Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tank Pressurization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Methods for Estimating Hydrogen Fuel Tank Characteristics

The pressure vessels needed to store hydrogen for next-generation hydrogen fuel cell vehicles are expected to be a substantial portion of the total system mass, volume, and cost. Gravimetric capacity, volumetric capacity, and cost per kilogram of usable hydrogen are key performance metrics that the U.S. Department of Energy (DOE) uses to determine the viability of hydrogen fuel cell systems. Research and development related to hydrogen storage systems covers a wide range of potential operating conditions, from cryogenic temperatures to high temperatures (above ambient) and low pressure to high pressure. Researchers at PNNL have developed methods for estimating these key pressure vessel characteristics to support on-board hydrogen storage system design and performance evaluation and to support decision-making about DOE hydrogen storage system research investments. This article describes the pressure tank estimation methodology that has been used as a stand-alone calculation and has been incorporated into larger system evaluation tools. The methodology estimates the geometry, mass, and material cost of type I, type III, and type IV pressure vessels based on operating pressure and material strength at the system's operating temperature, using classical thin-wall and thick-wall pressure vessel stress calculations. The geometry, mass, and material cost requirements of the pressure vessel have significant impacts on the total system performance. For example, hydrogen storage materials that can separately achieve a very high hydrogen density can be deemed impractical for use in fuel cell vehicle hydrogen storage systems because the pressure tank containing them is too large, heavy, or expensive. This article describes the design philosophy and analytical process of the tank characteristic estimation methodology, which has been implemented in spreadsheet calculation tools and system-level analysis tools used by DOE researchers. Each of the three tank types (type I, type III, and type IV) uses a different analysis methodology with some common elements. This article also provides examples of implementing the methodology to perform parametric studies of all three pressure vessel types. The goal of this article is to present the methodology in sufficient detail so it can be implemented in other hydrogen fuel cell vehicle design and analysis tools.

42 ENGINEERING↗

Thermodynamic modeling of hydrogen fueling process from high-pressure storage tank to vehicle tank

This study develops a hydrogen fueling station (HFS) thermodynamic model that simulates the actual fueling process in which hydrogen is supplied from a high-pressure (HP) storage tank into a fuel cell electric vehicle (FCEV) tank. To make the model as accurate as possible, we use the same components and specifications as in actual HFSs, such as a pressure control valve, a pre-cooling system, and an FCEV tank. After the components and their specifications are set, pressure and temperature profiles are set as the HP tank supply conditions. Based on the pressure and temperature profiles, the model solves for the temperature, pressure, and mass flow rate of hydrogen at each downstream position, including the inside of the vehicle tank. The values predicted by the model are compared with experimental data, and we show that the developed model makes it possible to accurately simulate those values at any position during the fueling process.

08 HYDROGEN↗

Integrated hydrogen recycle system using pressurized multichamber tank

A multi-chambered electrolyte storage tank for a redox flow battery system, may include first and second electrolyte chambers, and a bulkhead, wherein the first and second electrolyte chambers are fluidly coupled to first and second sides of a redox flow battery cell, respectively, the first and second electrolyte chambers include first and second liquid electrolyte volumes, respectively, and the first and second liquid electrolyte volumes are separated by the bulkhead positioned therebetween. In this way, manufacturing and operational complexity of a redox flow battery system can be reduced.

Song, Yang↗

Temperature Rise on Liner Surfaces of Fuel Cell Electric Vehicle Tanks during Fueling Process

Herein, the temperature of the inner tank walls, or plastic liners, of composite pressure tanks in fuel cell electric vehicles during fueling using three‐dimensional computational fluid dynamics (CFD) models is evaluated. The liner materials are limited to 85.0 °C to prevent thermal stress causing material failure that would result in a hydrogen leak. Therefore, the temperature of hydrogen gas must be limited to below 85.0 °C during the fueling process as dictated by the current fueling protocol. However, there are limited experimental or simulation data confirming that the temperature changes do not exceed the threshold. Herein, the liner temperatures with CFD tank models for two sizes of type IV tanks representative of the upper and lower system bounds that are close to the SAE J2601 fueling protocol (36.0 and 244.0 L) are evaluated. First, each model's reliability is validated with experimental data and then analyzed, and the data are used to evaluate the maximum hydrogen and liner temperatures under real‐world fueling conditions. The evaluation shows that the maximum liner surface temperature of each tank model is at least 7 °C lower than that of the hydrogen. Additionally, there is at least 12 °C difference found between the upper limit and actual liner temperatures.

