Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMAL NEUTRON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Neutron thermalization in nuclear graphite: A modern story of a classic moderator

Graphite has been of great interest since the dawn of the nuclear era. In this work, we will focus on the thermal neutron scattering of two types of nuclear graphite that have different microstructures, namely, the historic PGA which has a very anisotropic medium-grained needle coke, and the new G347A which is a near-isotropic fine-grained graphite. We report the results of room temperature inelastic neutron scattering measurements for the scattering function, double differential scattering cross-section, and phonon density of states. The obtained results are discussed in conjunction with results extracted from first-principles lattice dynamics simulations of crystalline graphite, using the incoherent approximation and by also including the coherent-one phonon contribution. Excellent agreements have been found between the measured and calculated scattering functions and phonon densities of states. The inclusion of the coherent-one phonon scattering shows a significant improvement of the calculated scattering functions, double differentials, and inelastic scattering cross-sections. We also highlight the physical concerns about the current thermal neutron scattering ENDF/B-VIII of nuclear graphite library and its corresponding phonon density of states. This work aims to provide a new presentation of neutron thermalization by graphite and offers a new set of high quality experimental and computational data for consideration.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Method for manufacturing solid-state thermal neutron detectors with simultaneous high thermal neutron detection efficiency (>50%) and neutron to gamma discrimination (>1.0E4)

Methods for manufacturing solid-state thermal neutron detectors with simultaneous high thermal neutron detection efficiency (>50%) and neutron to gamma discrimination (>10.sup.4) are provided. A structure is provided that includes a p+ region on a first side of an intrinsic region and an n+ region on a second side of the intrinsic region. The thickness of the intrinsic region is minimized to achieve a desired gamma discrimination factor of at least 1.0E+04. Material is removed from one of the p+ region or the n+ region and into the intrinsic layer to produce pillars with open space between each pillar. The open space is filed with a neutron sensitive material. An electrode is placed in contact with the pillars and another electrode is placed in contact with the side that is opposite of the intrinsic layer with respect to the first electrode.

36 MATERIALS SCIENCE↗

Report on the Tin-II Thermal Neutron Detector

Thermal neutrons have recently become a concern in the semiconductor community where it has been reported that approximately 20% of the single-event upsets are due to thermal neutrons in some devices. The goal of this project is to measure the intensity of thermal neutrons in the High- Performance Computing (HPC) area. This is part of a larger effort to characterize the radiation environment in the HPC area which includes high-energy neutrons as well as thermal neutrons. To accomplish this goal, we designed and fabricated a neutron detector that is sensitive to thermal neutrons called Tin-II. The Tin-II detector consists of two identical 3He ionization chambers with one detector bare and one detector shielded with cadmium. Because the cadmium shielding effectively blocks the thermal neutrons, the difference in count rates between these two detectors reflect the number of thermal neutrons detected. This report summarizes the status of our efforts to develop this detector.

47 OTHER INSTRUMENTATION↗

Thermal Neutron Imaging Using A New Pad-Based Position Sensitive Neutron Detector

Thermal neutrons (with mean energy of 25 meV) have a scattering mean free path of about 20 m in air. Therefore it is feasible to find localized thermal neutron sources up to ~30 m standoff distance using thermal neutron imaging. Coded aperture thermal neutron imaging was developed in our laboratory in the nineties, using He-3 filled wire chambers. Recently a new generation of coded-aperture neutron imagers has been developed. In the new design the ionization chamber has anode and cathode planes, where the anode is composed of an array of individual pads. The charge is collected on each of the individual 5x5 mm2 anode pads, (48x48 in total, corresponding to 24x24 cm2 sensitive area) and read out by application specific integrated circuits (ASICs). The high sensitivity of the ASICs allows unity gain operation mode. The new design has several advantages for field deployable imaging applications, compared to the previous generation of wire-grid based neutron detectors. Among these are the rugged design, lighter weight and use of non-flammable stopping gas. For standoff localization of thermalized neutron sources a low resolution (11x11 pixel) coded aperture mask has been fabricated. Using the new larger area detector and the coarse resolution mask we performed several standoff experiments using moderated californium and plutonium sources at Idaho National Laboratory. In this paper we will report on the development and performance of the new pad-based neutron camera, and present long range coded-aperture images of various thermalized neutron sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermal Neutron Captures on d and {sup 3}He

