Technology Performance Exchange

To address the need for accessible, high-quality data, the Department of Energy has developed the Technology Performance Exchange (TPEx). TPEx enables technology suppliers, third-party testing laboratories, and other entities to share product performance data. These data are automatically transformed into a format that technology evaluators can easily use in their energy modeling assessments to inform procurement decisions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

User-Oriented Modeling Tools for Advanced Hybrid and Climate-Appropriate Rooftop Air Conditioners

Hybrid unitary air conditioning systems offer a pathway to substantially reduce energy use and peak electrical demand for cooling, heating, and ventilation in commercial buildings. Hybrid air conditioners incorporate multiple subsystems that are carefully orchestrated to provide climate- and application-specific efficiency advantages. There are a multitude of hybrid system architectures, but common subsystems include: heat recovery ventilation, indirect evaporative cooling, desiccant dehumidification, variable speed fans, modulating dampers, and multi-stage or variable-speed vapor compression cooling. Categorically, hybrid systems can operate in numerous discrete modes. For example: indirect evaporative cooling may operate for periods when the subsystem provides adequate sensible cooling, then vapor compression cooling will be included when more cooling or dehumidification is necessary. Laboratory assessments, field studies, and simulations have demonstrated that hybrid unitary air conditioners could reduce energy use for cooling and ventilation by 30-90% depending on climate and application. Heretofore, it has been challenging - if not impossible - for practitioners to model hybrid air conditioners as part of building energy simulations; and the limitation has severely obstructed broader adoption of technologies in this class. In this project, we developed a new feature for EnergyPlus that enables modeling hybrid unitary air conditioning equipment for building energy simulations. This is a significant advancement for both theory and practice, and confers public benefit by enabling practitioners to evaluate this compelling efficiency technology as a part of building energy simulations. The feature is a black-box model that requires extensive performance data for each hybrid unitary product. In parallel, we also developed new features for the Technology Performance Exchange to enable manufacturers to submit performance data in a standard format that can be used with the hybrid unitary model in EnergyPlus. Additionally, through this project we expanded university educational resources, and university- manufacturing industry collaborations in the field of energy efficiency technology. Over two years, we involved 20 undergraduate students in ambitious research projects focused on modeling complex multi-mode mechanical systems, supported three mechanical engineering bachelor theses, established undergraduate apprenticeships with multiple industry partners, and involved those partners in the process of design, validation, and debugging for the new EnergyPlus feature. The EnergyPlus feature is described and discussed in an academic article, as well as in an engineering reference, and input/output reference documentation for EnergyPlus. The Technology Performance Exchange features are live and publicly accessible, our manufacturer partners are primed to submit initial product information and performance data to the exchange, and the EnergyPlus feature is scheduled for public release in Spring 2018 as a part of EnergyPlus v8.9.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance characterization of nanofiltration, reverse osmosis, and ion exchange technologies for acetic acid separation

A major obstacle to widespread implementation of bio-based fuels and chemicals is the lack of efficient and costeffective separation methods. To purify acetic acid produced by biochemical conversion of biomass via anaerobic digestion, this work employs two commonly used separation technologies: (1) ion-exchange (IX) resin and (2) pressure-driven membranes. This study tested five commercially available strong- and weak-base anion-exchange resins and five commercially available nanofiltration (NF) and reverse osmosis (RO) membranes. The pH of the feed solution significantly affected adsorption capacity. At pH 6.3, a strong-base IX resin (IRN-78) performed best (95.1% acetate removal). With strong-base IX resins, the Langmuir isotherm model fit well, whereas for weak-base IX resins, the Freundlich isotherm provided a better fit. A pseudo-second-order kinetic model fit well for both IRN-78 and IRA-67. Regarding membrane separation, RO (BW30XFR membrane) achieved the highest rejection (98.6% acetate rejection), whereas an NF membrane (NF*) achieved the best combination of permeate flux (105 L/(h∙m 2 )) and rejection (83.1% acetate rejection). For membrane performance, the experimental data were fit using the solution diffusion model. Increased pH in the feed solution lowered permeate flux but increased acetic acid rejection. Finally, then the acetic acid concentration in the feed solution increased, both permeate flux and acetic acid rejection decreased for membrane NF*.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Heat Exchanger/Humidifier Trade Study and Conceptual Design for the Constellation Space Suit Portable Life Support System Ventilation Subsystem