33 ADVANCED PROPULSION SYSTEMS↗

Additively Manufactured, Lightweight, Low-Cost Composite Vessels for Compressed Natural Gas Fuel Storage

This project will develop a process to combine AM via direct ink writing (DIW) technology for CFC printing and to use design optimization tools pioneered at LLNL, with advances in resin/composite formulation enabled by chemical and nano-material modification to produce lightweight low-cost CNG tanks. Our approach will yield sub-scale prototype composite pressure tanks equivalent to Type-5 CNG vessel designs that demonstrate a potential cost-benefit advantage. Central to our vision is using agile AM and design based on computationally informed DIW of both short and continuous CF, further coupled with high-performance thermoset polymer matrixes modified by emergent nanomaterials. Our single-stage, multi-material AM technology, combined with a decreased volume fraction of CF and an increased proportion of economically advantaged short fiber, all together drive the reduction in manufacturing time and overall cost. Importantly, reductions in continuous fiber and overall fiber volume fraction will be achieved without detriment to the mechanical strength of the composite vessel. This will be achieved by employing a single process using multi materials grading involving a thermoset resin “ink” modified with aligned nanoplatelets to leverage the efficient tortuous-path gas barrier effect, printed as an inner flexible gas barrier as the initial stage in our manufacturing process before compositionally grading the AM feedstock in real-time to transition to a rigid, structural CF-filled resin. The proposed hybrid construction is projected to achieve pressure ratings at a service range of 2,900–3,600 psi with a 3× burst safety factor comparable to conventional filament-wound composite tanks with an estimated 30–50% reduction in total manufacturing cost.

03 NATURAL GAS↗

Estimation of Respirable Aerosol Release Fractions through Stress Corrosion Crack-Like Geometries

The formation of a stress corrosion crack (SCC) in the canister wall of a dry cask storage system (DCSS) has been identified as a potential issue for the long-term storage of spent nuclear fuel. The presence of an SCC in a storage system could represent a through-wall flow path from the canister interior to the environment. Modern, vertical DCSSs are of particular interest due to the significant backfill pressurization of the canister, up to approximately 800 kPa. This pressure differential offers a relatively high driving potential for blowdown of any particulates that might be present in the canister. In this study, the carrier gas flow rates and aerosol transmission properties were evaluated for an engineered microchannel with characteristic dimensions similar to those of an SCC. The microchannel was formed by mating two gage blocks with a slot orifice measuring 28.9 μm (0.0011 in.) tall by 12.7 mm (0.500 in.) wide by 8.86 mm (0.349 in.) long (flow length). Surrogate aerosols of cerium oxide, Ce0 2 , were seeded and mixed inside a pressurized tank. The aerosol characteristics were measured immediately upstream and downstream of the simulated SCC at elevated and ambient pressures, respectively. These data sets are intended to demonstrate a new capability to characterize SCCs under well-controlled boundary conditions. Separate modeling efforts are also underway that will be validated using these data. The test apparatus and procedures developed in this study can be easily modified for the evaluation of more complex SCC-like geometries including laboratory-grown SCC samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Continued Investigations of Respirable Release Fractions for Stress Corrosion Crack-Like Geometries

