Determination of Fiber Volume in Carbon/Cyanate Ester Composites Using Thermogravimetric Analysis (TGA)

The resin content, and by extension the fiber volume, of carbon fiber/cyanate ester composite laminates are measured using thermogravimetric analysis (TGA). Conventional measurement involves acid digestion of the laminate to determine resin content. The mean difference between techniques is 0.03%. In addition to eliminating the hazards and environmental impact of standard acid digestion, the TGA technique allows quantification of errors associated with fiber volume measurements, e.g. incomplete resin removal or fiber degradation. An additional benefit of the TGA technique is a reduction in sample size requirements, allowing the examination of fiber volume changes in complex shapes.

Sovinski, Marjorie F.↗

Trace Gas Analyzer (TGA) program

The design, fabrication, and test of a breadboard trace gas analyzer (TGA) is documented. The TGA is a gas chromatograph/mass spectrometer system. The gas chromatograph subsystem employs a recirculating hydrogen carrier gas. The recirculation feature minimizes the requirement for transport and storage of large volumes of carrier gas during a mission. The silver-palladium hydrogen separator which permits the removal of the carrier gas and its reuse also decreases vacuum requirements for the mass spectrometer since the mass spectrometer vacuum system need handle only the very low sample pressure, not sample plus carrier. System performance was evaluated with a representative group of compounds.

Source record↗

Methods of Measuring Vapor Pressures of Lubricants With Their Additives Using TGA and/or Microbalances

The life of a space system may be critically dependent on the lubrication of some of its moving parts. The vapor pressure, the quantity of the available lubricant, the temperature and the exhaust venting conductance passage are important considerations in the selection and application of a lubricant. In addition, the oil additives employed to provide certain properties of low friction, surface tension, antioxidant and load bearing characteristics, are also very important and need to be known with regard to their amounts and vapor pressures. This paper reports on the measurements and analyses carried out to obtain those parameters for two often employed lubricants, the Apiezon(TM)-C and the Krytox(TM) AB. The measurements were made employing an electronic microbalance and a thermogravimetric analyzer (TGA) modified to operate in a vacuum. The results have been compared to other data on these oils when available. The identification of the mass fractions of the additives in the oil and their vapor pressures as a function of the temperature were carried out. These may be used to estimate the lubricant life given its quantity and the system vent exhaust conductance. It was found that the Apiezon(TM)-C has three main components with different rates of evaporation while the Krytox(TM) did not indicate any measurable additive.

Scialdone, John J.↗

Glycoalkaloids in potato tubers grown under controlled environments

Tuber content of alpha-solanine, alpha-chaconine, and total glycoalkaloids (TGA) was determined for the potato cultivars, Norland, Russet Burbank, and Denali grown under different environmental conditions in growth chambers. The lowest TGA concentrations (0.30 to 0.35 mg g-1 dry tissue) were found in the cv. Norland with 400 micromoles m-2 s-1 photosynthetic photon flux (PPF), 12 h day length, 16 C temperature, and 350 micromoles mol-1 carbon dioxide. The ratio of alpha-chaconine to alpha-solanine was close to 60:40 under all growing conditions, except that it was 50:50 under the low temperature of 12 C. Cultivars responded similarly to environmental conditions although TGA was about 20% greater in cv. Russet Burbank and about 30% greater in Denali compared to Norland. The largest changes in TGA occurred with changes in temperature. In comparison to 16 C, TGA were 40% greater at 12 C, 80% greater at 20 C, and 125% greater at 24 C (0.70 mg g-1 dry weight). The TGA concentration increased from 10 to 25% with an increase in light from 400 to 800 micromoles m-2 s-1 PPF for all three cultivars. TGA increased 20% with extension of the day length from 12 to 24 hr and also increased 20% when carbon dioxide was increased from 350 to 1000 micromoles mol-1. TGA concentrations were not influenced by changes in relative humidity from 50 to 80%. TGA concentrations decreased only slightly in harvests made from 9 to 21 weeks after planting. Variations in TGA among the different growing conditions and cultivars were below 20 mg/100 g fresh weight (approximately 1.0 mg g-1 dry weight) recognized as the upper concentration for food safety. However the results suggest that TGA should be considered when potatoes are grown at temperatures above 20 C.

