board to assess the insulation's ability to manage moisture in a cold climate. Simulation and environmental chamber test results were analyzed to evaluate the insulation's consistency and efficacy across diverse climatic zones. Results show that with a proper moisture control strategy, both cavity and continuous wood fiber insulation can work properly in both new and retrofit constructions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

The Hygrothermal Performance of Continuous and Cavity Wood Fiber Insulation

Wood fiber insulation is an emerging material known for its effective thermal performance and moisture management properties, making it a compelling alternative to conventional insulation. Its vapor permeability and ability to regulate indoor humidity contribute to improved building durability and comfort, particularly in varying climate conditions. The goal of this project is to characterize the hygrothermal performance of a new wood fiber insulation product line in U.S. climate zones and to facilitate the design and construction of the product in residential and light commercial building envelopes. This study investigates the thermal and hygrothermal performance of wood fiber insulation, both as continuous and cavity insulation. The research employs an exhaustive simulation task and an environmental chamber test of a wood fiber insulation. Over 400 simulations were conducted to study the hygrothermal characteristics of bio-based wood fiber insulation in various building envelope configurations across four climate zones. Environmental chamber tests were conducted under controlled winter conditions representative of Climate Zone 5A (Chicago, IL) to complement the simulation results. The chamber tests focused on the hygrothermal performance of the wood fiber insulation and the sheathing board to assess the insulation's ability to manage moisture in a cold climate. Simulation and environmental chamber test results were analyzed to evaluate the insulation's consistency and efficacy across diverse climatic zones. Results show that with a proper moisture control strategy, both cavity and continuous wood fiber insulation can work properly in both new and retrofit constructions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Novel Technology of Non-Contact Real-Time Radiation Damage Sensor for High Power Targets

High-power proton beams planned for forthcoming long-baseline neutrino experiments will subject solid targets to unprecedented radiation damage, threatening reliability and increasing costs. To address this challenge, we are building a real-time, non-contact sensor that tracks damage by measuring broadband laser reflectivity changes from the target surface. A low-power super-continuum Class 3B laser illuminates the sample inside a vacuum test chamber while a high-resolution fiber-coupled spectrometer captures S- and P-polarized light; spectral shifts reveal defect-driven variations in optical constants. My internship goal is to design, build, and commission this prototype by implementing a laser-safety interlock and light shield, integrating remote-operation cameras, and fabricating modular 3-D-printed mounts that enable tool-free swaps without disturbing alignment. The laser, spectrometer, and vacuum chamber have been delivered; interlock hardware, cameras, and mounts are in final assembly, and leak testing of the chamber is underway. Upcoming work will focus on initial calibration of the sensor and executing first beam-irradiation studies.

Pumarino, Rafael

Ultra-high temperature testing and performance of L-PBF C103

Additive Manufacturing (AM) of refractory alloys is gaining traction as a materials processing route for components subject to extreme temperature environments. Due to the low oxidation resistance of refractory alloys, novel methods for evaluating their elevated temperature performance must be developed. In this work, a Gleeble® 3800 thermomechanical load frame was modified to evaluate the mechanical properties of laser powder bed fusion (L-PBF) consolidated niobium alloy C103 ranging from room temperature (RT) to 1400 °C. The fixturing and sample geometry were designed to accommodate Joule heating and prevent damage to the test chamber. Oxidation of the samples was minimized via testing in vacuum level of 1E-5 Torr. Ultimate tensile strength (UTS), yield strength (YS), elongation, and strain-hardening behavior were determined as a function of temperature. L-PBF C103 presented an average UTS of ∼650 MPa and over 25 % elongation at RT. Above RT, the UTS and YS dropped then leveled off from 500 °C to 1000 °C with values ranging from ∼400 MPa to ∼460 MPa, which is consistent with dynamic strain aging observed in this class of alloys. The strength rapidly declined after 1200 °C to ∼150 MPa at 1400 °C. Fractography indicated ductile fractures for the C103 at all test temperatures, and Electron Backscatter Diffraction (EBSD) analysis revealed a textured microstructure and the presence of dynamic recrystallization within the necked region of the sample tested at 1400 °C.

