Thermoluminescence and phototransferred thermoluminescence dosimetry on mobile phone protective touchscreen glass

Thermoluminescence and phototransferred thermoluminescence measurements of protective glass from smartphones are described. Samples of Gorilla Glass were examined from nine different manufacturers and 40 different phone models. Additionally, 12 glasses believed to be original equipment manufacturer replacements, as well as three glass samples from U.S. finishers, were also studied. Altogether, 99 different Gorilla Glass samples were examined. The radiation-induced thermoluminescence signal produced glow curve shapes specific to the Gorilla Glass generations and could be used to distinguish between them. A background thermoluminescence (and phototransferred thermoluminescence) signal was found in all unirradiated samples. Its intensity and shape were found to be dependent on the Gorilla Glass generation, phone manufacturer, and phone model. The background signal was demonstrated to be produced by ultraviolet light exposure; the shape of the background signal was able to be reproduced by the combined exposure to a broad-spectrum solar simulator and a 302 nm ultraviolet light source. The background signal intensity was found to vary with the location from which it was taken on the glass. It was also found to be dependent on the depth within the Gorilla Glass due to absorption of the ultraviolet light as it traversed the medium. Removal of the glasses’ surface layers was found to be an inadequate method for removing the background signal. In some samples, the background signal intensity was large enough to significantly contribute to the total thermoluminescence (and phototransferred thermoluminescence) signal; therefore, a matrix deconvolution method was introduced to separate the background signal and radiation-induced signal. This method was found to enable dose reconstruction using the radiation-induced signal alone.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-222: Investigation of Pre and Post Irradiation Fading of the TLD100 Thermoluminescence Dosimetry for Photon Beams

Purpose: The pre-irradiation and post-irradiation fading of the Thermoluminescense dosimeter signals were investigated in this study. Methods: Two groups of TLD chips with pre-determined ECC values were used in this study. The two groups were divided into 6 series, each composing of 5 TLD chips.The first group was used for pre-irradiation fading. 5 TLDs were exposed to a known amount of radiation from Cs-137 source, and were read out the next day. After seven days, the other 5 TLDs were exposed to the same amount of radiation and were read out after a day. The other series of 5 TLDs were also exposed after 7,19,28, 59, and 90 days, and were read out a day after irradiation. The loss in TLD signal were obtained for all the above cases. The second group, was used for postirradiation fading. All the TLDs of this group were exposed to a known amount of radiation from Cs-137 source. The 6 series composed of 5 TLDs were read out after 1,7,19,28,59, and 90 days. The above-mentioned procedures for obtaining pre-irradiation, and post-irradiation fading were performed for three storage temperatures (25°C, 4°C, and −18°C). Results: According to the results obtained in this study, in case of pre-irradiation fading study, the signal losses after 90 days are 12%, 24%, and 17% for 25°C, 4°C, and −18°C respectively. In case of post-irradiation fading study, the sensitivity losses after 90 days are 25%, 216%, and 20% for 25°C, 4°C, and −18°C respectively. Conclusion: The results indicate that the optimized time between exposing and reading out, and also the optimized time between annealing and exposing is 1 day.The reduction of Storage temperature will reduce the post-irradiation fading, While temperature reduction does not have any effect on pre-irradiation fading.

60 APPLIED LIFE SCIENCES↗

Hydrothermally synthesized barium fluoride nanocubes for thermoluminescence dosimetry

In this work, we report a hydrothermally synthesized Dy doped BaF{sub 2} (BaF{sub 2}:Dy) nanocubes and its Thermoluminescence studies. The synthesized BaF{sub 2}:Dy samples was found to posses FCC structure and having average size ~ 60-70 nm, as revealed through X-Ray Diffraction. Cubical morphology having size ~90 nm was observed from TEM analysis. The {sup 60}Co γ- ray irradiated BaF{sub 2}:Dy TL dosimetric experiments shows a pre-dominant single glow peak at 153 °C, indicating a single level trap present as a metastable state. Furthermore, BaF{sub 2}:Dy nanophosphor shows a sharp linear response from 10 Gy to 3 kGy, thus it can be applicable as a gamma dosimeter.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Dosimetric characterization of a {sup 131}Cs brachytherapy source by thermoluminescence dosimetry in liquid water