We report on a study of the nd and n{sup 3}He radiative captures at thermal neutron energies, using wave functions obtained from either chiral or conventional two- and three-nucleon realistic potentials with the hyperspherical-harmonics method, and electromagnetic currents derived in chiral effective field theory up to one loop. The predicted nd and n{sup 3}He cross sections are in good agreement with data, but exhibit a significant dependence on the input Hamiltonian. A comparison is also made between these and new results for the nd and n{sup 3}He cross sections obtained in the conventional framework for both potentials and currents.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Advanced Modeling and Simulation Methods for Evaluation of Thermal Neutron Scattering Materials

With the rise of interest in thermal neutron scattering data for advanced reactor, criticality safety, and shielding applications, new experimental data are required for evaluation of new materials or for re-evaluation (or validations) of previously evaluated materials. New experimental data are evaluated in a three-step process: (1) computing the phonon characteristics, (2) computing the dynamic structure factor (DSF) from the data, and (3) using the experimental setup to simulate the experimental data. All three steps have challenges, ranging from the need for a sufficiently general material simulation code—a processing code that can compute the corresponding DSF—to having a detailed layout of the instrument/beamline/facility where the data were measured. Whereas phonon characteristics of materials can be computed using various methods (molecular dynamics, density functional theory, etc.), a high-fidelity computation of the DSF and the simulation of the experiment based on the DSF is vital to the accuracy of the evaluation. The latter two steps can be achieved by using the two corresponding code systems developed by instrument scientists at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory: (1) OCLIMAX, a program that calculates the dynamic structure factor from DFT and MD simulation results, and (2) MCViNE, a Monte Carlo neutron ray-tracing program designed to simulate neutron scattering experiments. Recently, polyethylene and yttrium hydride were measured at the Wide Angular-Range Chopper (ARCS) and SEQUOIA instrument stations of the SNS. These experiments are simulated using the density functional theory code, the Cambridge Serial Total Energy Package (CASTEP), to compute its phonon characteristics (eigenvalues/vectors and PDOS), which is then processed using OCLIMAX to yield the DSF, and finally the data at each instrument station are simulated by the MCViNE for comparison to the measured data for evaluation. For comparison to conventional evaluation methods, the scattering data processed from OCLIMAX are compared against those processed from the LEAPR module of NJOY, and the results from MCViNE simulations are compared against previously used simplified beamline models implemented in the Monte Carlo N-Particle (MCNP) code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uncertainty Quantification of a Light Water Pulsed-Neutron Die-Away Experiment to Thermal Neutron Scattering Laws

Thermal neutron scattering laws are important nuclear data for many nuclear science and engineering applications. Validation helps to ensure that a thermal neutron scattering law has a high quality and often employs critical benchmarks as integral experiments. Recently, pulsed-neutron die-away benchmarks have been used as an experiment to validate thermal neutron scattering laws. Herein, we evidence how this alternative integral experiment has a high sensitivity to these nuclear data by performing an uncertainty quantification analysis. The analysis randomly sampled the nuclear model parameters associated with hydrogen bound in light water thermal neutron scattering law and sampled other nuclear data that influenced the experiment’s integral parameter (e.g., elastic scattering, absorption in hydrogen and oxygen) from their respective covariance matrices. The thermal neutron scattering law caused an uncertainty in the integral parameter that reached 2.67%, which exceeds by an order of magnitude the uncertainties induced in commonly used thermal solution critical benchmarks. The validation performed here, although limited due to a poor description of the historical experiment, indicated that the ENDF/B-VIII.0 thermal neutron scattering law well predicted the integral parameter. These results motivate further benchmark and validation efforts using pulsed-neutron die-away experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development and Evaluation of Neutron Thermalization Integral Benchmarks for Advanced Reactor Applications (Final Report)

In this project, integral benchmarks that aim to examine thermal neutron scattering data for graphite (ideal and nuclear), light water, and molten salt FLiBe will be analyzed. In particular, the project aims to: 1) Develop the slowing-down-time experiment that was performed at the OREAL facility of ORNL as a graphite benchmarks; 2) Identify and examine a slowing-down-time experiment in light water as a potential benchmark; 3) Reexamine the molten salt MSRE-MSR-EXP-001 benchmark to explicitly capture the impact of TSL variations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Boron-10 Doped Polysiloxanes as Matrix Materials for Application in the Simultaneous Detection and Discrimination of Gamma Rays and Fast and Thermal Neutrons

