Search NASA⌕ Search

SEARCH · Search NASA

Results for “TRANSITION POINT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Systematic investigations of the influence of the shape of the profile upon the position of the transition point.

The position of the beginning of transition laminar/turbulent as a function of the thickness and the camber of the profile at various Reynolds numbers and lift coefficients was investigated for a series of Joukowsky profiles. The calculation of the boundary layer was carried out according to the Pohlhausen method which may be continued by a simplified stability calculation according to H. Schlichting. A list of tables is given which permits the reading off of the position of the transition point on suction and pressure side for each Joukowsky profile.

Bussmann, K↗

Stability characteristics of a supersonic boundary layer and their relation to the position of the laminar-turbulent transition point

By comparing the calculated results with experimental data, it is demonstrated that the position of the laminar-boundary transition point of a boundary layer can be estimated by using the e-exp-n method. The effect of the Mach number, pressure gradient, and heat transfer on the laminar-turbulent transition is discussed. It is found that under conditions of strong cooling, the effect of the pressure gradient on the position of the transition point is less pronounced than in the absence of heat transfer.

Lysenko, V. I.↗

Investigation of octupole collectivity near the A = 72 shape-transitional point

Enhanced octupole collectivity is expected in the neutron-deficient Ge, Se and Kr isotopes with neutron number N ≈ 40 and has indeed been observed for 70,72 Ge. Shape coexistence and configuration mixing are, however, a notorious challenge for theoretical models trying to reliably predict octupole collectivity in this mass region, which is known to feature rapid shape changes with changing nucleon number and spin of the system. To further investigate the microscopic configurations causing the prolate-oblate-triaxial shape transition at A ≈ 72 and their influence on octupole collectivity, the rare isotopes 72 Se and 74,76 Kr were studied via inelastic proton scattering in inverse kinematics. While significantly enhanced octupole strength of ≈32 Weisskopf units (W.u.) was observed for 72 Se, only strengths of ≈15 W.u. were observed for 74,76 Kr. In combination with existing data, the new data clearly question a simple origin of enhanced octupole strengths around N = 40. Furthermore, the present work establishes two regions of distinct octupole strengths with a sudden strength increase around the A = 72 shape transitional point.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CBr4 vapor growth morphologies near the polymorphic transition point. I - Single crystals. II - Crystals with large-angle grain boundaries

High-resolution microscopy and image processing were used to investigate morphological changes in CBr4 single crystals during growth from the vapor at various levels of supersaturation and at temperatures below the compound's polymorphic phase transition. It was found that, as the temperature increased at fixed supersaturations, the corners of the crystals became rounded as a result of thermal roughening; the rounding temperatures were different for crystallographically different corners. A study of CBr4 crystals with large-angle grain boundaries or twin boundaries (extended macrodefects), conducted at the temperature of polymorphic phase transition showed that the phase transition temperature, T(tr) and crystal surface morphology of these crystals depended on the presence or absence of extended macrodefects. Unlike the case of a perfect single crystal, where the T(tr) was about 46.75 C, the phase transition in crystals with extended macrodefects occurred significantly below 46.75.

Xiao, Rong-Fu↗

Chiral interface at the finite temperature transition point of QCD

The domain wall between coexisting chirally symmetric and broken symmetry regions is studied in a saddle point approximation to the effective three-flavor sigma model. In the chiral limit the surface tension varies in the range ((40 to -50)MeV)(exp 3). The width of the domain wall is estimated to be approximately or equal to 4.5 fm.

