Search NASA⌕ Search

SEARCH · Search NASA

Results for “TOMOGRAPHIC GAMMA SCANNER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Self-Absorption Corrections for Plutonium Measurements With the Tomographic Gamma Scanner - 17325

The Tomographic Gamma Scanner (TGS) is a Non-Destructive Assay (NDA) instrument that combines high-resolution gamma spectroscopy with low spatial resolution three-dimensional image reconstruction in order to reduce bias and improve precision for measurements of drummed waste. The TGS technique is especially suited to measure containers with non-uniform source distributions and low-to me-dium-density heterogeneous matrices, compared with traditional NDA methods. Canberra recently built, installed, and commissioned a TGS system, intended primarily for the measurement of plutonium (Pu) bearing waste, at a European nu-clear fuel reprocessing facility. Pu assays using the TGS technique present technical challenges distinct from those typically encountered in traditional LLW applications. Among these is the need to apply corrections for self-absorption effects that occur on scales smaller than the TGS spatial resolution, and can compromise the assay result if not included in the TGS imaging methodology. We present a brief review of the Self Absorption Correction (SAC) technique, and discuss the complications involved with its application to the TGS methodology with examples from our recent experience. This work continues a Canberra history of further developing and refining a technique to solve emerging problems, having commercialized the original methodology by partnering with the research institution that pioneered it. The TGS and the SAC methodologies were originally developed by Los Alamos National Laboratory (LANL) and John Fleissner respectively, and this work illustrates how Canberra has implemented an advancement of these techniques in a new TGS system. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Resolution Scanning Configurations for the Canberra Tomographic Gamma Scanner - 17323

The Canberra Tomographic Gamma Scanner (TGS) is a Non-Destructive Assay (NDA) system that combines high resolution gamma ray spectroscopy (HRGS) with low-spatial-resolution imaging for the measurement of heterogeneous drummed waste with matrix densities in the range of 0 to 1 g/cc. The TGS methodology uses a two-pass scanning protocol; a 10-15 μCi {sup 152}Eu transmission source is used to interrogate density and composition of the matrix in the first pass, and passive gamma ray spectroscopy is used to collect emission spectra in the second, while the drum is rotated and translated to vary the view path. In standard implementations, the transmission and emission data are used to reconstruct three dimensional images of the matrix and activity distribution inside the drum on a 10x10x16 grid of discrete volume elements or 'voxels'. These images allow attenuation corrections to be calculated and applied on a view by view, and voxel by voxel basis, reducing the over- and under-correction biases obtained by assay techniques which assume homogeneous distributions of material. The most recent TGS system deployed by Canberra featured, among other new developments, the ability to perform higher resolution image re-construction, which may prove beneficial for the assay of more highly mixed matrices or oddly shaped assay items within a container. These additional scanning protocols reconstruct the image data into 14x14 and 20x20 voxel grids, using a smaller collimator aperture size. The hardware and software implementations of these higher resolution scans are discussed, and the calibration and initial evaluations of performance are presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tomographic Gamma Scanner Experience: Three Cases

This is a summary of field applications of tomographic gamma scanning (TGS). Three cases are shown: enriched uranium scanning at Rocky Flats, heat-source plutonium at LANL, and plutonium-bearing pyrochemical salts at Rocky Flats. Materials are taken from the references shown below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-C-201-07: Validation of a GATE Gamma Camera Model for the Siemens Symbia

Purpose: To develop a simulation model of a clinical gamma camera/SPECT system and to validate the model using experimental and published measurements from the clinical system. Methods: Geant4 Application for Tomographic Emission (GATE) was used to create a model of the Siemens Symbia gamma camera. A modular model was implemented that allows specifying combinations of crystal thickness (3/8”, 5/8”) and collimator (LEHR, MELP, HE). Shielding, energy resolution, intrinsic resolution, crystal thickness, and collimator properties were set based on manufacturer specifications. Validation of the model was performed by simulating NEMA 2007 gamma camera tests including spatial resolution and sensitivity for Tc99; these were compared with experimental and published data for the scanner. The simulated energy spectra of a Tc99 line source in acrylic blocks was visually compared with the corresponding experimental acquisition. For a 4 cm diameter sphere filled with Tc99, the attenuation maps were generated from simulation data, and the photopeak and scatter window were extracted from GATE output using ROOT to create DICOM files to use in the clinical reconstruction. Results: Simulated spatial resolutions for LEHR 3/8” crystal at 0, 10 cm, 10 cm (with scatter), and 30 cm were 4, 6.7, 7.9, and 14.5 mm FWHM; these were 9% less than published data. For 5/8” crystal the spatial resolutions were 4.5, 7.0, 8.5, and 14.7 mm FWHM; these were 4% to 10% less than published data. Simulated sensitivity was within 3.5% of published data for both LEHR 3/8” and 5/8”. The simulated energy spectra matched the photopeak and scatter window well, but did overestimate the counts below 90 keV. The simulated attenuation map and projection data were successfully reconstructed with the clinical software, and the passed visual inspection. Conclusions: Validation of a specific clinical scanner allows future studies of quantification accuracy for both planar and SPECT imaging. Research reported in this publication was supported by the National Cancer Institute of the National Institutes of Health under Award Number R01CA138986. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.