Dosimetry measurements of a {sup 131}Cs brachytherapy source have been performed in liquid water employing thermoluminescence dosimeters. A search of the literature reveals that this is the first time a complete set of dosimetric parameters for a brachytherapy ''seed'' source has been measured in liquid water. This method avoids the medium correction uncertainties introduced by the use of water-equivalent plastic phantoms. To assure confidence in the results, four different sources were employed for each parameter measured, and measurements were performed multiple times. The measured dosimetric parameters presented here are based on the AAPM Task Group 43 formalism. The dose-rate constant measured in liquid water was (1.063{+-}0.023) cGy h{sup -1} U{sup -1} and was based on the air-kerma strength standard for this source established by the National Institute of Standards and Technology. Measured values for the 2D anisotropy function and the radial dose function are presented.

61 RADIATION PROTECTION AND DOSIMETRY↗

Thermoluminescence dosimetry measurements of brachytherapy sources in liquid water

Radiation therapy dose measurements are customarily performed in liquid water. The characterization of brachytherapy sources is, however, generally based on measurements made with thermoluminescence dosimeters (TLDs), for which contact with water may lead to erroneous readings. Consequently, most dosimetry parameters reported in the literature have been based on measurements in water-equivalent plastics, such as Solid Water. These previous reports employed a correction factor to transfer the dose measurements from a plastic phantom to liquid water. The correction factor most often was based on Monte Carlo calculations. The process of measuring in a water-equivalent plastic phantom whose exact composition may be different from published specifications, then correcting the results to a water medium leads to increased uncertainty in the results. A system has been designed to enable measurements with TLDs in liquid water. This system, which includes jigs to support water-tight capsules of lithium fluoride in configurations suitable for measuring several dosimetric parameters, was used to determine the correction factor from water-equivalent plastic to water. Measurements of several {sup 125}I and {sup 131}Cs prostate brachytherapy sources in liquid water and in a Solid Water phantom demonstrated a correction factor of 1.039{+-}0.005 at 1 cm distance. These measurements are in good agreement with a published value of this correction factor for an {sup 125}I source.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermoluminescent dosimetry for the Apollo 16 microbial response to space environment experiment (M191)

Lithium fluoride thermoluminescent chips were used to provide an integrated dose from the broad spectrum of ionizing radiation to the Microbial Response to Space Environment Experiment (M191). The chips were positioned in the flight hardware to provide data on ionizing radiation within specific volume segments. A uniform radiation dose of 4.8 x 0.001 plus or minus 2 x 0.0001 joule/kg resulted.

Brown, R. D.↗

Thermoluminescent dosimetry for LDEF experiment M0006

Experiment M0006 on the Long Duration Exposure Facility had as its objective the investigation of space radiation effects on various electronic and optical components, as well as on seed germination. The Grumman Corporate Research Center provided the radiation dosimetric measurements for M0006, comprising the preparation of thermoluminescent dosimeters (TLD) and the subsequent measurement and analysis of flight exposed and control samples. In addition, various laboratory exposures of TLD's with gamma rays and protons were performed to obtain a better understanding of the flight exposures.

Chang, J. Y.↗

Measurement of differential proton spectra onboard the Space Shuttle using a thermoluminescent dosimetry system

An experimental technique that permits the extraction of orbit-averaged, differential energy spectra of trapped radiation belt protons using simple passive detectors is described. An inversion technique is used for the data analysis. The basic principle of the described system is measurement of the energy deposited in six thermoluminescent (TLD) detector assemblies behind various spherical absorbers. The technique has been applied to a detector assembly flown on four Shuttle flights. Although severe restraints were placed on the flight package, the differential energy spectra derived from these measurements are in good agreement with analytical results using a modified trapped proton environment model. The technique shows good promise for measuring the spectra in low inclination orbits where the flux of high energy galactic cosmic rays protons is small. Modifications to the detector assembly to improve the accuracy and to extend the range of the system to higher energies are suggested.

