Improving the time response of a gamma/neutron liquid detector
Presentation describes proposed 5x5 NSDE detector system designed to improve response times in gamma/neutron liquid detector array.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Presentation describes proposed 5x5 NSDE detector system designed to improve response times in gamma/neutron liquid detector array.
The Vision Zero-Safe Systems Approach prioritizes fast access to Emergency Medical Services (EMS) to improve the survivability of road users in transportation crashes, especially concerning the recent increase in pedestrian-involved crashes. Pedestrian crashes resulting in immediate or early death are considerably more severe than those taking longer. The time gap between injury and fatality is known as survival time, and it heavily relies on EMS response time. The characteristics of the crash location may be associated with EMS response and survival time. A US Department of Transportation initiative identifies communities often facing challenges. Six disadvantaged community (DAC) indicators, including economy, environment, equity, health, resilience, and transportation access, enable an analysis of how survival and EMS response times vary across DACs and non-DACs. To this end, this study created a unique and comprehensive database by linking DACs data with 2017–2021 pedestrian-involved fatal crashes. This study utilizes two-stage residual inclusion models with segmentation for DACs and non-DACs accounting for the endogenous relationship between EMS response and pedestrian survival time. The results indicate that EMS response time is higher and pedestrian survival time is lower in DACs than in non-DACs. A delayed EMS response time is associated with a greater reduction in survival time in DACs compared to non-DACs. Factors, e.g., nighttime and interstate crashes, contribute to higher EMS response time, while pedestrian drugs, driver speeding, and hit-and-run behaviors are associated with a greater reduction in survival time in DACs than non-DACs. Finally, the implications of the findings are discussed in the paper.
The theoretical minimum transactional response time of an application serves as a basis for the expected response time. The lower threshold for the minimum response time represents the minimum amount of time that the application should take to complete a transaction. Knowing the lower threshold is beneficial in detecting anomalies that are results of unsuccessful transactions. On the converse, when an application's response time falls above an upper threshold, there is likely an anomaly in the application that is causing unusual performance issues in the transaction. This report explains how the non-stationary Generalized Extreme Value distribution is used to estimate the lower threshold of an application's daily minimum transactional response time. It also explains how the seasonal Autoregressive Integrated Moving Average time series model is used to estimate the upper threshold for an application's average transactional response time.
Abstract not provided.
A digitalized NMS (Neutron Measurement System) has a better performance than an analogue type in aspects of operating, maintenance and calibration. But some limitations in this system were found in the response time due to the inherent digital filtering time. The response time requirement as a kind of safety requirement is a significant factor that should be met. To satisfy the requirements, two approaches are herein suggested in a practical manner. Modifying conditions of the trip parameters and adjusting the testing methodology were applied to relieve the response time requirement. For a further enhanced and realistic response time, revised requirements for the response time of digitalized NMS are proposed in this paper. (authors)
Safety limits are required to maintain the integrity of physical barriers designed to prevent the uncontrolled release of radioactive materials in nuclear power plants. The safety analysis establishes two critical constraints that include an analytical limit in terms of a measured or calculated variable, and a specific time after the analytical limit is reached to begin protective action. Keeping with the nuclear regulations and industry standards, satisfying these two requirements will ensure that the safety limit will not be exceeded during the design basis event, either an anticipated operational occurrence or a postulated accident. Various studies on the setpoint determination methodology for the safety-related instrumentation have been actively performed to ensure that the requirement of the analytical limit is satisfied. In particular, the protection setpoint methodology for the advanced power reactor 1400 (APP1400) and the optimized power reactor 1000 (OPR1000) has been recently developed to cover both the design basis event and the beyond design basis event. The developed setpoint methodology has also been quantitatively validated using specific computer programs and