Search NASA⌕ Search

SEARCH · Search NASA

Results for “THOMSON SCATTERING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Simulated performance of the optical Thomson scattering diagnostic designed for the National Ignition Facility

An optical Thomson scattering diagnostic has been designed for the National Ignition Facility to characterize under-dense plasmas. We report on the design of the system and the expected performance for different target configurations. The diagnostic is designed to spatially and temporally resolve the Thomson scattered light from laser driven targets. The diagnostic will collect scattered light from a 50 × 50 × 200 μm volume. The optical design allows operation with different probe laser wavelengths. A deep-UV probe beam (λ{sub 0} = 210 nm) will be used to Thomson scatter from electron plasma densities of ∼5 × 10{sup 20} cm{sup −3} while a 3ω probe will be used for plasma densities of ∼1 × 10{sup 19} cm{sup −3}. The diagnostic package contains two spectrometers: the first to resolve Thomson scattering from ion acoustic wave fluctuations and the second to resolve scattering from electron plasma wave fluctuations. Expected signal levels relative to background will be presented for typical target configurations (hohlraums and a planar foil).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of high-dynamic range x-ray Thomson scattering spectra for the characterization of nano-plasmas at LCLS

Atomic clusters can serve as ideal model systems for exploring ultrafast (∼100 fs) laser-driven ionization dynamics of dense matter on the nanometer scale. Resonant absorption of optical laser pulses enables heating to temperatures on the order of 1 keV at near solid density conditions. To date, direct probing of transient states of such nano-plasmas was limited to coherent x-ray imaging. Here we present the first measurement of spectrally resolved incoherent x-ray scattering from clusters, enabling measurements of transient temperature, densities, and ionization. Single shot x-ray Thomson scattering signals were recorded at 120 Hz using a crystal spectrometer in combination with a single-photon counting and energy-dispersive pnCCD. A precise pump laser collimation scheme enabled recording near background-free scattering spectra from Ar clusters with an unprecedented dynamic range of more than 3 orders of magnitude. Such measurements are important for understanding collective effects in laser-matter interactions on femtosecond time scales, opening new routes for the development of schemes for their ultrafast control.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thomson scattering measurements from asymmetric interpenetrating plasma flows

Imaging Thomson scattering measurements of collective ion-acoustic fluctuations have been utilized to determine ion temperature and density from laser produced counter-streaming asymmetric flows. Two foils are heated with 8 laser beams each, 500 J per beam, at the Omega Laser facility. Measurements are made 4 mm from the foil surface using a 60 J 2ω probe laser with a 200 ps pulse length. Measuring the electron density and temperature from the electron-plasma fluctuations constrains the fit of the multi-ion species, asymmetric flows theoretical form factor for the ion feature such that the ion temperatures, ion densities, and flow velocities for each plasma flow are determined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Statistical inference of collision frequencies from x-ray Thomson scattering spectra

Thomson scattering spectra measure the response of plasma particles to incident radiation. In warm dense matter, which is opaque to visible light, x-ray Thomson scattering (XRTS) enables a detailed probe of the electron distribution and has been used as a diagnostic for electron temperature, density, and plasma ionization. In this work, we examine the sensitivities of inelastic XRTS signatures to modeling details, including the dynamic collision frequency and the electronic density of states. Applying verified Monte Carlo inversion methods to dynamic structure factors obtained from time-dependent density functional theory, we assess the utility of XRTS signals as a way to inform the dynamic collision frequency, especially its direct-current limit, which is directly related to the electrical conductivity.

