Search NASA⌕ Search

SEARCH · Search NASA

Results for “TRANSDUCER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Transducer driving methods and transducer driving systems

Transducer driving methods and transducer driving systems are described. According to one aspect, a transducer driving method includes providing a plurality of initial driving signals to a transducer, wherein each of the initial driving signals has a respective one of a plurality of different frequencies, identifying one of the frequencies where the transducer has a reduced impedance as a result of the provision of one of the initial driving signals having the one frequency to the transducer compared with impedances of the transducer resulting from the provision of others of the initial driving signals having others of the frequencies to the transducer, determining that the identified one of the frequencies is not acceptable for driving the transducer, as a result of the determining, identifying another of the frequencies, and driving the transducer using another driving signal having the another frequency.

Myjak, Mitchell J.↗

Liquid metallic laser ultrasound transducer for high-temperature applications

This study aims to investigate a laser ultrasound (LUS) transducer for high-temperature (>100 °C) applications. For decades, many researchers have investigated efficient LUS transducers, yet studies on laser ultrasound transducers capable of performing at the high-temperature condition are rarely found in the literature. Most current LUS transducers still utilize a polymer-based composite material, that is, not stable at varying temperature conditions. This study introduces a liquid metallic (LM) LUS transducer that utilizes field's metal, which has a high thermal expansion (~3 × 10 -4 K -1 ). We hypothesized that such a high thermal expansion of the liquid metal can effectively produce laser-generated ultrasound waves, substituting for conventional polymer-based transducers. A numerical simulation predicted that the LM LUS transducer would produce higher LUS intensity (~22 dB) than that without the LUS transducer. Experiment results confirmed that the LM transducer effectively intensifies the ultrasound wave signals, obtaining a signal-to-noise gain over 30 dB. Moreover, the transducer was found capable of transmitting detectable wave packets in relatively high-temperature conditions (~400 °C), while conventional candle soot nanoparticle-polydimethylsiloxane could not perform stably at these elevated temperatures. The investigations introduced in this article are scientifically significant since we demonstrated the engineering feasibility of liquid metallic materials for LUS transducers.

47 OTHER INSTRUMENTATION↗

Pressure Transducer Measurement Variability in Deep Wells Screened Across the Water Table

Abstract Automated water level measurements collected using vented pressure transducers in deep wells screened across the water table may exhibit a greater response to barometric pressure changes than the true water level. The cause was hypothesized to be disequilibrium in barometric pressure between the wellbores and land surface due to air exchange with the deep vadose zone. In this study, vented and nonvented pressure transducers were installed and operated simultaneously in two deep wells screened across the water table. A vent tube open to the atmosphere at land surface allowed for barometric compensation of the vented transducers. Two nonvented transducers were installed in each well, one submerged in the water and one above the water surface. The difference in readings allowed for barometric compensation. Manual measurements were also collected. It was confirmed that measurements from the vented transducers exhibited greater variability in response to barometric pressure changes than the nonvented transducers and manual measurements. Comparison of the downhole barometric pressure measurements to values from a nearby meteorology station showed the response in the wells to changes in barometric pressure was time‐lagged and attenuated. Thus, the reference pressure from land surface supplied to the vented transducers was not representative of the air pressure within the wells. This caused fluctuations of the transducer readings in response to barometric pressure changes to be greater than the true water level change. This issue can be resolved by the use of nonvented pressure transducers.

McDonald, John P.↗

Final Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have developed a continuum electromechanics model of the microwave resonant cavity transducer performance. The deflection of the membrane is calculated using equations from the theory of plates and shells for deflection of radially constrained thin circular disk under uniform load. The microwave frequency shift is calculated using the equations from the microwave cavity perturbation theory. The transducer model was validated with proof-of-concept experimental data of water flow sensing with a Brass 360 right circular cylinder with 22.2mm diameter and 203µm thick wall. The cavity was excited through a subwavelength hole in TE 011 mode with resonant frequency f ≈ 17.8GHz. Subsequently, we have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment. For this test, we have developed a cylindrical resonator with the same dimensions as for the Brass 360 cavity. The resonator for high temperature liquid sodium test was machined from stainless steel 316 and electroplated with silver on the interior surfaces. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. The sodium flow sensing study was performed in a liquid sodium vessel at 340°C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred kHz was observed. The transducer was removed after 70 days of testing. No visual damage was observed, and the electromagnetic response remained the same. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Water flow sensing was performed before and after liquid sodium test. The responses in both cases are similar and agree with COMSOL computer simulations. Because long-term (multi-year) experimental tests of transducer resilience to harsh environment are not practical, we have developed a probabilistic model of creep to estimate transducer resilience to the harsh environment. The probabilistic model considers diffusion creep under the condition of high temperature and low stress, where the stress and temperature are allowed to be random variables with Gaussian distributions. Using the probabilistic model, we estimate inelastic membrane deflections due to creep for several temperature ranges. We conclude that for temperatures less than 650°C, creep has negligible long-term effect on the transducer performance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effect of sintering temperature on adhesion of spray-on piezoelectric transducers