As development of the Constellation Space Suit Element progresses, designing the most effective and efficient life support systems is critical. The baseline schematic analysis for the Portable Life Support System (PLSS) indicates that the ventilation loop will need some method of heat exchange and humidification prior to entering the helmet. A trade study was initiated to identify the challenges associated with conditioning the spacesuit breathing gas stream for temperature and water vapor control, to survey technological literature and resources on heat exchanger and humidifiers to provide solutions to the problems of conditioning the spacesuit breathing gas stream, and to propose potential candidate technologies to perform the heat exchanger and humidifier functions. This paper summarizes the results of this trade study and also describes the conceptual designs that NASA developed to address these issues.

Paul, Heather L.↗

Heat Exchanger/Humidifier Trade Study and Conceptual Design for the Constellation Space Suit Portable Life Support System Ventilation Subsystem

As development of the Constellation Space Suit Element progresses, designing the most effective and efficient life support systems is critical. The baseline schematic analysis for the Portable Life Support System (PLSS) indicates that the ventilation loop will need some method of heat exchange and humidification prior to entering the helmet. A trade study was initiated to identify the challenges associated with conditioning the spacesuit breathing gas stream for temperature and water vapor control, to survey technological literature and resources on heat exchanger and humidifiers to provide solutions to the problems of conditioning the spacesuit breathing gas stream, and to propose potential candidate technologies to perform the heat exchanger and humidifier functions. This paper summarizes the results of this trade study and also describes the conceptual designs that NASA developed to address these issues.

Paul, Heather L.↗

Multi-Material Topology Optimization for High Performance Heat Exchangers

This award allowed RTX Technology Research Center to demonstrate several key objectives related to the design and manufacture of additive heat exchangers. The focus of the project was on creating a multi-physics, multi-material topology optimization tool, then using it to create an ultra-compact, optimized, fully additive heat exchanger.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Voxel Based Three-Dimensional Topology Optimization of Heat Exchanger Fins

Increasing interest in novel aircraft propulsion systems and potential for unwanted heat generation, or capture and reuse of waste heat, may require increasingly lightweight and high performing heat exchangers. Advances in manufacturing technologies have shown potential to create complex designs, but design tools need more flexibility. This study utilizes genetic algorithm-driven topology optimization to develop high performance heat exchanger fins for critical applications such as aerospace. The solid domain is generated using voxel representation where a voxel value of 1 indicates the solid domain and a voxel value of 0 refers to the fluid domain. The use of voxel representation somewhat matches the digitization of a model that is required to fabricate using additive manufacturing, and also allows for a highly unconstrained geometry. To test the topology optimization approach, a three-dimensional(3D)baseline offset strip fin geometry in steady laminar flow(Reynolds number = 215)with conjugate heat transfer(simultaneous solution of solid and fluid temperature fields)is optimized. New designs are generated using the genetic algorithm (GA) and sent to evaluation by the CFD software OpenFOAM; then the GA sorts and selects the reproduction pool for the following generation. This process is repeated for 60 generations. The study also investigates the effect off in material on the performance of the GA and the resulting designs. The results show that the optimal designs have overall performance improvement of 18% relative to the baseline. Additionally, a fin constructed of a lower conductivity material (such as an Inconel super alloy that might be necessary for waste heat recovery applications)results in lower overall performance improvement (11%)and optimal designs with higher pressure drop relative to their baseline, and relative to optimal designs produced using higher conductivity materials.

