Search NASASearch

SEARCH · Search NASA

Results for “THERMIONIC CATHODE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Direct evidence of low work function on SrVO 3 cathode using thermionic electron emission microscopy and high-field ultraviolet photoemission spectroscopy

Perovskite SrVO 3 has recently been proposed as a novel electron emission cathode material. Density functional theory (DFT) calculations suggest multiple low work function surfaces, and recent experimental efforts have consistently demonstrated effective work functions of ~2.7 eV for polycrystalline samples, both results suggesting, but not directly confirming, that some fraction of even lower work function surface is present. In this work, thermionic electron emission microscopy (ThEEM) and high-field ultraviolet photoemission spectroscopy (UPS) are used to study the local work function distribution and measure the work function of a partially oriented- (110)-SrVO 3 perovskite oxide cathode surface. Our results show direct evidence of low work function patches of about 2.0 eV on the cathode surface, with a corresponding onset of observable thermionic emission at 750 °C. We hypothesize that, in our ThEEM and UPS experiments, the high applied electric field suppresses the patch field effect, enabling the direct measurement of local work functions. This measured work function of 2.0 eV is comparable to the previous DFT-calculated work function values of the SrVO-terminated (110) SrVO 3 surface (2.3 eV) and SrO-terminated (100) surface (1.9 eV). The measured 2.0 eV value is also much lower than the work function for the (001) LaB 6 single crystal cathode (~2.7 eV) and comparable to the effective work function of B-type dispenser cathodes (~2.1 eV). If SrVO 3 thermionic emitters can be engineered to access domains of this low 2.0 eV work function, they have the potential to significantly improve thermionic emitter-based technologies.

36 MATERIALS SCIENCE

Wavelength modulation laser-induced fluorescence for plasma characterization

Laser-Induced Fluorescence (LIF) spectroscopy is an essential tool for probing ion and atom velocity distribution functions (VDFs) in complex plasmas. VDFs carry information about the kinetic properties of species that is critical for plasma characterization. Accurate interpretation of these functions is challenging due to factors such as multicomponent distributions, broadening effects, and background emissions. Our research investigates the use of Wavelength Modulation (WM) LIF to enhance the sensitivity of VDF measurements. Unlike standard Amplitude Modulation (AM) methods, WM–LIF measures the derivative of the LIF signal. This approach makes variations in VDF shape more pronounced. VDF measurements with WM–LIF were investigated with both numerical modeling and experimental measurements. The developed model enables the generation of both WM and AM signals, facilitating comparative analysis of fitting outcomes. Experiments were conducted in a weakly collisional argon plasma with magnetized electrons and non-magnetized ions. Measurements of the argon ion VDFs employed a narrow-band tunable diode laser, which scanned the 4p 4 D 7/2 –3d 4 F 9/2 transition centered at 664.553 nm in vacuum. A lock-in amplifier detected the second harmonic WM signal, which was generated by modulating the laser wavelength with an externally controlled piezo-driven mirror of the diode laser. Finally, our findings indicate that the WM–LIF signal is more sensitive to fitting parameters, allowing for better identification of VDF parameters such as the number of distribution components, their temperatures, and velocities. In addition, WM–LIF can serve as an independent method to verify AM measurements and is particularly beneficial in environments with substantial light noise or background emissions, such as those involving thermionic cathodes and reflective surfaces.

47 OTHER INSTRUMENTATION

Efficient continuous-wave normal conducting accelerator for industrial applications

A normal conducting, high power, high efficiency copper linear accelerator prototype is being developed for industrial applications. The system will be powered by low-cost high-efficiency magnetron RF sources and will use a gridded thermionic cathode electron gun. Leveraging the significant accelerator expertise at JLab and industry partners, these technologies will be combined to deliver high-power (>100 kW) electron beams with energies of 1 MeV or higher that are cost-effective to produce and operate. The design is modular such that energy and power can be increased by adding additional sections as required. The status of the design, prototype fabrication and plans for a beam demonstration at JLab are described.

Accelerator Physics

LLNL FESP Theory Highlights: November 2024

This talk presented a refined understanding of plasma-facing thermionic emitter cathodes by examining the limitations of the conventional space charge-limited model, which overlooks ion trapping dynamics within the virtual cathode. While conventional theory distinguishes between temperature-limited and space charge-limited regimes based on electron current constraints, recent findings reveal that trapped ions can form a quasi-neutral "second plasma," expanding upstream and interacting with the primary plasma. These effects are amplified in non-planar geometries, such as cylindrical or spherical sheaths, where trapped ions create a positive feedback loop with the upstream plasma. To address these phenomena, a new "Aid-and-Compete" model was developed, offering insights into current enhancement and sheath mode transitions relevant for plasma devices, including emissive cathodes in electric propulsion, fusion applications, thin film deposition systems, and plasma diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Wehnelt photoemission in an ultrafast electron microscope: Stability and usability

