Search NASA⌕ Search

SEARCH · Search NASA

Results for “TURBINES - BLADES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Cold-air performance of compressor-drive turbine of department of energy upgraded automobile gas turbine engine. 3: Performance of redesigned turbine

The aerodynamic performance of a redesigned compressor drive turbine of the gas turbine engine is determined in air at nominal inlet conditions of 325 K and 0.8 bar absolute. The turbine is designed with a lower flow factor, higher rotor reaction and a redesigned inlet volute compared to the first turbine. Comparisons between this turbine and the originally designed turbine show about 2.3 percentage points improvement in efficiency at the same rotor tip clearance. Two versions of the same rotor are tested: (1) an as cast rotor, and (2) the same rotor with reduced surface roughness. The effect of reducing surface roughness is about one half percentage point improvement in efficiency. Tests made to determine the effect of Reynolds number on the turbine performance show no effect for the range from 100,000 to 500,000.

Roelke, R. J.↗

Cold-air performance of free power turbine designed for 112-kilowatt automotive gas-turbine engine. 2: Effects of variable stator-vane-chord setting angle on turbine performance

The cold-air performance of an axial-flow power turbine with a variable stator designed for a 112-kW automotive gas-turbine engine was determined at speeds from 30 to 110 percent of design and at pressure ratios from 1.11 to 2.67. Performance is presented in terms of equivalent mass flow, torque, power, and efficiency for stator-vane-chord setting angles of 26 degs, 30 degs, 35 degs (design), 40 degs, 45 degs, and 50 degs. Turbine braking performance at a nominal stator setting angle of 107 degs is also presented. Turbine efficiency increased with increasing stator setting angle. A 10-point efficiency increase was obtained by opening the stator from the design setting angle of 35 degs to a setting angle of 45 degs.

Mclallin, K. L.↗

Preliminary Evaluation of Turbine Performance with Variable-Area Turbine Nozzles in a Turbojet Engine

The performance of a two-stage turbine with variable-area first-stage turbine nozzles was determined in the NACA Lewis altitude wind tunnel over a range of simulated altitudes from 15,000 to 44,000 feet and engine speeds from 50 to 100 percent of rated speed. The variable-area turbine nozzles used in this investigation were primarily a test device for compressor research purposes and were not necessarily of optimum aerodynamic design. The results of this investigation are indicative of effects of turbine-nozzle-area variation on turbine performance within the operating range allowed by the engine. The variable-area turbine nozzles were found to be mechanically reliable and to have negligible leakage losses. Increasing the turbine-nozzle-throat area from 1.15 to 1.67 square feet increased the corrected turbine gas flow or effective turbine nozzle area about 10 percent. At a given corrected turbine speed and turbine pressure ratio, changing the turbine nozzle area from 1.30 to 1. 67 square feet lowered the turbine efficiency 3 or 4 percent. The effect of increasing the turbine nozzle area from 1.15 to 1.67 square feet (decreasing the turning angle about 7 1/2 degrees) would be to lower the turbine efficiency about 5 or 6 percent.

Campbell, Carl E.↗

Effect of Air Cooling of Turbine Disk on Power and Efficiency of Turbine from Turbo Engineering Corporation TT13-18 Turbosupercharger.

An investigation was conducted to determine the effect of turbine-disk cooling with air on the efficiency and the power output of the radial-flow turbine from the Turbo Engineering Corporation TT13-18 turbosupercharger. The turbine was operated at a constant range of ratios of turbine-inlet total pressure to turbine-outlet static pressure of 1,5 and 2.0, turbine-inlet total pressure of 30 inches mercury absolute, turbine-inlet total temperature of 12000 to 20000 R, and rotor speeds of 6000 to 22,000 rpm, Over the normal operating range of the turbine, varying the corrected cooling-air weight flow from approximately 0,30 to 0.75 pound per second produced no measurable effect on the corrected turbine shaft horsepower or the turbine shaft adiabatic efficiency. Varying the turbine-inlet total temperature from 12000 to 20000 R caused no measurable change in the corrected cooling-air weight flow. Calculations indicated that the cooling-air pumping power in the disk passages was small and was within the limits of the accuracy of the power measurements. For high turbine power output, the power loss to the compressor for compressing the cooling air was approximately 3 percent of the total turbine shaft horsepower.

Berkey, William E.↗

Performance of 19XB-2A Gas Turbine: Effect of Pressure Ratio and Inlet Pressure on Turbine Performance for an Inlet Temperature of 800 degree R - 1

An investigation of the 19XB-2A gas turbine is being conducted at the Cleveland laboratory to determine the effect on turbine performance of various inlet pressures, inlet temperatures, pressure ratios, and wheel speeds. The engine of which this turbine is a component is designed to operate at an air flow of 30 pounds per second at a compressor rotor speed of 17,000 rpm at sea-level conditions. At these conditions the total-pressure ratio is 2.08 across the turbine and the turbine inlet total temperature is 2000 degrees R. Runs have been made with turbine inlet total pressures of 20, 30, 40, and 45 inches of mercury absolute for a constant total pressure ratio across the turbine of 2.40, the maximum value that could be obtained. Additional runs have been made with total pressure ratios of 1.50 and 2.00 at an inlet total pressure of 45 inches of mercury absolute. All runs were made with an inlet total temperature of 800 degrees R over a range of corrected turbine wheel speeds from 40 to 150 percent of the corrected speed at the design point. The turbine efficiencies at these conditions are presented.

