Search NASA⌕ Search

SEARCH · Search NASA

Results for “TUNGSTEN 169”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Nuclear Data Sheets for A = 169

Experimental data pertaining to all nuclei with mass number A = 169 (Dy, Ho, Er, Tm, Yb, Lu, Hf, Ta, W, Re, Os, Ir, Pt) have been evaluated. Level schemes from both radioactive decay and reaction studies are presented, along with associated tables of experimental data and adopted properties for levels and {gamma} rays. These include data from several recent high-precision measurements of intensities for {gamma} rays emitted in {sup 169}Yb {epsilon} decay; these are of special interest because of their use as calibration standards. Excited-state information is newly available for Re, Os, Ir and Pt, and heavy-ion reaction studies have significantly expanded our knowledge of excited states in Lu through Ta. More extensive work on {epsilon} decay from W is needed and new experimental work will be required to resolve a discrepancy between the J{pi} values deduced for a 180-keV level in {sup 169}Ta based on extensive band structure from (HI,xn{gamma}) work (J{pi} = 1/2-) and TDPAD measurements (J = 5/2). The present evaluation for A = 169, which considers data received by 15 June 2008, supersedes the 1991 evaluation (with a literature cutoff date of March 1990) by V. Shirley, published in Nuclear Data Sheets64, 505 (1991)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-787: Utility of the Two Candidate 192-Ir and 169-Yb HDR Sources for Use with a Novel Direction Modulated Brachytherapy Tandem Applicator for Cervical Cancer Treatment

Purpose: A novel tungsten alloy shielded, MRI-compatible, direction modulated brachytherapy (DMBT) concept tandem applicator, which enables unprecedented intensity modulation, was used to evaluate treatment plan quality improvement over a conventional tandem. The utility of the 192-Ir and 169-Yb HDR sources, for use with the DMBT applicator, was evaluated. Methods: The total diameter of the DMBT tandem applicator is 6.0 mm, which consists of 5.4-mm diameter tungsten alloy and 0.3 mm thick plastic sheath. The tandem has 6 symmetric peripheral 1.3-mm diameter grooves for the source to travel. MCNPX v.2.6 was used to simulate the 192-Ir and 169-Yb sources inside the DMBT applicator. First, TG-43 source parameters were evaluated. Second, 3D dose matrix with 1 mm3 resolution were imported into an in-house-coded inverse optimization treatment planning program to obtain optimal plans for 19 clinical cases. All plans were compared with the standard tandem and ring plans. Prescription dose was 15.0 Gy. All plans were normalized to receive the same HRCTV D90. Results: Generally, the DMBT tandem (and ring) plans were better than the conventional tandem and ring plans for 192-Ir and 169-Yb HDR sources. The mean data of D2cc for bladder, rectum, and sigmoid were 11.65±2.30 Gy, 7.47±3.05 Gy, and 9.84±2.48 Gy for Ir-192 DMBT tandem, respectively. These data for Yb-169 were 11.67±2.26 Gy, 7.44±3.02 Gy, and 9.83±2.38 Gy, respectively. The HR-CTV D98 and V100 were 16.37±1.86 Gy and 97.37 ± 1.92 Gy for Ir-192 DMBT, respectively. The corresponding values for Yb-169 were 16.43±1.86 Gy, and 97.51 ± 1.91 Gy. Plans with the 169-Yb source generally produced more favorable results where V100 increased by 13.65% while D2cc across all OARs reduced by 0.54% compared with the 192-Ir plans. Conclusion: For the DMBT tandem applicator, 169-Yb source seems to produce more directional beams resulting in increased intensity modulation capacity, thus resulting in more conformal plans.

60 APPLIED LIFE SCIENCES↗

SU-F-BRA-05: Utility of the Combined Use of Two Types of HDR Sources with the Direction Modulation Brachytherapy (DMBT) Tandem Applicator for Cervical Cancer Treatment

Purpose: To maximize the dose to HRCTV while minimizing dose to the OARs, the combination of two HDR brachytherapy sources, 192-Ir and 169-Yb, used in combination with the recently-proposed novel direction modulated brachytherapy (DMBT) tandem applicator were examined. Methods: The DMBT tandem, made from nonmagnetic tungsten-alloy rod, with diameter of 5.4mm, has 6 symmetric peripheral holes of 1.3mm diameter. The 0.3mm thick bio-compatible plastic tubing wraps the tandem. MCNPX v.2.6 was used to simulate the mHDR 192-Ir V2 and 4140 HDR 169-Yb sources inside the DMBT applicator. Thought was by combining the higher energy 192-Ir (380keV) and lower energy 169-Yb (92.7keV) sources could create unprecedented level of dose conformality when combined with the high-degree intensity modulation capable DMBT tandem applicator. 3D dose matrices, with 1 mm3 resolution, were imported into an in-house-coded inverse optimization planning system to evaluate plan quality of 19 clinical patient cases. Prescription dose was 15Gy. All plans were normalized to receive the same HRCTV D90. Results: Generally, the use of dual sources produced better plans than using either of the sources alone, with significantly better performance in some patients. The mean D2cc for bladder, rectum, and sigmoid were 11.65±2.30Gy, 7.47±3.05Gy, and 9.84±2.48Gy for 192-Ir-only, respectively. For 169 -Yb-only, they were 11.67±2.26Gy, 7.44±3.02Gy, and 9.83±2.38Gy, respectively. The corresponding data for the dual sources were 11.51±2.24Gy, 7.30±3.00Gy, and 9.68 ±2.39Gy, respectively. The HRCTV D98 and V100 were 16.37±1.86Gy and 97.37±1.92Gy for Ir-192-only, respectively. For 169-Yb-only, they were 16.43±1.86Gy, and 97.51±1.91Gy, respectively. For the dual source, they were 16.42±1.87Gy and 97.47±1.93Gy, respectively. Conclusion: The plan quality improves, in some cases quite significantly, for when dual 192-Ir and 169-Yb sources are used in combination with highly intensity modulation capable DMBT tandem applicator for image guided cervical cancer brachytherapy.

