Search NASA⌕ Search

SEARCH · Search NASA

Results for “TM-30”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Experimental validation of color rendition specification criteria based on ANSI/IES TM-30-18

An experiment was conducted to examine color preference specification criteria. Twenty-five participants each evaluated 90 lighting scenes in a room filled with objects. The lighting scenes included nine chromaticity groups, each with 10 systematically-varied color rendition conditions designed to meet or not meet previously proposed color preference specification criteria using ANSI/IES TM-30-18 Rf, Rcs,h1, and Rg. The color rendition conditions did not meet the criterion for none, one, two, or all three of these measures. Participants, who chromatically adapted to each chromaticity group, rated the objects’ color appearance on eight-point scales for saturated-dull, normal-shifted, and like-dislike (preference), as well as a binary for acceptable or unacceptable. The findings corroborate past work, but also indicate that color preference criteria could be adjusted slightly to improve performance, with Tier A having Rf = 78, Rg = 95, and -1% = Rcs,h1 = 15%, Tier B having Rf = 74, Rg = 92, and -7% = Rcs,h1 = 19%, and Tier C having Rf = 70, Rg = 89, -12% = Rcs,h1 = 23%. A companion regression analysis shows models based on Rf, Rg, and Rcs,h1 were superior in predicting color preference compared to those using other measures of color rendition.

Royer, Michael P.↗

PNNL Report: New Study Validates Color-Rendition Specification Criteria Based on TM-30

Pacific Northwest National Laboratory (PNNL) has released the results of a study – published in Lighting Research & Technology – that validates color-preference specification criteria based on ANSI/IES TM-30-18. The result provides additional data to support TM-30 Annex E (in press), which will include tiers of recommended specification criteria for different goals (color preference, color vividness, and color fidelity), among other information related to color rendition specification. Standardized methods for evaluating the color rendition of light sources have progressed rapidly in the past five years, beginning with the publication of IES TM-30-15, followed by the adoption of CIE 224:2017, and culminating with the issuance of ANSI/IES TM-30-18 (which revised TM-30-15, made it a national standard, and unified the calculation framework of CIE 224 and IES TM-30). Importantly, none of these documents provided guidance on how to specify color rendition using the included measures; that is, no value or combination of values was identified that leads to any desired quality of the light. Dozens of experiments over the past 60 years have examined subjective evaluations of color quality—such as preference, naturalness, or vividness—although the focus has traditionally been on developing a single-number color quality metric rather than specification criteria. Further, many of these pre-LED and pre-TM-30 studies were limited in their ability to vary the lighting characteristics, preventing them from generating a complete and accurate picture of what influences color rendering quality in architectural spaces. A renewed emphasis in this area of research over the past four years has yielded a growing consensus about how measures of color fidelity (Rf), gamut area (Rg), and red chroma (Rcs,h1) can be used in combination to effectively describe several important perceptual attributes. In the new study, which was the third in a series conducted at PNNL, 90 lighting conditions with systematically varied color rendition and chromaticity were evaluated by 25 participants, who provided ratings for normalness, saturation, preference, and acceptability. The lighting conditions were specifically designed to test the bounds of previously proposed color preference criteria, while simultaneously verifying the applicability of the criteria across different values of CCT and Duv. In line with the preceding work, there were substantial differences in ratings based on color rendition, but minimal differences based on chromaticity. The tested criteria performed well, although after the experiment, some small adjustments in lower limits provided more effective divisions between tiers of performance. The adjusted criteria are: • Level 1: Rf = 78, Rg = 95, -1% = Rcs,h1 = 15% • Level 2: Rf = 74, Rg = 92, -7% = Rcs,h1 = 19% • Level 3: Rf = 70, Rg = 89, -12% = Rcs,h1 = 23%. These criteria were concurrently checked against the results from other, independent experiments, and will be included in ANSI/IES TM-30 Annex E as the specifications for color preference. The new criteria will be a valuable tool for improving lighting quality and balancing the tradeoff between color rendition and energy efficiency.