33 ADVANCED PROPULSION SYSTEMS

Development and performance evaluation of active insulation systems using solid-state thermal switches

Traditional building envelopes have passive insulation systems that cannot respond to dynamic changes in the environment. An Active Insulation System (AIS) consists of Active Insulation Materials (AIMs) that dynamically vary the thermal conductivity of the insulation system. Several researchers have evaluated the impact of AIS on building thermal and energy performance by using simulation tools. Up to 70% savings in annual heating and cooling energy and significant reductions in peak demand have been predicted for some climates with wall systems employing AIS. However, materials and assembly development still need a cost-effective product that achieves the required performance. Here, in this study, we present the process of developing an AIS that we will install in a test hut for its performance evaluation. Minimum performance criteria of the AIS system are developed based on R-low/R-high ratio, required time and efficiency to switch states, and cost estimates. The following steps during this study are creating the concept to meet the requirements, predicting the performance via simulations, developing the experimental setup for bench-scale testing, and finally, constructing a full-scale wall assembly and monitoring the performance when exposed to environmental chamber tests. The selected approach uses off-the-shelf products to create an AIS that can switch R-value between 0.98 ft 2 ·°F·h/BTU (0.173 m 2 ·K/W) and 5.81 ft 2 ·°F·h/BTU (1.02 m 2 ·K/W) and have a switching time of less than one minute between R-high and R-low.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Novel technology of non-contact real-time radiation damage sensors for high power targets.

This report summarizes the contributions of an intern participating in the Community College Internship (CCI) program at Fermilab, focusing on the development of a novel, non-contact, real-time radiation damage sensor technology. The core objective is to create a reliable sensor capable of measuring radiation-induced degradation on high-power targets without physical contact. The experiment involves using a Class 3B supercontinuum laser directed toward a single material sample placed within a vacuum test chamber. The laser beam reflects off the sample's surface, with changes in reflectivity, indicative of radiation damage, measured by a spectrometer positioned at the chamber’s output port. The intern’s primary responsibilities included designing an interlock system to ensure laser operational safety, developing a camera-based monitoring system using Raspberry Pi devices, and creating structural supports using 3D modeling and printing techniques. Components for the interlock and camera systems were successfully designed and ordered, with preliminary 3D models printed and refined through iterative testing. Challenges encountered in the 3D printing process, such as fragile initial prototypes and difficult support removal, were overcome by adjusting printer settings and incorporating design enhancements like chamfered edges. Future activities, pending component delivery, involve installing and configuring the interlock and camera systems, as well as further improving the structural supports. Overall, the internship significantly enhanced the intern’s technical proficiency in hardware design, software integration, and advanced 3D printing, contributing directly to Fermilab’s operational safety standards and experimental effectiveness in high-energy physics research.

Pumarino Meza, Rafael [Unlisted; Fermilab]

Composite coatings from polycarbosilane derived SiC and Al/SiC cermet active fillers as protective barriers against steel corrosion

Stainless steel is used throughout the world as a structural material. However, it undergoes corrosion damage when exposed to extremely corrosive media, such as the marine environment. An alternative to solve this problem lies in the development of coatings that can withstand extreme conditions but also be easily deposited with inherently corrosion-resistant materials such as silicon carbide (SiC). The present study shows a simple method to produce Al/SiC cermet powders by attrition milling. The resulting cermet powders with a metallic matrix and hemispherical morphology, were employed as fillers in polycarbosilane (PCS) solutions that were sprayed on A304 stainless steel substrates. Al/SiC composite coatings were produced after heating the sprayed suspensions at 700 °C for 1 h in Ar atmosphere. The resulting composite coatings exhibited low surface energies (< 35 mN/m), water contact angles of 53°, and adhesion strength of up to 30 MPa. Finally, corrosion tests were performed in a cyclic corrosion test chamber, showing that these coatings effectively reduced the corrosion rate of stainless steel by 87%, reaching corrosion rate values of 0.007 g/cm 2 year.