Kohl, Robert C.↗

Hydrogen turbines for space power systems: A simplified axial flow gas turbine model

Hydrogen cooled, turbine powered space weapon systems require a relatively simple, but reasonably accurate hydrogen gas expansion turbine model. Such a simplified turbine model would require little computational time and allow incorporation into system level computer programs while providing reasonably accurate volume/mass estimates. This model would then allow optimization studies to be performed on multiparameter space power systems and provide improved turbine mass and size estimates for the various operating conditions (when compared to empirical and power law approaches). An axial flow gas expansion turbine model was developed for these reasons and is in use as a comparative bench mark in space power system studies at Sandia. The turbine model is based on fluid dynamic, thermodynamic, and material strength considerations, but is considered simplified because it does not account for design details such as boundary layer effects, shock waves, turbulence, stress concentrations, and seal leakage. Although the basic principles presented here apply to any gas or vapor axial flow turbine, hydrogen turbines are discussed because of their immense importance on space burst power platforms.

Hudson, Steven L.↗

Gas Turbine Engine Having Fan Rotor Driven by Turbine Exhaust and with a Bypass

A gas turbine engine has a core engine incorporating a core engine turbine. A fan rotor is driven by a fan rotor turbine. The fan rotor turbine is in the path of gases downstream from the core engine turbine. A bypass door is moveable from a closed position at which the gases from the core engine turbine pass over the fan rotor turbine, and moveable to a bypass position at which the gases are directed away from the fan rotor turbine. An aircraft is also disclosed.

Suciu, Gabriel L.↗

Aircraft engine with inter-turbine engine frame supported counter rotating low pressure turbine rotors

An aircraft gas turbine engine assembly includes an inter-turbine frame axially located between high and low pressure turbines. Low pressure turbine has counter rotating low pressure inner and outer rotors with low pressure inner and outer shafts which are at least in part rotatably disposed co-axially within a high pressure rotor. Inter-turbine frame includes radially spaced apart radially outer first and inner second structural rings disposed co-axially about a centerline and connected by a plurality of circumferentially spaced apart struts. Forward and aft sump members having forward and aft central bores are fixedly joined to axially spaced apart forward and aft portions of the inter-turbine frame. Low pressure inner and outer rotors are rotatably supported by a second turbine frame bearing mounted in aft central bore of aft sump member. A mount for connecting the engine to an aircraft is located on first structural ring.

Seda, Jorge F.↗

Drive turbine system for 20-inch turbofan simulators. 2: Core turbine design

Drive-turbines for a given set of 20-inch turbo-fan simulators are described. The simulators had both single-stage and two-stage fans that had design pressure ratios as low as 1.25 and as high as 3.0. The desired objective of the study was to be able to drive all of the single-stage fans with one core turbine and to drive all of the two-stage fans with this same core turbine in combination with a duct turbine. The core turbine is described. Included are the design operating conditions, design velocity diagram and a power-speed envelope determined by an off-design performance procedure. Also discussed is the adaption and scaling of an existing turbine design to this particular application.

Whitney, W. J.↗

Component Performance Investigation of J71 Experimental Turbine VII: Effect of First-stator Adjustment; Over-all Performance of J71-97 Turbine with 87-percent-design Stator Area

The performance results, as well as a compressor-turbine match point study based on a particular mode of engine operation, are compared with those previously obtained with the same turbine having first-stator areas 70, 95.6, and 132 percent of design. Maximum efficiencies for all turbine configurations were high, on the order of 87 to 89 percent. The efficiencies obtained at the match points for the 87-, 95.6-, and 132-percent turbines were slightly lower. No match point for the 70-percent turbine was obtained because, with first-stator areas less than 75.5 percent of design, the turbine would develop insufficient work to drive the compressor at the match point.

Schum, Harold J↗

Capability Extension to the Turbine Off-Design Computer Program AXOD With Applications to the Highly Loaded Fan-Drive Turbines

The axial flow turbine off-design computer program AXOD has been upgraded to include the outlet guide vane (OGV) into its acceptable turbine configurations. The mathematical bases and the techniques used for the code implementation are described and discussed in lengths in this paper. This extended capability is verified and validated with two cases of highly loaded fan-drive turbines, designed and tested in the V/STOL Program of NASA. The first case is a 4 1/2-stage turbine with an average stage loading factor of 4.66, designed by Pratt & Whitney Aircraft. The second case is a 3 1/2-stage turbine with an average loading factor of 4.0, designed in-house by the NASA Lewis Research Center (now the NASA Glenn Research Center). Both cases were experimentally tested in the turbine facility located at the Glenn Research Center. The processes conducted in these studies are described in detail in this paper, and the results in comparison with the experimental data are presented and discussed. The comparisons between the AXOD results and the experimental data are in excellent agreement.

