An update to the Sandia method for creating Typical Meteorological Years from a limited pool of calendar years

Typical Meteorological Years (TMYs) are essential for the efficient evaluation of energy system performance. Ideally, 30 years of weather data are required to generate TMYs, but significantly fewer years are typically available due to practical limitations. To address this issue, an update to the Sandia method was developed, referred to as the Argonne method, to create TMYs from a limited number of years. Furthermore, this method enhances candidate diversity by systematically shifting original candidate months forward or backward by specific days, creating an expanded pool of candidates. The effectiveness of the Argonne method was validated through statistical testing, comparison of monthly average weather parameters, and numerical simulations. The results demonstrate a high probability of identifying at least one shifted month whose cumulative distribution functions of weather parameters closely align with long-term distributions. In 67 % of all comparisons, the monthly average weather parameters in TMYs generated using the Argonne method exhibit better agreement with long-term averages than TMY3. Moreover, in 74 % of the 318 building simulation cases, the Argonne method outperforms TMY3 in estimating long-term average building heating and cooling demands. Therefore, the Argonne method effectively diversifies the candidate pool and produces typical years that provide more accurate estimations of long-term averages compared to TMY3 when only a limited pool of calendar years (10 years or fewer) is available.

Building energy modeling↗

Investigating Building Energy Consumption and CO2 Emission in Phoenix Using AutoBEM and Future Typical Meteorological Year (fTMY) Weather Data

This research investigates the energy performance and CO2 emissions of each building stock across the Phoenix metropolitan area using the Automatic Building Energy Modeling (AutoBEM) framework and Model America v2 (MAv2) dataset from Oak Ridge National Laboratory (ORNL). Typical Meteorological Year (TMY) and Future Typical Meteorological Year (fTMY) files were used for AutoBEM simulation. The simulation results from TMY and fTMY were compared. It was found that a projected 10.28% increase in total CO2 emissions and a 9.30% rise in total energy consumption by 2080–2099 relative to current typical conditions. The results highlight the disparities in emissions among different building stocks and the influence of climate change on future energy demand. The findings underscore the necessity of targeted policy interventions and retrofitting strategies (eg. advanced HVAC systems, improved insulation, reflective roofing) to mitigate emissions in high-energy-use and emission-intensed buildings, particularly as climate conditions evolve. This study contributes to the growing understanding of building-sector emissions and their long-term implications under future climate scenarios.

Li, Hang [ORNL] (ORCID:0000000306001920)↗

Commercial and Residential Hourly Load Profiles for All Typical Meteorological Year 3 (TMY3) Locations in the United States

One way to achieve grid flexibility is to shed or shift demand to align with changing grid needs. To facilitate this, it is critical to understand how and when energy is used. High-quality end-use load profiles (EULPs) provide this information and can help cities, states, and utilities understand the time-sensitive value of energy efficiency, demand response, and distributed energy resources. Publicly available EULPs have traditionally had limited application because of age and incomplete geographic representation. To help fill this gap, the U.S. Department of Energy funded a 3-year project, End-Use Load Profiles for the U.S. Building Stock, that culminated in this publicly available dataset of calibrated and validated 15-minute-resolution load profiles for all major residential and commercial building types and end uses across all climate regions in the United States. These EULPs were created by calibrating the ResStock and ComStock physics-based building stock models using many different measured datasets, as described in the "Technical Report Documenting Methodology" linked in the submission.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analyzing the Impact of Future Weather Data on Energy Consumption in Weatherization Assistant

This study supports the mission of the U.S. Department of Energy’s Weatherization Assistance Program (WAP), which aims to increase the energy efficiency of dwellings and reduce their total residential expenditures. Specifically, we examine how projected future climate conditions may affect residential building energy performance by integrating future weather data into the National Energy Audit Tool (NEAT). Since WAP evaluates the cost-effectiveness of retrofit measures over lifespans of up to 30 years, accounting for evolving climate conditions is increasingly important. To reflect future household energy demands, this study replaces historically based Typical Meteorological Year (TMY3) weather inputs with Future Typical Meteorological Year (fTMY) datasets derived from global climate model (GCM) projections. A simulation-based framework was established to enable NEAT analysis under future weather conditions. This workflow involves converting EPW-format weather files into JSON inputs compatible with NEAT and generating degree-hour metrics needed for load calculations. The fTMY dataset used in this study was developed by Oak Ridge National Laboratory through downscaling of six GCMs under different emission scenarios and covers the period from 2020 to 2100. In contrast, the TMY3 dataset is based on historical weather data from 1961 to 1990. Simulations were conducted for benchmark single-family prototype buildings across ASHRAE climate zones 1–7, which cover all regions of the U.S. except the subarctic Zone 8 in northern Alaska, evaluating both heating and cooling loads under TMY3 and fTMY conditions. Four foundation types were tested, while heating systems were standardized, as NEAT does not differentiate thermal energy load by HVAC system type in its load calculations. Results show that fTMY weather input consistently yield lower heating loads and higher cooling loads across most locations, aligning with expected climate warming trends. Notably, colder regions such as zones 6A, 6B, and 7 experience marked reductions in heating load, while warmer and transitional zones, such as 2A (Lufkin, TX) and 3C (San Francisco, CA), have substantial increases in cooling loads. Although this study does not directly assess the performance of retrofit measures under future climate conditions, it provides a critical foundation for doing so. By quantifying shifts in baseline (i.e., pre-retrofit case) energy loads between historical and future weather files, the study highlights the importance of integrating climate-responsive data into audit tools. These findings will inform future efforts to evaluate the long-term effectiveness and cost-effectiveness of weatherization measures under changing climate conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of scenario-specific modeling approaches to predict plane of array solar irradiation