The formation of a stress corrosion crack (SCC) in the canister wall of a dry cask storage system (DCSS) has been identified as a potential issue for the long-term storage of spent nuclear fuel. The presence of an SCC in a storage system could represent a through-wall flow path from the canister interior to the environment. Modern, vertical DCSSs are of particular interest due to the commercial practice of using relatively high backfill pressures (up to approximately 800 kPa) in the canister to enhance internal natural convection. This pressure differential offers a comparatively high driving potential for blowdown of any particulates that might be present in the canister. In this study, the rates of gas flow and aerosol transmission of a spent fuel surrogate through an engineered microchannel with dimensions representative of an SCC were evaluated experimentally using coupled mass flow and aerosol analyzers. The microchannel was formed by mating two gage blocks with a linearly tapering slot orifice nominally 13 μm (0.005 in.) tall on the upstream side and 25 μm (0.0010 in.) tall on the downstream side. The orifice is 12.7 mm (0.500 in.) wide by 8.89 mm (0.350 in.) long (flow length). Surrogate aerosols of cerium oxide, CeO 2 , were seeded and mixed with either helium or air inside a pressurized tank. The aerosol characteristics were measured immediately upstream and downstream of the simulated SCC at elevated and ambient pressures, respectively. These data sets are intended to demonstrate a new capability to characterize SCCs under well-controlled boundary conditions. Modeling efforts were also initiated that evaluate the depletion of aerosols in a commercial dry storage canister. These preliminary modeling and ongoing testing efforts are focused on understanding the evolution in both size and quantity of a hypothetical release of aerosolized spent fuel particles from failed fuel to the canister interior and ultimately through an SCC.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantification of Aerosol Transmission through Stress Corrosion Crack-Like Geometries

The formation of a stress corrosion crack (SCC) in the canister wall of a dry cask storage system (DCSS) has been identified as a potential issue for the long-term storage of spent nuclear fuel. The presence of an SCC in a storage system could represent a through-wall flow path from the canister interior to the environment. Modern, vertical DCSSs are of particular interest due to the commercial practice of using more significant backfill pressures in the canister, up to approximately 800 kPa. This pressure differential offers a relatively high driving potential for blowdown of any particulates that might be present in the canister. In this study, the rates of gas flow and aerosol transmission of a spent fuel surrogate through an engineered microchannel with dimensions representative of an SCC were evaluated experimentally using coupled mass flow and aerosol analyzers. The microchannel was formed by mating two gage blocks with a linearly tapering slot orifice nominally 13 μm (0.005 in.) tall on the upstream side and 25 μm (0.0010 in.) tall on the downstream side. The orifice is 12.7 mm (0.500 in.) wide by 8.86 mm (0.349 in.) long (flow length). Surrogate aerosols of cerium oxide, CeO 2 , were seeded and mixed with either helium or air inside a pressurized tank. The aerosol characteristics were measured immediately upstream and downstream of the simulated SCC at elevated and ambient pressures, respectively. These data sets are intended to add to previous testing that characterized SCCs under well-controlled boundary conditions through the inclusion of testing improvements that establish initial conditions in a more consistent way. These ongoing testing efforts are focused on understanding the evolution in both size and quantity of a hypothetical release of aerosolized spent fuel particles from failed fuel to the canister interior and ultimately through an SCC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Testing of Microchannels and Lab-Grown Stress Corrosion Cracks for Quantification of Aerosol Transmission

The formation of a stress corrosion crack (SCC) in the canister wall of a dry cask storage system (DCSS) has been identified as a potential issue for the long-term storage of spent nuclear fuel. The presence of an SCC in a storage system could represent a through-wall flow path from the canister interior to the environment. Modern, vertical DCSSs are of particular interest due to the commercial practice of using higher backfill pressures in the canister, up to approximately 800 kPa, compared to their horizontal counterparts. This pressure differential offers a relatively high driving potential for blowdown of any particulates that might be present in the canister. In this study, the rates of gas flow and aerosol transmission of a spent fuel surrogate through an engineered microchannel with dimensions representative of an SCC were evaluated experimentally using coupled mass flow and aerosol analyzers. The microchannel was formed by mating two gage blocks with a linearly tapering slot orifice nominally 13 μm (0.005 in.) tall on the upstream side and 25 μm (0.0010 in.) tall on the downstream side. The orifice is 12.7 mm (0.500 in.) wide by 8.86 mm (0.349 in.) long (flow length). Surrogate aerosols of cerium oxide, CeO 2 , were seeded and mixed with either helium or air inside a pressurized tank. The aerosol characteristics were measured immediately upstream and downstream of the simulated SCC at elevated and ambient pressures, respectively. These data sets are intended to add to previous testing that characterized SCCs under well-controlled boundary conditions through the inclusion of testing improvements that establish initial conditions in a more consistent way. While the engineered microchannel has dimensions similar to actual SCCs, it does not reproduce the tortuous path the aerosol laden flow would have to traverse for eventual transmission. SCCs can be rapidly grown in a laboratory setting given the right conditions, and initial characterization and clean-flow testing has begun on lab grown crack samples provided to Sandia National Laboratories (SNL). Many such samples are required to produce statistically relevant transmission results, and SNL is developing a procedure to produce samples in welded steel plates. These ongoing testing efforts are focused on understanding the evolution in both size and quantity of a hypothetical release of aerosolized spent fuel particles from failed fuel to the canister interior and ultimately through an SCC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technology Strategy Assessment: Findings from Storage Innovations 2030 Bidirectional Hydrogen Storage