setpoint calculations. However, the safety of nuclear power plants cannot be fully guaranteed by satisfying the requirement of the analytical limit. In spite of the response time verification requirements of nuclear regulations and industry standards, it is hard to find the studies on the systematically integrated methodology regarding the response time evaluation. In cases of APR1400 and OPR1000, the response time analysis for the plant protection system is partially included in the setpoint calculation and the response time test is separately performed via the specific plant procedure. The test technique has a drawback which is the difficulty to demonstrate completeness of timing test. The analysis technique has also a demerit of resulting in extreme times that not actually possible. Thus, the establishment of the systematic response time evaluation methodology is needed to justify the conformance to the response time requirement used in the safety analysis. This paper proposes the response time evaluation methodology for APR1400 and OPR1000 using the combined analysis and test technique to confirm that the plant protection system can meet the analytical response time assumed in the safety analysis. In addition, the results of the quantitative evaluation performed for APR1400 and OPR1000 are presented in this paper. The proposed response time analysis technique consists of defining the response time requirement, determining the critical signal path for the trip parameter, allocating individual response time to each component on the signal path, and analyzing the total response time for the trip parameter, and demonstrates that the total analyzed response time does not exceed the response time requirement. The proposed response time test technique is composed of defining the response time requirement, determining the critical signal path for the trip parameter, determining the test method for each component on the signal path, performing the response time test, and demonstrates that the total test result does not exceed the response time requirement. The total response time should be tested in a single test that covers from the sensor to the final actuation device on the instrument channel. When the total channel is not tested in a single test, separate tests on groups of components or single components including the total instrument channel shall be combined to verify the total channel response. For APR1400 and OPR1000, the ramp test technique is used for the pressure and differential pressure transmitters and the step function testing technique is applied to the signal processing equipment and final actuation device. As a result, it can be demonstrated that the response time requirement is satisfied by the combined analysis and test technique. Therefore, the proposed methodology in this paper plays a crucial role in guaranteeing the safety of the nuclear power plants systematically satisfying one of two critical requirements from the safety analysis. (authors)
Imaginary-time response functions of finite-temperature quantum systems are often obtained with methods that exhibit stochastic or systematic errors. Reducing these errors comes at a large computational cost—in quantum Monte Carlo simulations, the reduction of noise by a factor of two incurs a simulation cost of a factor of four. In this paper, we relate certain imaginary-time response functions to an inner product on the space of linear operators on Fock space. We then show that data with noise typically does not respect the positive definiteness of its associated Gramian. The Gramian has the structure of a Hankel matrix. As a method for denoising noisy data, we introduce an alternating projection algorithm that finds the closest positive definite Hankel matrix consistent with noisy data. We test our methodology at the example of fermion Green's functions for continuous-time quantum Monte Carlo data and show remarkable improvements of the error, reducing noise by a factor of up to 20 in practical examples. We argue that Hankel projections should be used whenever finite-temperature imaginary-time data of response functions with errors is analyzed, be it in the context of quantum Monte Carlo, quantum computing, or in approximate semianalytic methodologies. Published by the American Physical Society 2024
In collective I/O, MPI processes exchange requests so that the rearranged requests can result in the shortest file system access time. Scheduling the exchange sequence determines the response time of participating processes. Existing implementations that simply follow the increasing order of file ofsets do not necessary produce the best performance. To minimize the average response time, we propose three scheduling algorithms that consider the number of processes per file stripe and the number of accesses per process. Our experimental results demonstrate improvements of up to 50% in the average response time using two synthetic benchmarks and a high-resolution climate application.