3D Optimization↗

A Computational Fluid Dynamic Study on Polymer Heat Exchangers

Polymer heat exchangers have been developed for the applications involving weight restrictions or chemical compatibility and fouling issues owing to the low density, anticorrosive properties, and low thermal expansion of polymers. Recently development of additive manufacturing also brings new opportunities to make polymer heat exchangers with desired design that was hard to realize before. However, due to the lower thermal conductivity polymer composite, the overall heat transfer performance is still a challenge in the polymer heat exchanger technology. In present work, a computational fluid dynamic (CFD) model has been developed to study the overall heat transfer performance of additively manufactured polymer heat exchangers. The CFD results offer an insight of fluid flow and temperature distribution in the polymer heat exchangers. This study provides a guidance not only on the polymer material selection but also on the design of polymer heat exchangers. The conclusions will be helpful to design a polymer heat exchanger whose overall heat transfer performance is comparable to a metal heat exchanger.

Zhang, Mingkan↗

Non-Nuclear Testing of Compact Reactor Technologies at NASA MSFC

Safe, reliable, compact, autonomous, long-life fission systems have numerous potential applications, both terrestrially and in space. Technologies and facilities developed in support of these systems could be useful to a variety of concepts. At moderate power levels, fission systems can be designed to operate for decades without the need for refueling. In addition, fast neutron damage to cladding and structural materials can be maintained at an acceptable level. Nuclear design codes have advanced to the stage where high confidence in the behavior and performance of a system can be achieved prior to initial testing. To help ensure reactor affordability, an optimal strategy must be devised for development and qualification. That strategy typically involves a combination of non-nuclear and nuclear testing. Non-nuclear testing is particularly useful for concepts in which nuclear operating characteristics are well understood and nuclear effects such as burnup and radiation damage are not likely to be significant. To be mass efficient, a SFPS must operate at higher coolant temperatures and use different types of power conversion than typical terrestrial reactors. The primary reason is the difficulty in rejecting excess heat to space. Although many options exist, NASA s current reference SFPS uses a fast spectrum, pumped-NaK cooled reactor coupled to a Stirling power conversion subsystem. The reference system uses technology with significant terrestrial heritage while still providing excellent performance. In addition, technologies from the SFPS system could be applicable to compact terrestrial systems. Recent non-nuclear testing at NASA s Early Flight Fission Test Facility (EFF-TF) has helped assess the viability of the reference SFPS and evaluate methods for system integration. In July, 2011 an Annular Linear Induction Pump (ALIP) provided by Idaho National Laboratory was tested at the EFF-TF to assess performance and verify suitability for use in a10 kWe technology demonstration unit (TDU). In November, 2011 testing of a 37-pin core simulator (designed in conjunction with Los Alamos National Laboratory) for use with the TDU will occur. Previous testing at the EFFTF has included the thermal and mechanical coupling of a pumped NaK loop to Stirling engines (provided by GRC). Testing related to heat pipe cooled systems, gas cooled systems, heat exchangers, and other technologies has also been performed. Integrated TDU testing will begin at GRC in 2013. Thermal simulators developed at the EFF-TF are capable of operating over the temperature and power range typically of interest to compact reactors. Small and large diameter simulators have been developed, and simulators (coupled with the facility) are able to closely match the axial and radial power profile of all potential systems of interest. A photograph of the TDU core simulator during assembly is provided in Figure 2.

Houts, Michael G.↗

Evaluating Microchannel Heat Exchanger Lifetime for Concentrating Solar Power Applications Research Performance Progress Report (RPPR-1)

Microchannel heat exchanger technology is being pursued for next generation CSP concepts for primary power cycle heat addition and power cycle heat recuperation due to the high heat transfer coefficients and pressure containment advantages of small sCO 2 channels. The economics of future CSP plants as dictated by the SETO 2020 or 2030 targets depend on a heat exchanger with a 30-year lifetime (resisting creep, fatigue, corrosion, erosion) and operational characteristics such as fast ramping and the ability to withstand thermal shock. However, the lifetime and operational limits of microchannel heat exchangers operating at high temperatures, particularly those constructed from high-nickel alloys, are not well known. This uncertainty has resulted in heat exchanger vendors not being able to accurately forecast heat exchanger lifetime as required by customers, specify operational limits as required by process engineers to prevent premature heat exchanger failure, or overdesign heat exchanger which leads to higher cost than necessary.