60 APPLIED LIFE SCIENCES↗

X-ray tomographic in-service inspection of girth welds - The European project TomoWELD

The new standard 'ISO 17636-2:2013: Non-destructive testing of welds - Radiographic testing - Part 2: X- and gamma-ray techniques with digital detectors', defines the practice for radiographic inspection of welded pipes for manufacturing and in-service inspection. It is applied in Europe for inspections of pipe welds in nuclear power plants as well as in chemical plants and allows a faster inspection with digital detector arrays (DDA) than with film. Nevertheless, it does not allow the evaluation of the depth and shape of volumetric and planar indications. In 2001 a planar tomography scanner, TomoCAR, was introduced for mechanized radiographic testing (RT) inspection and non-destructive measurement of cross sections. The project TomoWELD is based on a new concept of the scan geometry, an enhanced GPU based reconstruction, and the application of a new generation of photon counting DDAs based on CdTe crystal CMOS hybrids. The new detector permits the selection of energy thresholds to obtain an optimum energy range and reduction of the influence of scattered radiation. The concept and first measurements are presented. Flaw depth and shape of volumetric and planar irregularities can be determined.

36 MATERIALS SCIENCE↗

Computed Tomography of Dry Cask Storage for Used Fuel

The demand for dry cask storage for used nuclear fuel is on the rise due to the continuous operation of currently existing nuclear plants which are reaching or have reached the capacity of their used fuel pools. Dry cask storage allows used fuel that has already been cooled in the used fuel pool for at least five years to be surrounded by an inert gas inside a specially designed and licensed cask. Currently, 75 of the 78 U.S.A reactor sites either have or are pursuing an independent spent fuel storage installation (ISFSI) for dry cask fuel storage with over 2,000 casks already loaded. Cask loading will only continue to increase until a final repository solution is operational or the U.S. begins to recycle fuel. The challenge of monitoring the condition of the used fuel inside the cask without exposing the used fuel has been apparent since the 1980's. The objective of the University of Florida (UF) project is ultimately to investigate the feasibility of imaging the used fuel assemblies' location and evaluating the inner structural condition using emission source computed tomography (CT). A combination of radiation transport models will be used to simulate gamma-rays and neutrons traversing through the used fuel, structure, and cask body materials. In the simulations, multiple linear detector arrays will record the radiation outside the cask wall and will be placed at various angles in order to model rotating a linear detector array around the entire cask. The combination of data from all the detectors will give the planar radiation projection onto the detectors, more commonly called the Radon transform, of the structure of used fuel assemblies. This project can be processed with filtered back projection or other more advanced reconstructive imaging algorithms to recreate the fuel structures. A majority of the historical work done for used fuel has been on verification, diversion detection, and burnup credit validation in order to meet regulatory guidelines. One of the more commonly used systems for single assembly verification is the Fork Detector developed at Los Alamos National Laboratory in 1988. A group at the Idaho National Laboratory developed a Compton Dry-Cask Imaging Scanner that has the ability to detect empty vs full storage positions but it suffered a setback when transported to the Doel Nuclear Power Plant near Antwerp, Belgium; the system was unable to detect full energy peaks because of the additional scattering caused by a thick ballistic steel shield. As detectors, computational power, and modeling improves, a few groups have leveraged these advancements and started to investigate CT hoping, that despite the difficulties, the technique can give information on fuel condition. So far the groups have mostly limited the tomographic work to a per assembly basis , rather than the full dry cask as the University of Florida plans to investigate. The downsides of CT versus simpler verification and validation are the amount of data required and the time it takes to acquire that data. Given that dry casks are intended to sit undistributed for up to 60 years, a scanning time of several weeks to several months is not unreasonable if such systems do not require human operators beyond the initial setup. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Computed Tomography of Dry Cask Storage for Used Fuel

The demand for dry cask storage for used nuclear fuel is on the rise due to the continuous operation of currently existing nuclear plants which are reaching or have reached the capacity of their used fuel pools. Dry cask storage allows used fuel that has already been cooled in the used fuel pool for at least five years to be surrounded by an inert gas inside a specially designed and licensed cask. Currently, 75 of the 78 U.S.A reactor sites either have or are pursuing an independent spent fuel storage installation (ISFSI) for dry cask fuel storage [1] with over 2,000 casks already loaded [2]. Cask loading will only continue to increase until a final repository solution is operational or the U.S. begins to recycle fuel. The challenge of monitoring the condition of the used fuel inside the cask without exposing the used fuel has been apparent since the 1980s. The objective of the University of Florida (UF) project is ultimately to investigate the feasibility of imaging the used fuel assemblies’ location and evaluating the inner structural condition using emission source computed tomography (CT). A combination of radiation transport models will be used to simulate gamma-rays and neutrons traversing through the used fuel, structure, and cask body materials. In the simulations, multiple linear detector arrays will record the radiation outside the cask wall and will be placed at various angles in order to model rotating a linear detector array around the entire cask. The combination of data from all the detectors will give the planar radiation projection onto the detectors, more commonly called the Radon transform, of the structure of used fuel assemblies. This project can be processed with filtered back projection or other more advanced reconstructive imaging algorithms to recreate the fuel structures. A majority of the historical work done for used fuel has been on verification, diversion detection, and burnup credit validation in order to meet regulatory guidelines. One of the more commonly used systems for single assembly verification is the Fork Detector developed at Los Alamos National Laboratory in 1988 [3]. A group at the Idaho National Laboratory developed a Compton Dry-Cask Imaging Scanner that has the ability to detect empty vs full storage positions but it suffered a setback when transported to the Doel Nuclear Power Plant near Antwerp, Belgium; the system was unable to detect full energy peaks because of the additional scattering caused by a thick ballistic steel shield [4]. As detectors, computational power, and modeling improves, a few groups have leveraged these advancements and started to investigate CT hoping, that despite the difficulties, the technique can give information on fuel condition. So far the groups have mostly limited the tomographic work to a per assembly basis [5] [6] [7], rather than the full dry cask as the University of Florida plans to investigate. The downsides of CT versus simpler verification and validation are the amount of data required and the time it takes to acquire that data. Given that dry casks are intended to sit undistributed for up to 60 years, a scanning time of several weeks to several months is not unreasonable if such systems do not require human operators beyond the initial setup.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