At least 19 records

Predicting critical heat flux using localized sensing at invisible vapor-liquid interfaces

Predicting critical heat flux (CHF) in two-phase electronics cooling systems remains a significant challenge due to the sudden onset of boiling crisis and the difficulty in directly visualizing vapor-liquid interfaces. Existing sensing methods rely on lagging temperature measurements, optically accessible systems, or spatially averaged signals that cannot pinpoint CHF initiation at localized high-heat-flux regions. Here, we report a planar capacitive sensing approach that enables real-time, localized detection of vapor-liquid interface dynamics for CHF prediction in boiling heat transfer. The capacitive sensor exploits the dielectric constant difference between liquid and vapor phases to capture bubble nucleation, growth, and departure dynamics with a temporal resolution down to 2 ms. The capacitive sensing reveals distinct signals across boiling regimes: from high-frequency fluctuations during strong nucleate boiling to low-frequency fluctuations with increased amplitudes when approaching CHF. The multi-sensor array experiments demonstrate real-time localized sensing, where each sensor responds exclusively to boiling in its immediate vicinity without crosstalk from neighboring regions. This non-intrusive sensing approach provides predictive rather than lagging sensing signals of CHF occurrence, offering predictive diagnosis of two-phase liquid cooling for the thermal management of high-power-density electronics.

CHF↗

Two-Phase Cooling for High Packaging Density Planar Inverter: Cooperative Research and Development Final Report, CRADA Number CRD-15-00592

The project objective was to utilize two-phase heat transfer to enable compact and power-dense inverters. The high heat transfer capacity and near isothermal characteristics of two-phase cooling can enable higher power densities, reducing the size and cost of the power electronics system. This project focused on developing efficient, passive (no pump or compressor) two-phase cooling strategies that consist of an air-cooled condenser and evaporator. This report describes the modeling work conducted to design the evaporator and air-cooled condenser for a prototype inverter development work underway in the John Deere. Prototypes of the final evaporator and condenser designs were then fabricated via 3D printing for testing. Experiments on the evaporator confirmed that this component can meet the heat load and junction temperatures requirements for Si IGBT (insulated-gate bipolar transistor) inverter. Experiments with the air-cooled condenser were not possible due to leaks through the condenser walls.

33 ADVANCED PROPULSION SYSTEMS↗

Alchemy: A Model-Based Approach for 2D to 3D Autonomous Nuclear System Design

Engineering design of nuclear power plant (NPP) piping and equipment systems frequently bypasses crucial 2D system planning, instead moving straight to 3D modeling. This often leads to designs that exceed building envelope constraints, forcing expensive and time-consuming redesigns. When 2D modeling is employed, it typically involves labor-intensive manual workflows that convert 2D drawings into 3D models, resulting in inefficiencies and errors across design iterations. These workflows further suffer from poor software interoperability and dependence on proprietary software ecosystems, thereby contributing to schedule delays and cost overruns. This paper presents Alchemy, an autonomous framework that transforms 2D system definitions into Industry Foundation Classes (IFC)-compliant 3D building information models (BIMs) for expediting nuclear facility design at the conceptual preliminary phase. Using a model-based approach, the framework treats the 2D system diagram as the central reference model employed to automatically generate all subsequent outputs, ensuring consistency between the system definition and the resulting physical design. A web-based interface enables engineers to define hierarchical system topologies including associated equipment, geometric properties, and connectivity requirements. A two-phase equipment layout optimization algorithm automatically computes collision-free spatial configurations within predefined building envelopes. An artificial intelligence (AI)-assisted pipe routing module then generates orthogonal, collision-free routing paths, allowing the user to select either an A* search-based method or an Ant Colony Optimization (ACO)-based method. All outputs are authored natively in IFC format, relying on open-source technologies and standardized formats in order to ensure extensibility and eliminate proprietary software dependencies. The proposed framework is validated on two representative pressurized-water reactor (PWR)-based case studies, for which it autonomously generates IFC-compliant 3D models in minutes, drastically reducing workflows that typically require hours of manual effort. The generated model demonstrates topologically correct equipment placement, physically plausible spatial relationships, and collision-free pipe routing consistent with known PWR loop configurations. This work represents a foundational step toward digital engineering for nuclear facility preliminary design, with future ongoing development targeting design code compliance and expanded system complexity.