Hybrid power systems, such as combinations of renewable power sources with intermittent power production and non-renewable power sources, theoretically increase the reliability and thus integration of renewable sources in the electrical system. However, a recent increase in the number of hybrid installations has sparked interest in the effects of their connection to the grid, especially in remote areas. This paper analyses a photovoltaic-gas microturbine hybrid system dimensioned to be installed in La Paz (Mexico).The research presented in this paper studies and quantifies the effects on the total electric power produced, varying both the solar radiation and the gas microturbine response time. The gas microturbine and the photovoltaic panels are modelled using Matlab/Simulink software, obtaining a platform where different tests to simulate real conditions have been executed. They consist of diverse ramps of irradiance that replicate solar radiation variations, and different microturbine response times reproduced by the time constants of a first order transfer function that models the microturbine dynamic response. The results obtained show that when radiation varies quickly it does not produce significant differences in the power guarantee or the microturbine gas consumption, to any microturbine response time. However, these two parameters are highly variable with smooth radiance variations. The maximum total power variation decreases greatly as the radiation variation gets lower. In addition, by decreasing the microturbine response time, it is possible to appreciably increase the power guarantee although the maximum power variation and gas consumption increase. Only in cases of low radiation variation is there no appreciable difference in the maximum power variation obtained by the different turbine response times.
The Advanced Test Reactor (ATR) has always had a comprehensive procedure to verify the performance of its critical transmitters and sensors, including RTDs, and pressure, level, and flow transmitters. These transmitters and sensors have been periodically tested for response time and calibration verification to ensure accuracy. With implementation of online monitoring techniques at ATR, the calibration verification and response time testing of these transmitters and sensors are verified remotely, automatically, hands off, include more portions of the system, and can be performed at almost any time during process operations. The work was done under a DOE funded SBIR project carried out by AMS. As a result, ATR is now able to save the manpower that has been spent over the years on manual calibration verification and response time testing of its temperature and pressure sensors and refocus those resources towards more equipment reliability needs. More importantly, implementation of OLM will help enhance the overall availability, safety, and efficiency. Together with equipment reliability programs of ATR, the integration of OLM will also help with I&C aging management goals of the Department of Energy and long-time operation of ATR.
Health Physics Services (HPS) received feedback from a customer service survey regarding the difference in response times between the Thermo ASP-2S1/NRD (Thermo) and Ludlum Model 30-7B (Ludlum). In response to the feedback, tests were performed in the field and duplicated in a laboratory to evaluate and compare each instrument’s response time to reach an applied exposure. The results of the tests showed that optimizing its screen refresh rate by updating the Ludlum’s firmware improves response time, making it more comparable to the Thermo.
A flat-field extreme ultraviolet (EUV) spectrometer working in the 20-500 Å wavelength range with fast time response has been newly developed to measure line emissions from highly ionized tungsten in the Experimental Advanced Superconducting Tokamak (EAST) with a tungsten divertor, while the monitoring of light and medium impurities is also an aim in the present development. A flat-field focal plane for spectral image detection is made by a laminar-type varied-line-spacing concave holographic grating with an angle of incidence of 87°. A back-illuminated charge-coupled device (CCD) with a total size of 26.6 × 6.6 mm{sup 2} and pixel numbers of 1024 × 255 (26 × 26 μm{sup 2}/pixel) is used for recording the focal image of spectral lines. An excellent spectral resolution of Δλ{sub 0} = 3-4 pixels, where Δλ{sub 0} is defined as full width at the foot position of a spectral line, is obtained at the 80-400 Å wavelength range after careful adjustment of the grating and CCD positions. The high signal readout rate of the CCD can improve the temporal resolution of time-resolved spectra when the CCD is operated in the full vertical binning mode. It is usually operated at 5 ms per frame. If the vertical size of the CCD is reduced with a narrow slit, the time response becomes faster. The high-time response in the spectral measurement therefore makes possible a variety of spectroscopic studies, e.g., impurity behavior in long pulse discharges with edge-localized mode bursts. An absolute intensity calibration of the EUV spectrometer is also carried out with a technique using the EUV bremsstrahlung continuum at 20-150 Å for quantitative data analysis. Thus, the high-time resolution tungsten spectra have been successfully observed with good spectral resolution using the present EUV spectrometer system. Typical tungsten spectra in the EUV wavelength range observed from EAST discharges are presented with absolute intensity and spectral identification.