NASA Discipline Life Support Systems↗

Thermal Properties of Lunar Regolith Simulants

Various high temperature chemical processes have been developed to extract oxygen and metals from lunar regolith. These processes are tested using terrestrial analogues of the regolith. But all practical terrestrial analogs contain H2O and/or OH-, the presence of which has substantial impact on important system behaviors. We have undertaken studies of lunar regolith simulants to determine the limits of the simulants to validate key components for human survivability during sustained presence on the Moon. Differential Thermal Analysis (DTA) yields information on phase transitions and melting temperatures. Thermo-Gravimetric Analysis (TGA) with Fourier Transform Infrared (FTIR) analysis provides information on evolved gas species and their evolution temperature profiles. The DTA and TGA studies included JSC-1A fine (Johnson Space Center Mare Type 1A simulant), NU-LHT-2M (National Aeronautics and Space Administration (NASA)-- United States Geological Survey (USGS)--Lunar Highlands Type 2M simulant) and its proposed feedstocks: anorthosite; dunite; high quality (HQ) glass and the norite from which HQ glass is produced. As an example, the DTA and TGA profiles for anorthosite follow. The DTA indicates exothermic transitions at 355 and 490 C and endothermic transitions at 970 and 1235 C. Below the 355 C transition, water is lost accounting for approximately 0.1 percent mass loss. Just above 490 C a second type of water is lost, presumably bound in lattices of secondary minerals along with other volatile oxides. Limited TGA-FTIR data is available at the time of this writing. For JSC-1A fine, the TGA-FTIR indicates at least two kinds of water are evolved in the 100 to 500 and the 700 to 900 C ranges. Evolution of carbon dioxide types occurs in the 250 to 545, 545 to 705, and 705 to 985 C ranges. Geologically, the results are consistent with the evolution of "water" in its several forms, CO2 from break down of secondary carbonates and magmatic, dissolved gas and glass recrystallization

Street, Kenneth W., Jr.↗

Isothermal thermogravimetric data acquisition analysis system

The description of an Isothermal Thermogravimetric Analysis (TGA) Data Acquisition System is presented. The system consists of software and hardware to perform a wide variety of TGA experiments. The software is written in ANSI C using Borland's Turbo C++. The hardware consists of a 486/25 MHz machine with a Capital Equipment Corp. IEEE488 interface card. The interface is to a Hewlett Packard 3497A data acquisition system using two analog input cards and a digital actuator card. The system provides for 16 TGA rigs with weight and temperature measurements from each rig. Data collection is conducted in three phases. Acquisition is done at a rapid rate during initial startup, at a slower rate during extended data collection periods, and finally at a fast rate during shutdown. Parameters controlling the rate and duration of each phase are user programmable. Furnace control (raising and lowering) is also programmable. Provision is made for automatic restart in the event of power failure or other abnormal terminations. Initial trial runs were conducted to show system stability.

Cooper, Kenneth, Jr.↗

New Screening Test Developed for the Blanching Resistance of Copper Alloys

NASA's extensive efforts towards more efficient, safer, and more affordable space transportation include the development of new thrust-cell liner materials with improved capabilities and longer lives. For rocket engines fueled with liquid hydrogen, an important metric of liner performance is resistance to blanching, a phenomenon of localized wastage by cycles of oxidation-reduction due to local imbalance in the oxygen-fuel ratio. The current liner of the Space Shuttle Main Engine combustion chamber, a Cu-3Ag-0.5Zr alloy (NARloy-Z) is degraded in service by blanching. Heretofore, evaluating a liner material for blanching resistance involved elaborate and expensive hot-fire tests performed on rocket test stands. To simplify that evaluation, researchers at the NASA Glenn Research Center developed a screening test that uses simple, in situ oxidation-reduction cycling in a thermogravimetric analyzer (TGA). The principle behind this test is that resistance to oxidation or to the reduction of oxide, or both, implies resistance to blanching. Using this test as a preliminary tool to screen alloys for blanching resistance can improve reliability and save time and money. In this test a small polished coupon is hung in a TGA furnace at the desired (service) temperature. Oxidizing and reducing gases are introduced cyclically, in programmed amounts. Cycle durations are chosen by calibration, such that all copper oxides formed by oxidation are fully reduced in the next reduction interval. The sample weight is continuously acquired by the TGA as usual.