Chen, Shu-cheng S.↗

Investigation of turbines suitable for use in a turbojet engine with high compressor pressure ratio and low compressor-tip speed I : turbine-design requirements for several engine operating conditions

In order to insure satisfactory turbine performance under five turbojet-engine operating conditions, turbine design requirements were determined for the following operating conditions: take-off, maximum thrust at altitude, altitude cruising at rated rotative speed, altitude cruising with maximum-thrust exhaust nozzle area, and engine acceleration at 80 percent equivalent design rotative speed. If cruising is to be at rated engine speed, both cruising and take-off should be considered in turbine design. Design requirements for the other conditions are nearly identical. Without compressor-exit bleed, a turbine cannot accelerate this compressor at 80 percent of rated speed; with 28.6-percent bleed, the design requirements are within those for take-off.

TURBINES--AXIAL FLOW↗

Numerical Investigation of Combustor-Turbine Interactions with a Two-Stage High-Pressure Turbine Including Cooling Airflows

Combustor–turbine interactions (CTIs) are investigated by performing three-dimensional unsteady simulations using a realistic combustor and high-pressure turbine (HPT) configurations from the Energy Efficient Engine (E3) program. To understand CTIs, we compare the numerically predicted flow fields from single-component simulations (Step 1: the combustor + the first-stage stator of turbine; Step 2: the two-stage HPT imposing the time-averaged flow solution from Step 1 as the inflow boundary condition) and a fully coupled combustor–turbine simulation (Step 3) at the sea-level takeoff (SLTO) condition. In addition to three previous simulations where the cooling airflows inside the HPT had been neglected for all Step 1, Step 2, and Step 3, two new simulations of Step 2 and Step 3 take into account the cooling airflows using the source team approach. In this approach, to mimic the cooling airflows, we impose the source term at a specific area of a cooling airflow hole at the solid surfaces without making a mesh of each hole. The objective of this study is twofold. One is to investigate the effect of the presence of the cooling airflows on the aerodynamics of the combustor and HPT as well as the HPT performance. The second is to perform a detailed comparison among the calculated flowfields by two different numerical schemes, the central-difference with the standard Jameson–Schmidt–Turkel (CD-JST) scheme and the AUSM scheme. There is a noticeable difference in the hot-streak distributions at the first-stage stator. In addition, depending on the choice of the numerical scheme and the presence of the cooling airflows, an occurrence of shock waves appearing at the first-stage stator is greatly influenced. Thus, this has a noticeable impact on the HPT performance. It is shown that the estimated turbine efficiencies from Step 3 are about 7 % less than the ones from Step 2.

Combustor-turbine interaction↗

Numerical Investigation of Combustor-Turbine Interactions with Cooling Air Flows Included in High-Pressure Turbine

In this paper, we would like to include the cooling airflows inside the turbine and perform the fully-coupled combustor–turbine simulation at a realistic sea-level takeoff (SLTO) condition. The new results are compared with the previous study,in which we performed the fully-coupled combustor–turbine simulation without the cooling airflows and the purge flows inside the HPT. This paper also serves to provide a better understanding about the effect of the unsteadiness in the turbine inflow condition on the turbine performance in the presence of the cooling airflows.

LES↗

Experimental investigation of a 4 and 1/2 stage turbine with very high stage loading factor. 2: Turbine performance

The experimental test program results of a 4 1/2-stage turbine with a very high stage loading factor are presented. A four-stage turbine was tested with and without outlet turning vanes. The 4 1/2-stage turbine achieved a design point total-to-total efficiency of 0.853. The outlet turning vane design point performance was 0.4 percent of the overall 4 1/2-stage turbine efficiency. Tests were conducted at various levels of Reynolds number and indicated decreases in turbine efficiency and equivalent weight flow with decreasing Reynolds number.

Walker, N. D.↗

Extended parametric representation of compressor fans and turbines. Volume 2: Part user's manual (parametric turbine)

A turbine modeling technique has been developed which will enable the user to obtain consistent and rapid off-design performance from design point input. This technique is applicable to both axial and radial flow turbine with flow sizes ranging from about one pound per second to several hundred pounds per second. The axial flow turbines may or may not include variable geometry in the first stage nozzle. A user-specified option will also permit the calculation of design point cooling flow levels and corresponding changes in efficiency for the axial flow turbines. The modeling technique has been incorporated into a time-sharing program in order to facilitate its use. Because this report contains a description of the input output data, values of typical inputs, and example cases, it is suitable as a user's manual. This report is the second of a three volume set. The titles of the three volumes are as follows: (1) Volume 1 CMGEN USER's Manual (Parametric Compressor Generator); (2) Volume 2 PART USER's Manual (Parametric Turbine); (3) Volume 3 MODFAN USER's Manual (Parametric Modulation Flow Fan).

Coverse, G. L.↗