Hydrogen is the most common element in the universe, comprising nearly 75% of all normal matter, and it has been used by scientists for centuries, but it was not fully recognized as an element until 1766, when it was isolated by Henry Cavendish. Early work focused on the generation of hydrogen through the oxidation of metals in water, which released hydrogen gas. Hydrogen’s lighter-than-air and flammable properties were immediately used in engines, zeppelins, and as feedstock for a wide variety of chemical reactions. Several approaches were developed for the production of hydrogen with the most common being associated with the production and conversion of hydrocarbon-based fuels. Coal gasification, steam methane reforming, and other reformation processes provide the majority of current hydrogen production due to the relatively low cost of hydrogen produced through these processes. More than 95% of hydrogen production is used for industrial processes rather than energy storage. To facilitate affordable decarbonization of these industrial processes and to advance the use of hydrogen as a fuel in transportation, DOE launched the Hydrogen Shot as part of the Energy Earthshots Initiative. The goal of the Hydrogen Shot is to reduce the cost of clean hydrogen by 80% to $1/kg of clean hydrogen production within one decade (known as the “1 1 1” goal). This is distinct from the Long-Duration Storage Shot, which is the primary focus of this report; however, it is intrinsically linked to bidirectional hydrogen storage. Several important chemical synthesis processes are dependent upon hydrogen, and the production and use of hydrogen is generally driven by its connection to one of these markets. For example, ammonia is one of the most highly produced chemicals in the world and it depends chiefly on hydrogen. Ammonia is primarily used for agricultural fertilizer and is considered to be largely responsible for a doubling of agricultural production per unit of land over the last century. Another one of hydrogen’s primary uses is as a catalyst in petroleum refining during the desulfurization process. Beyond chemical production, hydrogen is used as a reductant in the production of steel and has been demonstrated as a substitute for metallurgical coal in the production of raw iron. It is even used in the hydrogenation reaction for food products to create more shelf-stable semi-solid fats. However, while hydrogen is produced on the order of 100 million metric tons/year globally to feed these industries, more than 95% of hydrogen is produced from hydrocarbons that emit CO2 during the process. Conversely, electrolysis is a process by which electricity is used to separate hydrogen and oxygen in water molecules, usually across a membrane. Hydrogen production via electrolysis lowers the carbon intensity of produced hydrogen when coupled with low-carbon electricity. Currently, global electrolysis capacity is on the order of 1 GW, which equates to about 500 metric tons/day of hydrogen production. To support large-scale industrial decarbonization, capacity will likely need to increase by two to three orders of magnitude. Electrolysis technology is broadly separated into groups that are defined by the electrolyte used, with further subdivision based on the operating characteristics. The majority of commercial electrolyzer systems are based around three main technology groups: liquid alkaline, proton exchange membrane, and solid oxide. Liquid Alkaline (LA) electrolysis is the oldest, most mature, least expensive, and most common commercial technology, with 400 plants in operation by 1902. Its hydrogen output is low relative to the size of the system due to a low current density. LA electrolysis utilizes a liquid potassium hydroxide solution as the electrolyte. Proton exchange membrane (PEM) electrolysis (also known as polymer electrolyte membrane electrolysis), described in 1960, relies on an acid-impregnated polymer membrane as the electrolyte and typically offers three to six times higher hydrogen production per unit cell area than LA electrolysis. Solid oxide electrolysis, or high-temperature electrolysis, utilizes a ceramic cell as the electrolyte and operates on steam rather than liquid water, enabling electrical efficiencies of more than 90%, which is up from 60% with PEM. Two pre-commercial electrolyzer technologies to note are alkaline exchange membrane (AEM) and proton-conducting solid oxide electrolysis cell (SOEC). AEM potentially has the advantages of both LA and PEM technologies in that it is able to use low-cost materials like LA but with the ability to operate at higher output pressures with a smaller footprint like PEM. Proton-conducting SOEC is similar to commercial SOEC, which uses an oxide-conducting ceramic; however, it uses a proton-conducting ceramic that has the potential to operate at lower temperatures and has lower capital costs. Each of these technologies is experiencing a rapid improvement in performance and a reduction in installed cost, and each appears to be well suited to specific applications. Besides differences in the type of electrolyzer used, the main difference in the architecture of bidirectional hydrogen systems is how the hydrogen is stored. Currently, the most cost-effective way to store large amounts of hydrogen gas is underground, such as in large salt caverns that have been hollowed out. These salt caverns are geographically concentrated in small portions of the United States and are not generally near large metropolitan areas; however, other subsurface architectures are being investigated to expand this reach. A more widely deployable option is aboveground pressurized tanks. These systems are about 10 times as expensive because of the materials and safety margins required to hold hydrogen at high pressures. A third option is using materials-based storage, such as liquid organic hydrogen carriers. By reversibly attaching the produced hydrogen to other molecules, it can be stored at near atmospheric pressure and room temperature. This has the potential to reduce the material cost of storage but may result in a reduction in the efficiency of the process because there are both hydrogen uptake and release processes. While materials-based storage has not been used extensively for large-scale hydrogen storage in the past, there is currently significant activity regarding developing materials and processes for use in large-scale hydrogen storage applications. Electrolysis-produced hydrogen offers an unusual opportunity for energy storage applications. Unlike more conventional energy storage approaches, such as batteries, which operate entirely within electrical markets, hydrogen is a valuable product beyond the electric market and can be directed to the most lucrative use. Hydrogen also can be directly converted back to electricity using either a fuel cell or turbine, or it can be sold to other markets, such as chemical synthesis, steel production, or even export. In this way, excess electricity can be upgraded to the most valuable product. Finally, its use can be actively managed between multiple off-takers; for example, local hydrogen storage can provide a specific amount of stored electricity and any excess can be exported to ammonia production. This flexibility is amplified by the fact that hydrogen storage has fully decoupled power and energy components, which allows for affordable scaling options. Together, this allows a substantial amount of creativity to enable the economic utilization of variable power resources while supporting decarbonization of the industry.

