Some Sources of Contaminants in the Shuttle Bay Measured with Temperature-Controlled Quartz Crystal Microbalances (TQCM)

The sources of molecular deposits on a Temperature-Controlled Quartz Crystal Microbalance (TQCM) attached to the shuttle bay wall at some distance from the payload and pointing out of the bay have been investigated. Explored as possible sources are: (1) the outgassing of the shuttle tiles treated with the water proofing di-methyl-ethoxy-silane (DMES) compound, scattered back by the ambient molecules into the bay; (2) The ambient scattered return flux of the outgassing, from the RTV 560 silicone which is used as the adhesive for the tiles; (3) the ambient scattered return flux of the payload outgassing; (4) the return C, flux from outgassing source originating near, below, or adjacent to the package containing the TQCM; and (5) the self-scattering of venting plumes and outgassing above the monitor package depositing on the TQCM. In all of these sources, the magnitudes of the outgassing, of the leakage rates, and venting had to be estimated in the absence of data. The resulting analyses which can be useful for similar investigations, indicates that the outgassin- from the tiles, the RTV, the payloads, or the shuttle may not have been the sources of the deposit (about 1 micro g/cm(sup 2) during a the period from bay door opening and payload release from the bay). It appears more probable that the origin is the self- and/or ambient-scattered return fluxes originating near, below, or internal to the monitor package.

Scialdone, John J.↗

Analysis of TQCM surface contamination adsorbed during the Spacelab I Mission

The Temperature-Controlled Quartz Crystal Microbalance (TQCM) system was flown on the Spacelab I Mission as part of the Induced Environment Contamination Monitor to monitor surface contamination (SC) in the payload bay. SC on the five sensors of the TQCM was analyzed by means of IR spectroscopy, scanning electron spectroscopy, and energy dispersive X-ray fluorescence. The amount of SC ranged from 1.4 micrograms/sq cm for the -Z sensor to 39.9 micrograms/sq cm for the +X sensor. The IR analysis showed strong CH2, CH3, and carbonyl absorption bands, indicative of ester and polyester compounds found in adhesives, plasticizers, and tape. The particulates (mostly ranging from 1 micron to 20 microns in size) were mainly composed of Mg, Al, Al2O3, and Si, and probably originated in the solid rocket firings.

Mckeown, D.↗

Improved materials characterization for spacecraft applications

A material outgassing test consists of an effusion cell, mass spectrometer, and thermally controlled quartz crystal microbalance (TQCM). The material sample is placed in the effusion cell at a predetermined temperature, and the sample is outgassed in a vacuum of 0.000001 torr range. The total outgassing mass as a function of time is determined with the TQCM which is cooled to LN2 temperatures. Based on the view factor of the TQCM, the total outgassed mass can be determined. The technique can be verified by comparing the results to the actual mass loss of the sample which is determined by hanging the diffusion cell from the Cohn microbalance. The mass spectrometer can be used to determine if there are any low molecular weight components outgassing, such a nitrogen which does not condense on the TQCM. After the material outgasses to a point of saturation, the effusion cell is closed off, and the TQCM is slowly heated to allow the condensed film to be broken down into its components. As the temperature is increased, the components evaporate from the surface at a different rate and can be detected with the mass spectrometer. The relative amount of each component is found by the change in frequency of the TQCM as the component evaporates. Hence, from this test, not only is isothermal kinetic data obtained, but the primary components can also be identified in terms of their molecular weight.

Cull, R.↗

Outgassing Measurements for Three Materials, Combined with Vacuum Ultraviolet Radiation Illumination of the Volatile Condensable Materials

The photolysis of three organic materials, by vacuum ultraviolet (VUV) radiation, has been quantified using 15-MHz temperature-controlled quartz microbalances (TQCM's). The rate at which molecular species, released from the individual samples, condensed on two TQCM s was measured for periods of up to 139.9-hours. The individual samples were heated in an effusion cell and the emitted molecular species collected on a pair of TQCM's which were maintained at -40 degrees Celsius. At several points during the deposition measurement, the deposition surface of one TQCM was illuminated by a 30 Watt deuterium lamp, and the loss of material from that surface was observed. V W illumination of the TQCM, concurrent with condensation, reduced the rate that material was lost from the deposition surface. These measurements present a contrasting picture of molecular deposition, in the presence of VUV, to that presented by other investigators who observed an enhanced rate of molecular deposition, when the deposition surface was illuminated by VUV.