Conventionally sol-gel spray-on transducers require a high-temperature (> 700 ◦C) sintering process; however, this process can affect the microstructure of the substrate material. For mechanical elbows and valves utilized for fluid transport in the energy sector, the components are designed to have a specific microstructure, and deviations from these specifications can create weak points in the system. For this reason it is important to investigate how the temperature of the deposition process affects the substrate. This paper investigates the effect of high-temperature and low-temperature (< 150 ◦C) processing conditions on the surface composition of the substrate. Furthermore, the resultant transducers from high- and low-temperature fabrication processes are compared to determine if a low-temperature processing method is feasible. For these studies a sol-gel spray-on process is employed to deposit piezoelectric ceramics onto a stainless-steel 316L substrate. Energy-dispersive X-ray spectroscopy is utilized to determine the composition of the substrate surface before and after transducer deposition. Results indicate that the high-temperature processing conditions may alter the surface composition of the metal due to a diffusion of the metal into the ceramic, which results in a metal surface that is bonded to the ceramic. Furthermore, it is shown that low-temperature processing of spray-on transducers is a viable method for transducer fabrication where the resultant transducers meet the industry minimum requirement of 30 dB signalto-noise ratio. In parallel simulation calculations, finite-element method (FEM) studies were performed to model the adhesive strength of the low-temperature processed transducer to the substrate surface. Comparisons between the simulations and experiments suggest that the bond strength is much greater than the commercial gel bonds and closer to hardened epoxy glue bonds. These results indicate that spray-on transducers fabricated under lowtemperature processing conditions are a viable solution for leave-in-place monitoring of structures.

M. Sinding, Kyle↗

Second Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. Because the transducer is intended for immersion in a high temperature corrosive fluid, understanding of material degradation is crucial for estimation of transducer performance lifetime, and development of measurement interpretation algorithms. We conducted a preliminary computational investigation of relevant damage mechanisms of a stainless steel 316 cylindrical resonator in FLiBe salt. The two main damage mechanisms, creep and corrosion, were modeled using multiphysics COMSOL software. Degradation was modeled for a temperature range 500°C to 700°C. Coupling of the damage mechanisms was not considered. These models predict significant inelastic deformation at most temperatures due to creep, and qualitatively predict chromium depletion both along the liquid/solid interface and along the grain boundaries. An algorithmic approach for compensation of these degradation effects during fluid flow measurements will be developed in the future work. To validate sensor physics, we have performed proof-of-principle test of flow sensing in water. For this test, we have developed a cylindrical resonator for K-band, which was machined from brass. The cavity was excited through WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder. To increase the spectral signal visibility, we developed a signal processing method for baseline subtraction. A flow loop for proof-of-principle test of transducer performance in water was assembled. A commercial flow meter was installed in the loop for reference measurements. Cylindrical cavity was excited in the TE 011 mode with resonant frequency f ≈ 17.8GHz. Frequency shift of cavity spectral response was obtained by gradually increasing water flow rate from 0 to 60gpm. Corresponding monotonic increase of resonant frequency shift by several MHz was observed. Approximate figure of merit of sensitivity to flow rate is 100KHz/GPM. In addition, we have identified an existing liquid sodium experimental setup for demonstration of flow sensing in environment similar to that of an advanced reactor. The setup consists of a cylindrical vessel and center feed line, where transducer inserted through the lid will measure velocity of the impinging liquid jet. As a calibration experiment, we have assembled a water vessel with center feed with the same dimensions as those of the liquid sodium setup. We have also developed and insertion probe consisting of a 50cm brass waveguide enclosed in protective SS316 tube. Using the water loop, we have demonstrated feasibility of sensing the impinging liquid jet in the vessel.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Progress Towards Developing Neutron Tolerant Magnetostrictive and Piezoelectric Transducers