The two main objectives of this study are to evaluate the extent to which the prediction of plane of array irradiance is improved when diffuse radiation is predicted using location-specific regression models developed from onsite measured data as against using generalized models and to estimate the expected uncertainties associated with plane of array irradiance predictions under different data collection scenarios likely to be encountered in practical situations.

Moslehi, Salim↗

Performance of Variable Capacity Heat Pumps in a Mixed Humid Climate

Variable capacity heat pumps represent the next wave of technology for heat pumps. In this report, the performance of two variable capacity heat pumps (HPs) is compared to that of a single or two stage baseline system. The units were installed in two existing research houses located in Knoxville, TN. These houses were instrumented to collect energy use and temperature data while both the baseline systems and variable capacity systems were installed. The homes had computer controlled simulated occupancy, which provided consistent schedules for hot water use and lighting. The temperature control and energy use of the systems were compared during both the heating and cooling seasons. Multiple linear regression models were used along with TMY3 data for Knoxville, TN in order to normalize the effect that the outdoor air temperature has on energy use. This enables a prediction of each system's energy use over a year with the same weather. The first system was a multi-split system consisting of 8 indoor units and a single outdoor unit. This system replaced a 16 SEER single stage HP with a zoning system, which served as the baseline. Data was collected on the baseline system from August 2009 to December 2010 and on the multi-split system from January 2011 to January 2012. Soon after the installation of the multi-split system, some of the smaller rooms began over-conditioning. This was determined to be caused by a small amount of continuous refrigerant flow to all of the indoor units when the outdoor unit was running regardless of whether they were calling for heat. This, coupled with the fact that the indoor fans run continuously, was providing enough heat in some rooms to exceed the set point. In order to address this, the indoor fans were disabled when not actively heating per the manufacturer's recommendation. Based on the measured data, the multi-split system was predicted to use 40% more energy in the heating season and 16% more energy in the cooling season than the baseline system, for the typical meteorological year weather data. The AHRI ratings indicated that the baseline system would perform slightly better than the multi-split system, but not by as large of a margin as seen in this study. The multi-split system was able to maintain more consistent temperature throughout the house than the baseline system, but it did allow relative humidity levels to increase above 60% in the summer. The second system was a split system with an inverter driven compressor and a single ducted air handler. This unit replaced a 16 SEER two stage HP with a zoning system. Data was collected on the baseline system from July 2009 to November 2010 and on the ducted inverter system from December 2010 to January 2012. The ducted inverter system did not offer a zone controller, so it functioned as a single zone system. Due to this fact, the registers had to be manually adjusted in order to better maintain consistent temperatures between the two levels of the house. The predicted heating season energy use for the ducted inverter system, based on the measured energy use, was 30% less than that of the baseline system for the typical meteorological year. However, the baseline system was unable to operate in its high stage due to a wiring issue with the zone controller. This resulted in additional resistance heat use during the winter and therefore higher energy use than would be expected in a properly performing unit. The AHRI ratings would indicate that the baseline system would use less energy than the ducted inverter system, which is opposite to the results of this study. During the cooling season, the ducted inverter system was predicted to use 23% more energy than the baseline system during the typical meteorological year. This is also opposite of the results expected by comparing the AHRI ratings. After a detailed comparison of the ducted inverter system's power use compared to that of a recently installed identical system at a retro-fit study house, there is concern that the unit is not operating as intended. The power use and cycles indicate that the unit is performing more like a single stage unit than a variable capacity unit. Analysis of the data indicates that a change in operating behavior occurred during a service call shortly after the installation of the unit. The logbook only indicates that refrigerant charge was added, but does not indicate any other change. This is being investigated further. While the energy comparison results of these two variable capacity heat pumps is generally underwhelming, it is difficult to draw any hard conclusions about the maximum attainable efficiency of these units when optimally installed. Both units appear to have undesirable conditions associated with the installation or operation, which could have had an adverse effect on their energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Impact of Plane-of-Array-Based TMYs on Solar Resource for PV Applications: Preprint