60 APPLIED LIFE SCIENCES↗

Tungsten anode spectral model using interpolating cubic splines: Unfiltered x-ray spectra from 20 kV to 640 kV

Purpose: Monte Carlo methods were used to generate lightly filtered high resolution x-ray spectra spanning from 20 kV to 640 kV. Methods: X-ray spectra were simulated for a conventional tungsten anode. The Monte Carlo N-Particle eXtended radiation transport code (MCNPX 2.6.0) was used to produce 35 spectra over the tube potential range from 20 kV to 640 kV, and cubic spline interpolation procedures were used to create piecewise polynomials characterizing the photon fluence per energy bin as a function of x-ray tube potential. Using these basis spectra and the cubic spline interpolation, 621 spectra were generated at 1 kV intervals from 20 to 640 kV. The tungsten anode spectral model using interpolating cubic splines (TASMICS) produces minimally filtered (0.8 mm Be) x-ray spectra with 1 keV energy resolution. The TASMICS spectra were compared mathematically with other, previously reported spectra. Results: Using pairedt-test analyses, no statistically significant difference (i.e., p > 0.05) was observed between compared spectra over energy bins above 1% of peak bremsstrahlung fluence. For all energy bins, the correlation of determination (R{sup 2}) demonstrated good correlation for all spectral comparisons. The mean overall difference (MOD) and mean absolute difference (MAD) were computed over energy bins (above 1% of peak bremsstrahlung fluence) and over all the kV permutations compared. MOD and MAD comparisons with previously reported spectra were 2.7% and 9.7%, respectively (TASMIP), 0.1% and 12.0%, respectively [R. Birch and M. Marshall, “Computation of bremsstrahlung x-ray spectra and comparison with spectra measured with a Ge(Li) detector,” Phys. Med. Biol. 24, 505–517 (1979)], 0.4% and 8.1%, respectively (Poludniowski), and 0.4% and 8.1%, respectively (AAPM TG 195). The effective energy of TASMICS spectra with 2.5 mm of added Al filtration ranged from 17 keV (at 20 kV) to 138 keV (at 640 kV); with 0.2 mm of added Cu filtration the effective energy was 9 keV at 20 kV and 169 keV at 640 kV. Conclusions: Ranging from 20 kV to 640 kV, 621 x-ray spectra were produced and are available at 1 kV tube potential intervals. The spectra are tabulated at 1 keV intervals. TASMICS spectra were shown to be largely equivalent to published spectral models and are available in spreadsheet format for interested users by emailing the corresponding author (JMB)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of absolute E2 transition strengths in {sup 176}W: Signatures for a rapid shape change

The X(5) symmetry describes nuclei at the critical point of the shape phase transition from axially deformed rotor nuclei to spherical vibrators. {sup 150}Nd, {sup 152}Sm, and {sup 154}Gd were the first nuclei where the predicted characteristics of the X(5) symmetry were observed. Later it was shown that also {sup 176,178,180}Os can be successfully described with the X(5) symmetry.In the close vicinity of shape phase transitions one expects strongly changing nuclear shapes. In the X(5) region around A = 150 this was observed for nuclei with different neutron numbers, whereas in the X(5) region around A = 180 this is to be expected for different proton numbers. The aim of the work presented here is the confirmation of a rapid shape change for nuclei close to {sup 178}Os. Besides the knowledge on the level scheme of the nuclei of interest, especially absolute E2 transition strengths are crucial for the interpretation of nuclear structure. Prolate deformation is expected for {sup 176}W. Thus we performed a recoil distance Doppler shift (RDDS) measurement on {sup 176}W to measure E2 transition strengths from level lifetimes. The experiment was performed at the Cologne FN TANDEM accelerator with the Cologne coincidence plunger with the reaction {sup 169}Dy({sup 16}O,4n){sup 176}W and a beam energy of 80 MeV. We will present our experimental results and relate them to data on the neighboring nuclei {sup 178}Os and {sup 182}Pt. The results will be discussed in the framework of nuclear shape transitions in this mass region and compared to calculations with both the Interacting Boson Model (IBM) and the GCM.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