Royer, Michael P.↗

What Is the Reference? An Examination of Alternatives to the Reference Sources Used in IES TM-30-15

A study was undertaken to document the role of the reference illuminant in the IES TM-30-15 method for evaluating color rendition. TM-30-15 relies on a relative reference scheme; that is, the reference illuminant and test source always have the same correlated color temperature (CCT). The reference illuminant is a Planckian radiator, model of daylight, or combination of those two, depending on the exact CCT of the test source. Three alternative reference schemes were considered: 1) either using all Planckian radiators or all daylight models; 2) using only one of ten possible illuminants (Planckian, daylight, or equal energy), regardless of the CCT of the test source; 3) using an off-Planckian reference illuminant (i.e., a source with a negative Duv). No reference scheme is inherently superior to another, with differences in metric values largely a result of small differences in gamut shape of the reference alternatives. While using any of the alternative schemes is more reasonable in the TM-30-15 evaluation framework than it was with the CIE CRI framework, the differences still ultimately manifest only as changes in interpretation of the results. References are employed in color rendering measures to provide a familiar point of comparison, not to establish an ideal source.

CAM02-UCS↗

IES TM-30-15 Is Approved—Now What?: Moving Forward with New Color Rendition Measures

IES TM-30-15 [IES, 2015; David and others, 2015] has the potential to change the way light sources are engineered and specified, helping to increase the benefit of electric lighting. Getting there, however, will require a paradigm shift in how we think about color rendering, and a concerted effort to choose better tools over familiar ones. Undoubtedly, engineering and specifying lighting is becoming increasingly complex, but this has been the case throughout history; the tradeoffs between cost, quality, and efficiency breed innovation, but also the need for better and more thorough ways to design products and differentiate between them. This editorial discusses the potential role of various subsets of the lighting industry in ensuring that TM-30-15 reaches its potential.

Color rendering↗

Evaluating Light Source Color Rendition using the IES TM-30-15 Method

A system for evaluating the color rendition of light sources was recently published as IES TM-30-15 IES Method for Evaluating Light Source Color Rendition. The system includes a fidelity index (Rf) to quantify similarity to a reference illuminant, a relative-gamut index (Rg) to quantify saturation relative to a reference illuminant, and a color vector icon that visually presents information about color rendition. The calculation employs CAM02-UCS and uses a newly-developed set of reflectance functions, comprising 99 color evaluation samples (CES). The CES were down-selected from 105,000 real object samples and are uniformly distributed in color space (fairly representing different colors) and wavelength space (avoiding artificial increase of color rendition values by selective optimization).

color fidelity↗

TM-30 Guidance

Minimum color quality standards are necessary, because the light sources most efficient at producing lumens are impractical for use in architectural lighting due to poor color rendition. Thus, accurate measures of color rendition and accompanying performance criteria are essential for helping technology developers and users balance tradeoffs between energy efficiency and lighting quality. Setting higher color-rendition criteria while maintaining use of CRI (e.g., CRI ≥ 90) may filter out some unacceptable light sources, but also filters out many highly desirable light sources and requires a greater tradeoff with energy efficiency. In contrast, specifying color rendition using TM-30 Rf, Rg, and Rcs,h1 has been shown to be effective for differentiating desirable sources while maintaining flexibility for technology development and energy efficiency.

Royer, Michael P.↗

Correspondence: In support of the IES method of evaluating light source colour rendition

In this editorial, written as an open letter to the lighting community, we stand in support of widespread adoption of TM-30-15: The IES Method of Evaluating Light Source Color Rendition. We introduce important considerations related to light source color rendition, define the need for a new method of evaluation, provide a high-level overview of the IES method, discuss some of the practical considerations related to the development of the IES method and the consensus process, and conclude by inviting you to join us in support of the new measures and graphics described in TM-30-15.