The purpose of the work was to measure pulse shape and timing response of the silicon under picosecond lasers light illumination. Timing response for different laser wavelengths, 405 nm, 635 nm and 1060 nm was a point of interest. The performed measurements could be useful for CMS HGCal upgrade
The Advanced Test Reactor (ATR) has always had a comprehensive procedure to verify the performance of its critical transmitters and sensors, including RTDs, and pressure, level, and flow transmitters. These transmitters and sensors have been periodically tested for response time and calibration verification to ensure accuracy. With implementation of on-line monitoring techniques at ATR, the calibration verification and response time testing of these transmitters and sensors are verified remotely, automatically, hands off, include more portions of the system, and can be performed at almost any time during process operations. The work was done under a DOE funded SBIR project carried out by AMS. As a result, ATR is now able to save the manpower that has been spent over the years on manual calibration verification and response time testing of its temperature and pressure sensors and refocus those resources towards more equipment reliability needs. More importantly, implementation of OLM will help enhance the overall availability, safety, and efficiency. Together with equipment reliability programs of ATR, the integration of OLM will also help with I and C aging management goals of the Department of Energy and long-time operation of ATR. (authors)
We present the measurements of thermal emittance and response time for a GaN photocathode illuminated with 5 ps pulses at 260 nm wavelength. The thermal emittance was measured downstream of a 100 kV dc gun using a solenoid scan with a wire scanner and a beam viewscreen and was found to be 1.35 {+-} 0.11 mm mrad normalized rms emittance per 1 mm rms of illuminated spot size. The response time of the photoemitted electrons was evaluated using a deflecting mode rf cavity synchronized to the laser pulses and was found to be prompt within the time resolution capability of our setup.
The real-time, in-line monitoring of continuous flow concentrations is widely conducted via infrared (IR) spectrometry by using a flow cell connected to a reactive flow stream. For protective purposes, the IR sensor tip is typically offset from the flow. This offset can cause the formation of a stagnant boundary layer above the sensor, especially when dealing with high-viscosity fluids. As a result, the IR signal response time is often controlled by the slow diffusional exchange of fluid in the boundary layer, as confirmed via 2D computational fluid dynamics (CFD) simulations. We evaluated several flow configuration modifications in a typical IR flow cell in order to identify the changes to the flow dynamics that enable improved response times with minimal changes to the cell configuration: the use of (i) vertical flow, where the standard horizontal flow over the sensor is redirected to contact vertically with the sensor, (ii) a static mixer to create radial flow momentum above the IR sensor, and (iii) horizontal or vertical nozzles to direct the flow toward the IR sensor. The vertical flow configuration did not show any significant improvement over the standard horizontal flow configuration. However, the static mixer, horizontal nozzle, and vertical nozzle configurations all resulted in markedly improved response times and signal quality, albeit at the expense of a higher pressure drop across the flow cell. These results point toward straightforward, user-accessible modifications of in-line IR flow cells that result in significant improvements in signal stability and acquisition times.
An analytical expression for the relaxation time of a nematic liquid crystal is obtained for the first time by considering the influence of surface viscosity, anchoring energy strength and cell gap, validated numerically by using the so-called relaxation method. This general equation for the molecular response time (τ{sub 0}) was derived for a vertical aligned cell and by solving an eigenvalue equation coming from the usual balance of torque equation in the Derzhanskii and Petrov formulation, recovering the usual equations in the appropriate limit. The results show that τ∼d{sup b}, where b=2 is observed only for strongly anchored cells, while for moderate to weak anchored cells, the exponent lies between 1 and 2, depending on both, surface viscosity and anchoring strength. We found that the surface viscosity is important when calculating the response time, specially for thin cells, critical for liquid crystal devices. The surface viscosity’s effect on the optical response time with pretilt is also explored. Our results bring new insights about the role of surface viscosity and its effects in applied physics. - Highlights: • The relaxation of nematic liquid crystals is calculated by taking the surface viscosity into account. • An analytical expression for the relaxation time depending on surface viscosity, anchoring strength and cell gap is obtained. • The results are numerically verified. • Surface viscosity is crucial for thin and weak anchored cells. • The effect on optical time and pretilt angle is also studied.