36 MATERIALS SCIENCE

Reducing the Cost of Fatigue Crack Growth Testing for Storage Vessel Steels in Hydrogen Gas

Hydrogen storage pressure vessels are designed against fatigue crack growth, and the ASME Boiler and Pressure Vessel Code requires the fatigue crack growth rate (da/dN) vs. stress-intensity factor range (ΔK) relationship of the construction steel to be measured directly in hydrogen gas. These measurements are notoriously slow and expensive: the cyclic loading frequencies prescribed by standards (often 0.1 Hz) are two or more orders of magnitude below those for conventional fatigue testing, individual tests run for days to weeks, and the high-pressure test-chamber set-up imposes a significant per-specimen labor cost. Due to these time and cost constraints, near-threshold data—the regime most valuable for extending design fatigue life—are rarely generated for ferritic storage vessel steels in hydrogen gas.

08 HYDROGEN

Neutron production and dosimetry with D(D,n) 3 He, 12 C(D,n) 13 N and 7 Li(p,n) 7 Be reactions at the Sandia Ion Beam Laboratory

Neutrons are produced at the Sandia Ion Beam Laboratory (IBL) using a beam of 280 keV D 2 + ions onto an erbium deuteride target. At test locations in the forward direction these neutrons have energies of about 2.9 MeV and a maximum flux on the flange of the test chamber of about 10 10 n/cm 2 /hour. Dosimetry is done by counting associated charged particles and by nickel foil activation dosimetry. Neutrons with higher energies, up to 6 MeV are produced using higher energy deuterium, up to 3 MeV, from the Pelletron ion accelerator at the IBL on a deuteride target. This report provides detailed information on the methods used for the production and dosimetry of neutrons by the D(D,n) 3 He nuclear reaction at the IBL. Neutron production by the 7 Li(p,n) 7 Be reaction with a proton beam from the Pelletron on a lithium target, such as LiF is also discussed. This produces neutrons with lower energy, in the range from about 0.1 to 1.3 MeV. Neutron production by the 12 C(D,n) 13 N reaction is also discussed. The purpose of this report is to provide information needed to test the effects of neutron irradiation on semiconductor materials and devices at the Sandia IBL.

36 MATERIALS SCIENCE

Lab Evaluation of Downward Capacity of Radiant Ceiling Panel Systems

This project investigated the cooling delivery effectiveness of radiant ceiling panels as a function of attic insulation level using multiple laboratory testing and analytical methodologies. Delivery effectiveness is the heating or cooling energy delivered to a conditioned space divided by the total heating or cooling energy added or removed by the space conditioning system. The lower the losses of the heating or cooling delivery method, the higher the delivery effectiveness. For ducted systems, delivery effectiveness is reduced by both air leakage and thermal losses (especially if the ducts are installed in attics), while the delivery effectiveness of a radiant system supplied by hot and cold water is only reduced by thermal losses, which can be mitigated by sufficient insulation above, or at the "back" of the panel. Being installed at or below the ceiling plane, sufficient back insulation should be provided by default in the form of the attic insulation above the radiant ceiling panels. Site-built radiant ceiling panels were evaluated at Frontier Energy’s Building Science Research Laboratory (BSRL) in a uniquely designed environmental test chamber with independently controllable indoor and attic spaces and a height-adjustable ceiling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Fast permeability measurement for tight reservoir cores using only initial data of the one chamber pressure pulse decay test