36 MATERIALS SCIENCE↗

Human Perceptions of Colour Rendition at Different Chromaticities

An experiment was conducted to evaluate how subjective impressions of a light source’s color quality depend upon color rendition and chromaticity. Thirty-three participants each evaluated 50 lighting scenes in a 3.7 m by 5.5 m room filled with objects selected to cover a range of hue, saturation, and lightness. The lighting scenes included five chromaticity groups, specified here using correlated color temperature (CCT) and Duv¬: 2700 K, 0.000; 2700 K, -0.007; 3500 K, 0.000; 4300 K, 0.000; 4300 K, -0.007. Within each group were the same 10 systematically-varied color rendition conditions. The Illuminating Engineering Society (IES) TM-30-15 Fidelity Index (Rf) values ranged from 60 to 93, IES TM-30 Gamut Index (Rg) values from 88 to 124, and IES TM-30 Hue Angle Bin 1 Chroma Shift (Rcs,h1) values from -15% to 28%. All lighting scenes had the same nominal illuminance. Participants were asked to rate each scene on eight point scales for saturated-dull, normal-shifted, and like-dislike, as well as choosing whether they found the scenes to be acceptable or unacceptable. The findings suggest that color rendition preferences can vary with chromaticity, but do not support absolute preferences for negative Duv values. At 4300 K, there was no difference in rated preference, saturation, normalness, or acceptability between the two groups with different Duv values. However, at 2700 K, there was a significant difference for all four perceptions, with the negative Duv sources being rated more liked (on average)—and for nine of the ten individual color rendition conditions. Further, across all levels of red chroma shift—according to TM-30 values Rcs,h1, Rcs,h15, and Rcs,h16—the room was rated as more saturated at 2700 K than at 3500 K or 4300 K (regardless of Duv); in turn, increases in red saturation were less preferred and less acceptable at 2700 K than the other CCTs. The differences in ratings between the chromaticity groups were substantially smaller than the range in ratings for the 10 color rendition conditions in each group, and on average the best fit model uses a combination of Rf, Rcs,h16, and potentially Rg. Despite the differences in ratings for chromaticity groups, a set of criteria identified in previous research for preferred color rendition in this generic application could be used for all groups. Those criteria are Rf = 74, -1% = Rcs,h1 = 15%, and Rg = 100.

Royer, Michael P.↗

Chroma Shift and Gamut Shape: Going Beyond Average Color Fidelity and Gamut Area

Though sometimes referred to as a two-measure system for evaluating color rendition, IES TM-30-15 includes other key components that go beyond the high-level average values IES Rf and IES Rg. This article focuses on the Color Vector Graphic and Local Chroma Shift (IES Rcs,hj), discussing the calculation methods for these evaluation tools and providing context for the interpretation of the values. It also presents alternatives for quantifying the same characteristics, which can inform the development of future measures. The Color Vector Graphic (CVG) is a visual representation of hue and chroma shifts across different hues. It quickly communicates complex information about how object colors will be rendered by a light source, although it is difficult or impossible to use for writing a specification. CVGs demonstrate that increases in chroma for certain hues sometimes means a decrease in chroma for other hues, and illustrates hue shifts for intermediate colors. The combination of shifts over different hues can be referred to as gamut shape. Complementing this information are the IES Rcs,hj values, which quantify the average relative chroma shift for samples in each of the 16 hue-angle bins (j) specified in IES TM-30-15. Unlike measures of average color fidelity and gamut area, gamut shape and hue-specific chroma shift are new concepts with no directly-comparable historical references. It will be critical to incorporate the Color Vector Graphic and Local Chroma Shift values into practice because they capture information about color rendition that is impossible to describe with average measures (such as CIE Ra, IES Rf, or IES Rg), but that is critical to understanding human evaluations of color quality in architectural environments.

Chroma Shift↗

The Role of Presented Objects in Deriving Color Preference Criteria from Psychophysical Studies

Of the many “components” of a color rendering measure, one is perhaps the most important: the set of color samples (spectral reflectance functions) that are employed as a standardized means of evaluating and rating a light source. At the same time, a standardized set of color samples can never apply perfectly to a real space or a real set of observed objects, meaning there will always be some level of mismatch between the predicted and observed color shifts. This mismatch is important for lighting specifiers to consider, but even more critical for experiments that seek to evaluate the relationship between color rendering measures and human perception. This article explores how the color distortions of three possible experimental object sets compare to the color distortions predicted using the color evaluation samples of IES TM-30-15 (TM-30). The experimental object sets include those from Royer and colleagues [2016], a set of produce (10 fruits and vegetables), and the X-rite Color Checker Classic. The differences are traced back to properties of the samples sets, such as the coverage of color space, average chroma level, and specific spectral features. The consequence of the differences, that the visual evaluation is based on color distortions that are substantially different from what is predicted, can lead to inaccurate criteria or models of a given perception, such as preference. To minimize the error in using criteria or models when specifying color rendering attributes for a given application, the criteria or models should be developed using a set of experimental objects that matches the typical objects of the application as closely as possible. Alternatively, if typical objects of an application cannot be reasonably determined, an object set that matches the distortions predicted by TM-30 as close as possible is likely to provide the most meaningful results.