08 HYDROGEN↗

A Review of Online Monitoring within Used Nuclear Fuel Recycling Processes

The processing of used nuclear fuels and related materials is often complex and variable. The ability to quickly optimize conditions to the material being processed can aid in increasing efficiency and safety, but requires very quick determination of the conditions present in the feedstock, the process, and the product. Furthermore, accurate quantification of materials such as enriched uranium and plutonium aids in maintaining material accountancy and avoiding nuclear proliferation risks. Traditional analytical methods require process samples to be collected and analyzed in a laboratory, which often takes days to weeks. Online monitoring is suitable for collecting this information nearly instantaneously, enabling much faster optimization of the process or detection of material diversion. Online monitoring is also beneficial as it is typically based on robust and nondestructive analytical methods, so no material is removed as samples. This review examines online monitoring relevant to used nuclear fuel processing for the determination of both chemical and physical parameters. The chemical parameters include quantities such as concentration, isotopic composition, and speciation. These values are often well suited to spectroscopic or spectrometric measurements as they are fast, nondestructive, and easily implemented in an online manner. Physical quantities are often more varied and include temperature, pressure, tank fill levels, and others. Due to the specificity of these quantities, specialized instrumentation is often used. However, this instrumentation is often amendable to online monitoring.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Recent Cryogenic Carbon Capture™ Field Test Results