STS-51J Shuttle Project↗

The influence of neutron contamination on dosimetry in external photon beam radiotherapy

Purpose: Photon fields with energies above ∼7 MeV are contaminated by neutrons due to photonuclear reactions. Their influence on dosimetry—although considered to be very low—is widely unexplored. Methods: In this work, Monte Carlo based investigations into this issue performed with FLUKA and EGSNRC are presented. A typical Linac head in 18 MV-X mode was modeled equivalently within both codes. EGSNRC was used for the photon and FLUKA for the neutron production and transport simulation. Water depth dose profiles and the response of different detectors (Farmer chamber, TLD-100, TLD-600H, and TLD-700H chip) in five representative depths were simulated and the neutrons’ impact (neutron absorbed dose relative to photon absorbed dose) was calculated. To take account of the neutrons’ influence, a theoretically required correction factor was defined and calculated for five representative water depths. Results: The neutrons’ impact on the absorbed dose to water was found to be below 0.1% for all depths and their impact on the response of the Farmer chamber and the TLD-700H chip was found to be even less. For the TLD-100 and the TLD-600H chip it was found to be up to 0.3% and 0.7%, respectively. The theoretical correction factors to be applied to absorbed dose to water values measured with these four detectors in a depth different from the reference/calibration depth were calculated and found to be below 0.05% for the Farmer chamber and the TLD-700H chip, but up to 0.15% and 0.35% for the TLD-100 and TLD-600H chips, respectively. In thermoluminescence dosimetry the neutrons’ influence (and therefore the additional inaccuracy in measurement) was found to be higher for TLD materials whose {sup 6}Li fraction is high, such as TLD-100 and TLD-600H, resulting from the thermal neutron capture reaction on {sup 6}Li. Conclusions: The impact of photoneutrons on the absorbed dose to water and on the response of a typical ionization chamber as well as three different types of TLD chips was quantified and was as expected found to be very low relative to that of the primary photons. For most practical reasons the neutrons’ influence on dosimetry might be neglected while for absolute precise thermoluminescence dosimetry in high energy photon fields, the use of TLD-700H (<0.03% {sup 6}Li) instead of the commonly used TLD-100 (7.4% {sup 6}Li) or even the extra neutron sensitive TLD-600H is recommended (95.6% {sup 6}Li) due to the additional inaccuracy in measurement for TLD materials with a high {sup 6}Li fraction.

07 ISOTOPE AND RADIATION SOURCES↗

Ambient Dose Equivalent in S. Paulo and Bauru cities

The Laboratory of Dosimetry (Institute of Physics, University of S. Paulo) performs since 1981 the external individual monitoring of workers exposed to X and gamma rays based on thermoluminescent dosimetry (TLD). Personal dose equivalent refers only to the exposure of workers due to the working activities, and the dose due to background radiation, also measured with TLD, must be subtracted to evaluate it. A compilation of ambient dose equivalent was done to evaluate the dose due to the background radiation in the work places, and also to contribute to the knowledge of the level of indoor radiation to which the public is exposed.

61 RADIATION PROTECTION AND DOSIMETRY↗

A comparison of TPS and different measurement techniques in small-field electron beams

In recent years, small-field electron beams have been used for the treatment of superficial lesions, which requires small circular fields. However, when using very small electron fields, some significant dosimetric problems may occur. In this study, dose distributions and outputs of circular fields with dimensions of 5 cm and smaller, for nominal energies of 6, 9, and 15 MeV from the Siemens ONCOR Linac, were measured and compared with data from a treatment planning system using the pencil-beam algorithm in electron beam calculations. All dose distribution measurements were performed using the Gafchromic EBT film; these measurements were compared with data that were obtained from the Computerized Medical Systems (CMS) XiO treatment planning system (TPS), using the gamma-index method in the PTW VeriSoft software program. Output measurements were performed using the Gafchromic EBT film, an Advanced Markus ion chamber, and thermoluminescent dosimetry (TLD). Although the pencil-beam algorithm is used to model electron beams in many clinics, there is no substantial amount of detailed information in the literature about its use. As the field size decreased, the point of maximum dose moved closer to the surface. Output factors were consistent; differences from the values obtained from the TPS were, at maximum, 42% for 6 and 15 MeV and 32% for 9 MeV. When the dose distributions from the TPS were compared with the measurements from the Gafchromic EBT films, it was observed that the results were consistent for 2-cm diameter and larger fields, but the outputs for fields of 1-cm diameter and smaller were not consistent. In CMS XiO TPS, calculated using the pencil-beam algorithm, the dose distributions of electron treatment fields that were created with circular cutout of a 1-cm diameter were not appropriate for patient treatment and the pencil-beam algorithm is not convenient for monitor unit (MU) calculations in electron dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-SPS-04: Dosimetric Evaluation of the Dose Calculation Accuracy of Different Algorithms for Two Different Treatment Techniques During Whole Breast Irradiation