Three boron-10 enriched aromatic molecules have been synthesized and incorporated into two different commercial polysiloxane resins, Shin Etsu KER-6000 and Wacker SilRes H62-C. Scintillating fluorophores, 9,9-dimethyl-2-phenylfluorene (PhF) and 2,5-diphenyloxazole (PPO), were tested in combination with each resin and boron-10 molecule for the simultaneous detection of gamma rays, fast neutrons, and thermal neutrons. Here, the H62-C resin was able to solubilize a large amount of PhF, in excess of 20 wt%. Cure kinetics were controlled through the addition of divinylbenzene and phenyl tris(dimethylsiloxy)silane cross-linker solution to the H62-C resin, with rheology experiments demonstrating a large reduction in time to gelation when 20 wt% cross-linker solution was added, from more than 4 hours to less than 1 hour. These polysiloxane resins can be cured in 3 hours under air, while common poly(vinyltoluene) scintillators require at least 4 days of heating and oxygen-free conditions. PhF-doped KER-6000 with tolyl boronate pinacol ester exhibited the best overall performance with a light yield of 62% relative to EJ-200 and thermal neutron capture at energies up to 103 keVee (84 keVee for EJ254B-5). Additionally, four samples exhibited light yields surpassing an industry-standard boron-doped plastic scintillator, Eljen’s EJ254B-5. Over the course of ten months, the KER-6000 samples showed precipitation of dopant molecules, which reduced their light yield by 15% on average, while H62-C proved to be more stable with only a 6% reduction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Current Issues in Nuclear Data Evaluation Methodology: {sup 235}U Prompt Fission Neutron Spectra and Multiplicity for Thermal Neutrons

Issues in evaluation methodology of the prompt fission neutron spectra (PFNS) and neutron multiplicity for the thermal-neutron-induced fission of the {sup 235}U are discussed. The inconsistency between the experimental differential and integral data is addressed. By using differential data as ”shape data” good consistency was achieved between available sets of differential data. Integral dosimetry data have been used to define the PFNS slope at high outgoing neutron energies, where the quality of the differential data is poor. The inclusion into the fit of measured integral (spectrum-averaged) cross sections had a very small impact in the region where differential PFNS data are abundant and accurate, but removed the discrepancy with integral data at higher neutron emission energies. All experimental data are consistently fitted giving a PFNS average energy of 2.008 MeV. The impact on criticality prediction of the newly evaluated PFNS was tested. The highly enriched {sup 235}U solution assemblies with high leakage HEU-SOL-THERM-001 and HEU-SOL-THERM-009 benchmarks are the most sensitive to the PFNS. Criticality calculations for those solutions show a significant increase in reactivity if the average neutron energy of the fission neutrons is reduced from the ENDF/B-VI.5 value of 2.03 MeV. The proposed reduction of the PFNS average energy by 1.1% can be compensated by reducing the average number of neutrons per fission ν{sup ¯} at the thermal energy to the Gwin et al. measured value. The simple least-squares PFNS fit was confirmed by a more sophisticated combined fit of differential PFNS data for {sup 233,235}U, {sup 239}Pu and {sup 252}Cf nuclides with the generalised least-squares method using the GMA and GANDR codes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Large area position sensitive detector for thermal neutrons

Large area thermal neutron detectors are applied in many fields including industrial imaging, nuclear safeguarding, neutron scattering, and fundamental science. Historically, these detectors were based on 3 He gas proportional counters despite the limitations of 3 He detectors such as high cost, limited supply, non-uniform spatial resolution, and depth of absorption problems. Two alternatives to 3 He detectors are 6 Li-loaded glass scintillators, and powdered ZnS(Ag) scintillators mixed with 6LiF neutron converters. The 6 LiF/ZnS(Ag) scintillator has advantages over 6 Li glass as it is less expensive and can be produced in larger areas, although its self-absorption presents a problem. In this work, we developed a large area thermal neutron detector based on 6 LiF/ZnS(Ag) scintillator coupled with wavelength shifting fibers. The detector uses resistive charge divider-based position encoding. We further modified and improved the method by 2D segmentation of the detector using modular multichannel readout electronics. This segmentation approach allows for a combination of large detector area, improved spatial resolution, and increased count rate. Furthermore, spatial resolution can be variable across the detector area by adjusting the segment size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rhodium self-powered neutron detector as a suitable on-line thermal neutron flux monitor in BNCT treatments