Current generation light water reactors (LWRs), sodium cooled fast reactors (SFRs), small modular reactors (SMRs), and next generation nuclear plants (NGNPs) produce harsh environments in and near the reactor core that can severely tax material performance and limit component operational life. To address this issue, several Department of Energy Office of Nuclear Energy (DOE-NE) research programs are evaluating the long duration irradiation performance of fuel and structural materials used in existing and new reactors. In order to maximize the amount of information obtained from Material Testing Reactor (MTR) irradiations, DOE is also funding development of enhanced instrumentation that will be able to obtain in-situ, real-time data on key material characteristics and properties, with unprecedented accuracy and resolution. Such data are required to validate new multi-scale, multi-physics modeling tools under development as part of a science-based, engineering driven approach to reactor development. It is not feasible to obtain high resolution/microscale data with the current state of instrumentation technology. However, ultrasound-based sensors offer the ability to obtain such data if it is demonstrated that these sensors and their associated transducers are resistant to high neutron flux, high gamma radiation, and high temperature. To address this need, the Advanced Test Reactor National Scientific User Facility (ATR-NSUF) is funding an irradiation, led by PSU, at the Massachusetts Institute of Technology Research Reactor to test the survivability of ultrasound transducers. As part of this effort, PSU and collaborators have designed, fabricated, and provided piezoelectric and magnetostrictive transducers that are optimized to perform in harsh, high flux, environments. Four piezoelectric transducers were fabricated with either aluminum nitride, zinc oxide, or bismuth titanate as the active element that were coupled to either Kovar or aluminum waveguides and two magnetostrictive transducers were fabricated with Remendur or Galfenol as the active elements. Pulse-echo ultrasonic measurements of these transducers are made in-situ. This paper will present an overview of the test design including selection criteria for candidate materials and optimization of test assembly parameters, data obtained from both out-of-pile and in-pile testing at elevated temperatures, and an assessment based on initial data of the expected performance of ultrasonic devices in irradiation conditions

Reinhardt1, Brian↗

Transducer Resolution Effect on Pressure Fluctuations Beneath Hypersonic Turbulent Boundary Layers

The size of a pressure transducer is known to affect the accuracy of measurements of wall-pressure fluctuations beneath a turbulent boundary layer because of spatial averaging over the sensing area of the transducer. In this paper, the effect of finite transducer size is investigated by applying spatial averaging or wavenumber filters to a database of hypersonic wall pressure generated from a direct numerical simulation (DNS) that simulates the turbulent portion of the boundary layer over a sharp 7° half-angle cone at nominally Mach 8. Here, a good comparison between the DNS and the experiment in the Sandia Hypersonic Wind Tunnel at Mach 8 is achieved after spatial averaging is applied to the DNS data over an area similar to the sensing area of the transducer. The study shows that a finite sensor size similar to that of the PCB132 transducer can cause significant attenuation in the root-mean-square and power spectral density (PSD) of wall-pressure fluctuations, and the attenuation effect is identical between cone and flat plate configurations at the same friction Reynolds number. The Corcos theory is found to successfully compensate for the attenuated high-frequency components of the wall-pressure PSD.

42 ENGINEERING↗

The effect of a transducer’s spatial averaging on an elastodynamic guided wave’s wavenumber spectrum

Elastodynamic guided waves propagate in an elastic solid which makes it difficult, if not impractical, to place a receiving transducer in the direct path of the propagating wave (as one would for an acoustic wave in a fluid medium). Thus, to account for this, receiving transducers are often placed on the surface of the solid waveguide such that the transducer surface is parallel to the wave propagation direction. This transducer orientation introduces spatial averaging, which causes the received signal to have an altered signal amplitude and mode bias. We investigate both of these effects and present a simple model from which we derive a scaling-ratio expression that describes the effects of spatial averaging. Furthermore, we then test its performance using finite-element simulations that incorporate “real-world” assumptions (e.g., transient waves, piezoelectric effects, etc.). The results from the simulations demonstrate that the scaling-ratio can characterize the effects resulting from spatial averaging. The scaling-ratio expression will be particularly useful when designing experiments involving high frequency (small wavelength) guided waves. Lastly, the proposed scaling-ratio expression could be applied to other sensing methods, like Laser Doppler Vibrometry (LDV) or piezoelectric waveguides with inter-digitated transducers, because of its generality. However, the authors are careful to note that the scaling-ratio expression is not intended as a replacement of multi-physics analysis or good experimental design, and the effects of spatial averaging should be avoided whenever possible.