60 APPLIED LIFE SCIENCES↗

Human perceptions of colour rendition vary with average fidelity, average gamut, and gamut shape

An experiment was conducted to evaluate how subjective impressions of color quality vary with changes in average fidelity, average gamut, and gamut shape (which considers the specific hues that are saturated or desaturated). Twenty-eight participants each evaluated 26 lighting conditions—created using four, seven-channel, tunable LED luminaires—in a 3.1 m by 3.7 m room filled with objects selected to cover a range of hue, saturation, and lightness. IES TM-30 fidelity index (Rf) values ranged from 64 to 93, IES TM-30 gamut index (Rg¬) values from 79 to 117, and IES TM-30 Rcs,h1 values (a proxy for gamut shape) from -19% to 26%. All lighting conditions delivered the same nominal illuminance and chromaticity. Participants were asked to rate each condition on eight point semantic differential scales for saturated-dull, normal-shifted, and like-dislike. They were also asked one multiple choice question, classifying the condition as saturated, dull, normal, or shifted. The findings suggest that gamut shape is more important than average gamut for human preference, where reds play a more important role than other hues. Additionally, average fidelity alone is a poor predictor of human perceptions, although Rf was somewhat better than CIE Ra. The most preferred source had a CIE Ra value of 68, and 9 of the top 12 rated products had a CIE Ra value of 73 or less, which indicates that the commonly used criteria of CIE Ra ≥ 80 may be excluding a majority of preferred light sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluating tradeoffs between energy efficiency and color rendition

Color rendition and energy efficiency have long been considered characteristics of light sources that cannot be maximized simultaneously. The tradeoff has been studied extensively, but usually considering only average color fidelity. This work examines the color rendition versus energy efficiency tradeoff in the context of ANSI/IES TM-30-18, Method for Evaluating Light Source Color Rendition, which provides numerous measures beyond average color fidelity. The analysis demonstrates that color rendition criteria based on combinations of ANSI/IES TM-30-18 values can be used to improve color quality with less of an effect on spectral efficiency (luminous efficacy of radiation) than increasing CIE Ra alone. No change in the direction of LED emitter or downconverter development is needed.

Royer, Michael P.↗

A method and tool to determine the colorimetric and photobiological properties of light transmitted through glass and other optical materials

Here we describe a framework and provides a computational tool to characterize the color quality and biological potential of light that is transmitted through glass and other optical materials. The IES TM-30 framework and Excel computation tool were adapted to evaluate color quality, with measures from CIE S 026, UL 24480, and the WELL Building Standard v2 added to evaluate biological potential. The user selects a pre-transmittance spectral power distribution (SPD), such as for a CIE D-Series Illuminant, Planckian radiation, electric lamp, or measurement of daylight at a building site. The tool allows a user to populate a database with spectral data for glazing or other optical materials, comprising spectral transmission and the spectral reflectance of both sides. The user creates a unit with one, two, or three panes of glazing or other optical materials, and the tool calculates the composite spectral transmittance accounting for reflections between materials. The tool computes the transmitted SPD, then determines colorimetric and photobiological outputs using the transmitted SPD as the test source. Glass, window, and skylight manufacturers can employ the tool to optimize glazing spectral transmission to achieve intentional colorimetric and photobiological performance with transmitted light. Electric lighting manufacturers, designers, and researchers can use the tool to evaluate the impact of glazing units and other optical materials on the color quality and biological potential of transmitted light.

36 MATERIALS SCIENCE↗

Correlated color temperature is not a suitable proxy for the biological potency of light

Using a simulation based on a real, five-channel tunable LED lighting system, we show that Correlated Color Temperature (CCT) is not a reasonable predictor of the biological potency of light, whether characterized with CIE melanopic Equivalent Daylight Illuminance (mel-EDI), Equivalent Melanopic Lux (EML) (a scalar multiple of mel-EDI), or Circadian Stimulus (CS). At a photopic corneal illuminance of 300 lx and Rf ≥ 70, spectra can vary in CS from 17 to 41% across CCTs from 2500 to 6000 K, and up to 23% at a single CCT, due to the choice of spectrum alone. The CS range is largest, and notably discontinuous, at a CCT of 3500 K, the location of the inflection point of the CS model. At a photopic corneal illuminance of 300 lx and Rf ≥ 70, mel-EDI can vary from 123 to 354 lx across CCTs from 2500 to 6000 K and can vary by up to 123 lx at a fixed CCT (e.g., 196 to 319 lx at 5000 K). The range of achievable mel-EDI increases as CCT increases and, on average, decreases as color fidelity, characterized with IES TM-30 Rf, increases. These data demonstrate that there is no easy mathematical conversion between CS and mel-EDI when a spectrally diverse spectra set of spectral power distributions is considered.

