Search NASA⌕ Search

SEARCH · Search NASA

Results for “TWS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Evaluating the effects of heatwave events on hydrological processes in the contiguous United States (2003–2022)

Extreme heat and drought conditions are affecting water availability in many regions worldwide, leading to negative impacts on human societies, agriculture, and ecosystems. However, current research lacks comprehensive spatiotemporal analysis examining the interplay between multiple hydrological factors and heatwave events, especially in the context of climate change. This research broadly pertains to understanding the dynamics of hydrological factors and their potential responses to heatwave during warm seasons across the contiguous United States for the period from 2003 to 2022. Utilizing data from the Global Land Data Assimilation System (GLDAS), we analyzed surface runoff, evapotranspiration (ET), precipitation, Groundwater Storage (GWS), Root Zone Soil Moisture (RZSM), and Total Water Storage (TWS) to discern annual patterns and the impacts of heatwave. Further, the spatial patterns of heatwave highlighted a higher occurrence in the western, central, and northeastern U.S., with longer average durations in the western and south-central regions. These events are predominantly dry, characterized by low Relative Humidity (RH), except in the southeastern U.S., where heatwave coincide with high RH levels. Post-heatwave analysis indicated a reduction in GWS, TWS, RZSM, and ET, alongside an increase in surface runoff, RH, and precipitation. An in-depth examination of rainfall and temperature dynamics during heatwave revealed weak correlations between rainfall and temperature, as well as between rainfall and heatwave duration, highlighting the complex nature of these interactions. The study also found an enhanced probability of rainfall following heatwave, particularly in the eastern regions, drawing attention to the potential for increased flood risks post-heatwave. Our findings contribute to the growing body of knowledge on the impacts of heatwave on hydrological factors, providing valuable insights for climate change adaptation and water resource management strategies.

54 ENVIRONMENTAL SCIENCES↗

Deciphering the Role of Total Water Storage Anomalies in Mediating Regional Flooding

Regional floods result from various flood generation mechanisms. Traditional analyses mainly link flooding to extreme rainfall, with limited input from soil moisture. Total water storage (TWS) is a holistic measure of basin wetness, including additional storage components from surface water, snow, and groundwater. Utilizing a new 5-day Gravity Recovery and Climate Experiment and its Follow On (GRACE(-FO)) data set, we investigated the linkage between short-term TWS anomaly (TWSA) and regional flooding. The 5-day TWSA solutions revealed flood signals missed by monthly TWSA solutions. Global basins exhibit distinct storage-discharge co-evolution patterns, offering new insights into flood mechanisms and propensity. Our bivariate event analyses show the annual maximum river discharges co-occur more often with the TWSA maxima than with precipitation in many basins. Further analyses revealed TWSA's time-lagged effect on river discharge, particularly in basins susceptible to floods triggered by saturation-excess runoff. The 5-day TWSA provides a new source of information for enhancing global flood preparedness.

54 ENVIRONMENTAL SCIENCES↗

Enabling Ultralow Volume Analysis with a High-Resolution Ion Mobility Mass Spectrometry Platform

Of all the molecules thought to exist in the universe, it is estimated that researchers only know the chemical structures of 5% of them. Identifying the chemical structures of the remaining 95% has proven extremely challenging because many molecules exhibit low abundance, are contained in small volumes (e.g., <10 nL), do not readily ionize, exhibit similar structures to other molecules, etc. No single analytical technique exists to definitively identify the structure of an unknown molecule, and thus multiple different molecular measurements are typically made (i.e., multi-modal approach). Ion mobility (IMS) and mass spectrometry (MS) are two key tools that researchers use to determine the chemical structures of unknown molecules, and recently high-resolution and ultrahigh resolution IMS-MS instruments have provided greater confidence than ever before. However, HR-IMS-MS instruments typically exhibit low ion utilization efficiency, meaning they require large amounts of sample for an analysis (e.g., >10 µL). Unfortunately, this limitation prohibits the analysis of small volume samples where many unknown molecules exist. Described herein are the efforts made to enable the analysis of ultralow volumes with an HR-IMS-MS platform. A new scanning technique, termed a ‘stuttered traveling wave scan’, was developed as a replacement for the dual-gated scanning technique and works by halting the traveling waves after allowing ions to separate and then repeatedly restarting and stopping the traveling waves to incrementally move ions from the SLIM to the Orbitrap. Ions were stored inside the SLIM while the TWs were stopped, allowing the Orbitrap to perform high-resolution mass analysis. When the Orbitrap was ready, the TWs were restarted for short periods of time (<10 ms) to move ions from the SLIM to the Orbitrap. It was discovered that lower TW amplitudes and speeds than used during IMS separation were required to produce IMS peaks with the highest signal intensities and best resolving powers. The stuttered TW scan was found to produce similar resolutions and signal intensities compared to the dual-gated scanning technique. A new IMS design possessing an intersecting ‘tee’ with a reversible traveling wave was also developed to improve ion utilization efficiency during cyclic operation, which is necessary when only a single IMS spectrum can be acquired, such as when analyzing ultralow volume samples. The new capabilities described in this report lay the groundwork for acquiring HR-IMS-MS spectra of ultralow volume biological samples, such as single cells, where HR-IMS-MS can help elucidate the structures of unknown compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ion Mobility Separations Using Cocentric Architecture

Ion mobility separations are usually performed in linear channels, which, when extended, can have a large footprint. In this work, we explored the performance of an ion mobility device with a curved architecture which can have a more compact form. The Co-centric Ion Mobility Spectrometer (CIMS) works by manipulating ions between two co-centric surfaces, each containing a serpentine track. The mobility separation inside CIMS is achieved using traveling waveforms (TWs). We initially evaluated the device using ion trajectory simulations using SIMION, which indicated that when ions traveled circularly inside CIMS, they resulted in similar resolving powers and transmitted m/z range as traveling in a straight path in structures for lossless ion manipulations (SLIM). We then performed experimental validation of CIMS in conjunction with a TOF MS. The CIMS was made of 2 flexible printed circuit board materials folded into concentric cylinders separated by a gap of 2.8 mm. The device was about 50 mm diameter × 152 mm long and provided 1.846 m of serpentine path length. Three sets of mixtures (Agilent tune mixture, tetraalkylammonium salts, and 8 peptide mixture) and four traveling waveform profiles (square, sine, triangle, and sawtooth) were used. The sawtooth TW profile produced a slightly higher resolving power for the Agilent tuning mixture and tetraalkylammonium ions. The average resolving power for Agilent tune mixture ions ranged from 37 (using sawtooth TW) to 27 (using square TW). For tetraalkylammonium ions, the average resolving powers ranged from 45 (sawtooth TW) to 31 (square TW). For the peptide mixture ions, the resolving power was similar among the four TW profiles and ranged from 51 to 56. The average percent error in TW CCS for the peptide mixture ions ranged was about 0.4%. In conclusion, the new device showed promising results for a device made of a flexible printed circuit board material, but improvements are needed to further increase the resolving power.

59 BASIC BIOLOGICAL SCIENCES↗