Thermal power plant upgrade via a rotating detonation combustor and retrofitted turbine with optimized endwalls

Over the past decade, pressure gain combustion research has promised over 10 percentage-points of increase in power plant thermal efficiency. Alas, to realize such potential gain, one must effectively couple the turbine with the detonation combustor, whose exhaust conditions differ substantially from current state of the art gas turbines. This paper presents a modeling approach that enables a superior thermodynamic cycle with a rotating detonation combustor and a retrofitted gas turbine by including a diffuser downstream of the combustor and by contouring the turbine endwall, while preserving the airfoil geometry. We propose a multi-step optimization strategy, parametrizing the endwall geometry with a few control points, without altering the airfoil geometry, and with the stage turbine efficiency as objective function. In a first step the turbine performance is assessed with steady inlet conditions by solving the steady three-dimensional Reynolds-Averaged Navier-Stokes equations. In a second step, the inlet conditions are unsteady, as predicted from a detonation combustor and a diffuser, and three-dimensional full unsteady simulations are performed with an unsteady Reynolds-Averaged Navier-Stokes solver. By altering the vane endwall, the steady optimization yielded an efficiency increase of 12% relative to the baseline, while the unsteady optimization resulted in 21% increase compared to the datum turbine. Finally, a full engine analysis demonstrated the superiority of pressure gain combustion which included a realistic thermodynamic cycle of the combustor, the diffuser and the optimized turbine components.

42 ENGINEERING↗

Investigation of coal stockpiles of Tuncbilek thermal power plant with respect to time under atmospheric conditions

Thermal power plants have delayed the coal that they will use at stockpiles mandatorily. If these coal stockpiles remain at the stockyards over a certain period of time, a spontaneous combustion can be started itself. Coal stocks under combustion threat can cost too much economically to coal companies. Therefore, it is important to take some precautions for saving the stockpiles from the spontaneous combustion. In this research a coal stockpile at Tuncbilek Thermal Power Plant which was formed in 5 m wide, 10 m long, and 3 m height with a weight of 120 tons to observe internal temperature changes with respect to time under normal atmospheric conditions. Later, internal temperature measurements were obtained at 20 points distributed all over two layers in the stockpile. The parameters, such as air temperature, humidity, atmosphere pressure, wind speed and direction, which are effective on the stockpiles, were measured and used to obtain the graphs of stockpiles' internal temperature.

01 COAL, LIGNITE, AND PEAT↗

Experience in connecting the power generating units of thermal power plants to automatic secondary frequency regulation within the united power system of Russia

The principles of central control of the power generating units of thermal power plants by automatic secondary frequency and active power overcurrent regulation systems, and the algorithms for interactions between automatic power control systems for the power production units in thermal power plants and centralized systems for automatic frequency and power regulation, are discussed. The order of switching the power generating units of thermal power plants over to control by a centralized system for automatic frequency and power regulation and by the Central Coordinating System for automatic frequency and power regulation is presented. The results of full-scale system tests of the control of power generating units of the Kirishskaya, Stavropol, and Perm GRES (State Regional Electric Power Plants) by the Central Coordinating System for automatic frequency and power regulation at the United Power System of Russia on September 23-25, 2008, are reported.

42 ENGINEERING↗

Operation of a 250 MW solar thermal power plant

Operation of a 250 MW solar thermal power plant. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=5EE5B7E0-1B62-468A-8D6D-8337A21CF876

14 SOLAR ENERGY↗

General volume sizing strategy for thermal storage system using phase change material for concentrated solar thermal power plant

With an auxiliary large capacity thermal storage using phase change material (PCM), Concentrated Solar Power (CSP) is a promising technology for high efficiency solar energy utilization. In a thermal storage system, a dual-media thermal storage tank is typically adopted in industry for the purpose of reducing the use of the heat transfer fluid (HTF) which is usually expensive. While the sensible heat storage system (SHSS) has been well studied, a dual-media latent heat storage system (LHSS) still needs more attention and study. The volume sizing of the thermal storage tank, considering daily cyclic operations, is of particular significance. In this paper, a general volume sizing strategy for LHSS is proposed, based on an enthalpy-based 1D transient model. One example was presented to demonstrate how to apply this strategy to obtain an actual storage tank volume. With this volume, a LHSS can supply heat to a thermal power plant with the HTF at temperatures above a cutoff point during a desired 6 hours of operation. This general volume sizing strategy is believed to be of particular interest for the solar thermal power industry.