Thomas-Ogbuji, Linus U.↗

Thermogravimetric Analysis of Single-Wall Carbon Nanotubes

An improved protocol for thermogravimetric analysis (TGA) of samples of single-wall carbon nanotube (SWCNT) material has been developed to increase the degree of consistency among results so that meaningful comparisons can be made among different samples. This improved TGA protocol is suitable for incorporation into the protocol for characterization of carbon nanotube material. In most cases, TGA of carbon nanotube materials is performed in gas mixtures that contain oxygen at various concentrations. The improved protocol is summarized.

Arepalli, Sivram↗

Requirements document for mini system test unit

The mini system test unit (STU) for the Trace Gas Analyzer (TGA) is defined. The interface signals of the components used to implement the STU are also defined. The mini STU is used to support pre-flight ground test operations. The STU indications of TGA operation (organic and carbon monoxide analyses) and its ability to monitor gas chromatograph and mass spectrometer test signals are included.

Garofolo, D.↗

Development of acceptance criteria for batches of silane primer for external tank thermal protection system bonding applications

Silane primers for use as thermal protection on external tanks were subjected to various analytic techniques to determine the most effective testing method for silane lot evaluation. The analytic methods included high performance liquid chromatography, gas chromatography, thermogravimetry (TGA), and fourier transform infrared spectroscopy (FTIR). It is suggested that FTIR be used as the method for silane lot evaluation. Chromatograms, TGA profiles, bar graphs showing IR absorbances, and FTIR spectra are presented.

Mikes, F.↗

Evaluation of moisture barrier coatings on carbon-phenolic SRM nozzle materials

The carbon-phenolic composite ablative material used on the Solid Rocket Motor (SRM) nozzle is known to absorb moisture from the atmosphere. This could cause problems such as pocketing during firing. Several moisture barrier coatings were tested on the SRM nozzle material. Data are presented for six of the 12 coatings to be tested. The data were obtained from immersion of coated samples in an environmental chamber at 100 F and 100% relative humidity and by using a modified TGA (thermal gravimetric analysis) technique. The TGA technique involved allowing wet nitrogen (25 C, 80% relative humidity) to flow across a small sample at about 65 cu cm per minute while continually monitoring the weight increase. These preliminary results show Kel-F-800, a material supplied by 3M Corporation to be the better moisture barrier. A second task was to collect data on the relative absorption of water and kerosene into the carbon-phenolic SRM nozzle material. These data indicate that water absorbs into the nozzle material to a much greater extent than kerosene. Thus kerosene is the more likely solvent in which to make specific gravity measurements on the SRM nozzle material.

Mcnutt, Ronald C.↗

Effects of orbital exposure on Halar during the LDEF mission

Thermomechanical Analysis (TMA), Differential Scanning Calorimetry (DSC), and Thermogravimetric Analysis (TGA) were performed on samples of Halar exposed on the LDEF Mission for 6 years in orbit and unexposed Halar control samples. Sections 10-100 microns thick were removed from the exposed surface down to a depth of 1,000 microns through the 3 mm thick samples. The TMA and DSC results, which arise from the entire slice and not just its surface, showed no differences between the LDEF and the control samples. TMA scans were run from ambient to 300 C; results were compared by a tabulation of the glass transition temperatures. DSC scans were run from ambient to 700 C; the enthalpy of melting was compared for the samples as a function of section depth with the sample. The TGA results, which arise from the surface of the sample initially, showed a sharp increase in the topmost 50 micron section (the exposed, discolored side) in the weight loss of 170 C in oxygen. This weight loss dropped to bulk values in the range of depth of 50-200 microns. The control sample showed only a slight increase in weight loss as the top surface was approached. The LDEF Halar sample appears to be mechanically undamaged, with a surface layer which oxidizes faster as a result of orbital exposure.

