Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMAL POWER PLANTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The application of simulation modeling to the cost and performance ranking of solar thermal power plants

Small solar thermal power systems (up to 10 MWe in size) were tested. The solar thermal power plant ranking study was performed to aid in experiment activity and support decisions for the selection of the most appropriate technological approach. The cost and performance were determined for insolation conditions by utilizing the Solar Energy Simulation computer code (SESII). This model optimizes the size of the collector field and energy storage subsystem for given engine generator and energy transport characteristics. The development of the simulation tool, its operation, and the results achieved from the analysis are discussed.

Rosenberg, L. S.↗

Thermal power plant upgrade via a rotating detonation combustor and retrofitted turbine with optimized endwalls

Over the past decade, pressure gain combustion research has promised over 10 percentage-points of increase in power plant thermal efficiency. Alas, to realize such potential gain, one must effectively couple the turbine with the detonation combustor, whose exhaust conditions differ substantially from current state of the art gas turbines. This paper presents a modeling approach that enables a superior thermodynamic cycle with a rotating detonation combustor and a retrofitted gas turbine by including a diffuser downstream of the combustor and by contouring the turbine endwall, while preserving the airfoil geometry. We propose a multi-step optimization strategy, parametrizing the endwall geometry with a few control points, without altering the airfoil geometry, and with the stage turbine efficiency as objective function. In a first step the turbine performance is assessed with steady inlet conditions by solving the steady three-dimensional Reynolds-Averaged Navier-Stokes equations. In a second step, the inlet conditions are unsteady, as predicted from a detonation combustor and a diffuser, and three-dimensional full unsteady simulations are performed with an unsteady Reynolds-Averaged Navier-Stokes solver. By altering the vane endwall, the steady optimization yielded an efficiency increase of 12% relative to the baseline, while the unsteady optimization resulted in 21% increase compared to the datum turbine. Finally, a full engine analysis demonstrated the superiority of pressure gain combustion which included a realistic thermodynamic cycle of the combustor, the diffuser and the optimized turbine components.

42 ENGINEERING↗

Comparison of advanced engines for parabolic dish solar thermal power plants

A paraboloidal dish solar thermal power plant produces electrical energy by a two-step conversion process. The collector subsystem is composed of a two-axis tracking paraboloidal concentrator and a cavity receiver. The concentrator focuses intercepted sunlight (direct, normal insolation) into a cavity receiver whose aperture encircles the focal point of the concentrator. At the internal wall of the receiver the electromagnetic radiation is converted to thermal energy. A heat engine/generator assembly then converts the thermal energy captured by the receiver to electricity. Developmental activity has been concentrated on small power modules which employ 11- to 12-meter diameter dishes to generate nominal power levels of approximately 20 kWe. A comparison of advanced heat engines for the dish power module is presented in terms of the performance potential of each engine with its requirements for advanced technology development. Three advanced engine possibilities are the Brayton (gas turbine), Brayton/Rankine combined cycle, and Stirling engines.

Fujita, T.↗

Thermal buffering of receivers for parabolic dish solar thermal power plants

A parabolic dish solar thermal power plant comprises a field of parabolic dish power modules where each module is composed of a two-axis tracking parabolic dish concentrator which reflects sunlight (insolation) into the aperture of a cavity receiver at the focal point of the dish. The heat generated by the solar flux entering the receiver is removed by a heat transfer fluid. In the dish power module, this heat is used to drive a small heat engine/generator assembly which is directly connected to the cavity receiver at the focal point. A computer analysis is performed to assess the thermal buffering characteristics of receivers containing sensible and latent heat thermal energy storage. Parametric variations of the thermal inertia of the integrated receiver-buffer storage systems coupled with different fluid flow rate control strategies are carried out to delineate the effect of buffer storage, the transient response of the receiver-storage systems and corresponding fluid outlet temperature. It is concluded that addition of phase change buffer storage will substantially improve system operational characteristics during periods of rapidly fluctuating insolation due to cloud passage.

Manvi, R.↗

Projected techno-economic improvements for advanced solar thermal power plants

The projected characteristics of solar thermal power plants (with outputs up to 10 MWe) employing promising advanced technology subsystems/components are compared to current (or pre-1985) steam-Rankine systems. Improvements accruing to advanced technology development options are delineated. The improvements derived from advanced systems result primarily from achieving high efficiencies via solar collector systems which (1) capture a large portion of the available insolation and (2) concentrate this captured solar flux to attain high temperatures required for high heat engine/energy conversion performance. The most efficient solar collector systems employ two-axis tracking. Attractive systems include the central receiver/heliostat and the parabolic dish.