Purpose: In this study, dosimetric comparison of field in field (FIF) and intensity modulated radiation therapy (IMRT) techniques used for treatment of whole breast radiotherapy (WBRT) were made. The dosimetric accuracy of treatment planning system (TPS) for Anisotropic Analytical Algorithm (AAA) and Acuros XB (AXB) algorithms in predicting PTV and OAR doses was also investigated. Methods: Two different treatment planning techniques of left-sided breast cancer were generated for rando phantom. FIF and IMRT plans were compared for doses in PTV and OAR volumes including ipsilateral lung, heart, left ascending coronary artery, contralateral lung and the contralateral breast. PTV and OARs doses and homogeneity and conformality indexes were compared between two techniques. The accuracy of TPS dose calculation algorithms was tested by comparing PTV and OAR doses measured by thermoluminescent dosimetry with the dose calculated by the TPS using AAA and AXB for both techniques. Results: IMRT plans had better conformality and homogeneity indexes than FIF technique and it spared OARs better than FIF. While both algorithms overestimated PTV doses they underestimated all OAR doses. For IMRT plan, PTV doses, overestimation up to 2.5 % was seen with AAA algorithm but it decreased to 1.8 % when AXB algorithm was used. Based on the results of the anthropomorphic measurements for OAR doses, underestimation greater than 7 % is possible by the AAA. The results from the AXB are much better than the AAA algorithm. However, underestimations of 4.8 % were found in some of the points even for AXB. For FIF plan, similar trend was seen for PTV and OARs doses in both algorithm. Conclusion: When using the Eclipse TPS for breast cancer, AXB the should be used instead of the AAA algorithm, bearing in mind that the AXB may still underestimate all OAR doses.

60 APPLIED LIFE SCIENCES↗

Comparison of Various Radiation Therapy Techniques in Breast Cancer Where Target Volume Includes Mammaria Interna Region

In breast cancer radiotherapy, the internal mammary lymphatic chain is treated in the target volume in a group of patients with high-risk criteria. Because of the variability of the anatomic region and structures in the irradiation field, there are a number of different techniques in breast radiotherapy. While irradiating the target volume, we also consider minimizing the dose to critical structures such as heart, lung, and contralateral breast tissue. In this study, we evaluated the dose distribution of different radiotherapy techniques in patients with left-sided breast cancer who had breast-conserving surgery. A three-dimensional computerized planning system (3DCPS) was used for each patient to compare wide-field, oblique photon-electron, and perpendicular photon-electron techniques in terms of dose homogeneities in the target volume; the doses received by the contralateral breast, heart, and lung; and the coverage of the internal mammary chain. Data from 3DCPS were controlled by the Rando-phantom and thermoluminescence dosimetry. Critical structures were irradiated with acceptable dose percentages in addition to the internal mammary chain with both wide-field and photon-electron techniques. We detected more frequent hot spots in the oblique photon-electron technique than in the other techniques, and this situation necessitated changing the junctions. The wide-field technique was easy to perform and exposed less radiation dose to the heart than photon-electron techniques. In conclusion, we suggest the use of the wide-field technique in breast irradiation when the internal mammary area is in the target volume.

61 RADIATION PROTECTION AND DOSIMETRY↗

Is radiography justified for the evaluation of patients presenting with cervical spine trauma?