This study attempts to apprise stakeholders about the accurate use of a typical meteorological year (TMY) data set for decision-making that could potentially speed up the acceptance and deployment of projects and reduce risks to financiers and developers. A TMY data set represents hourly concatenation of 12 typical meteorological months constructed using multiyear data sets. Typically, TMY data sets are constructed under horizonal irradiance conditions that are then used in photovoltaic (PV) performance models for available energy calculations in a location after transposing the data to represent a desired plane-of-array (POA) orientation. In this study, we attempt to show that a POA TMY generated with corresponding POA irradiance time-series information produces significantly different results than a POA TMY generated by transposing a TMY data set. In some months, the differences can be more than 3% for irradiance and energy yield. These results point to the need for generating TMY data sets using POA irradiance time series representing the orientation at which PV panels will be deployed.

14 SOLAR ENERGY↗

A Fresh Look at Weather Impact on Peak Electricity Demand and Energy Use of Buildings Using 30-Year Actual Weather Data

Buildings consume more than one third of the world?s total primary energy. Weather plays a unique and significant role as it directly affects the thermal loads and thus energy performance of buildings. The traditional simulated energy performance using Typical Meteorological Year (TMY) weather data represents the building performance for a typical year, but not necessarily the average or typical long-term performance as buildings with different energy systems and designs respond differently to weather changes. Furthermore, the single-year TMY simulations do not provide a range of results that capture yearly variations due to changing weather, which is important for building energy management, and for performing risk assessments of energy efficiency investments. This paper employs large-scale building simulation (a total of 3162 runs) to study the weather impact on peak electricity demand and energy use with the 30-year (1980 to 2009) Actual Meteorological Year (AMY) weather data for three types of office buildings at two design efficiency levels, across all 17 ASHRAE climate zones. The simulated results using the AMY data are compared to those from the TMY3 data to determine and analyze the differences. Besides further demonstration, as done by other studies, that actual weather has a significant impact on both the peak electricity demand and energy use of buildings, the main findings from the current study include: 1) annual weather variation has a greater impact on the peak electricity demand than it does on energy use in buildings; 2) the simulated energy use using the TMY3 weather data is not necessarily representative of the average energy use over a long period, and the TMY3 results can be significantly higher or lower than those from the AMY data; 3) the weather impact is greater for buildings in colder climates than warmer climates; 4) the weather impact on the medium-sized office building was the greatest, followed by the large office and then the small office; and 5) simulated energy savings and peak demand reduction by energy conservation measures using the TMY3 weather data can be significantly underestimated or overestimated. It is crucial to run multi-decade simulations with AMY weather data to fully assess the impact of weather on the long-term performance of buildings, and to evaluate the energy savings potential of energy conservation measures for new and existing buildings from a life cycle perspective.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-Model Future Typical Meteorological (fTMY) Weather Files for nearly every US County

Exploring climate-induced impacts on building energy consumption can provide valuable insights for sustainable energy planning and environmental management in the face of a changing climate. By utilizing future weather data statistically downscaled from the Intergovernmental Panel on Climate Change (IPCC) General Circulation Models (GCMs) from 2020-2100, this paper presents a broadening industry-consensus approach for generating future Typical Meteorological Year (fTMY) weather files through a combination of statistical downscaling and high-performance computing that generalizes across decades, multiple locations for a region, and varying climate models. Furthermore, these fTMY files have been generated for 3,128 US counties for capturing potential weather on a 20-year basis.

Building↗

Spatial Analysis of Stover Moisture Content During Harvest Season in the U.S.