14 SOLAR ENERGY↗

Air-to-Liquid Heat Exchanger Fabricated Using Deposition-Based Additive Manufacturing Processes

Abstract This work describes the use of deposition-based additive manufacturing (AM) techniques to fabricate air-cooled, two-fluid heat exchangers. The project focused on a Heating, Ventilation and Air Conditioning application and used an industry-standard copper/aluminum heat exchanger manufactured with conventional technology as the basis for assessing performance. The manufacturing constraints associated with using deposition-based AM technology for this application include the need for a continuous tool path within each build layer that allows uninterrupted extrusion and therefore defect-free water channel walls that correspond to a reliably leak-tight heat exchanger. A geometry that respects these constraints was developed, simulated, optimized and finally manufactured and tested. The material used was a composite of polymer filled with conductive flakes in order to provide high conductivity in the direction that heat must flow in this heat exchanger, across the wall separating the fluids. The measured performance for several test coupons matched the predicted performance and the test coupons exhibited performance that approach and in some cases exceeds conventional technology

Engineering↗

Fluoride-Catalyzed Siloxane Exchange as a Robust Dynamic Chemistry for High-Performance Vitrimers

Sustainable development of new technologies requires materials having advanced physical and chemical properties while maintaining reprocessability and recyclability. Vitrimers are designed for this purpose; however, their dynamic covalent chemistries often have drawbacks or are limited to specialized polymers. Here, fluoride-catalyzed siloxane exchange is reported as an exceptionally robust chemistry for scalable production of high-performance vitrimers through industrial processing of commodity polymers such as poly(methyl methacrylate), polyethylene, and polypropylene. The vitrimers show improved resistance to creep, heat, oxidation, and hydrolysis, while maintaining excellent melt flow for processing and recycling. Furthermore, the siloxane exchange between different vitrimers during mechanical blending results in self-compatibilized blends without any compatibilizers. In conclusion, this offers a general, scalable method for producing sustainable high-performance vitrimers and a new strategy for recycling mixed plastic wastes.

36 MATERIALS SCIENCE↗

Prototype Vent Gas Heat Exchanger for Exploration EVA - Performance and Manufacturing Characteristics

NASA is developing new portable life support system (PLSS) technologies, which it is demonstrating in an unmanned ground based prototype unit called PLSS 2.0. One set of technologies within the PLSS provides suitable ventilation to an astronaut while on an EVA. A new component within the ventilation gas loop is a liquid-to-gas heat exchanger to transfer excess heat from the gas to the thermal control system s liquid coolant loop. A unique bench top prototype heat exchanger was built and tested for use in PLSS 2.0. The heat exchanger was designed as a counter-flow, compact plate fin type using stainless steel. Its design was based on previous compact heat exchangers manufactured by United Technologies Aerospace Systems (UTAS), but was half the size of any previous heat exchanger model and one third the size of previous liquid-to-gas heat exchangers. The prototype heat exchanger was less than 40 cubic inches and weighed 2.57 lb. Performance of the heat exchanger met the requirements and the model predictions. The water side and gas side pressure drops were less 0.8 psid and 0.5 inches of water, respectively, and an effectiveness of 94% was measured at the nominal air side pressure of 4.1 psia.