97 - MATHEMATICS AND COMPUTING↗

Performance of a dynamic single bubbler in single and two-phase immiscible liquids

Ensuring nonproliferation and safeguards of special nuclear materials (SNM) is a critical aspect of advancing the nuclear fuel cycle. Traditional bubbler systems used to estimate liquid levels and densities in nuclear recycling processes have limitations, particularly in harsh environments where dip-tube corrosion and buildup necessitate frequent maintenance and recalibration. This study explores the Dynamic Single Bubbler (DSB) method, which utilizes a single dip-tube attached to a linear actuator to estimate liquid properties dynamically. This approach is extended to estimate liquid-liquid interfaces in immiscible liquids and employs a linear regression method to reduce uncertainties and improve accuracy. The DSB method achieved density estimate uncertainties of less than 0.5% and surface level estimate uncertainties typically under 0.5%, across various fluids including water, acetone, methanol, mineral oil, glycerol, and aqueous salt solutions. Results indicate that the DSB method provides accurate and robust estimates of liquid density and surface levels with minimal maintenance and without the need for calibration. Additionally, the method's applicability to immiscible liquids and various dip-tube geometries was demonstrated, showing promise for widespread use in nuclear and other industrial applications.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

A Multiscale Approach to Simulate Non‐Isothermal Multiphase Flow in Deformable Porous Materials

Coupled thermal, hydraulic, and mechanical processes in porous materials play important roles in several energy and environmental technologies. The Darcy-Brinkman-Biot (DBB) framework has proven effective in modeling multiphase fluid flow in deformable porous solids across both pore and Darcy scales, including in systems where fractures coexist with a porous matrix. In this study, we extend the DBB framework, originally designed for isothermal conditions, to address non-isothermal problems by incorporating an energy conservation equation. The resulting solver, hybridBiotThermalInterFoam, enables simulations of coupled multiphase fluid flow, heat transfer, and solid deformation in hybrid-scale systems containing both solid-free regions and ductile porous domains. The new solver is validated through comparisons with analytical solutions and, also, against established heat transfer solvers chtMultiRegionFoam and compressibleInterFoam. Further, a series of 2D and 3D case studies, including two-phase heat transfer in solid-free, static, or deformable porous media, highlights the solver's capacity to simulate complex flow dynamics and heat transport in systems involving high mobility ratios, viscous fingering, and fracture propagation. Our results establish the feasibility of incorporating thermal effects in simulations of a wide variety of energy geotechnics and environmental applications, including enhanced hydrocarbon recovery, soil remediation, and enhanced geothermal energy systems.

04 OIL SHALES AND TAR SANDS↗

Maintenance strategy, structural design, and site layout of the ST-E1 fusion power plant

An effective fusion reactor maintenance scheme enables safe operations and short downtimes. This in turn leads to high availability, which is critical to the commercial viability of a power-producing plant. In tokamak-based fusion power plants, the chosen maintenance approach has a significant impact on the spatial design of the tokamak, as well as the surrounding infrastructure, and therefore needs to be considered from the outset. Tokamak Energy has developed a pre-concept design of a fusion power plant, ST-E1. This work describes the major drivers and constraints that have been considered, presents the tokamak architecture and chosen maintenance regime, and discusses how this enables the plant’s two-phased approach to demonstrating commercial operations. It also shows the implications for the design of other systems areas, in particular the machine structural arrangement and bioshield and hot cell layout. The reactor core segmentation and removal scheme replaces entire toroidal segments radially through a large vacuum port, along a single axis only. The result is a change-tolerant machine and plant layout that can accommodate the evolving designs of the tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Boundary Element Model for Assessing Large‐Scale Pressurization in Faulted Geological Storage Systems

Assessing large-scale pressurization at the regional scale—a possible outcome of large subsurface storage applications such as wastewater injection and geological carbon sequestration—presents significant computational challenges. These challenges are particularly pronounced when accounting for complex geologic structures with multiple reservoir and caprock layers, fault zones, and wells. This study introduces a computationally efficient model that integrates single-phase semi-analytical solutions with a boundary element (BE) approach. The model simulates pressure propagation in multilayered 3D systems, including vertical faults, caprock, basement, and confining units. We apply this new model to a representative scenario involving CO 2 injection near a partially sealing fault with verification against an independent two-phase flow model. Results demonstrate that our model accurately captures far-field pressure responses and that, outside the CO 2 plume zone, pressure predictions from single-phase and two-phase models are nearly identical. This supports the use of single-phase models like ours for efficient estimation of far-field pressure changes. Additionally, we demonstrate its effectiveness at a large scale, incorporating multiple wells and faults. With its ability to represent multiple wells, fault zones, and geological heterogeneity, our model is well suited for assessments of basin-scale pressurization. Its computational efficiency also makes it a promising tool for integration with optimization frameworks aimed at designing and managing injection strategies in faulted storage systems.