Fujita, T.↗

Evaluation of solar thermal power plants using economic and performance simulations

An energy cost analysis is presented for central receiver power plants with thermal storage and point focusing power plants with electrical storage. The present approach is based on optimizing the size of the plant to give the minimum energy cost (in mills/kWe hr) of an annual plant energy production. The optimization is done by considering the trade-off between the collector field size and the storage capacity for a given engine size. The energy cost is determined by the plant cost and performance. The performance is estimated by simulating the behavior of the plant under typical weather conditions. Plant capital and operational costs are estimated based on the size and performance of different components. This methodology is translated into computer programs for automatic and consistent evaluation.

El-Gabawali, N.↗

Operation of a 250 MW solar thermal power plant

Operation of a 250 MW solar thermal power plant. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=5EE5B7E0-1B62-468A-8D6D-8337A21CF876

14 SOLAR ENERGY↗

Siting Issues for Solar Thermal Power Plants with Small Community Applications

Technologies for solar thermal plants are being developed to provide energy alternatives for the future. Implementation of these plants requires consideration of siting issues as well as power system technology. While many conventional siting considerations are applicable, there is also a set of unique siting issues for solar thermal plants. Early experimental plants will have special siting considerations. The siting issues associated with small, dispersed solar thermal power plants in the 1 to 10 MWe power range for utility/small community applications are considered. Some specific requirements refer to the first 1 MWe engineering experiment for the Small Power Systems Applications (SPSA) Project. The siting issues themselves are discussed in three categories: (1) system resource requirements, (2) environmental effects on the system, and (3) potential impact of the plant on the environment. Within these categories, specific issues are discussed in a qualitative manner. Examples of limiting factors for some issues are taken from studies of other solar systems.

Holbeck, J. J.↗

General volume sizing strategy for thermal storage system using phase change material for concentrated solar thermal power plant

With an auxiliary large capacity thermal storage using phase change material (PCM), Concentrated Solar Power (CSP) is a promising technology for high efficiency solar energy utilization. In a thermal storage system, a dual-media thermal storage tank is typically adopted in industry for the purpose of reducing the use of the heat transfer fluid (HTF) which is usually expensive. While the sensible heat storage system (SHSS) has been well studied, a dual-media latent heat storage system (LHSS) still needs more attention and study. The volume sizing of the thermal storage tank, considering daily cyclic operations, is of particular significance. In this paper, a general volume sizing strategy for LHSS is proposed, based on an enthalpy-based 1D transient model. One example was presented to demonstrate how to apply this strategy to obtain an actual storage tank volume. With this volume, a LHSS can supply heat to a thermal power plant with the HTF at temperatures above a cutoff point during a desired 6 hours of operation. This general volume sizing strategy is believed to be of particular interest for the solar thermal power industry.

14 SOLAR ENERGY↗

Choosing Actuators for Automatic Control Systems of Thermal Power Plants

Two types of actuators for automatic control systems of thermal power plants are analyzed: (i) pulse-controlled actuator and (ii) analog-controlled actuator with positioning function. The actuators are compared in terms of control circuit, control accuracy, reliability, and cost.

42 ENGINEERING↗

Method for evaluating the technical state of boilers and piping in thermal power plants

An approach for evaluating the current technical state of thermal equipment in thermal power plants is discussed. A system of parameters and corresponding criteria are developed for the technical state of groups of essential components of boilers and piping. Ascale for evaluation of safety factors is proposed in terms of the relationship between state parameters and the corresponding criteria. Analytic expressions are given for an approximate evaluation of the maximum lifetime limit for operation of an object in terms of an integral safety factor and an evaluation of this type is illustrated for the case of the live steam pipeline in a 300-MW unit. An algorithm is set up for actions to be taken by equipment owners in organizing monitoring of the technical state of the equipment.