Frei, Z.↗

Recent Ground-based Test Results for the Closed Loop Two-Phase Flow Chilldown Test Module for Future Integration with the Flow Boiling and Condensation Experiment onboard International Space Station

Effective cryogenic fluid management is important to the success of future manned and unmanned NASA missions, and the transfer line chilldown process is recognized as a key technological challenge. To address this challenge, the Two-phase Flow and Thermal Management Lab (TFTML) at Case Western Reserve University is collaborating with NASA Glenn Research Center to develop, test and deploy a closed loop two-phase flow chilldown test section onboard the International Space Station to be integrated with the current Flow Boiling and Condensation Experiment (FBCE) module. The final results of this project will create the first chilldown process database under pure and sustained microgravity conditions and will significantly advance the understanding of the chilldown process for cryogenic fluid management. In the present work, the ground-based test results of the closed loop SS-316 chilldown test section in a horizontal configuration at varying inlet mass flow rates (3-40 g/s) and inlet liquid subcooling (5-35 0C) are presented. The working fluid is PF-5060 and the chilldown curves captured the entire quenching curve involving the different boiling regimes and temperature transition points viz., film boiling, Leidenfrost/re-wetting point, transition boiling, critical heat flux (CHF), nucleate boiling, onset of nucleate boiling (ONB) and single-phase liquid flow regions, when the test section is pre-heated to around 250 0C. The major findings of the present study are, (i) the bottom part of the test section sees a lower re-wetting temperature due to the horizontal flow configuration, (ii) the re-wetting temperatures are relatively unaffected by inlet liquid mass flow rates though the increase in mass flow rates reduce the chilldown time, and (iii) the re-wetting temperatures decrease with decrease in inlet liquid subcooling. Further, preliminary flow visualization studies in a transparent pyrex test section will also be presented to understand the intricate flow boiling regime transitions during the chilldown process.

ISS↗

Author Correction: US oil and gas system emissions from nearly one million aerial site measurements

Correction to: Naturehttps://doi.org/10.1038/s41586-024-07117-5 Published online 13 March 2024 In the version of the article initially published, several errors were present and have been corrected in the HTML and PDF versions of the article and Supplementary Information. The main results, conclusions, and our interpretations of the data remain unchanged. See the new Supplementary Information Section S15 for a more detailed description of the errors corrected and the resulting effects on the analysis. Data processing and methods corrections Overflight count correction: We previously used pre-computed source coverage data for some Carbon Mapper campaigns that was computed differently than was required for our analysis. We have re-computed Carbon Mapper source coverage based on flightline polygons and source coordinates. Transition point computation, well sites: The updated version now correctly compares the cumulative emissions distribution of simulated well site emissions with that of aerially detected sources (rather than plumes) when computing the transition point. Transition point computation, midstream: Additionally, the transition point calculation has been corrected to exclude aerially detected midstream emissions below the transition point, which was previously leading to double counting of these emissions. This error was not present for upstream (well site) emissions. Calculation errors Unit error: We corrected a specific unit conversion error affecting well site emissions in the Kairos Fort Worth dataset. Across all datasets, we also correct the conversion factor for converting from standard volume to mass for midstream emissions. Sorting error: We correct code that was applying incorrect sorting when computing correction factors to account for partial detection at well sites. Small typographical corrections were made in Fig. 1b and SI Section S4.1. Data processing and methods corrections Overflight count correction: We previously used pre-computed source coverage data for some Carbon Mapper campaigns that was computed differently than was required for our analysis. We have re-computed Carbon Mapper source coverage based on flightline polygons and source coordinates. Transition point computation, well sites: The updated version now correctly compares the cumulative emissions distribution of simulated well site emissions with that of aerially detected sources (rather than plumes) when computing the transition point. Transition point computation, midstream: Additionally, the transition point calculation has been corrected to exclude aerially detected midstream emissions below the transition point, which was previously leading to double counting of these emissions. This error was not present for upstream (well site) emissions. Calculation errors Unit error: We corrected a specific unit conversion error affecting well site emissions in the Kairos Fort Worth dataset. Across all datasets, we also correct the conversion factor for converting from standard volume to mass for midstream emissions. Sorting error: We correct code that was applying incorrect sorting when computing correction factors to account for partial detection at well sites. Small typographical corrections were made in Fig. 1b and SI Section S4.1. The following practices may help researchers conducting similar analyses avoid making similar errors: 1, Clear, accessible documentation explaining the interpretation of all columns in data input tables and all internal variables within the model, 2, Simple cross-check calculations computed before and after unit conversions.