Purpose: A rhodium self-powered neutron detector (Rh SPND) has been specifically developed by the Comision Nacional de Energia Atomica (CNEA) of Argentina to measure locally and in real time thermal neutron fluxes in patients treated with boron neutron capture therapy (BNCT). In this work, the thermal and epithermal neutron response of the Rh SPND was evaluated by studying the detector response to two different reactor spectra. In addition, during clinical trials of the BNCT Project of the CNEA, on-line neutron flux measurements using the specially designed detector were assessed. Methods: The first calibration of the detector was done with the well-thermalized neutron spectrum of the CNEA RA-3 reactor thermal column. For this purpose, the reactor spectrum was approximated by a Maxwell-Boltzmann distribution in the thermal energy range. The second calibration was done at different positions along the central axis of a water-filled cylindrical phantom, placed in the mixed thermal-epithermal neutron beam of CNEA RA-6 reactor. In this latter case, the RA-6 neutron spectrum had been well characterized by both calculation and measurement, and it presented some marked differences with the ideal spectrum considered for SPND calibrations at RA-3. In addition, the RA-6 neutron spectrum varied with depth in the water phantom and thus the percentage of the epithermal contribution to the total neutron flux changed at each measurement location. Local (one point-position) and global (several points-positions) and thermal and mixed-field thermal neutron sensitivities were determined from these measurements. Thermal neutron flux was also measured during BNCT clinical trials within the irradiation fields incident on the patients. In order to achieve this, the detector was placed on patient's skin at dosimetric reference points for each one of the fields. System stability was adequate for this kind of measurement. Results: Local mixed-field thermal neutron sensitivities and global thermal and mixed-field thermal neutron sensitivities derived from measurements performed at the RA-6 were compared and no significant differences were found. Global RA-6-based thermal neutron sensitivity showed agreement with pure thermal neutron sensitivity measurements performed in the RA-3 spectrum. Additionally, the detector response proved nearly unchanged by differences in neutron spectra from real (RA-6 BNCT beam) and ideal (considered for calibration calculations at RA-3) neutron source descriptions. The results confirm that the special design of the Rh SPND can be considered as having a pure thermal response for neutron spectra with epithermal-to-thermal flux ratios up to 12%. In addition, the linear response of the detector to thermal flux allows the use of a mixed-field thermal neutron sensitivity of 1.95 {+-} 0.05 x 10{sup -21} A n{sup -1}{center_dot}cm{sup 2}{center_dot}s. This sensitivity can be used in spectra with up to 21% epithermal-to-thermal flux ratio without significant error due to epithermal neutron and gamma induced effects. The values of the measured fluxes in clinical applications had discrepancies with calculated results that were in the range of -25% to +30%, which shows the importance of a local on-line independent measurement as part of a treatment planning quality control system. Conclusions: The usefulness of the CNEA Rh SPND for the on-line local measurement of thermal neutron flux on BNCT patients has been demonstrated based on an appropriate neutron spectra calibration and clinical applications.

07 ISOTOPE AND RADIATION SOURCES↗

A Workflow to Optimize Fast Neutron Irradiation in A Thermal Neutron Spectrum Test Reactor Leveraging Open-Source Tools