Brower, William E., Jr.↗

Kinetic parameters from thermogravimetric analysis

High performance polymeric materials are finding increased use in aerospace applications. Proposed high speed aircraft will require materials to withstand high temperatures in an oxidative atmosphere for long periods of time. It is essential that accurate estimates be made of the performance of these materials at the given conditions of temperature and time. Temperatures of 350 F (177 C) and times of 60,000 to 100,000 hours are anticipated. In order to survey a large number of high performance polymeric materials on a reasonable time scale, some form of accelerated testing must be performed. A knowledge of the rate of a process can be used to predict the lifetime of that process. Thermogravimetric analysis (TGA) has frequently been used to determine kinetic information for degradation reactions in polymeric materials. Flynn and Wall studied a number of methods for using TGA experiments to determine kinetic information in polymer reactions. Kinetic parameters, such as the apparent activation energy and the frequency factor, can be determined in such experiments. Recently, researchers at the McDonnell Douglas Research Laboratory suggested that a graph of the logarithm of the frequency factor against the apparent activation energy can be used to predict long-term thermo-oxidative stability for polymeric materials. Such a graph has been called a kinetic map. In this study, thermogravimetric analyses were performed in air to study the thermo-oxidative degradation of several high performance polymers and to plot their kinetic parameters on a kinetic map.

Kiefer, Richard L.↗

Effects of orbital exposure on RTV during the LDEF mission

Thermomechanical analysis (TMA), differential scanning calorimetry (DSC), and thermogravimetric analysis (TGA) were performed on samples of RTV 511 exposed on the Long Duration Exposure Facility (LDEF) mission for 6 years in orbit and unexposed RTV 511 control samples. Slices 20- to 400-microns thick were removed from the exposed surface down to a depth of 1,500 microns through the 3-mm thick samples. The TMA and DSC results, which arise from the entire slice and not just its surface, showed no significant differences between the LDEF exposed and the control samples. TMA scans were run from ambient to 500 C; results were compared by a tabulation of the onset temperatures for flow. DSC scans were run from ambient to 600 C; no endotherms or exotherms occurred over the range observed. What appear to be glass transition temperatures were compared for the samples as a function of section depth within the sample and between the exposed and control samples. The TGA scans from 25 to 900 C, which arise from the surface of the sample initially, showed a slight increase in the top most 105-micron slice (the exposed, discolored side) in the weight loss at 600 C in oxygen. This weight loss dropped to bulk values at the next slice below the top section, a mean depth of 258 microns. The control sample also showed an increase in weight loss as the top surface was approached, but the 600 C weight losses were very inconsistent. The LDEF RTV sample appears to be mechanically undamaged, with a surface layer which oxidizes slightly faster as a result of orbital exposure.

Brower, William E., Jr.↗

High Modulus and High T(sub g) Thermally Stable Polymers from p-Ethynyl-Terminated Rigid-Rod Monomers

Novel p-ethynyl-substituted rigid rod monomers were studied by pressure Differential Scanning Calorimetry (DSC), ThermoGravimetric Analysis (TGA), IsothermoGravimetric Analysis (IGA), and TGA-IR. These monomers, 4,4'-bis(((4-ethynylphenyl)carbonyl)oxy)biphenyl, designated 1, 1,5-bis-(((4-ethynylphenyl)carbonyl)oxy)naphthalene, designated 2, and bis(4-ethynylphenyl)pyromellitimide, designated 3, were polymerized in the solid state. Thermal polymerization in N2 or air produced highly cross-linked resins with polymerization exotherms centered between 212 and 276 C. The (delta)H's of polymerization of these resins in air were found to be double those in N2. When monomers 1 and 2 were heated in air from 23 to 750 C at 10 C/min, the main decomposition product was carbon dioxide, evolving at a maximum rate between 500 and 600 C; water was also detected as a decomposition product. Void-free neat resin moldings, designated lp to 3p, were made by compression molding the monomers and then heating them. The resulting polymers were highly cross-linked, and their glass transition temperatures (T(sub g)) were much higher than their polymerization temperatures. Using ThermoMechanical Analysis (TMA), we found that polymers lp to 3p had T(sub g)'s of 422, 329, and 380 C, respectively. The thermal and thermooxidative stabilities improved when lp to 3p were postcured in N2 (the postcured polymers were designated 1pp to 3pp). The Linear Thermal Expansions (LTE) for lp and 3p were 1% between 23 and 420 C. Using rheological analysis, we could not clearly detect the T(sub g)'s of lp to 3p because their moduli dropped only slightly between 23 and 490 C and the changes in tan beta were very low. Because of high cross-link density, their moduli changed little as the resins went from a glassy to a rubbery state. Their shear storage moduli in air ranged from 0.82 (3p, 3pp) to 1.6 GPa (lpp) at 23 C, from 0.16 (2p) to 0.7GPa(lpp) at 380 C, and from 0.18(lpp)to 0.6GPa(2p) at 490 C. Finally, these novel-p-ethynyl polymers exhibited an excellent combination of high T(sub g), low LTE, and high thermooxidative stability. Most notably, 3pp lost only 3% of its initial weight when it was aged for 500 h at 288 C in air.