The moisture content of a maturing crop varies as the harvest season progresses. For crop residues such as corn stover, moisture content at the time of harvest can be as high as 75% (wet mass basis) to less than 20% depending on the geographic location (climate conditions) and stage of harvest. Biomass moisture content is critical for baling and extended storage. It is therefore essential to have an estimate of the quantities of corn stover available as wet or dry for various parts of the U.S. To this end, we analyzed hourly weather data (temperature, humidity, and rainfall) from the Typical Meteorological Year v.3 (TMY3) dataset developed by the National Renewable Energy Laboratory. A recently published set of equations for calculating the moisture content of stover as a function of hourly temperature, humidity, and rainfall were used. The annual start and end of corn grain harvest along with annual grain production (in bushels) for each state were extracted from USDA National Agricultural Statistics Service reports. Using these datasets and moisture sorption equations, the percentage of corn stover tonnage with moisture content less than 20%, between 20% and 40%, or greater than 40% was estimated from the length of time that the biomass was in these moisture content ranges. These calculations were carried out for several locations within each of the states for which TMY data were available. It was concluded that about 37.2% of corn stover is dry (<20% moisture content), whereas 36.5% is wet (>40% moisture content) nationwide. The remaining 27.0% of corn stover is between 20% and 40% moisture content. Keywords: Corn stover, Equilibrium moisture content, Field drying, Moisture content, Stover harvest, Typical Meteorological Year data.

09 BIOMASS FUELS↗

Developing a landscape of urban building energy use with improved spatiotemporal representations in a cool-humid climate

Urban buildings account for up to 75% of total energy use in the United States (U.S.). Understanding urban building energy use is important for developing feasible options to mitigate energy use and greenhouse gas emissions. In this study, an improved bottom-up building energy use model, named City Building Energy Use Model (City-BEUM), was developed to estimate building energy use for all buildings in Polk County, Iowa. First, 28 commercial and 6 residential building prototypes were designed by combing Assessor's parcel data and building footprint data. Then, the EnergyPlus in the CityBEUM was calibrated for all building prototypes using the U.S. Energy Information Administration's survey data, monthly utility meter data, and actual weather data. Finally, spatial and temporal variations of building energy use in the study area were estimated using the CityBEUM. Results indicate that the spatial variation of building energy use in the study area can be captured using the CityBEUM. With the monthly-calibrated model, the temporal pattern of urban building energy use can be well represented. The comparison of building energy use using the Typical Meteorological Year and actual weather data demonstrates the importance of using actual weather data in building energy modeling for an improved temporal representation.

CityBEUM, Urban building energy use, High spatiote↗

Evaluation of regression and neural network models for solar forecasting over different short-term horizons

Forecasting solar irradiation has acquired immense importance in view of the exponential increase in the number of solar pho- tovoltaic (PV) system installations. In this article, analyses results involving statistical and machine-learning techniques to predict solar irradiation for di?erent forecasting horizons are reported. Yearlong typical meteorological year 3 (TMY3) datasets from three cities in the United States with di?erent climatic conditions have been used in this analysis. A simple forecast approach that assumes consecutive days to be identical serves as a baseline model to compare forecasting alternatives. To account for seasonal variability and to capture short-term ?uctuations, di?erent variants of the lagged moving average (LMX) model with cloud cover as the input variable are evaluated. Finally, the proposed LMX model is evaluated against an arti?cial neural network (ANN) model. How the one-hour and 24-hour models can be used in conjunction to predict di?erent short-term rolling horizons is discussed, and this joint application is illustrated for a four-hour rolling horizon forecast scheme. Finally, the e?ect of using predicted cloud cover values, instead of measured ones, on the accuracy of the models is assessed. Results show that LMX models do not degrade in forecast accuracy if models are trained with the forecast cloud cover data.

Inanlouganji, Alireza↗

Efficient prediction of concentrating solar power plant productivity using data clustering

Concentrating solar power (CSP) plants convert solar energy to electricity and can be deployed with a thermal storage capability to shift electricity generation from time periods with available solar resource to those with high electricity demand or electricity price. Rigorous optimization of plant design and operational strategies can improve the market-competitiveness and commercial viability; however, such optimization may require hundreds of annual performance simulations, each of which can be computationally expensive when including considerations such as optimization of dispatch scheduling, sub-hourly time resolution, and stochastic effects due to uncertain weather or electricity price forecasts. This paper proposes a methodology to reduce the computational burden associated with simulation of electricity yield and revenue for CSP plants over a single- or multi-year period. Data-clustering techniques are employed to select a small number of limited-duration time blocks for simulation that, when appropriately weighted, can reproduce generation and revenue over a single year or within each year of a multi-year period. After selection of appropriate data features and weighting factors defining similarity between time-series profiles, the methodology captured annual revenue within 2.3%, 1.7%, or 1.2% using simulation of 10, 30, or 50 three-day exemplar time blocks, respectively, for each of three single-year location/weather/market scenarios and five plant configurations ranging from low to high solar multiple and storage capacity. When applied to multi-year datasets, the proposed methodology can capture inter-year variability that is unavailable from typical meteorological year (TMY) datasets while simultaneously requiring simulation of less than a single year of data.

14 SOLAR ENERGY↗