Here, in this study, a mathematical model for fast determination of the permeabilities of tight rocks using measurements taken from the initial period of the One Chamber Pressure Pulse Decay (OC-PPD) test is presented. The model applies to measurements taken both before and after the pressure pulse front has reached the downstream end of the specimen. The analytical solutions for the pressure decay in the upstream chamber are derived based on a parabolic arc approximation of pore pressure distribution along the test specimen. This approximation allows converting the initial–boundary value problem of fluid diffusion in the specimen, governed by partial differential equations, to a system of ordinary differential equations that can be easily solved by explicit formulae. Thus, an explicit formula for the pressure decay rate is obtained, which enables inverse analysis of the initial experimental data to estimate the rock permeability. The proposed method expedites the pulse decay test as it does not require the system to reach equilibrium. The method is validated with three sets of experimental data of the OC-PPD test using helium as the diffusing fluid, for which the relative error of the permeability is found to be less than 6%. This method is particularly useful if the equilibrium time of the pulse decay test for rock specimens with permeabilities in the range of nano-Darcy takes hours or days.

early-time solution

A flexible test facility for liquid xenon detector development

As liquid xenon time projection chambers scale to ever-larger sizes, so too do the engineering challenges they pose. Here, we describe a large, flexible, multipurpose test facility capable of supporting the development of a number of key aspects of liquid xenon detector systems. Example applications of this facility include characterization of large-area light and charge sensor arrays, tests of xenon purification techniques and materials compatibility, and investigations into high-voltage phenomena. This facility uses an automated and remotely monitored cryo-cooling system based on immersion of the test chamber in a liquid bath rather than conductive coupling, leading to advantages in temperature and pressure stability, as well as increasing required response times in the case of cooling-power loss. Design advantages, operational procedures, and performance of the facility are described, as well as five examples of liquid xenon test chambers that use the facility.

Dark Matter detectors

Artificial Replication of Field Soiling Losses on PV Modules

In this paper, we experimentally demonstrate an improved replication of field soiling losses using an indoor artificial soiling chamber and tests on anti-soiling coated PV modules and coupons. The primary focus is to use site-specific soil collected from module surface and replicate the natural soiling processes including dust concentration in the air, slow and gradual dust accumulation and sedimentation on the module surface during the dominant soiling season of the site of interest. The experiments were conducted on two sample sets having different anti-soiling properties. The first set contains commercial modules with two different surface properties retrieved after three years of exposure from a single PV plant in a mid-Atlantic location; the other set contain glass coupons with three different coating materials that were installed and exposed over 4 months, at Lemoore, California. Major field-representative factors considered here for the close replication in the chamber include: the use of dust collected from modules surfaces at the outdoor sites to give the same dust chemistry; dust particle size distribution and concentration; the charge size of dust (< 0.15 g per injection); field humidity, and module temperature. The effectiveness of antisoiling coatings (or surface properties) for both sample sets were ranked in the artificial testing and were found to be closely matching with the field rank orders of the respective sites and sample sets. This paper provides the rank ordering results to objectively demonstrate the replication of field soiling losses in the artificial soiling chamber.

artificial soiling

Design and Study of Inductively Coupled Plasma Chamber Components Using the SupRISE Test Device at DIII-D

The DIII-D National Fusion Facility aims to increase the auxiliary heating power for the tokamak by upgrading the Neutral Beam Injection (NBI) system. In collaboration with North Carolina State University, the conventional ‘arc and filament’ NBI ion sources will be converted to inductively coupled plasma (ICP) sources which utilize radio frequency (RF) coupling to maximize reliability for high power operation. In support of this initiative, a full scale test device (SupRISE, Superior Radiofrequency Ion Source Experiment) is currently under construction at the DIII-D Facility. In preparation for the construction of a full scale prototype that can be installed on the DIII-D NBI system, experiments on SupRISE will be conducted to determine the optimal RF frequency for high power coupling, Faraday shield slit configuration, and ICP chamber length. SupRISE is comprised of an approximately 30 x 70 cm quartz dielectric vessel with an internal Faraday shield enclosed in a secondary vacuum chamber to ensure structural stability of the dielectric. Actively cooled front and back plates are designed to reduce the thermal stresses on the plasma facing components and mate with the existing accelerator used by the NBI system at DIII-D. 50 kW of RF power will be coupled to the plasma through the quartz over a variable frequency range of 4-8 MHz to sustain a plasma density of ∼ 10 18 m −3 for a 10 s ON, 210 s OFF duty cycle. Various modelling efforts have been employed to simulate the thermal and stress profiles over the primary components of the SupRISE device as well as the inductance behavior of the RF antenna. These simulation results and the final design for SupRISE will be presented. An additional reduced-scale predecessor ICP source (called RISE) has been used to develop a predictive match model that will be applied to frequency optimization studies on SupRISE. Furthermore, the outcomes of this research and complementary efforts at North Carolina State University are essential for the incorporation of ICP NBI positive ion sources at the DIII-D facility.