Melissaris, Anastasios P.↗

Assessment of Uncertainty in the Determination of Activation Energy for Polymeric Materials

An assessment of the experimental uncertainty in obtaining the kinetic activation energy from thermogravimetric analysis (TGA) data is presented. A neat phenolic resin, Borden SC1O08, was heated at three heating rates to obtain weight loss vs temperature data. Activation energy was calculated by two methods: the traditional Flynn and Wall method based on the slope of log(q) versus 1/T, and a modification of this method where the ordinate and abscissa are reversed in the linear regression. The modified method produced a more accurate curve fit of the data, was more sensitive to data nonlinearity, and gave a value of activation energy 75 percent greater than the original method. An uncertainty analysis using the modified method yielded a 60 percent uncertainty in the average activation energy. Based on this result, the activation energy for a carbon-phenolic material was doubled and used to calculate the ablation rate In a typical solid rocket environment. Doubling the activation energy increased surface recession by 3 percent. Current TGA data reduction techniques that use the traditional Flynn and Wall approach to calculate activation energy should be changed to the modified method.

Darby, Stephania P.↗

Use of Several Thermal Analysis Techniques on a Hypalon Paint Coating for the Solid Rocket Booster (SRB) of the Space Shuttle

White Hypalon paint is brush-applied as a moisture barrier coating over cork surfaces on each of the two Space Shuttle SRBS. Fine cracks have been observed in the Hypalon coating three times historically on laboratory witness panels, but never on flight hardware. Recent samples of the cracked and standard ("good") Hypalon were removed from cork surfaces and were tested by Thermal Gravimetric Analysis (TGA), Thermomechanical (TMA) and Differential Scanning Calorimetry (DSC) thermal analysis techniques. The TGA data showed that at 700 C, where only paint pigment solids remain, the cracked material had about 9 weight percent more material remaining than the standard material, probably indicating incomplete mixing of the paint before it was brush-applied to produce the cracked material. Use of the TMA film tension method showed that the average static modulus vs. temperature was about 3 to 6 times higher for the cracked material than for the standard material, indicating a much higher stiffness for the cracked Hypalon. The TMA data also showed than an increased coating thickness for the cracked Hypalon was not a factor in the anomaly.

Wingard, Charles D.↗

Long Term Degradation of Resin for High Temperature Composites

The durability of polymer matrix composites exposed to harsh environments is a major concern. Surface degradation and damage are observed in polyimide composites used in air at 125 to 300 C. It is believed that diffusion of oxygen into the material and oxidative chemical reactions in the matrix are responsible. Previous work has characterized and modeled diffusion behavior, and thermogravimetric analyses (TGAs) have been carried out in nitrogen, air, and oxygen to provide quantitative information on thermal and oxidative reactions. However, the model developed using these data was not able to capture behavior seen in isothermal tests, especially those of long duration. A test program that focuses on lower temperatures and makes use of isothermal tests was undertaken to achieve a better understanding of the degradation reactions under use conditions. A new low-cost technique was developed to collect chemical degradation data for isothermal tests lasting over 200 hr in the temperature range 125 to 300 C. Results indicate complex behavior not captured by the previous TGA tests, including the presence of weight-adding reactions. Weight gain reactions dominated in the 125 to 225 C temperature range, while weight loss reactions dominated beyond 225 C. The data obtained from isothermal tests was used to develop a new model of the material behavior. This model was able to fully capture the behavior seen in the tests up to 275 C. Correlation of the current model with both isothermal data at 300 C and high rate TGA test data is mediocre. At 300 C and above, the reaction mechanisms appear to change. Attempts (which failed) to measure non-oxidative degradation indicate that oxidative reactions dominate the degradation at low temperatures. Based on this work, long term isothermal testing in an oxidative atmosphere is recommended for studying the degradation behavior of this class of materials.

Patekar, Kaustubh A.↗