Sustainable Energy Solutions (SES) has been developing Cryogenic Carbon Capture™ (CCC) since 2008. In that time, two processes have been developed, the External Cooling Loop and Compressed Flue Gas CCC processes (CCC-ECL and CCC-CFG, respectively). The CCC-ECL process cools the flue gas with an external refrigerant loop. This process currently captures up to 1 tonne of CO2 per day (TPD). SES has tested CCC-ECL on real flue gas slip streams from subbituminous coal, bituminous coal, biomass, natural gas, shredded tires, and municipal waste fuels at field sites that include utility power stations, heating plants, cement kilns, and pilot-scale research reactors. The CO2 concentrations from these tests ranged from 5 to 22% on a dry basis. CO2 capture ranged from 95-99+% during these tests. Several other condensable species were also captured including NO2, SO2 and PMxx at 95+%. NO was also captured at a modest rate. The CCC-CFG process has been scaled up to a 0.25 ton per day system. This system has been tested on real flue gas streams including subbituminous coal, bituminous coal, and natural gas at field sites that include utility power stations, heating plants, and pilot-scale research reactors. CO2 concentrations for these tests ranged from 5 to 15% on a dry basis. CO2 capture ranged from 95-99+% during these tests. Several other condensable species were also captured including NO2, SO2, and PMxx at 95+%. NO was also captured at 90+%. Hg capture was also verified and the resulting effluent from CCC-CFG was below a 1ppt concentration. This paper will focus on discussion of the capabilities of CCC generally, the results of CCC-ECL field testing, and future steps surrounding the development of this technology. Test results that will be presented have been collected during 9 months of testing at a commercial power plant under funding from the US Department of Energy (DOE) and the host utility. Testing of one of the systems at a commercial cement plant in the United States will also be discussed. During this testing, the system captured CO2 from the cement plant and stored the CO2 in pressurized tanks. These tanks were provided to a partner company that later used the CO2 in a CO2 utilization demonstration. The CO2 was utilized to cure concrete manufactured using cement from the same plant where the CO2 was captured. This integrated capture and utilization demonstration was the first time that the cement industry has shown in the field that it can sequester its CO2 emissions in its main product stream. This represents a potential game changing solution for industrial CO2 emissions. Operational data and host-site feedback indicate that the CCC process is ideally suited for deployment into a variety of commercial environments. A few areas of de-risking remain to make sure the technology can meet very strict industrial reliability standards. These areas of de-risking are identified and discussed. The product CO2 is shown to meet specification for many uses including industrial and merchant applications. The technology is nearing readiness for deployment at commercial scale and several initial target markets have been identified.

20 FOSSIL-FUELED POWER PLANTS↗

Hydrogen Risk Assessment Models (HyRAM) (V.3.1) (Technical Reference Manual)

The HyRAM software toolkit provides a basis for conducting quantitative risk assessment and consequence modeling for hydrogen infrastructure and transportation systems. HyRAM is designed to facilitate the use of state-of-the-art science and engineering models to conduct robust, repeatable assessments of hydrogen safety, hazards, and risk. HyRAM includes generic probabilities for hydrogen equipment failures, probabilistic models for the impact of heat flux on humans and structures, and experimentally validated first-order models of hydrogen release and flame physics. HyRAM integrates deterministic and probabilistic models for quantifying accident scenarios, predicting physical effects, and characterizing hydrogen hazards (thermal effects from jet res, overpressure effects from deflagrations), and assessing impact on people and structures. HyRAM is developed at Sandia National Laboratories for the U.S. Department of Energy to increase access to technical data about hydrogen safety and to enable the use of that data to support development and revision of national and international codes and standards. HyRAM is a research software in active development and thus the models and data may change. This report will be updated at appropriate developmental intervals. This document provides a description of the methodology and models contained in HyRAM version 3.1. There have been several impactful updates since version 3.0. HyRAM 3.1 contains a correction to use the volume fraction for two-phase speed of sound calculations; this only affects cryogenic releases in which two-phase ow (vapor and liquid) is predicted in the orifice. Other changes include clarifications that inputs for tank pressure should be given in absolute pressure, not gauge pressure. Additionally, the interface now rejects invalid inputs to probability distributions, and the less accurate single-point radiative source model selection was removed from the interface.