We tested and compared the stability and usability of three different cathode materials and configurations in a thermionic-based ultrafast electron microscope: (1) on-axis thermionic and photoemission from a custom 100 μm diameter LaB 6 source with a graphite guard ring, (2) off-axis photoemission from the Ni aperture surface of the Wehnelt electrode, and (3) on-axis thermionic and photoemission from a custom 200 μm diameter polycrystalline Ta source. For each cathode type and configuration, including the Ni Wehnelt aperture, we illustrate how the photoelectron beam-current stability is deleteriously impacted by simultaneous cooling of the source following thermionic heating. Furthermore, we demonstrate usability via collection of parallel- and convergent-beam electron diffraction patterns and by formation of the optimum probe size. We find that usability of the off-axis Ni Wehnelt-aperture photoemission is at least comparable to on-axis LaB 6 thermionic emission, as well as to on-axis photoemission [the heretofore conventional approach to ultrafast electron microscopy (UEM) in thermionic-based instruments]. However, the stability and achievable beam currents for off-axis photoemission from the Wehnelt aperture were superior to that of the other cathode types and configurations, regardless of the electron-emission mechanism. Beam-current stability for this configuration was found to be ±1% (one standard deviation from the mean) for 70 min (longest duration tested), and steady-state beam current was reached within the sampling-time resolution used here (~1 s) for 15 pA beam currents (i.e., 460 electrons per packet for a 200 kHz repetition rate). Repeatability and robustness of the steady-state condition were also found to be within ±1% of the mean. We discuss the implications of these findings for UEM imaging and diffraction experiments, for pulsed-beam damage measurements, and for practical switching between optimum conventional TEM and UEM operation within the same instrument.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC

Theory of the thermionic current beyond the traditional space charge limit enabled by trapped ions in the virtual cathode

We show that trapped ions in virtual cathode potential wells can raise the transmitted current of emitted electrons into a plasma much closer to the full emission than is predicted by cathode sheath theories without trapped ions. The transmitted current is controlled by the well barrier voltage, which must adjust to balance the creation of low-energy ions within the well, and their loss. Our model considers the case of a plasma-facing cathode where trapped ions are created passively via charge-exchange collisions and lost passively via thermal leakage over the well. We quantify these rates and estimate the current in terms of system parameters for thermionic emission into a plasma with several cathode geometries. A general prediction is that the current as a function of emitted flux does not saturate at the traditional space charge limit (the onset of a well) but can reach far higher values until the trapped ion balance breaks down, causing instability. The maximum stable current depends on parameters but in principle can be arbitrarily high if active techniques are used to manipulate the trapped ion balance. We conclude that major improvements in plasma technologies with hot cathodes might be achieved by optimizing the current enhancement enabled by trapped ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Over 600 V Lateral AlN-on-AlN Schottky Barrier Diodes with Ultra-Low Ideality Factor

Abstract This letter reports the demonstration of lateral AlN Schottky barrier diodes (SBDs) on single-crystal AlN substrates by metalorganic CVD (MOCVD) with an ultra-low ideality factor ( η ) of 1.65, a high Schottky barrier height of 1.94 eV, a breakdown voltage ( BV ) of 640 V, and a record high normalized BV by the anode-to-cathode distance. The device current was dominated by thermionic emission, while most previously reported AlN SBDs suffered from defect-induced current with higher η (>4). This work represents a significant step towards high-performance ultra-wide bandgap AlN-based high-voltage and high-power devices.

Physics

Influence of Photoemission Geometry on Timing and Efficiency in 4D Ultrafast Electron Microscopy

Broader adoption of 4D ultrafast electron microscopy (UEM) for the study of chemical, materials, and quantum systems is being driven by development of new instruments as well as continuous improvement and characterization of existing technologies. Perhaps owing to the still-high barrier to entry, the full range of capabilities of laser-driven 4D UEM instruments has yet to be established, particularly when operated at extremely low beam currents (~fA). Accordingly, with an eye on beam stability, we have conducted particle tracing simulations of unconventional off-axis photoemission geometries in a UEM equipped with a thermionic-emission gun. Specifically, we have explored the impact of experimentally adjustable parameters on the time-of-flight (TOF), the collection efficiency (CE), and the temporal width of ultrashort photoelectron packets. The adjustable parameters include the Wehnelt aperture diameter (DW), the cathode set-back position (Ztip), and the position of the femtosecond laser on the Wehnelt aperture surface relative to the optic axis (Rphoto). Notable findings include significant sensitivity of TOF to DW and Ztip, as well as non-intuitive responses of CE and temporal width to varying Rphoto. As a means to improve accessibility, practical implications and recommendations are emphasized wherever possible.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Two Mechanisms Limiting the Emitted Electron Current from a Cathode to an Anode

It is known that the current of emitted electrons flowing through a plasma can saturate upon formation of a potential well adjacent to the cathode (the “space charge effect”). Here, we demonstrate another saturation mechanism that will often set a more restrictive limit on the global current. When “backflow saturation” occurs, the cathode sheath weakens to allow emitted electrons that already entered the plasma to backflow to the cathode. This effect could not be captured by studies modelling the cathode sheath by itself because its origin is coupled to processes in the interior plasma and anode sheath. By modeling a full plasma diode, we show that depending on conditions the global current can be limited in four ways; by backflow alone, by space charge alone, by both mechanisms in a stable cooperative form, or by both in a competing oscillatory form. Published by the American Physical Society 2025

Laboratory plasma