Sherwin, Evan D↗

Experimental evaluation of heat transfer on a 1030:1 area ratio rocket nozzle

A 1030:1 carbon steel, heat-sink nozzle was tested. The test conditions included a nominal chamber pressure of 2413 kN/sq m and a mixture ratio range of 2.78 to 5.49. The propellants were gaseous oxygen and gaseous hydrogen. Outer wall temperature measurements were used to calculate the inner wall temperature and the heat flux and heat rate to the nozzle at specified axial locations. The experimental heat fluxes were compared to those predicted by the Two-Dimensional Kinetics (TDK) computer model analysis program. When laminar boundary layer flow was assumed in the analysis, the predicted values were within 15% of the experimental values for the area ratios of 20 to 975. However, when turbulent boundary layer conditions were assumed, the predicted values were approximately 120% higher than the experimental values. A study was performed to determine if the conditions within the nozzle could sustain a laminar boundary layer. Using the flow properties predicted by TDK, the momentum-thickness Reynolds number was calculated, and the point of transition to turbulent flow was predicted. The predicted transition point was within 0.5 inches of the nozzle throat. Calculations of the acceleration parameter were then made to determine if the flow conditions could produce relaminarization of the boundary layer. It was determined that if the boundary layer flow was inclined to transition to turbulent, the acceleration conditions within the nozzle would tend to suppress turbulence and keep the flow laminar-like.

Kacynski, Kenneth J.↗

Experimental evaluation of heat transfer on a 1030:1 area ratio rocket nozzle

A 1030:1 carbon steel, heat-sink nozzle was tested. The test conditions included a nominal chamber pressure of 2413 kN/sq m and a mixture ratio range of 2.78 to 5.49. The propellants were gaseous oxygen and gaseous hydrogen. Outer wall temperature measurements were used to calculate the inner wall temperature and the heat flux and heat rate to the nozzle at specified axial locations. The experimental heat fluxes were compared to those predicted by the Two-Dimensional Kinetics (TDK) computer model analysis program. When laminar boundary layer flow was assumed in the analysis, the predicted values were within 15 percent of the experimental values for the area ratios of 20 to 975. However, when turbulent boundary layer conditions were assumed, the predicted values were approximately 120 percent higher than the experimental values. A study was performed to determine if the conditions within the nozzle could sustain a laminar boundary layer. Using the flow properties predicted by TDK, the momentum-thickness Reynolds number was calculated, and the point of transition to turbulent flow was predicted. The predicted transition point was within 0.5 inches of the nozzle throat. Calculations of the acceleration parameter were then made to determine if the flow conditions could produce relaminarization of the boundary layer. It was determined that if the boundary layer flow was inclined to transition to turbulent, the acceleration conditions within the nozzle would tend to suppress turbulence and keep the flow laminar-like.

Kacynski, Kenneth J.↗

Ionic Liquids to Replace Hydrazine

A method for developing safe, easy-to-handle propellants has been developed based upon ionic liquids (ILs) or their eutectic mixtures. An IL is a binary combination of a typically organic cation and anion, which generally produces an ionic salt with a melting point below 100 deg C. Many ILs have melting points near, or even below, room temperature (room temperature ionic liquids, RTILs). More importantly, a number of ILs have a positive enthalpy of formation. This means the thermal energy released during decomposition reactions makes energetic ILs ideal for use as propellants. In this specific work, to date, a baseline set of energetic ILs has been identified, synthesized, and characterized. Many of the ILs in this set have excellent performance potential in their own right. In all, ten ILs were characterized for their enthalpy of formation, density, melting point, glass transition point (if applicable), and decomposition temperature. Enthalpy of formation was measured using a microcalorimeter designed specifically to test milligram amounts of energetic materials. Of the ten ILs characterized, five offer higher Isp performance than hydrazine, ranging between 10 and 113 seconds higher than the state-of-the-art propellant. To achieve this level of performance, the energetic cations 4- amino-l,2,4-triazolium and 3-amino-1,2,4-triazolium were paired with various anions in the nitrate, dicyanamide, chloride, and 3-nitro-l,2,4-triazole families. Protonation, alkylation, and butylation synthesis routes were used for creation of the different salts.