DIII-D

A 24-channel ultra-low-noise preamplifier for dN/dx measurements with drift tube detectors

Cluster counting $(dN/dx)$ is a promising method to enhance particle identification for gaseous detectors, especially in next-generation collider experiments like the FCC-ee, where good $π/K$ separation over a broad momentum range is essential. However, its implementation in large-scale systems has been limited by the challenging requirements for high-resolution signal amplification and readout. This paper presents a 24-channel ultra-low-noise preamplifier board designed for drift tube detectors to enable $dN/dx$ measurements. The three-stage amplification topology employs SiGe transistors and integrates dedicated noise-minimization techniques, achieving a charge gain of 21.11 mV/fC from 0.3 fC to 50 fC, a bandwidth of 542 MHz, and a voltage gain of 47.8 dB. The measured voltage noise density is 0.35 nV/$\sqrt{\textrm{Hz}}$ , surpassing most of the state-of-the-art preamplifiers for gaseous and silicon detectors. Validation tests conducted on the sMDT chambers at the CERN Proton Synchrotron test beam facility demonstrate that the proposed design meets the stringent preamplifier requirements for implementing the $dN/dx$ method in drift-tube detector systems, achieving an equivalent noise charge of 0.14 fC and a signal-to-noise ratio of 73 when operated with a He:iC 4 H 10 (90:10) gas mixture. The design also shows promise for broader application in other gaseous or semiconductor detectors.

Drift tube detector

Thermal Performance of Spandrel Assemblies in Glazed Wall Systems: Laboratory Test Design – Challenges and Test Results

Accurate thermal performance calculation procedures for opaque spandrel areas in curtain wall and window wall systems are essential for rating systems when comparing spandrel systems. However, there is a lack of consensus in thermal modeling needed for accurately characterizing heat transfer through spandrel assemblies due to the complex arrangement of materials and structural components. Several studies indicate that conventional 2D thermal simulations may overestimate R-values by 30% compared to physical testing and 3D simulations. Detailed simulations and well-curated laboratory test data are necessary to build confidence in simulation models, which will later be used to develop correlations to improve widely used conventional 2D thermal simulations. This study aims to experimentally test heat transfer through various spandrel assemblies to validate 3D simulation models. Also, the challenges of conducting a thorough testing design along with the solutions would be documented. The team developed a design for testing spandrel assemblies, making appropriate modifications to the existing heat, air, and moisture (HAM) chamber to accommodate the testing needs. Two moveable baffles were designed and fabricated to guide airflow direction parallel to the test article surface. The data acquisition capabilities in the chamber were upgraded to add more than two hundred sensors to the climate and indoor side of the chamber. The goal is to provide a quality dataset for validating complex 3D modeling simulations, which will be used to develop improved thermal simulation techniques that more accurately represent the thermal behavior of spandrel assemblies and their integration within the building envelope. This paper will summarize the results for the boundary conditions of the testing and the temperature variation across different locations of the spandrel assemblies.

Kunwar, Niraj [ORNL] (ORCID:0000000263457652)