Quinn, Gregory J.↗

Development of Advanced Solid Sorbents for Direct Air Capture (Final Report)

RTI International is partnering with Creare, and Mohammed VI Polytechnic University (UM6P) successfully met all major technical objectives as outlined below: Identified one MOF adsorbent for DAC; Identified one amine-P-dendrimer adsorbent for DAC; Performed Computational fluid dynamics simulations of the MOF and amine-P-dendrimer adsorbents and validate them with experimental data; Selected one adsorbent for DAC; Demonstrated the scale-up of selected candidate and perform cost review; Performed a preliminary process design; Performed technology maturation plan and environmental health and safety risk assessment. After a thorough comparison between both adsorbents (MOFs and P-dendrimers) and based on their technical merits, the amine-based P-dendrimers sorbent was selected as the best performing adsorbent for DAC. In fact, the amine-based P-dendrimers have demonstrated superior performance over the MOF sorbents under relevant DAC conditions. The selected sorbent has been used in subsequent projects (DE-FE0032099 and DE-AR0001412) and has demonstrated similar superior performance with no loss of activity after long-term sorption-desorption testing (e.g., 100 cycles). This sorbent has demonstrated a very high and stable sorption performance, excellent kinetics, and fast regeneration at 80 °C, specifically at 75% relative humidity (RH). The incorporation of RTI’s high-performance, high-durability amine-based P-dendrimers sorbent and Creare’s hybrid additive manufacturing (H-AM) technology that will produce high performance, compact heat and mass exchange structures at low cost using methods, will lead to a contactor that is optimized for wind-driven operation. This contactor technology provides a technically viable pathway for reducing the cost of DAC to <$100/tonne of CO 2 .

36 MATERIALS SCIENCE↗

Review and Future Perspective of Central Receiver Design and Performance

Concentrating solar power (CSP) technology provides a commercial solar option to the utility-scale electricity market. CSP is unique in its ability to include low-cost thermal storage; thus, it can generate electricity when the sun is not available and dispatch electricity to meet varying load requirements. Within the suite of CSP technologies, the central receiver design represents the state-of-the-art technology, promising low cost, high performance, and dispatchable energy production. Current total capacity of central receiver plants worldwide is about 1.0 gigawatt (electric) with operating plants in Spain and the United States, as well as projects under construction in Asia, the Middle East, and North Africa. Central receiver technology has been under development since the 1950s, and a variety of central receiver designs have been explored. A distinguishing feature is the heat transfer medium. Central receiver designs exist that use dense fluids, gases, and solid particles in this role. Water/steam and molten salt receivers have been adopted in current commercial plants and are often coupled with a steam-Rankine power cycle with an operating temperature of less than 600 degrees C. Many new central receiver concepts, such as the volumetric air, supercritical carbon dioxide (sCO2), solid particle, and liquid-metal receiver designs, are under active research and development (R&D). New designs target operating temperatures generally higher than 700 degrees C-800 degrees C -- and even above 1000 degrees C -- so that higher-performance power cycles such as the sCO2-Brayton cycle or air-Brayton/steam-Rankine combined cycle can be used to promote greater overall system efficiency. Central receiver thermal storage provides dispatchability unavailable from variable-output renewables such as solar photovoltaic and wind power. Case study analysis of the California grid shows that there is a limit on the amount of non-dispatchable renewable generation that the grid can accommodate, beyond which overgeneration, spillage, and instability may occur. Energy storage may well become a necessity in some areas in order to maintain reliability. Next-generation central receiver technologies will have higher operating temperatures and additional features that allow higher-efficiency power generation and deliver other cost-performance advantages. The underlying innovations will come from areas such as multi-physics modeling, high-temperature materials, novel power cycles and heat exchanger designs, and collector field sensing and performance monitoring technologies. Technology innovation is expected to improve the cost and performance of central receiver designs. To deliver value as a generation and storage option, central receiver technology must also be supported by flexible and robust financial models and comprehensive energy and ancillary service markets justifying the capital-intensive investment. Progress in these areas will position CSP central receiver technology for future deployment.