Koelfgen, Syri↗

Maintaining Laminar Flow in the Boundary Layer using a Swept-Back Wing

The positions of boundary-layer transition were ascertained experimentally for a swept-back wing and a wing without sweepback which were alike in all other respects and were compared for the same angle of attack (R(sub e) = 5.6 x 10(exp 5)). The swept-back wing in a definite range of angle of attack resulted in a backward shift of the transition point on the suction side of the wing. The favorable effect of sweepback on the position of the transition point is confirmed, consequently. In addition to decreasing the drag at high Mach numbers, the swept-back wing is acknowledged to have additional advantages. These are: (1) Decrease of the pressure drag. The reduction factor is approximately equal to the cosine of the angle of sweepback. (2) Backward shift of the transition point. There are no known experiments which establish experimentally the advantage anticipated. It appeared justifiable, therefore, to carry out some fundamental experiments which might furnish some idea of the magnitude of the advantage expected. Such an experiment is reported in what follows; the advantage of the sweepback appears clearly.

Brennecke↗

An empirical model for the complex dielectric permittivity of soils as a function of water content

Recent measurements on the dielectric properties of soils have shown that the variation of dielectric constant with moisture content depends on soil types. The observed dielectric constant increases only slowly with moisture content up to a transition point. Beyond the transition it increases rapidly with moisture content. The moisture value at transition region was found to be higher for high clay content soils than for sandy soils. Many mixing formulas reported in the literature were compared with, and were found incompatible with, the measured dielectric variations of soil-water mixtures. A simple empirical model was proposed to describe the dielectric behavior of the soil-water mixtures. This model employs the mixing of either the dielectric constants or the refraction indices of ice, water, rock, and air, and treats the transition moisture value as an adjustable parameter. The calculated mixture dielectric constants from the model were found to be in reasonable agreement with the measured results over the entire moisture range of 0-0.5 cu cm/cu cm. The transition moistures derived from the model range from 0.16 to 0.33 and are strongly correlated with the wilting points of the soils estimated from their textures. This relationship between transition moisture and wilting point provides a means of estimating soil dielectric properties on the basis of texture information.

Wang, J. R.↗

An empirical model for the complex dielectric permittivity of soils as a function of water content

The recent measurements on the dielectric properties of soils shows that the variation of dielectric constant with moisture content depends on soil types. The observed dielectric constant increases only slowly with moisture content up to a transition point. Beyond the transition it increases rapidly with moisture content. The moisture value of transition region was found to be higher for high clay content soils than for sandy soils. Many mixing formulas were compared with, and were found incompatible with, the measured dielectric variations of soil-water mixtures. A simple empirical model was proposed to describe the dielectric behavior of ths soil-water mixtures. The relationship between transition moisture and wilting point provides a means of estimating soil dielectric properties on the basis of texture information.

Wang, J. R.↗

Vortex flow hysteresis

An experimental study was conducted to quantify the hysteresis associated with various vortex flow transition points and to determine the effect of planform geometry. The transition points observed consisted of the appearance (or disappearance) of trailing edge vortex burst and the transition to (or from) flat plate or totally separated flows. Flow visualization with smoke injected into the vortices was used to identify the transitions on a series of semi-span models tested in a low speed tunnel. The planforms tested included simple deltas (55 deg to 80 deg sweep), cranked wings with varying tip panel sweep and dihedral, and a straked wing. High speed movies at 1000 frames per second were made of the vortex flow visualization in order to better understand the dynamics of vortex flow, burst and transition.

Cunningham, A. M., Jr.↗