The Advanced Test Reactor (ATR) located at Idaho National Laboratory (INL) is one of the key nuclear engineering research and testing facilities within the US Department of Energy (DOE). The ATR is one of few high-power research reactors in the world with different application including accelerated testing of nuclear fuel, materials irradiation in a very high neutron flux environment, and medical radioisotope production [1]. Also, the ATR offers opportunities for testing fast spectrum fission and fusion reactor materials. The key challenges in this area are in further detailing and optimizing a fast spectrum environment within a thermal test reactor. This challenge involves researching, developing, and testing novel concepts for the multiplying of neutron populations into ever higher energy spectra in high flux test reactors like ATR. The main objective of this work is to investigate candidate materials for establishing a fast neutron experiment irradiation in thermal neutron spectrum test reactors which can be accomplished by filtering thermal and epithermal neutrons and boosting fast neutrons at designated irradiation positions. However, adding these filters will render the neutron spectrum and the criticality of the system. The selection of the thickness and material layers should be accomplished by developing an optimization design algorithm that is applicable for ATR to enhance the fast neutron spectrum irradiation utilizing high-fidelity Monte Carlo methods along with advanced machine learning capabilities. This paper presents workflow for design optimization to enhance fast neutron irradiation in the ATR. The workflow leverages open-source tools to develop an algorithm that is viable to ATR and can be leveraged in other reactors. The following sections discuss the development of the experiment design optimization workflow and its application to ATR irradiation positions.

42 - ENGINEERING↗

Microstructure of Neutron-Irradiated Al 3 Hf-Al Thermal Neutron Absorber Materials

A thermal neutron-absorbing metal matrix composite (MMC) comprised of Al 3 Hf particles in an aluminum matrix was developed to filter out thermal neutrons and create a fast flux environment for material testing in a mixed-spectrum nuclear reactor. Intermetallic Al 3 Hf particles capture thermal neutrons and are embedded in a highly conductive aluminum matrix that provides conductive cooling of the heat generated due to thermal neutron capture by the hafnium. These Al 3 Hf-Al MMCs were fabricated using powder metallurgy via hot pressing. The specimens were neutron-irradiated to between 1.12 and 5.38 dpa and temperatures ranging from 286 °C to 400 °C. The post-irradiation examination included microstructure characterization using transmission electron microscopy (TEM) and energy-dispersive X-ray spectroscopy. This study reports the microstructural observations of four irradiated samples and one unirradiated control sample. All the samples showed the presence of oxide at the particle–matrix interface. The irradiated specimens revealed needle-like structures that extended from the surface of the Al 3 Hf particles into the Al matrix. An automated segmentation tool was implemented based on a YOLO11 computer vision-based approach to identify dislocation lines and loops in TEM images of the irradiated Al-Al 3 Hf MMCs. This work provides insight into the microstructural stability of Al 3 Hf-Al MMCs under irradiation, supporting their consideration as a novel neutron absorber that enables advanced spectral tailoring.

36 MATERIALS SCIENCE↗

Enhancement of sub-thermal neutron flux through cold polyethylene

Total thermal neutron cross section measurements serve as the primary means of validation for thermal neutron scattering kernels, an important quantity for neutron transport calculations. In an effort to improve the quality of thermal neutron scattering kernels, researchers at Rensselaer Polytechnic Institute (RPI) designed and constructed a polyethylene based cold moderation system to enhance neutron flux below 10 meV when coupled with the Enhanced Thermal Target (ETT) at the RPI Gaerttner LINAC. The final design yielded an increase in sub-thermal neutron flux (below 10 meV) by a factor of 4.5 for a moderator temperature of 37.5 K relative to the ETT alone. A further increase to a factor of 6 is expected after a minor geometry modification and decrease in polyethylene temperature to 25 K. This novel capability will be used to conduct total thermal neutron cross section measurements from 0.0005–10 eV for different materials including moderator materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma discrimination in pillar structured thermal neutron detectors

Solid-state thermal neutron detectors are desired to replace {sup 3}He tube based technology for the detection of special nuclear materials. {sup 3}He tubes have some issues with stability, sensitivity to microphonics and very recently, a shortage of {sup 3}He. There are numerous solid-state approaches being investigated that utilize various architectures and material combinations. By using the combination of high-aspect-ratio silicon PIN pillars, which are 2 {micro}m wide with a 2 {micro}m separation, arranged in a square matrix, and surrounded by {sup 10}B, the neutron converter material, a high efficiency thermal neutron detector is possible. Besides intrinsic neutron detection efficiency, neutron to gamma discrimination is an important figure of merit for unambiguous signal identification. In this work, theoretical calculations and experimental measurements are conducted to determine the effect of structure design of pillar structured thermal neutron detectors including: intrinsic layer thickness, pillar height, substrate doping and incident gamma energy on neutron to gamma discrimination.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