14 SOLAR ENERGY↗

Engineered Thin Diffusion Layers for Anion-Exchange Membrane Electrolyzer Cells with Outstanding Performance

Anion-exchange membrane electrolyzer cells (AEMECs) are one of the most promising technologies for carbon-neutral hydrogen production. Over the past few years, the performance and durability of AEMECs have substantially improved. Herein, we report an engineered liquid/gas diffusion layer (LGDL) with tunable pore morphologies that enables the high performance of AEMECs. The comparison with a commercial titanium foam in the electrolyzer indicated that the engineered LGDL with thin-flat and straight-pore structures significantly improved the interfacial contacts, mass transport, and activation of more reaction sites, leading to outstanding performance. We obtained a current density of 2.0 A/cm 2 at 1.80 V with an efficiency of up to 81.9% at 60 °C under 0.1 M NaOH-fed conditions. The as-achieved high performance in this study provides insight to design advanced LGDLs for the production of low-cost and high-efficiency AEMECs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Prototype Vent Gas Heat Exchanger for Exploration EVA - Performance and Manufacturing Characteristics

NASA is developing new portable life support system (PLSS) technologies, which it is demonstrating in an unmanned ground based prototype unit called PLSS 2.0. One set of technologies within the PLSS provides suitable ventilation to an astronaut while on an EVA. A new component within the ventilation gas loop is a liquid-to-gas heat exchanger to transfer excess heat from the gas to the thermal control system's liquid coolant loop. A unique bench top prototype heat exchanger was built and tested for use in PLSS 2.0. The heat exchanger was designed as a counter-flow, compact plate fin type using stainless steel. Its design was based on previous compact heat exchangers manufactured by United Technologies Aerospace Systems, but was half the size of any previous heat exchanger model and one third the size of previous liquid-to-gas heat exchangers. The prototype heat exchanger was less than 40 cubic inches and weighed 2.6 lb. The water side and gas side pressure drops were 0.8 psid and 0.5 inches of water, respectively. Performance of the heat exchanger at the nominal pressure of 4.1 psia was measured at 94%, while a gas inlet pressure of 25 psia resulted in an effectiveness of 84%. These results compared well with the model, which was scaled for the small size. Modeling of certain phenomena that affect performance, such as flow distribution in the headers was particularly difficult due to the small size of the heat exchanger. Data from the tests has confirmed the correction factors that were used in these parts of the model.

Jennings, Mallory↗

High Performance Computing to Enable Next-Generation Low-Temperature Waste Heat Recovery

US manufacturing industry fails to recover an estimated 900 trillion BTUs of low-temperature waste heat from its processes each year. A grand research challenge has been to develop waste heat recovery technology that can be applied to industrial manufacturing processes and vehicle operations. The Oak Ridge National Laboratory (ORNL)/Eaton research team performed computational research and development to design an innovative direct-contact heat exchanger (DCHE) technology to deliver low-cost, compact, longer-lifetime, high-efficiency waste heat recovery that is optimized for a low-temperature organic Rankine cycle. ORNL resources and expertise in high performance computing (HPC) and multiphase flows were utilized to realize this goal while advancing the fundamental understanding of two-phase, two-immiscible-fluid turbulent flow heat transfer for heat exchangers. In the first stage of the project, a computational fluid dynamics (CFD) model of a DCHE was developed. Verification and limited validation of the numerical solution were performed using experimental data from published literature. To support efforts in verification and validation, two-dimensional CFD models were also developed with the objective of investigating different boundary conditions to reach converged, steady-state solutions.Based on benchmarking efforts, a baseline industry-grade design of a DCHE was developed, which consists of two horizontal pipes of different cross-sectional areas – joined by a converging-diverging nozzle in the middle and relies on a three-phase system with co-current flows for operation. Evaporation of the cold liquid (n-pentane or methanol) by the hot liquid water occurs in the first pipe. The first pipe contains two inlets for liquid water and liquid pentane (or liquid methanol). The second pipe with the larger cross-sectional area serves as a gravity-driven phase-separator. It contains two outlets that are staggered to avoid entrainment of the liquid water phase by the gas phase. This baseline design resulted from several trial-and-error evaluations using two-dimensional CFD models. Confirmatory three-dimensional CFD models were also run for different mass flow rates and inlet temperatures (inlet water temperature ranging from 50°C to 90°C), and efficiency plots were produced to fully characterize the proposed industrial-grade design of the DCHE.