Cihan, A. [Lawrence Berkeley National Laboratory (↗

A Finite Element Method for Compressible and Turbulent Multiphase Flow Instabilities with Heat Transfer

We present a new finite element framework for modeling compressible, turbulent multiphase flows with heat transfer. For two-fluid systems with a free surface, the Volume of Fluid (VOF) method is implemented without the need for interface reconstruction, while turbulence is resolved using a dynamic Vreman large eddy simulation (LES) model. Unlike most two-phase VOF studies, which neglect heat transfer, the present approach incorporates energy transport equations within the VOF formulation to account for heat exchange, an effect particularly important in turbulent flows. Conjugate heat transfer is often challenging in finite volume methods, which require explicit specification of heat fluxes at the solid–fluid interface, limiting accuracy and predictive capability. By contrast, the finite element formulation does not require heat flux inputs, allowing more accurate and robust simulation of heat transfer between solids and fluids. The method is demonstrated through three representative cases. First, a two-fluid instability with a single-mode perturbation is simulated and validated against analytical growth rates. Second, conjugate heat transfer is examined in a high-temperature flow over a cold metal cylinder, with validation performed both quantitatively—via pressure coefficient comparisons with experimental data—and qualitatively using vector field topology. Finally, compressible spray injection and breakup are modeled, demonstrating the ability of the framework to capture interfacial dynamics and atomization under turbulent, high-speed conditions. In the compressible spray injection and breakup case, the results indicate that the finite element formulation achieved higher predictive accuracy and robustness than the finite-volume method. With the same mesh resolution, the FEM reduced the root mean square error (RMSE) and mean absolute percentage error (MAPE) from 6.96 mm and 26.0% (for the FVM) to 4.85 mm and 12.7%, respectively, demonstrating improved accuracy and robustness in capturing interfacial dynamics and heat transfer. The study also introduced vector field topology to visualize and interpret coherent flow structures and instabilities, offering insights beyond conventional scalar-field analyses.

97 MATHEMATICS AND COMPUTING↗

Characterization of Inlet Guide Vane Performance for Discharge Compressor Operation near the Dome of an sCO 2 Pumped Heat Energy Storage

Southwest Research Institute® (SwRI®) developed and tested a Variable Inlet Guide Vane (IGV herein) assembly on an integrally-geared sCO 2 compressor (IGC) to demonstrate compressor operation at both the compressor design point and near the dome and to define the operating limits of the compressor by monitoring for two-phase flow, flow turbulence from the IGVs, and compressor choke and surge as the CO 2 inlet temperature is varied. Performance testing was conducted on an existing integrally-geared, two-stage main compressor designed for near-critical-point operation with CO 2 . This testing campaign validated the IGV design and operation, as well as improved the understanding and confidence in operating compressors and predicting performance characteristics near the critical point where fluid properties change rapidly with temperature. In addition to improving the robust operating limits of an sCO 2 compressor, the development of an IGV for the IGC system improved off-design compressor efficiency by 12%.

25 ENERGY STORAGE↗

Carbon Tetrachloride Degradation Results for 200-ZP-1 Operable Unit

Carbon tetrachloride (CT) contamination in the 200-ZP-1 Operable Unit (OU) at the Hanford Site originated from large-volume discharges to the subsurface during plutonium production operations between 1955 and 1973. Contamination migrated through more than 70 meters of unsaturated sediment to reach the underlying unconfined aquifer, where it persists as a large and complex groundwater plume. The 200-ZP-1 OU Record of Decision (ROD) requires that groundwater CT concentrations be reduced to 3.4 µg/L within 125 years. Current groundwater modeling projections estimate that the existing pump-and-treat, even when combined with monitored natural attenuation (specifically hydrolysis), will not achieve this target within the designated timeframe. A fundamental contributor to this shortfall is the extremely slow rate of CT hydrolysis under Hanford aquifer conditions, which has been estimated to have a half-life of 630 years. If faster-acting biotic and abiotic degradation processes are operating within the aquifer, their contribution to CT mass reduction could have a meaningful impact. However, site-specific measurements of these processes and their rates have not previously been performed. This report documents the results of a two-phase laboratory investigation designed to characterize and quantify the capacity of site-specific 200-ZP-1 OU sediments and groundwater to support natural attenuation of CT through biotic and abiotic pathways. In this context, degradation capacity is defined as the intrinsic potential of the subsurface matrix to transform CT under optimized, controlled conditions. System capacity is evaluated in two ways: (1) as rate-limited capacity, which establishes the maximum kinetic velocity of CT transformation and is measured using half-lives and first order rate constants; and (2) as mass limited capacity, which defines the total contaminant mass the batch experimental system can degrade before reactants are exhausted, representing the maximum amount of contaminant the microbial community and reactive mineral phases can transform under the experimental conditions.