20 FOSSIL-FUELED POWER PLANTS↗

Application of a reversible chemical reaction system to solar thermal power plants

Three distributed dish solar thermal power systems using various applications of SO2/SO3 chemical energy storage and transport technology were comparatively assessed. Each system features various roles for the chemical system: (1) energy storage only, (2) energy transport, or (3) energy transport and storage. These three systems were also compared with the dish-Stirling, using electrical transport and battery storage, and the central receiver Rankine system, with thermal storage, to determine the relative merit of plants employing a thermochemical system. As an assessment criterion, the busbar energy costs were compared. Separate but comparable solar energy cost computer codes were used for distributed receiver and central receiver systems. Calculations were performed for capacity factors ranging from 0.4 to 0.8. The results indicate that SO2/SO3 technology has the potential to be more cost effective in transporting the collected energy than in storing the energy for the storage capacity range studied (2-15 hours)

Hanseth, E. J.↗

Photovoltaic device for enhancing power output of concentrating solar thermal power plants

A photovoltaic retrofit device for a concentrating solar thermal power plant having a parabolic trough reflector, and a fluid receiver with working fluid therein spaced from the reflector and positioned at a focal point of the reflector. The photovoltaic device includes a plurality of adjustable angle dichroic mirrors positioned between the parabolic trough reflector and the fluid receiver. A photovoltaic receiver assembly has multiple photovoltaic panels in angular relationship to each other. A photovoltaic temperature regulating system includes a fluid medium to regulate temperature of the photovoltaic panels.

Otanicar, Todd↗

Thermal power systems small power systems application project: Siting issues for solar thermal power plants with small community applications

The siting issues associated with small, dispersed solar thermal power plants for utility/small community applications of less than 10 MWe are reported. Some specific requirements are refered to the first engineering experiment for the Small Power Systems Applications (SPSA) Project. The background for the subsequent issue discussions is provided. The SPSA Project and the requirements for the first engineering experiment are described, and the objectives and scope for the report as a whole. A overview of solar thermal technologies and some technology options are discussed.

Holbeck, H. J.↗

Optimization of Cooling Water Flow Rate in Nuclear and Thermal Power Plants Based on a Mathematical Model of Cooling Systems{sup 1}

A mathematical model and algorithms are proposed for automatic calculation of the optimum flow rate of cooling water in nuclear and thermal power plants with cooling systems of arbitrary complexity. An unlimited number of configuration and design variants are assumed with the possibility of obtaining a result for any computational time interval, from monthly to hourly. The structural solutions corresponding to an optimum cooling water flow rate can be used for subsequent engineering-economic evaluation of the best cooling system variant. The computerized mathematical model and algorithms make it possible to determine the availability and degree of structural changes for the cooling system in all stages of the life cycle of a plant.

42 ENGINEERING↗

Solar Thermal Power Plant, Assembly

This assembly process apportions the construction, installation, and operations requirements of equipment and materials used in the assembly of a solar thermal power plant. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=E2C74A9A-2115-49E2-964E-72131B2B26FA

14 SOLAR ENERGY↗

A program for the calculation of paraboloidal-dish solar thermal power plant performance

A program capable of calculating the design-point and quasi-steady-state annual performance of a paraboloidal-concentrator solar thermal power plant without energy storage was written for a programmable calculator equipped with suitable printer. The power plant may be located at any site for which a histogram of annual direct normal insolation is available. Inputs required by the program are aperture area and the design and annual efficiencies of the concentrator; the intercept factor and apparent efficiency of the power conversion subsystem and a polynomial representation of its normalized part-load efficiency; the efficiency of the electrical generator or alternator; the efficiency of the electric power conditioning and transport subsystem; and the fractional parasitic loses for the plant. Losses to auxiliaries associated with each individual module are to be deducted when the power conversion subsystem efficiencies are calculated. Outputs provided by the program are the system design efficiency, the annualized receiver efficiency, the annualized power conversion subsystem efficiency, total annual direct normal insolation received per unit area of concentrator aperture, and the system annual efficiency.

Bowyer, J. M., Jr.↗

Turbine sizing of a solar thermal power plant

Since the insolation is intermittent, thermal energy storage is necessary to extend the time of power generation with solar heat past sunset. There are two approaches to specifying the size of turbine-generator units depending on the system operation. In the first approach, the turbine operates at its full capacity when operating on direct solar heat, and at reduced capacity when operating on collected heat out of energy storage. In the second approach, the turbine will always operate at a uniform level either on derated energy from the receiver or from energy storage. Both of these approaches have certain advantages and disadvantages. In this paper, a simple analysis is outlined and exercised to compare the performance and economics of these two approaches.

Manvi, R.↗