60 APPLIED LIFE SCIENCES↗

Comparing Measures of Average Color Fidelity

The introduction of new measures of color rendition, especially IES TM-30-15, has stirred debate within the lighting industry on the relative merits of the tools, as well as the amount of difference between the new tools and prior tools, such as CIE Ra. This article focuses on comparing three measures of average color fidelity: IES Rf, CIE Ra, and CIE Rf. Using a large set of commercially-available, experimental, and theoretical spectral power distributions (SPDs), the analysis contrasts past efforts to make similar comparisons using smaller or more focused datasets. It highlights the interactive effect of gamut shape and color space non-uniformity, which results in a range of IES Rf values of at least to 50 to 86 for SPDs having a CIE Ra value of 80. It also examines how these differences can be overlooked in psychophysical experiments relying on a small number of SPDs, which can present misleading findings on the value and meaning of the measures. When considering the results, it is important to remember that average color fidelity is only one aspect of color rendition.

Royer, Michael P.↗

Comparing Measures of Gamut Area

This article examines how the color sample set, color space, and other calculation elements influence the quantification of gamut area. The IES TM-30-18 Gamut Index (Rg) serves as a baseline, with comparisons made to several other measures documented in scientific literature and 12 new measures formulated for this analysis using various components of existing measures. The results indicate that changes in the color sample set, color space, and calculation procedure can all lead to substantial differences in performance characterization. However, it is impossible to determine the relative “accuracy” of any given measure, because gamut area is not directly correlated with any subjective evaluation of color quality. Nonetheless, the utility of different approaches can be weighed based on the merits of individual components of the gamut area calculation and based on the ability of a measure to provide useful information within a complete system for evaluating color rendition. Foremost, the components of a measure of gamut area must be compatible with the needs of other measures of color rendition, so that effective comprehensive models can be established, allowing for tradeoffs between different characteristics to meet application demands. For gamut area measures specifically, it is important to have a reasonably uniform distribution of color samples across hue angle with sufficient quantity to ensure robustness but enough difference to avoid incidents of the hue-angle-order of the samples varying between the test and reference condition. This can also be achieved with larger sample sets by deriving average conditions within hue-angle bins.

Royer, Michael P.↗

Readying for a Color-Mixed Future Luminous Efficacy on the Horizon

If history repeats itself, lighting 20 years from now will be substantially different than what it is today. Twenty years ago, LEDs were a novelty, not quite ready for use in architectural lighting systems. A little more than 20 years before that, rare-earth tri-phosphor T8 fluorescent lamps were beginning to replace broadband halophosphate T12 fluorescent lamps, which themselves became the predominant source of lumens in the United States around the middle of the last century. At each step in this evolution, new lighting metrics have been developed to address differences in performance, and they in turn guided technology development. For example, in the 1960s, it was CRI and CCT, and more recently it has been LM-79 and TM-30.

Royer, Michael P.↗

Relative Contributions of sc-DER, mel-DER, Color Rendition, Chromaticity, and Illuminance to Spatial Brightness Perception

An experiment was conducted to examine spectrally based factors that contribute to the visual perception of interior environments, with a focus on brightness perception. Thirty-two participants evaluated 60 different lighting scenes in a mock office. The lighting spectral power distributions varied systematically in illuminance, chromaticity (CCT and Duv), s cone opic daylight efficacy ratio (sc-DER), melanopic daylight efficacy ratio (mel-DER), and color rendition (R f , R g , and R cs,h1 ). At the operationalized levels of these variables, illuminance had the largest effect on brightness perception. Notably, the second largest effect was due to changes in red chroma (R cs,h1 ). The effect of sc-DER was also statistically significant but was a tertiary effect. The effects of mel-DER, CCT, and Duv were not statistically significant. This large effect of red chroma is consistent with the existing understanding that changes in color perception are often perceived when illuminance changes. In conclusion, with appropriate changes in color rendition and other factors held constant, spatial brightness perception was preserved through a decrease from 500 lux to 250 lux.

42 ENGINEERING↗