abiotic degradation↗

Using X-ray radiography to study oxygen flow in a proton exchange membrane electrolyzer operating under balanced pressure conditions

Of the various water electrolyzer technologies, the proton exchange membrane electrolyzer (PEMWE) is one of the best solutions for producing clean hydrogen without releasing CO 2 . In order to allow for widespread use of clean hydrogen, it is necessary to decrease its cost, which is intrinsically related to system operation. Current PEMWE plants operate in differential mode, directly pressurizing hydrogen and benefiting from thermodynamic compression, which increases overall system efficiency. However, high differential pressure above 30 bar can cause membrane stress, resulting in membrane creeping and failure. Pressurizing the water and operating at balanced pressure allows hydrogen to be produced at higher pressures while preserving the integrity of the membrane and porous layers. Nevertheless, the impact of pressurizing water on PEMWE performance must be better understood to maximize performance under balanced pressure conditions. Here, this study examined the impact of water pressure on two-phase flow. A high-pressure electrolyzer setup was developed to perform operando X-ray radiography and examine oxygen transport with high temporal resolution. The imaging segmentation process, developed to capture bubble properties in the channel, was applied to a specific experiment. The results clearly showed that as pressure increased up to 30 bars, the initial bubbly flow transitioned to slug flow, which led to channel saturation with oxygen. This work demonstrates that two-phase flow in an electrolyzer can be studied using X-ray radiography, which has the advantages of fast measurements and the ability to probe dense materials, such as those required for pressurized electrolyzers.

Balanced high pressure operation↗

Non-dimensional performance and safety parameters for heat pipes

The use of heat pipes in safety-critical systems such as nuclear microreactors dictates the development of generalized, practical, scalable performance and safety parameters. Traditional dimensional metrics, while informative, lack the universality required for comparative analysis across varying designs and operating regimes. Here, this work introduces a comprehensive set of non-dimensional parameters to characterize heat pipe performance and safety, including capillary performance, effective thermal conductivity, response time, exergetic efficiency, allowable temperature gradients, allowable rate of temperature change, priming coefficients, and factor of safety. A reference heat pipe design representative of microreactor applications was analyzed via the developed parameters using both traditional analytical models and Sockeye simulations under transient and steady-state conditions. Sodium, potassium, and water were evaluated as working fluids to demonstrate the applicability of the framework across a broad temperature range. The proposed non-dimensional parameters effectively captured key thermal-hydraulic behaviors and safety concerns, as was demonstrated via Sockeye simulations. This framework supports the development of design optimization strategies, operational protocols, and safety assurance practices for advanced reactor systems and other high-reliability applications.

42 - ENGINEERING↗

Prototype Modeling for a Light-Trapping Planar-Cavity Enclosed Particle Solar Receiver