Albyn, Keith↗

Using a temperature-controlled quartz crystal microbalance in a space equipment cleanroom to monitor molecular contamination

There is a need for continuous monitoring for molecular contamination in clean rooms where spaceflight equipment is assembled, integrated, and tested to insure that contamination budgets are met. The TQCM (temperature-controlled quartz crystal microbalance) can be used to provide both a real time warning and a cumulative measurement of molecular contamination. It has advantages over the other measurement methods such as witness mirrors, NVR (non-volatile residue) plates, and gas analyzers. A comparison of the TQCM sensitivity and ease of operations is made with the other methods. The surface acoustic wave microbalance (SAW), a newly developed instrument similar to TQCM, is considered in the comparison. An example is provided of TQCM use at Goddard Space Flight Center when the Wide Field Planetary Camera 2(WFPC-2) and the Corrective Optics Space Telescope Axial Replacement (COSTAR) were undergoing integrated testing prior to their installation in the Hubble Space Telescope on its first servicing mission. Areas for further investigation are presented.

Mitchell, William J.↗

OSS-1/contamination monitor

A 20-cm high, 18-cm wide, and 30-cm long (8x7x12 inch) box weighing about 7 kg (15 lbs) and consuming about 7 watts of power was carried on the OSS-1 pallet to monitor the mass build-up or accretion of condensible, volatile materials on surfaces in the shuttle bay during all phases of ascent, on-orbit, and descent. Passively thermally controlled, the box holds two witness samples and four actively temperature controlled quartz crystal microbalances (TQCM) whose temperature can vary from -60 C to +80 C. Graphs show the accretion indicated by the TQCM during the launch and early orbital phase. Conditions during tail to the Sun, nose to the Sun, and bay to the Sun attitudes of the shuttle during STS-3 are reflected in temperatures indicated by the OSS-1 thermistor. These temperatures influence outgassing rates of various materials as well as measurements made by the contamination monitor package. The parameters that bear on TQCM measurements data are shown in graphs and discussed.

Kruger, R.↗

Temperature-controlled quartz crystal microbalance measurements on Space Transport System (STS-2)

The purpose of the Temperature-Controlled Quartz Crystal Microbalance (TQCM) system on STS-2 was to measure condensible molecular flux in the payload bay of the Space Shuttle as a function of temperature, direction, and time. Five quartz crystal microbalance sensors were located in the IECM to measure molecular adsorption in each of the Orbiter axes, +X (fore), -X (aft), +Y (starboard), -Y (port), and -Z (up, perpendicular to payload bay). The temperature of each sensor was controlled by a thermoelectric device so contamination could be measured as a function of four preset temperatures: +30, 0, -30, and -60 C. When orbital altitude was reached, the TQCM sensors began their orbital measuring cycle routine. The sensors were commanded to 80 C for 30 min, which was used as an initial clean-up. They were then stepped through a program of 2-nr collection periods at each temperature with a 30-min, 80 C period between each collection period. The collection periods progressed in descending order from +30 to -60 C and, then the cycle was repeated. Since the STS-2 orbital phase lasted approximately 53 hrs, the TQCM system completed four cycles and was in the fifth when the mission was terminated.

Fountain, J. A.↗

Results from a 'small box' realtime molecular contamination monitor on STS-3

On the basis of early estimates of the Shuttle induced environment, Scialdone (1979) concluded that in the vicinity of the cargo, the cargo would have the largest influence on the environment. As a contamination control device, realtime monitors can indicate safe operational periods for sensitive attached payloads. It was, therefore, decided to develop the OSS-1/Contamination Monitor Package (CMP) experiment which was seen as a forerunner of an operational monitor. A description of the CMP is provided, taking into account four actively temperature controlled quartz crystal microbalances (TQCM). The TQCM temperatures could be varied from -60 C to +80 C. The sensor consisted of a matched pair of quartz crystals. The crystals were designated as a sensor and reference crystal. Results obtained during the STS-3 mission are discussed. These results show the feasibility and advantages of a small real-time contamination monitor.