2DFFT↗

General Testing Setup for Hyperelastic Transducers-DEEC-Tec & Marine Renewable Energy: Preprint

Distributed embedded energy conversion technologies (DEEC-Tec), an emerging domain for ocean wave energy conversion technology, is showing promise for a range of applications. Research is being conducted at the National Renewable Energy Laboratory that leverages this domain to investigate the potential of ocean wave energy converters (WECs) constructed from hyperelastic forms of distributable and embeddable energy transducers. These transducers are available in forms such as disks, rectangles, or hexagons and can be combined in various ways to form energy-producing metamaterials and flexible WECs. DEEC-Tec, therefore, could open doors that enhance ocean wave energy conversion in ways not previously thought possible by allowing for many WEC topologies and morphologies. However, the same diversity and adaptability pose challenges for the development of these DEEC-Tec-oriented hyperelastic transducers. A commercial tensile testing setup was not found that was adaptable enough to accommodate the varied transducers while providing precise force control, range of motion, and noncontact data collection. Because of this lack, a comprehensive test rig was designed in house to be used with a 3D laser scanning device-providing contactless measurements while also allowing for different geometries and various uniaxial loadings. This paper and presentation will discuss these unique challenges and the processes for overcoming them to provide a robust and general testing setup for hyperelastic transducers, of any form, for the DEEC-Tec marine renewable energy domain.

DEEC-Tec↗

Quantum capacities of transducers

Abstract High-performance quantum transducers, which faithfully convert quantum information between disparate physical carriers, are essential in quantum science and technology. Different figures of merit, including efficiency, bandwidth, and added noise, are typically used to characterize the transducers’ ability to transfer quantum information. Here we utilize quantum capacity, the highest achievable qubit communication rate through a channel, to define a single metric that unifies various criteria of a desirable transducer. Using the continuous-time quantum capacities of bosonic pure-loss channels as benchmarks, we investigate the optimal designs of generic quantum transduction schemes implemented by transmitting external signals through a coupled bosonic chain. With physical constraints on the maximal coupling rate $${g}_{\max }$$ g max , the highest continuous-time quantum capacity $${Q}^{\max }\approx 31.4{g}_{\max }$$ Q max ≈ 31.4 g max is achieved by transducers with a maximally flat conversion frequency response, analogous to Butterworth electric filters. We further investigate the effect of thermal noise on the performance of transducers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Irradiation Testing of Ultrasonic Transducers

Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of numerous parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of single, small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. Other efforts include an ultrasonic technique to detect morphology changes (such as crack initiation and growth) and acoustic techniques to evaluate fission gas composition and pressure. These efforts are limited by the lack of existing knowledge of ultrasonic transducer material survivability under irradiation conditions. To address this need, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate promising magnetostrictive and piezoelectric transducer performance in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2 (E> 0.1 MeV). This test will be an instrumented lead test; and real-time transducer performance data will be collected along with temperature and neutron and gamma flux data. By characterizing magnetostrictive and piezoelectric transducer survivability during irradiation, test results will enable the development of novel radiation tolerant ultrasonic sensors for use in Material and Test Reactors (MTRs). The current work bridges the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the performance of ultrasonic transducers

Daw, J.↗

A microchip microcontroller-based transducer controller for non-contact scanning probe microscopy with phase-locked loop, amplitude, and Q control

An inexpensive yet versatile transducer controller for non-contact scanning probe microscopy (SPM) based on a PIC32 microcontroller from Microchip Technology, Inc is described. In addition to feedback control using the amplitude or phase of the signal from the non-contact transducer, the controller includes a phase-locked loop for frequency-shift feedback, as well as fixed-amplitude, quality factor (Q) control, and self-excitation modes. Apart from the input amplifiers, output buffers, and the Q-control circuit, all other functions of the controller are instantiated in software on the microchip, enabling rapid changes in operating parameters if needed. The controller communicates with a host personal computer via a simple serial connection. The controller has been tested with a quartz tuning-fork transducer but can be used with any oscillating non-contact transducer.

47 OTHER INSTRUMENTATION↗

Coupling of electroelastic dynamics and direct contact ultrasonic drying formulation for annular piezoelectric bimorph transducers

A newly developed technique for drying clothes without thermal energy has been developed through the utilization of ultrasonic vibrations from piezoelectric transducers. The novel technique incorporates the actuation of a thin stainless steel disk in contact with wet fabric via annular piezoelectric rings, where water in the liquid form is atomized, transported through microchannels in the disk, and ejected as a mist. In such a system, resonance matching between the actuation portion of the transducer and the portion contacting fabric must be realized, with theoretical results from the developed electromechanical model showing a reduction in energy consumption by 50% when resonance matching is achieved. The electrically coupled distributed parameter model for an annular bimorph piezoelectric transducer is developed for optimization of ultrasonic drying technology. The thickness mode vibrations are shown to dominate the behavior of the system, where the analytically developed model can be optimized to increase the output acceleration of the transducer, thus increasing drying performance. Here, the electromechanical equation developed will be connected to the drying rates of fabrics in contact with said vibrations, where the novelty of the coupled equations and its description of the physics of ultrasonic drying will be discussed.