14 SOLAR ENERGY↗

Choosing Actuators for Automatic Control Systems of Thermal Power Plants

Two types of actuators for automatic control systems of thermal power plants are analyzed: (i) pulse-controlled actuator and (ii) analog-controlled actuator with positioning function. The actuators are compared in terms of control circuit, control accuracy, reliability, and cost.

42 ENGINEERING↗

Use of GTE-65 gas turbine power units in the thermal configuration of steam-gas systems for the refitting of operating thermal electric power plants

Thermal configurations for condensation, district heating, and discharge steam-gas systems (PGU) based on the GTE-65 gas turbine power unit are described. A comparative multivariant analysis of their thermodynamic efficiency is made. Based on some representative examples, it is shown that steam-gas systems with the GTE-65 and boiler-utilizer units can be effectively used and installed in existing main buildings during technical refitting of operating thermal electric power plants.

42 ENGINEERING↗

Method for evaluating the technical state of boilers and piping in thermal power plants

An approach for evaluating the current technical state of thermal equipment in thermal power plants is discussed. A system of parameters and corresponding criteria are developed for the technical state of groups of essential components of boilers and piping. Ascale for evaluation of safety factors is proposed in terms of the relationship between state parameters and the corresponding criteria. Analytic expressions are given for an approximate evaluation of the maximum lifetime limit for operation of an object in terms of an integral safety factor and an evaluation of this type is illustrated for the case of the live steam pipeline in a 300-MW unit. An algorithm is set up for actions to be taken by equipment owners in organizing monitoring of the technical state of the equipment.

20 FOSSIL-FUELED POWER PLANTS↗

Photovoltaic device for enhancing power output of concentrating solar thermal power plants

A photovoltaic retrofit device for a concentrating solar thermal power plant having a parabolic trough reflector, and a fluid receiver with working fluid therein spaced from the reflector and positioned at a focal point of the reflector. The photovoltaic device includes a plurality of adjustable angle dichroic mirrors positioned between the parabolic trough reflector and the fluid receiver. A photovoltaic receiver assembly has multiple photovoltaic panels in angular relationship to each other. A photovoltaic temperature regulating system includes a fluid medium to regulate temperature of the photovoltaic panels.

Otanicar, Todd↗

Improved Electrical Load Match In California By Combining Solar Thermal Power Plants with Wind Farms

California with its hydro, geothermal, wind, and solar energy is the second largest producer of renewable electricity in the United States (Washington state is the largest producer of renewable energy electricity due to high level of hydro power). Replacing fossil fuel electrical generation with renewable energy electrical generation will decrease the release of carbon dioxide into the atmosphere which will slow down the rapid increase in global warming (a goal of the California state government). However, in order for a much larger percentage of the total electrical generation in California to be from renewable energies like wind and solar, a better match between renewable energy generation and utility electrical load is required. Using wind farm production data and predicted production from a solar thermal power plant (with and without six hours of storage), a comparison was made between the renewable energy generation and the current utility load in California. On a monthly basis, wind farm generated electricity at the three major wind farm areas in California (Altamont Pass, east of San Francisco Bay area; Tehachapi Pass in the high desert between Tehachapi and Mojave; and San Gorgonio Pass in the low desert near Palm Springs) matches the utility load well during the highest electrical load months (May through September). Prediction of solar thermal power plant output also indicates a good match with utility load during these same high load months. Unfortunately, the hourly wind farm output during the day is not a very good match to the utility electrical load (i.e. in spring and summer the lowest wind speed generally occurs during mid-day when utility load is highest). If parabolic trough solar thermal power plants are installed in the Mojave Desert (similar to the 354 MW of plants that have been operating in Mojave Desert since 1990) then the solar electrical generation will help balance out the wind farm generation since highest solar generated electricity will be during mid-day. Adding six hours of solar thermal storage improved the utility load match significantly in the evening and reliability was also improved. Storage improves reliability because electrical production can remain at a high level even when there are lulls in the wind or clouds decrease the solar energy striking the parabolic trough mirrors. The solar energy from Mojave Desert and wind energy in the major wind farm areas are not a good match to utility load during the winter in California, but if the number of wind farms were increased east of San Diego, then the utility renewable energy match would be improved (this is because the wind energy is highest during the winter in this area). Currently in California, wind electrical generation only contributes 1.8% of total electricity and solar electrical generation only contributes 0.2%. Combining wind farms and solar thermal power plants with storage would allow a large percentage of the electrical load in California to be met by wind and solar energy due to a better match with utility load than by either renewable resource separately.