Triolo, J.↗

Design/Use of the Remotely Operated Bakeout Box Shutter (ROBBS)

A thermal vacuum box bakeout and certification allows orbital payloads to be cleaned and certified when the background TQCM measurements (a measure of how much molecular contamination is on a payload or chamber) are unacceptable or unmanageable in the standard thermal vacuum chamber. The box bakeout procedure is usually performed in 4 steps: bakeout the box, certify the box, bake out the payload, and finally certify the payload. In the procedure's current setup, the contaminant conduction hole ("lid") is initially open and a vacuum chamber break must occur between the bakeout and certification phases to close the box from the vacuum chamber. This exposure is necessary to allow the outgassed contaminants to escape the box's volume rapidly during bakeout phase, but payload certification isn't usually performed while the lid is still open, because it exposes the payload, TQCM, and box volume to chamber contaminants. The Remotely Operated Bakeout Box Shutter (ROBBS) is a new facility design and will allow the remote closure of the contamination hole while the chamber is still under vacuum, and with little or no time to do so.

Ottens, Brian P.↗

Three-Dimensional Vibration Isolator for Suppressing High-Frequency Responses for Sage III Contamination Monitoring Package (CMP)

The Stratospheric Aerosol and Gas Experiment (SAGE) III - International Space Station (ISS) instrument will be used to study ozone, providing global, long-term measurements of key components of the Earth's atmosphere for the continued health of Earth and its inhabitants. SAGE III is launched into orbit in an inverted configuration on SpaceX;s Falcon 9 launch vehicle. As one of its four supporting elements, a Contamination Monitoring Package (CMP) mounted to the top panel of the Interface Adapter Module (IAM) box experiences high-frequency response due to structural coupling between the two structures during the SpaceX launch. These vibrations, which were initially observed in the IAM Engineering Development Unit (EDU) test and later verified through finite element analysis (FEA) for the SpaceX launch loads, may damage the internal electronic cards and the Thermoelectric Quartz Crystal Microbalance (TQCM) sensors mounted on the CMP. Three-dimensional (3D) vibration isolators were required to be inserted between the CMP and IAM interface in order to attenuate the high frequency vibrations without resulting in any major changes to the existing system. Wire rope isolators were proposed as the isolation system between the CMP and IAM due to the low impact to design. Most 3D isolation systems are designed for compression and roll, therefore little dynamic data was available for using wire rope isolators in an inverted or tension configuration. From the isolator FEA and test results, it is shown that by using the 3D wire rope isolators, the CMP high-frequency responses have been suppressed by several orders of magnitude over a wide excitation frequency range. Consequently, the TQCM sensor responses are well below their qualification environments. It is indicated that these high-frequency responses due to the typical instrument structural coupling can be significantly suppressed by a vibration passive control using the 3D vibration isolator. Thermal and contamination issues were also examined during the isolator selection period for meeting the SAGE III-ISS instrument requirements.

Li, Y.↗

Hubble space telescope component qualification utilizing a residual gas analyzer

An approach is described for integrating an automated residual gas analyzer (RGA) into the thermal vacuum outgas process. The RGA has the capability of detailed analysis over a 200 amu range with monitoring of each peak as the test progresses. The NASA criterion of either a 50% reduction of each peak over 44 amu or less than an 0.1% amplitude of the 28 amu base peak for all amu's above 44 amu is satisfied. A computer sorts, reports which peaks do not satisfy the criterion, and reports test completion. The computer plots amplitudes of all the peaks from 1 amu through 200 amu for each scan. This RGA real time approach is unique in that it provides sufficient detail to highlight a problem as it occurs. By comparison, a quartz crystal microbalance (QCM) or a thermoelectric quartz crystal microbalance (TQCM) indicates to the operator when changes occur, but not what has happened. Optical witness samples indicate whether a test was satisfactory within a few days after the test was completed.