Concentrating solar thermal (CST) systems present a promising avenue for affordable and reliable energy production. Solar receivers are key components that determine the efficiency and longevity of these systems. Particle-based solar receivers have emerged as a compelling alternative to traditional technologies, offering several advantages that address limitations in current CST systems. This is especially true as next-generation CST technologies target applications including electricity generation, thermochemical processes, and industrial process heat, many of which necessitate higher operating temperatures than current commercial molten salt systems. Molten-salt thermal energy storage (TES) systems, commonly used in CSP, face challenges related to freezing and corrosion. Particle-based TES systems, in contrast, do not experience these issues, as particles are stable at high temperatures, exceeding 1000 degrees Celsius. This capability allows for a wider range of applications, including those requiring higher temperatures for industrial processes and efficient electricity generation. A novel innovation in particle-based solar receiver technology is the light-trapping planar cavity receiver (LTPCR) configuration developed by NREL. The LTPCR design consists of small cavity-like structures using opaque planar surfaces, enabling efficient capture and absorption of solar energy. A high incident flux concentration at the cavity aperture is absorbed on the receiver walls, and subsequently transferred to particles on the inside of cavities. The particles flow through the system, forming a fluidized bed inside of the receiver panels, effectively capturing the absorbed solar heat. Air is used as a fluidizing medium in this process to enhance particle heat transfer and mixing. The effectiveness of this design lies in its ability to manage solar flux conditions and ensure high solar-to-thermal receiver efficiency. A 100-kW prototype is currently being tested at the King Saud University in Saudi Arabia to assess the receiver performance. A range of modeling analyses for the optical, thermal, and mechanical effects were conducted to assess the performance of the receiver under on-sun conditions. The solar flux resulting from the KSU heliostat field was modeled using NREL SolTrace software and produced up to 600 kW/m2 at the receiver aperture. The solar flux absorbed on the receiver walls was then used within a computational fluid dynamics (CFD) model to predict wall temperature distributions along with radiation and convection loss. A two-phase CFD model was developed for the fluidized bed of silica sand inside the receiver panels to predict local wall-to-particle heat transfer coefficients, particle temperature distributions, and outlet temperature of the particles. We have also conducted analyses to understand the thermomechanical behavior of these innovative enclosed light-trapping solar receivers optimized for particle heating. We used finite element analysis (FEA) to predict the receiver's performance using temperature distributions obtained from CFD and based on the resulting stress profiles, evaluated creep-fatigue damage with a goal of achieving a 30-year service life. Analysis showed a significant impact of the particle-to-wall heat transfer coefficients (HTCs) on receiver performance, with higher HTCs resulting in reduced stress and increased lifespan. For instance, when using Inconel 740H, increasing the HTC from 800 W/m2 K to 1400 W/m2 K increased the creep life from 4,000 hours to over 100,000 hours. This highlights the importance of understanding and optimizing heat transfer in the design of high-efficiency receivers.

14 SOLAR ENERGY↗

Denudation, solute export, landscape evolution modeling, and geographic information system data for the East River watershed, Colorado, USA (2020-2024)

This data package contains geographic information system (GIS) layers and tabular datasets associated with the study of lithologic controls on denudation, solute export, carbon-scaling relationships, and transient landscape evolution in the East River watershed near Crested Butte, Colorado, USA. The package includes GIS layers used to produce the Figure 2 map, including drainage, hillshade, lithology, sample locations, and basin polygons, together with comma-separated value (CSV) tables and matching CSV data dictionaries. One group of tables reports sample-level and catchment-level information for river-sediment samples analyzed for in situ-produced cosmogenic beryllium-10 (10Be), including sample names, outlet elevations, geographic coordinates, upstream drainage area, rock-type classes, production-rate scaling scheme, analyzed nuclide, catchment-averaged denudation rates, and associated lower and upper analytical uncertainties. Sample and catchment attributes provide the basis for comparing denudation rates across intrusive, shale, sedimentary, and mixed-lithology settings. A second group of tables reports supporting information for landscape-evolution modeling and the mapped geologic framework of the study area. Included files list parameter values and definitions for the two-phase landscape-evolution simulations, summarize full-domain model erosion fluxes and topographic metrics for different simulation configurations, provide a fixed-area carbon-model scaling table, and summarize mapped geologic units within the East River study domain, including geologic code, formation name, lithologic description, mapped area, and lithologic class grouping. Model outputs and geologic summaries support interpretation of transient landscape behavior and its relation to the mapped distribution of shale, intrusive, sedimentary, and surficial units. A third group of tables reports hydrologic and hydrochemical information used to quantify dissolved export from the watershed. Included files provide site-level values for drainage area, mean annual solute export, standard error of annual export, area-normalized solute yield, and equivalent weathering rate for five East River monitoring sites, along with metadata describing the number, sampling cadence, and date range of discharge records and partial and full total dissolved solids observations used in the solute-yield analyses. The package also contains a supplementary daily ion-load time series with daily mean discharge, discharge observation counts, dissolved concentrations, and daily loads for calcium, magnesium, sodium, potassium, chloride, sulfate, nitrate, fluoride, dissolved silica, charge-balance bicarbonate, and total dissolved solids. The package contains GIS files, comma-separated value files (.csv), CSV data dictionaries, a file-level metadata table, a package-tree text file, and a readme text file.