Collision frequency↗

Direct observation of the two-plasmon-decay common plasma wave using ultraviolet Thomson scattering

A 263-nm Thomson-scattering beam was used to directly probe two-plasmon-decay (TPD) excited electron plasma waves (EPWs) driven by between two and five 351-nm beams on the OMEGA Laser System. The amplitude of these waves was nearly independent of the number of drive beams at constant overlapped intensity, showing that the observed EPWs are common to the multiple beams. In an experimental configuration where the Thomson-scattering diagnostic was not wave matched to the common TPD EPWs, a broad spectrum of TPD-driven EPWs was observed, indicative of nonlinear effects associated with TPD saturation. Electron plasma waves corresponding to Langmuir decay of TPD EPWs were observed in both Thomson-scattering spectra, suggesting the Langmuir decay instability as a TPD saturation mechanism. Simulated Thomson-scattering spectra from three-dimensional numerical solutions of the extended Zakharov equations of TPD are in excellent agreement with the experimental spectra and verify the presence of the Langmuir decay instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interpenetration and deflection phenomena in collisions between supersonic, magnetized, tungsten plasma flows diagnosed using high resolution optical Thomson scattering

An optical Thomson scattering diagnostic has been used to investigate collisions between supersonic, magnetized plasma flows, in particular the transition from collisionless to collisional interaction dynamics. These flows were produced using tungsten wire array z-pinches, driven by the 1.4 MA 240 ns Magpie generator at Imperial College London. Measurements of the collective-mode Thomson scattering ion-feature clearly indicate that the ablation flows are interpenetrating at 100 ns (after current start), and this interpenetration continues until at least 140 ns. The Thomson spectrum at 150 ns shows a clear change in the dynamics of the stream interactions, transitioning towards a collisional, shock-like interaction of the streams near the axis. The Thomson scattering data also provide indirect evidence of the presence of a significant toroidal magnetic field embedded in the “precursor” plasma near the axis of the array over the period 100–140 ns; these observations are in agreement with previous measurements [Swadling et al., Phys. Rev. Lett. 113, 035003 (2014)]. The Thomson scattering measurements at 150 ns suggest that this magnetic field must collapse at around the time the dense precursor column begins to form.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Control and automation of the Pegasus multi-point Thomson scattering system

A new control system for the Pegasus Thomson scattering diagnostic has recently been deployed to automate the laser operation, data collection process, and interface with the system-wide Pegasus control code. Automation has been extended to areas outside of data collection, such as manipulation of beamline cameras and remotely controlled turning mirror actuators to enable intra-shot beam alignment. Additionally, the system has been upgraded with a set of fast (∼1 ms) mechanical shutters to mitigate contamination from background light. Modification and automation of the Thomson system have improved both data quality and diagnostic reliability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conceptual design of a divertor Thomson scattering diagnostic for NSTX-U

A conceptual design for a divertor Thomson scattering (DTS) diagnostic has been developed for the NSTX-U device to operate in parallel with the existing multipoint Thomson scattering system. Higher projected peak heat flux in NSTX-U will necessitate application of advanced magnetics geometries and divertor detachment. Interpretation and modeling of these divertor scenarios will depend heavily on local measurement of electron temperature, T{sub e}, and density, n{sub e}, which DTS provides in a passive manner. The DTS design for NSTX-U adopts major elements from the successful DIII-D DTS system including 7-channel polychromators measuring T{sub e} to 0.5 eV. If implemented on NSTX-U, the divertor TS system would provide an invaluable diagnostic for the boundary program to characterize the edge plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray Thomson scattering measurements of temperature and density from multi-shocked CH capsules

Proof-of-principle measurements of the electron densities, temperatures, and ionization states of spherically compressed multi-shocked CH (polystyrene) capsules have been achieved using spectrally resolved x-ray Thomson scattering. A total energy of 13.5 kJ incident on target is used to compress a 70 μm thick CH shell above solid-mass density using three coalescing shocks. Separately, a laser-produced zinc He-α x-ray source at 9 keV delayed 200 ps-800 ps after maximum compression is used to probe the plasma in the non-collective scattering regime. The data show that x-ray Thomson scattering enables a complete description of the time-dependent hydrodynamic evolution of shock-compressed CH capsules, with a maximum measured density of ρ > 6 g cm –3 . Additionally, the results demonstrate that accurate measurements of x-ray scattering from bound-free transitions in the CH plasma demonstrate strong evidence that continuum lowering is the primary ionization mechanism of carbon L-shell electrons.