14 SOLAR ENERGY↗

Solar multiple optimization for a solar-only thermal power plant, using oil as heat transfer fluid in the parabolic trough collectors

Usual size of parabolic trough solar thermal plants being built at present is approximately 50 MW{sub e}. Most of these plants do not have a thermal storage system for maintaining the power block performance at nominal conditions during long non-insolation periods. Because of that, a proper solar field size, with respect to the electric nominal power, is a fundamental choice. A too large field will be partially useless under high solar irradiance values whereas a small field will mainly make the power block to work at part-load conditions. This paper presents an economic optimization of the solar multiple for a solar-only parabolic trough plant, using neither hybridization nor thermal storage. Five parabolic trough plants have been considered, with the same parameters in the power block but different solar field sizes. Thermal performance for each solar power plant has been featured, both at nominal and part-load conditions. This characterization has been applied to perform a simulation in order to calculate the annual electricity produced by each of these plants. Once annual electric energy generation is known, levelized cost of energy (LCOE) for each plant is calculated, yielding a minimum LCOE value for a certain solar multiple value within the range considered. (author)

14 SOLAR ENERGY↗

Optimization of Cooling Water Flow Rate in Nuclear and Thermal Power Plants Based on a Mathematical Model of Cooling Systems{sup 1}

A mathematical model and algorithms are proposed for automatic calculation of the optimum flow rate of cooling water in nuclear and thermal power plants with cooling systems of arbitrary complexity. An unlimited number of configuration and design variants are assumed with the possibility of obtaining a result for any computational time interval, from monthly to hourly. The structural solutions corresponding to an optimum cooling water flow rate can be used for subsequent engineering-economic evaluation of the best cooling system variant. The computerized mathematical model and algorithms make it possible to determine the availability and degree of structural changes for the cooling system in all stages of the life cycle of a plant.

42 ENGINEERING↗

Solar Thermal Power Plant, Assembly

This assembly process apportions the construction, installation, and operations requirements of equipment and materials used in the assembly of a solar thermal power plant. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=E2C74A9A-2115-49E2-964E-72131B2B26FA

14 SOLAR ENERGY↗

Tax Revenue and Job Benefits from Solar Thermal Power Plants in Nye County

The objective of this report is to establish a common understanding of the financial benefits that the County will receive as solar thermal power plants are developed in Amargosa Valley. Portions of the tax data and job estimates in the report were provided by developers Solar Millennium and Abengoa Solar in support of the effort. It is hoped that the resulting presented data will be accepted as factual reference points for the ensuing debates and financial decisions concerning these development projects.

Kuver, Walt↗

Dynamic Human-in-the-Loop Simulated Nuclear Power Plant Thermal Dispatch System Demonstration and Evaluation Study

An Idaho National Laboratory research team performed a human-in-the-loop study with two formerly licensed retired operators to evaluate thermal power dispatch operations supported by the modified GSE Systems GPWR plant simulator. Virtual representations of the analog control panels were presented on touch-screen bays configured to mimic the control room layout in the newly renovated Human Systems Simulation Laboratory. The operators performed 15 scenarios covering normal evolutions to transition the plant from full turbine operation to joint turbine and thermal power dispatch operations in addition to transient response scenarios induced with simulated faults to evaluate the impact of thermal power dispatch system on operator and plant responses. A prototype human-system interface (HSI) was developed and displayed in tandem with the virtual analog panels to support the operators executing the procedurally drive evolutions and transient responses. An interdisciplinary team of operations experts, nuclear engineers, and human factors experts observed the operators performing the scenarios to evaluate the operations. Only a preliminary analysis of the results has been performed. The full analysis will be shared in a milestone report scheduled for release at the end of September; however, some high-level conclusions were readily available. Two high level findings for the system design were captured in the study. The manual control supported by the HSI to transition from standard operations to thermal power dispatch operation imposed a considerable amount of workload on the operators due to tedious manual valve manipulations and system monitoring required to verify their intended effect. An additional operator would be required in the control room to support the daily evolution. Automatic control for the transition was deemed a requirement for plant adoption without imposing additional staffing costs. The second finding was the necessity for an automatic thermal power dispatch system trip isolation function linked to a turbine and reactor trip signal. The operators completed scenarios with automatic isolation functionality and manually required actuation of the thermal power dispatch system. The operator response was sufficiently slower in the manual trip condition, such that operators were unable to manually actuate key post trip safety functions an indicate a degraded control capability that should be avoided. With an automatic trip signal little to no impact of the thermal power dispatch system was identified on the primary plant response and therefore the system could be readily and safely adopted. Together these two findings represent the need to support the adoption of thermal power dispatch capability into existing operations by leveraging automation to augment any additional operator tasking required to control and monitor an additional system beyond existing operations.