10Be↗

Theoretical analysis of a refrigerant injection-enhanced air source heat pump with thermal energy storage for extended cold-climate and defrosting operations

This study investigates a conceptual refrigerant injection-enhanced air source heat pump with integrated thermal energy storage (ITES-ASHP) that combines two-phase flash tank injection with phase change material (PCM) thermal energy storage (TES) to extend cold-climate operation and maintain indoor heating during defrost. A steady-state, mode-based thermodynamic cycle model is developed to evaluate heating and defrosting modes with and without refrigerant injection and TES integration over an outdoor temperature range of 8 to −25 °C. The framework is applied to refrigerants R-290, R-454B, R-410 A, and R-32. A parametric study is conducted for an 18-kW system rated for an outdoor temperature of 8 °C, with the compressor frequency scheduled to 150 Hz. The optimal PCM phase-change temperature is identified as 20 °C for R-290, R-454B, and R-410 A, and 15 °C for R-32. At the design condition of −25 °C outdoor temperature, the proposed concept achieves a combined COP of 2.22 for R-290, corresponding to a 60% increase relative to the theoretical single-stage baseline for combined heating and defrosting operation. Safety screening based on compressor discharge temperature (≤ 120 °C) and injection quality (≥ 0.65), together with performance evaluation, indicates that R-290 is the most suitable candidate, followed by R-410 A and R-454B. Under the assumptions and constraints used here, R-32 is found to be less suitable due to excessive discharge temperatures and a higher risk of wet compression.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of binary eutectic Ni alloys for high-temperature applications via laser remelting

It has been recently demonstrated that eutectic alloys processed by additive manufacturing have excellent high-temperature mechanical properties. We suggest that nickel-base eutectic alloys may enable new combinations of structural and functional properties. To this end, we investigate the processability, microstructure, and thermal stability of five, binary near-eutectic Ni-X (X = B, Ce, La, Y, and Zr) alloys processed via surface laser-remelting. The microstructure of all alloys contain a two-phase lamellar eutectic microstructure consisting of γ-Ni and intermetallic phases; this microstructure is significantly finer (100–200 nm lamellar spacing) in the laser-remelted alloys than in the cast substrate (0.5–1.0 µm lamellar spacing). The microhardness of the laser-remelted alloys (550–770 HV) is 35–50% higher than that of the cast alloys (370–570 HV) due to this finer eutectic spacing. An anomalous eutectic microstructure appears at the meltpool boundaries, containing globular and lamellar γ-Ni phases. The alloys contain a high volume fraction (>50 vol%) of intermetallic phase which forms a continuous network, causing brittleness. Following laser-remelting trials, the alloys showed a high density of solid-state cracks, except for the Ni-Zr alloy which processed well. During thermal exposure at 700 and 900°C for up to 500 h, the eutectic microstructure coarsens. Coarsening occurs heterogeneously and initiates at the meltpool boundaries. This process occurs more slowly in the Ni-Zr and Ni-Y alloys, and more rapidly in the remaining alloys, resulting in greater microhardness retention in the Ni-Zr and Ni-Y alloys following thermal exposure at 700°C. Thus, among the five alloys, the Ni-Zr system exhibits a good combination of high-temperature mechanical properties and processability. Here, we conclude with recommendations for future work on designing additively manufactured alloys based on these eutectic Ni systems.

Additive manufacturing↗

SULI Report - Development of a Molten Salt Circulation Loop for in-situ Spectroscopy

This project supports the development of real time optical monitoring capabilities for molten salt reactor (MSR) environments by designing, testing, and refining a molten salt circulation loop suitable for combined laser induced breakdown spectroscopy (LIBS) and ultraviolet visible (UV Vis) absorption measurements. Online spectroscopic monitoring is increasingly important for nuclear safeguards, corrosion tracking, and material accountancy, yet MSR process fluids present substantial challenges due to their chemical complexity and hazards such as high temperatures and radiation. To address these needs, this work focuses on Phase I, the development of a room temperature aqueous circulation loop that serves as a surrogate platform for evaluating flow behavior, optical access, and component performance prior to high temperature salt operation. Initial testing identified several practical issues—including leaks, obstructions, and two-phase flow through the absorption cell—that were systematically resolved through hardware replacement, flow path redesign, and venturi pressure optimization. Relocating the flow cell upstream of the primary venturi enabled periods of stable single-phase flow, demonstrating the feasibility of integrating optical diagnostics into a circulation system. The results of Phase I provide essential design insight for Phase II, which will incorporate furnace compatible materials and LiCl KCl eutectic salt. Completion of the molten salt system will deliver a reusable testbed for evaluating multimodal spectroscopic techniques, advancing nondestructive, real time monitoring tools for future MSR and nuclear fuel cycle applications.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