42 ENGINEERING↗

Design calculations for a xenon plasma x-ray shield to protect the NIF optical Thomson scattering diagnostic

An Optical Thomson Scattering (OTS) diagnostic is currently being developed for the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. This diagnostic is designed to make measurements of the hohlraum plasma parameters, such as the electron temperature and the density, during inertial confinement fusion (ICF) experiments. NIF ICF experiments present a very challenging environment for optical measurements; by their very nature, hohlraums produce intense soft x-ray emission, which can cause “blanking” (radiation induced opacity) of the radiation facing optical components. The soft x-ray fluence at the surface of the OTS blast shield, 60 cm from the hohlraum, is estimated to be ∼8 J cm{sup −2}. This is significantly above the expected threshold for the onset of “blanking” effects. A novel xenon plasma x-ray shield is proposed to protect the blast shield from x-rays and mitigate “blanking.” Estimates suggest that an areal density of 10{sup 19} cm{sup −2} Xe atoms will be sufficient to absorb 99.5% of the soft x-ray flux. Two potential designs for this shield are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulse-burst laser-based 10 kHz Thomson scattering measurements

Thomson scattering (TS), as a popular and reliable diagnostic technique, has successfully measured electron temperatures and electron number densities of plasmas for many years. Yet, conventional TS techniques using Nd:YAG lasers operate only at tens of hertz. In this work, we introduce the development of a high-repetition-rate TS instrument based on a high-speed, pulse-burst laser system to greatly increase the temporal resolution of measurements. Successful instrument prototype testing was carried out by collecting TS light from laboratory helium and argon plasmas at 10 kHz. Calibration of the instrument detection sensitivity using nitrogen/oxygen rotational Raman scattering signal is also presented. Quantitative electron number densities and electron temperatures of the plasma were acquired at 10 kHz, for stable plasma discharges as, respectively, ~0.9 eV and ~5.37 × 10 21 m ₋3 for the argon plasma, and ~1 eV and ~6.5 × 10 21 m ₋3 for the helium plasma.

47 OTHER INSTRUMENTATION↗

Transfer learning for analysis of collective and non-collective Thomson scattering spectra

Thomson scattering (TS) diagnostics provide reliable, minimally perturbative measurements of fundamental plasma parameters, such as electron density (⁠n e ) and electron temperature (⁠T e ⁠). Deep neural networks can provide accurate estimates of ⁠n e and T e when conventional fitting algorithms may fail, such as when TS spectra are dominated by noise, or when fast analysis is required for real-time operation. Although deep neural networks typically require large training sets, transfer learning can improve model performance on a target task with limited data by leveraging pre-trained models from related source tasks, where select hidden layers are further trained using target data. We present five architecturally diverse deep neural networks, pre-trained on synthetic TS data and adapted for experimentally measured TS data, to evaluate the efficacy of transfer learning in estimating n e and T e in both the collective and non-collective scattering regimes. We evaluate errors in n e and T e estimates as a function of training set size for models trained with and without transfer learning, and we observe decreases in model error from transfer learning when the training set contains ≲ 200 experimentally measured spectra.

Artificial neural networks↗

Portable diagnostic package for Thomson scattering and optical emission spectroscopy on Princeton field-reversed configuration 2 (PFRC 2)

An Advanced Research Projects Agency-Energy funded diagnostic system has been deployed to the Princeton field-reversed configuration 2 (PFRC-2) device, located at Princeton Plasma Physics Laboratory. The Portable Diagnostic Package (PDP), designed at Oak Ridge National Laboratory, allows for the measurement of Thomson Scattering (TS) for electron density and temperature and Optical Emission Spectroscopy (OES) for ion temperature, impurity density, and ion velocity. A tunable spectrometer on the PDP with three gratings provides the flexibility to measure low (1 eV) and high (1000 eV) electron temperature ranges from TS. Additionally, using a second spectrometer, the OES diagnostic can survey light emission from various ion excitation levels for wide wavelength ranges. The electron density (<2 × 10 19 m –3 ) of plasmas generated in PFRC-2 has been below the PDP TS discrimination threshold, which has made TS signal detection challenging against a high-background of laser stray light. The laser stray light was iteratively reduced by making modifications to the entrance and exit geometry on PFRC-2. Rayleigh scattering experiments on PFRC have yielded the TS discrimination sensitivity to be >1 × 10 20 m –3 for the PDP. A recently implemented narrow-band notch spectral filter that masks the second harmonic 532 nm Nd:YAG laser wavelength has increased the system’s TS light discrimination sensitivity 65 times compared to the instance when the notch filter was not implemented. The hardware implementation including design changes to the flight tubes and Brewster windows will be discussed, along with results from Rayleigh and rotational Raman scattering sensitivity analyses, which were used to establish a quantitative figure of merit on the system performance. Further, the Raman scattering calibration with the notch filter has improved the PDP electron density threshold to 1 ± 0.5 × 10 18 m –3 .