08 HYDROGEN↗

Process for purifying hydrogen gas for use in fuel cells

The invention generally relates to a process for purifying a hydrogen gas for use in a fuel cell. The process involves taking a hydrogen feed stream from a high-pressure tank and passing it through a purifier comprising an adsorbent to provide a purified hydrogen stream which is sent to a fuel cell. A particular adsorbent which can be used is a metal-organic framework composition. The adsorbent can be housed in a device such as a canister or cartridge having an inlet and outlet port.

Morris, William↗

Precooling system utilizing cryogenic liquid fuels for fueling pressurized vehicle gaseous onboard storage tank system with controlled dispensing temperatures

A method and a precooling system are provided for precooling gaseous fuel supplied for fueling pressurized gaseous vehicle onboard storage tank systems. The precooling system is used in pressurized gaseous fueling stations with source fuels in cryogenic state, such as liquid hydrogen (LH2) and liquefied nature gas (LNG). A thermal buffer heat exchanger includes a heat exchanger medium, and a cold loop and a warm loop contained in the heat exchanger medium. A control unit is configured for controlling cryogenic fuel supplied to the cold loop for cooling the thermal buffer heat exchanger. The thermal buffer heat exchanger enables precooling high pressure gaseous fuel to a preset temperature supplied to a dispenser supplying high pressure gaseous fuel to refuel a vehicle onboard storage tank system.

Elgowainy, Amgad A.↗

Effect of Pressurization on Solid Oxide Cell Oxygen Electrodes: the Role of PrO x Nanoparticle Infiltration

Pressurization of solid oxide cells improves performance by reducing electrode polarization resistance (R P ) and facilitates system integration with balance of plant components such as pressurized storage tanks. However, there are few reports on pressurization effects for electrodes designed for low-temperature operation and utilizing infiltrated catalysts. Here we report an electrochemical impedance spectroscopy study of high performing oxygen electrode materials, SrTi 0.3 Fe 0.63 Co 0.07 O 3-∂ (STFC) and PrO x infiltrated STFC, for oxygen partial pressures ($p$ $o$ 2 ) from 0.1 to 8 atm and temperatures from 550 to 650 °C. decreases more with pressurization for STFC:PrO x , fitting well to with an exponent n~0.3, compared to n~0.25 for STFC. The combination of PrO x infiltration and pressurization yields a substantial R P decrease, e.g., at 600 °C by ~7 times from 0.36 Ω cm 2 at $p$ $o$ 2 = 0.2 atm for STFC to 0.055 Ω cm 2 at $p$ $o$ 2 = 4 atm for STFC:PrO x . Here, a transmission-line-based circuit model impedance fit reveals that the significant oxygen surface reaction (R surf ) resistance contribution decreases substantially with PrO x infiltration; and its $p$ $o$ 2 dependence become more pronounced, with n increasing from ~0.25 to ~0.5. R surf for STFC:PrO x decreases so much at elevated $p$ $o$ 2 that the electrode/electrolyte interface resistance dominates.

25 ENERGY STORAGE↗

Analytical Solutions for Seismic Fluid-Structure Interaction of Head-Supported Cylindrical Tanks

Fluid-structure interaction (FSI) of earthquake shaking is a design consideration in the civil, nuclear, chemical, and mechanical industries. Preliminary sizing of structures and components in these industries will often use analytical solutions because there is insufficient information to warrant the analysis of numerical models. Here, this study extends prior analytical work on seismic FSI of base-supported tanks in the 1980s to accommodate head-supported tanks with geometries similar to those proposed for new-build, liquid (fluid)-filled, advanced reactors. Analytical solutions are derived for flexible, head-supported, cylindrical tanks subjected to small-amplitude, unidirectional, horizontal seismic motion, and address frequencies of lateral motions of the tank, hydrodynamic pressures, frequencies of waves, wave heights, and reactions at the head support. Solutions are presented for a range of tank dimensions and could be used for a) preliminary design of head-supported cylindrical tanks and their supporting structures with idealized seismic input, and b) verification of numerical models to be used for final seismic analysis, design, and probabilistic risk assessment.

42 ENGINEERING↗