36 MATERIALS SCIENCE↗

First Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing: Development of Sensor Performance Model of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. Feasibility of the sensor was initially investigated with analytical derivations and with COMSOL RF Module computer simulations of resonant frequency spectral shift due to uniform load. We also investigated the mechanical integrity of the flowmeter’s membrane through analytical modelling and COMSOL Structural Mechanics Module computer simulations. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the material’s yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure. Using results from models, we have developed an initial design for a microwave K-band sensor. A cylindrical resonator prototype was fabricated from brass for the initial tests. The external dimensions of the cavity are matched to the flange of a standard WR-42 waveguide. Microwave field is coupled into the resonant cavity through a subwavelength-size aperture. A test article was developed consisting of a piping Tee with a bulkhead WR-42 microwave waveguide installed in a leak-proof assembly. A microwave waveguide circulator was installed in the setup to suppress the effect of reflections at the cavity entrance by increasing the isolation between the input and the output port. Preliminary spectral characterization of cavity spectral response was performed with a portable PXIe chassis microwave VNA with a custom GUI. Preliminary dry tests of the transducer response were conducted with a set of calibrated weights. Transducer frequency shift was shown to be monotonically increasing with increasing pressure. The next steps will involve investigation of the transducer performance for water flow sensing.

42 ENGINEERING↗

Analysis of Microwave Resonant Cavity Transducer Degradation Mechanisms

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. Because the transducer is intended for immersion in a high temperature corrosive fluid, understanding of material degradation is crucial for estimation of transducer performance lifetime, and development of measurement interpretation algorithms. We conducted a preliminary computational investigation of relevant damage mechanisms of a stainless steel 316 cylindrical resonator in FLiBe salt. The two main damage mechanisms, creep and corrosion, were modeled using multiphysics COMSOL software. Degradation was modeled for a temperature range 500°C to 700°C. Coupling of the damage mechanisms was not considered. These models predict significant inelastic deformation at most temperatures due to creep, and qualitatively predict chromium depletion both along the liquid/solid interface and along the grain boundaries. An algorithmic approach for compensation of these degradation effects during fluid flow measurements will be developed in the future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ultrasonic Transducer Irradiation Test Results

Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. These efforts are limited by the lack of identified ultrasonic transducer materials capable of long term performance under irradiation test conditions. To address this need, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate the performance of promising magnetostrictive and piezoelectric transducers in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2 . A multi-National Laboratory collaboration funded by the Nuclear Energy Enabling Technologies Advanced Sensors and Instrumentation (NEET ASI) program also provided initial support for this effort. This irradiation, which started in February 2014, is an instrumented lead test and real-time transducer performance data are collected along with temperature and neutron and gamma flux data. The irradiation is ongoing and will continue to approximately mid-2015. To date, very encouraging results have been attained as several transducers continue to operate under irradiation.

Daw, Joshua↗

Magneto mitochondrial dysfunction mediated cancer cell death using intracellular magnetic nano-transducers

Mitochondria are crucial regulators of the intrinsic pathway of cancer cell death. The high sensitivity of cancer cells to mitochondrial dysfunction offers opportunities for emerging targets in cancer therapy. Herein, magnetic nano-transducers, which convert external magnetic fields into physical stress, are designed to induce mitochondrial dysfunction to remotely kill cancer cells. Spindle-shaped iron oxide nanoparticles were synthesized to maximize cellular internalization and magnetic transduction. The magneto-mechanical transduction of nano-transducers in mitochondria enhances cancer cell apoptosis by promoting a mitochondrial quality control mechanism, referred to as mitophagy. Furthermore, in the liver cancer animal model, nano-transducers are infused into the local liver tumor via the hepatic artery. After treatment with a magnetic field, in vivo mitophagy-mediated cancer cell death was also confirmed by mitophagy markers, mitochondrial DNA damage assay, and TUNEL staining of tissues. This study is expected to contribute to the development of nanoparticle-mediated mitochondria-targeting cancer therapy and biological tools, such as magneto-genetics.

60 APPLIED LIFE SCIENCES↗