47 OTHER INSTRUMENTATION↗

Implementation of a portable diagnostic system for Thomson scattering measurements on an electrothermal arc source

To fulfill the increasing needs of diagnostic support for researchers in plasma technology, a portable diagnostic package (PDP) equipped for both laser Thomson scattering (TS) and optical emission spectroscopy has been designed and constructed at Oak Ridge National Laboratory (ORNL), aiming to measure the temperature and number density of electrons and temperatures of ions in plasma devices. The PDP has been initially implemented on a high density and low temperature electrothermal arc source (ET-arc) at ORNL to test its TS capability. TS from the plasmas in the ET-arc has been obtained using the PDP. The electron temperature and number density were determined from TS spectra. These results were then compared to measurements from previous studies on the ET-arc. The TS diagnostic measured 0.8 ± 0.1, 1.3 ± 0.2, and 0.7 ± 0.1 eV and (4.4 ± 0.5) × 1021, (5.9 ± 0.7) × 1021, and (4.3 ± 0.5) x 1021 m-3, respectively, from three lines of sight that transect the plasma column.

He, Z. (ORCID:0000000183159882)↗

Improving a high-efficiency, gated spectrometer for x-ray Thomson scattering experiments at the National Ignition Facility

We are developing x-ray Thomson scattering for applications in implosion experiments at the National Ignition Facility. In particular we have designed and fielded MACS, a high-efficiency, gated x-ray spectrometer at 7.5–10 keV [T. Döppner et al., Rev. Sci. Instrum. 85, 11D617 (2014)]. Here we report on two new Bragg crystals based on Highly Oriented Pyrolytic Graphite (HOPG), a flat crystal and a dual-section cylindrically curved crystal. We have performed in situ calibration measurements using a brass foil target, and we used the flat HOPG crystal to measure Mo K-shell emission at 18 keV in 2nd order diffraction. Such high photon energy line emission will be required to penetrate and probe ultra-high-density plasmas or plasmas of mid-Z elements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dual-pass upgrade to the Thomson scattering diagnostic on the Prototype-Material Plasma Exposure eXperiment (Proto-MPEX)

The Thomson scattering (TS) diagnostic on the Prototype-Material Plasma Exposure eXperiment has been upgraded to measure electron temperature (T e ) and density (n e ) simultaneously at two axial locations. After the first pass through the vacuum vessel, the exiting laser beamline is re-collimated in the atmosphere and rerouted into the vacuum vessel for the second pass. The upgrade will help diagnose axial T e and n e gradients between the “central chamber” and the target region which are located 1 m and 2.5 m, respectively, downstream from the Helicon radio-frequency source. The TS measurements have given T e ≈ 4–15 eV and n e ≈ 2–4 × 10 19 m -3 at the central chamber and T e ≈ 1–2 eV and n e ≈ 1–2 × 10 19 m -3 at the target region. The upgrade also increases the number of sampling points at the target region from 3 fibers to 5 fibers, measuring 3 cm radially across the plasma column, and 25 fibers in the central chamber, radially spanning 8 cm. The intensified CCD camera is double triggered for each laser pulse in order to measure (1) the TS and laser stray light and (2) the plasma background light that contains nuisance emission lines and bremsstrahlung. Subtracting the background light from the TS photons improves the temperature and density measurements. Details of the diagnostic setup, axial and radial measurements, and areas for further optimization are discussed.

dual-pass Thomson Scattering↗