Effect of Angle of Incidence of Second-Stage Vane Assembly on Third-Stage Compressor-Blade Vibration and Engine Performance
Strain-gages were used to measure blade vibrations causing failures in the third stage of a production 11-stage axial-flow compressor. After the serious third-stage vibration was detected, a series of investigations were conducted with second-stage vane assemblies of varying angles of incidence. Curves presented herein show the effect of varying the angle of incidence of second-stage vane assembly on third-stage rotor-blade vibration amplitude and engine performance. A minimum vibration amplitude was obtained without greatly affecting the engine performance with a second-stage vane assembly of 9deg. greater angle of incidence than the assembly normally furnished with the engine.