Westfall, A. H.↗

Condensation Of Volatile Contaminant In An Instrument

Report describes investigation of deposition of contaminant of cooled optical detectors in Wide-Field/Planetary Camera (WF/PC), an instrument in Hubble Space Telescope. To understand phenomenon, initially thought to be deposition of water from graphite/epoxy optical-bench material in instrument, researchers mounted several diagnostic instruments on access plate to monitor interior of WF/PC housing and optical bench. Temperature-controlled quartz-crystal microbalance (TQCM) measures adsorbed and desorbed volatile condensible material on surfaces in WF/PC.

Hansen, Patricia A.↗

The Design of a Remotely Operated Shutter (ROS) for Thermal Vacuum Testing

Space-flight hardware is required to meet specific outgassing criteria under vacuum conditions in order to reduce the risk of contaminating sensitive optics and spacecraft components. Under certain circumstances, it is desirable to measure the contamination levels that are being released from all surfaces of the test payload. This certification is often accomplished with a Total Outgassing Measurement (TOM) box. The TOM box has one 103.2 square centimeter (16 square inch) opening and one 4.84 square centimeter (0.75 square inches) opening. The larger opening allows contaminants to easily escape the box during the hardware bakeout phase. The smaller opening provides a limited conductance path for outgassed contaminants during the certification phase. A Thermoelectric Quartz Crystal Microbalance (TQCM) monitors the contamination levels inside the box to provide the total outgassing measurement. During transition from the bakeout phase to the certification phase, the TOM box is reconfigured to close the larger opening. For previous certifications, the vacuum chamber was returned to ambient conditions and the larger conductance port was closed manually. The ROS system eliminates the need to enter the chamber by remotely closing the large TOM box opening. Substantial schedule and cost savings are achieved through the use of this system. The ROS system consists of three main components; a shutter, a motion actuator, and an actuator controller. Each of these components was selected or designed to operate in an extreme-temperature and vacuum environment while providing a high level of reliability. Different types of motion actuators were considered for driving the shutter. Design parameters for the actuator included material properties, force capability, reliability, and cost.

Hale, Kathleen L.↗

LETS: Lunar Environments Test System

The Environmental Effects Branch (EM50) at the Marshall Space Flight Center has developed a unique capability within the agency, namely the Lunar Environment Test System (LETS). LETS is a cryo-pumped vacuum chamber facility capable of high vacuum (10-7 Torr). LETS is a cylindrical chamber, 30 in. (0.8 m) diameter by 48 in. (1.2 m) long thermally controlled vacuum system. The chamber is equipped with a full array of radiation sources including vacuum ultraviolet, electron, and proton radiation. The unique feature of LETS is that it contains a large lunar simulant bed (18 in. x 40 in. x 6 in.) holding 75 kg of JSC-1a simulant while operating at a vacuum of 10-7 Torr. This facility allows three applications: 1) to study the charging, levitation and migration of dust particles, 2) to simulate the radiation environment on the lunar surface, and 3) to electrically charge the lunar simulant enhancing the attraction and adhesion of dust particles to test articles more closely simulating the lunar surface dust environment. LETS has numerous diagnostic instruments including TREK electrostatic probes, residual gas analyzer (RGA), temperature controlled quartz crystal microbalance (TQCM), and particle imaging velocimeter (PIV). Finally, LETS uses continuous Labview data acquisition for computer monitoring and system control.

Vaughn, Jason A.↗

Contamination Control Assessment of the World's Largest Space Environment Simulation Chamber

The Space Power Facility s thermal vacuum test chamber is the largest chamber in the world capable of providing an environment for space simulation. To improve performance and meet stringent requirements of a wide customer base, significant modifications were made to the vacuum chamber. These include major changes to the vacuum system and numerous enhancements to the chamber s unique polar crane, with a goal of providing high cleanliness levels. The significance of these changes and modifications are discussed in this paper. In addition, the composition and arrangement of the pumping system and its impact on molecular back-streaming are discussed in detail. Molecular contamination measurements obtained with a TQCM and witness wafers during two recent integrated system tests of the chamber are presented and discussed. Finally, a concluding remarks section is presented.

Snyder, Aaron↗