99 GENERAL AND MISCELLANEOUS↗

The impact of climate policies on the operation of a thermal power plant

Climate policy measures aimed at power markets influence the cost structure of producers and price patterns, and are therefore likely to influence the production decision of power plants, even in the short run. When power plants have costs related to starting and stopping, decisions on short-term production are intertemporal, and the conventional 'price vs. marginal cost' rule is not sufficient to predict production in thermal power plants. This paper analyzes how the optimal production decision is influenced by climate policies: namely, CO{sub 2} trading mechanisms, the expansion of renewables and the interaction between these policies. The main result is that higher power price variation (as a result of increased wind power production) makes the thermal power producer less flexible, but the effect on emissions is ambiguous. A CO{sub 2} cost (as a result of an emission trading system) increases the flexibility of the producer and the operation decision resembles the conventional 'price vs. marginal cost' rule more. This implies lower emissions. However, when the CO{sub 2} price is coupled with higher power price variation, the positive effects may be reversed since the two policies have opposing effects.

20 FOSSIL-FUELED POWER PLANTS↗

Modeling and Simulating Diffused Aeration for Hydrogen Removal from Expansion Tanks of Parabolic Trough Solar Thermal Power Plants

High-temperature decomposition of organic heat transfer fluids (HTFs) can cause hydrogen build-up in the receiver annulus of parabolic trough power plants. This build-up increases the receiver thermal losses and results in a decline in power output. Prior work has shown that removal of hydrogen from the expansion tank can be an effective mitigation strategy. This paper presents a modeling methodology and simulation results for passive and diffused aeration removal of hydrogen from the expansion tank. Focus is on estimating the mass transfer of hydrogen from the HTF into the headspace gas across the surface and bubble liquid/gas interfaces. Simulations for the operation conditions and expansion tank geometry of the Nevada Solar One power plant (located near Las Vegas, Nevada, USA) show that passive removal (surface mass transfer only) may be sufficient to obtain hydrogen removal rates of 1.7 x 10-4 mol/s (minimal removal rate necessary). A diffused aeration system (surface plus bubble mass transfer) with gas injection volume rates up to 100 L/s may be necessary to obtain a hydrogen removal rate of 2.0 x 10-4 mol/s (optimal removal rate).

14 SOLAR ENERGY↗

Thermal Energy Storage and its Potential Applications in Solar Thermal Power Plants and Electricity Storage

With the rapid growth of renewable power generation, economically storing large quantities of solar- and wind-generated electricity may become as important as renewable power itself. The combination of renewable power generation and energy storage can overcome the variability of renewable power generation alone and create the opportunity for renewable generation to provide base-load electricity.For peak power usage, the integration of renewable power and storage of excess electricity has several significant and positive impacts: expanding the renewable energy portion of total electricity generation, improving the peak-load response, and coordinating the electricity supply and demand over the grid. Several energy storage approaches exist, with mechanical, chemical, and electricalmethods either in use now or being developed. Comparing their efficiencies as well as their economic uses for different scales and applications helps determine the right technology for the right purpose. This paper will study the possibility of using thermal energy storage as a means for electricity storage, and compare it to other energy storage methods including batteries, flywheels, compressed air, and pumped hydropower.

14 SOLAR ENERGY↗