Conventional radiography has been for decades the standard method of evaluation for cervical spine trauma patients. However, currently available helical multidetector CT scanners allow multiplanar reconstruction of images, leading to increased diagnostic accuracy. The purpose of this study was to determine the relative benefit/risk ratio between cervical spine CT and cervical spine radiography and between cervical spine CT and cervical spine radiography, followed by CT as an adjunct for positive findings. A decision analysis model for the determination of the optimum imaging technique was developed. The sensitivity and specificity of CT and radiography were obtained by dedicated meta-analysis. Lifetime attributable risk of mortal cancer from CT and radiography was calculated using updated organ-specific risk coefficients and organ-absorbed doses. Patient organ doses from radiography were calculated using Monte Carlo techniques, simulated exposures performed on an anthropomorphic phantom, and thermoluminescence dosimetry. A prospective patient study was performed regarding helical CT scans of the cervical spine. Patient doses were calculated based on the dose-length-product values and Monte Carlo-based CT dosimetry software program. Three groups of patient risk for cervical spine fracture were incorporated in the decision model on the basis of hypothetical trauma mechanism and clinical findings. Radiation effects were assessed separately for males and females for four age groups (20, 40, 60, and 80 yr old). Effective dose from radiography amounts to 0.050 mSv and from a typical CT scan to 3.8 mSv. The use of CT in a hypothetical cohort of 10{sup 6} patients prevents approximately 130 incidents of paralysis in the low risk group (a priori fracture probability of 0.5%), 500 in the moderate risk group (a priori fracture probability of 2%), and 5100 in the high risk group (a priori fracture probability of 20%). The expense of this CT-based prevention is 15-32 additional radiogenic lethal cancer incidents. According to the decision model calculations, the use of CT is more favorable over the use of radiography alone or radiography with CT by a factor of 13, for low risk 20 yr old patients, to a factor of 23, for high risk patients younger than 80 yr old. The radiography/CT imaging strategy slightly outperforms plain radiography for high and moderate risk patients. Regardless of the patient age, sex, and fracture risk, the higher diagnostic accuracy obtained by the CT examination counterbalances the increase in dose compared to plain radiography or radiography followed by CT only for positive radiographs and renders CT utilization justified and the radiographic screening redundant.

61 RADIATION PROTECTION AND DOSIMETRY↗

A photon spectrometric dose-rate constant determination for the Advantage Pd-103 brachytherapy source

Purpose: Although several dosimetric characterizations using Monte Carlo simulation and thermoluminescent dosimetry (TLD) have been reported for the new Advantage Pd-103 source (IsoAid, LLC, Port Richey, FL), no AAPM consensus value has been established for the dosimetric parameters of the source. The aim of this work was to perform an additional dose-rate constant ({Lambda}) determination using a recently established photon spectrometry technique (PST) that is independent of the published TLD and Monte Carlo techniques. Methods: Three Model IAPD-103A Advantage Pd-103 sources were used in this study. The relative photon energy spectrum emitted by each source along the transverse axis was measured using a high-resolution germanium spectrometer designed for low-energy photons. For each source, the dose-rate constant was determined from its emitted energy spectrum. The PST-determined dose-rate constant ({sub PST}{Lambda}) was then compared to those determined by TLD ({sub TLD}{Lambda}) and Monte Carlo ({sub MC}{Lambda}) techniques. A likely consensus {Lambda} value was estimated as the arithmetic mean of the average {Lambda} values determined by each of three different techniques. Results: The average {sub PST}{Lambda} value for the three Advantage sources was found to be (0.676{+-}0.026) cGyh{sup -1} U{sup -1}. Intersource variation in {sub PST}{Lambda} was less than 0.01%. The {sub PST}{Lambda} was within 2% of the reported {sub MC}{Lambda} values determined by PTRAN, EGSnrc, and MCNP5 codes. It was 3.4% lower than the reported {sub TLD}{Lambda}. A likely consensus {Lambda} value was estimated to be (0.688{+-}0.026) cGyh{sup -1} U{sup -1}, similar to the AAPM consensus values recommended currently for the Theragenics (Buford, GA) Model 200 (0.686{+-}0.033) cGyh{sup -1} U{sup -1}, the NASI (Chatsworth, CA) Model MED3633 (0.688{+-}0.033) cGyh{sup -1} U{sup -1}, and the Best Medical (Springfield, VA) Model 2335 (0.685{+-}0.033) cGyh{sup -1} U{sup -1} {sup 103}Pd sources. Conclusions: An independent {Lambda} determination has been performed for the Advantage Pd-103 source. The {sub PST}{Lambda} obtained in this work provides additional information needed for establishing a more accurate consensus {Lambda} value for the Advantage Pd-103 source.

61 RADIATION PROTECTION AND DOSIMETRY↗

Assessment of Out-of-Field Doses in Radiotherapy of Brain Lesions in Children

Purpose: To characterize the out-of-field doses in pediatric radiotherapy and to identify simple methods by which out-of-field dose might be minimized, with a view to reducing the risk of secondary cancers. Methods and Materials: With the aim of characterizing the peripheral doses under different treatment conditions, the dose measurements in an anthropomorphic child phantom were taken in various organs and critical structures outside the primary field using thermoluminescent dosimetry. The doses from a Varian 600C and Varian Trilogy linear accelerator, both at 6 MV, were investigated. Results: Larger field sizes have been shown to result in greater peripheral doses close to the primary beam, with the difference becoming less significant at large distances, indicating that most of out-of-field doses result from head leakage and collimator scatter >40 cm from the primary field. The use of lead shields has been shown to reduce the absorbed dose resulting from leakage. Aligning the craniocaudal axis of the patient with the x-plane of the collimator resulted in a dose reduction of 40%, for both machines. Out-of-field doses from the Varian Trilogy were shown to be approximately 40% greater than those from the 600C linear accelerator, despite being operated at the same energy. Conclusion: Out-of-field doses to pediatric patients can be minimized by using simple treatment options, such as using the single-energy mode linear accelerator rather than the multimode, orienting the couch and collimator such that the patient lies along the x-plane and avoiding fields directed along the trunk of the body.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient-specific radiation dose and cancer risk estimation in CT: Part I. Development and validation of a Monte Carlo program

Purpose: Radiation-dose awareness and optimization in CT can greatly benefit from a dose-reporting system that provides dose and risk estimates specific to each patient and each CT examination. As the first step toward patient-specific dose and risk estimation, this article aimed to develop a method for accurately assessing radiation dose from CT examinations. Methods: A Monte Carlo program was developed to model a CT system (LightSpeed VCT, GE Healthcare). The geometry of the system, the energy spectra of the x-ray source, the three-dimensional geometry of the bowtie filters, and the trajectories of source motions during axial and helical scans were explicitly modeled. To validate the accuracy of the program, a cylindrical phantom was built to enable dose measurements at seven different radial distances from its central axis. Simulated radial dose distributions in the cylindrical phantom were validated against ion chamber measurements for single axial scans at all combinations of tube potential and bowtie filter settings. The accuracy of the program was further validated using two anthropomorphic phantoms (a pediatric one-year-old phantom and an adult female phantom). Computer models of the two phantoms were created based on their CT data and were voxelized for input into the Monte Carlo program. Simulated dose at various organ locations was compared against measurements made with thermoluminescent dosimetry chips for both single axial and helical scans. Results: For the cylindrical phantom, simulations differed from measurements by -4.8% to 2.2%. For the two anthropomorphic phantoms, the discrepancies between simulations and measurements ranged between (-8.1%, 8.1%) and (-17.2%, 13.0%) for the single axial scans and the helical scans, respectively. Conclusions: The authors developed an accurate Monte Carlo program for assessing radiation dose from CT examinations. When combined with computer models of actual patients, the program can provide accurate dose estimates for specific patients.

60 APPLIED LIFE SCIENCES↗

A method of estimating conceptus doses resulting from multidetector CT examinations during all stages of gestation

Purpose: Current methods for the estimation of conceptus dose from multidetector CT (MDCT) examinations performed on the mother provide dose data for typical protocols with a fixed scan length. However, modified low-dose imaging protocols are frequently used during pregnancy. The purpose of the current study was to develop a method for the estimation of conceptus dose from any MDCT examination of the trunk performed during all stages of gestation. Methods: The Monte Carlo N-Particle (MCNP) radiation transport code was employed in this study to model the Siemens Sensation 16 and Sensation 64 MDCT scanners. Four mathematical phantoms were used, simulating women at 0, 3, 6, and 9 months of gestation. The contribution to the conceptus dose from single simulated scans was obtained at various positions across the phantoms. To investigate the effect of maternal body size and conceptus depth on conceptus dose, phantoms of different sizes were produced by adding layers of adipose tissue around the trunk of the mathematical phantoms. To verify MCNP results, conceptus dose measurements were carried out by means of three physical anthropomorphic phantoms, simulating pregnancy at 0, 3, and 6 months of gestation and thermoluminescence dosimetry (TLD) crystals. Results: The results consist of Monte Carlo-generated normalized conceptus dose coefficients for single scans across the four mathematical phantoms. These coefficients were defined as the conceptus dose contribution from a single scan divided by the CTDI free-in-air measured with identical scanning parameters. Data have been produced to take into account the effect of maternal body size and conceptus position variations on conceptus dose. Conceptus doses measured with TLD crystals showed a difference of up to 19% compared to those estimated by mathematical simulations. Conclusions: Estimation of conceptus doses from MDCT examinations of the trunk performed on pregnant patients during all stages of gestation can be made using the method developed in the current study.

61 RADIATION PROTECTION AND DOSIMETRY↗