Comparison of Exhibited Wear in Tefzel?, Kynar?, and UHMWPE Valve Seats Exposed to Cyclic Operations with Abrasive Slurry - 17519

Pacific Northwest National Laboratory (PNNL) conducted abrasive-wear testing of ball valves used for double valve isolation in nuclear waste process lines. The valve seat materials consisted of Kynar{sup R}, Tefzel{sup R}, and ultra-high-molecular-weight polyethylene (UHMWPE). Cycle testing was conducted for 1500 operating cycles for the Kynar{sup R} and Tefzel{sup R} valve seats and 5500 cycles for the UHMWPE valve seats. A valve operational cycle consisted of slurry flow, slurry gravity drain, flush water flow, and flush water gravity drain. Both two-way and three-way valves were evaluated, and valves were configured in simulated manifolds so the impact of serving various operational functions (e.g., slurry, flush, or drain control) could be evaluated as some valves are flushed prior to being cycled and others are not. Testing was conducted in PNNL's Multi-Phase Transport Evaluation Loop Facility using a performance-based simulant developed by PNNL specifically for this test program to emulate abrasive slurries for Hanford Tank Farms Waste Transfer System during single-shell tank retrieval and waste feed delivery to the Hanford Tank Waste Treatment and Immobilization Plant. Pre- and post-test valve tear-down evaluations were conducted to observe changes in the condition of internal components for the various seat materials. The various forms of physical wear observed for the different seat materials are presented. The wear results can be used to assess seat materials and valve configurations for application to waste transfer operations, and the observed wear mechanisms can provide insight into assessing valve service life. This information will be used to identify and select additional valve designs that should be evaluated for certification for future use. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Compatibility of Tefzel™ and Viton™ B with Caustic-Side Solvent Extraction Solvents

The Salt Waste Processing Facility (SWPF) plans to switch from the current Caustic-Side Solvent Extraction (CSSX) solvent to the Next Generation Solvent-Phase II (NGS-Phase II). SRNL was requested to evaluate the compatibility between polymeric materials of construction at SWPF and NGS-Phase II solvent. The work presented here concentrated on two materials of interest: Tefzel™ and Viton™ B.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Next Generation Solvent – Materials Compatibility with Polymer Components within Modular CausticSide Solvent Extraction Unit (Final Report)

The Office of Waste Processing, within the Office of Technology Innovation and Development, is funding the development of an enhanced solvent for deployment at the Savannah River Site for removal of cesium from High Level Waste. The technical effort is collaboration between Oak Ridge National Laboratory (ORNL), Savannah River National Laboratory (SRNL), and Argonne National Laboratory. The first deployment target for the technology is within the Modular Caustic-Side Solvent Extraction Unit (MCU). Deployment of a new chemical within an existing facility requires verification that the chemical components are compatible with the installed equipment. In the instance of a new organic solvent, the primary focus is on compatibility of the solvent with organic polymers used in the facility. This report provides the data from exposing these polymers to the Next Generation Solvent (NGS). The test was conducted over six months. An assessment of the dimensional stability of polymers present in MCU (i.e., PEEK, Grafoil, Tefzel and Isolast) in the modified NGS (where the concentration of LIX®79 and MaxCalix was varied systematically) showed that LIX®79 selectively affected Tefzel and its different grades (by an increase in size and lowering its density). The copolymer structure of Tefzel and possibly its porosity allows for the easier diffusion of LIX®79. Tefzel is used as the seat material in some of the valves at MCU. Long term exposure to LIX®79, may make the valves hard to operate over time due to the seat material (Tefzel) increasing in size. However, since the physical changes of Tefzel in the improved solvent are comparable to the changes in the CSSX baseline solvent, no design changes are needed with respect to the Tefzel seating material. PEEK, Grafoil and Isolast were not affected by LIX®79 and MaxCalix within six months of exposure. The initial rapid weight gain observed in every polymer is assigned to the finite and limited uptake of Isopar® L/Modifier by the polymers probably due to the polymers porosity and rough surfaces. Spectroscopic data on the organic liquid and the polymer surfaces showed no preferential adsorption of any component in the NGS to the polymers and with the exception of CPVC, no leachate was observed in the NGS from any of the polymers studied. The testing shows no major concerns for compatibility over the short duration of these tests but does indicate that longer duration exposure studies are warranted, especially for Tefzel. However, the physical changes experienced by Tefzel in the improved solvent were comparable to the physical changes obtained when Tefzel is placed in CSSX baseline solvent. Therefore, there is no effect of the improved solvent beyond those observed in CSSX baseline solvent.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NEXT GENERATION SOLVENT MATERIALS COMPATIBILITY WITH POLYMER COMPONENTS WITHIN MODULAR CAUSTIC-SIDE SOLVENT EXTRACTION UNIT

The Office of Waste Processing, within the Office of Technology Innovation and Development, is funding the development of an enhanced solvent for deployment at the Savannah River Site for removal of cesium from High Level Waste. The technical effort is collaboration between Oak Ridge National Laboratory (ORNL), Savannah River National Laboratory (SRNL), and Argonne National Laboratory. The first deployment target for the technology is within the Modular Caustic-Side Solvent Extraction Unit (MCU). Deployment of a new chemical within an existing facility requires verification that the chemical components are compatible with the installed equipment. In the instance of a new organic solvent, the primary focus is on compatibility of the solvent with organic polymers used in the facility. This report provides the data from exposing these polymers to the Next Generation Solvent (NGS). The test was conducted over six months. An assessment of the dimensional stability of polymers present in MCU (i.e., PEEK, Grafoil{reg_sign}, Tefzel{reg_sign} and Isolast{reg_sign}) in the modified NGS (where the concentration of the guanidine suppressor and MaxCalix was varied systematically) showed that guanidine (LIX{reg_sign}79) selectively affected Tefzel{reg_sign} (by an increase in size and lowering its density). The copolymer structure of Tefzel{reg_sign} and possibly its porosity allows for the easier diffusion of guanidine. Tefzel{reg_sign} is used as the seat material in some of the valves at MCU. Long term exposure to guanidine, may make the valves hard to operate over time due to the seat material (Tefzel{reg_sign}) increasing in size. However, since the physical changes of Tefzel{reg_sign} in the improved solvent are comparable to the changes in the CSSX baseline solvent, no design changes are needed with respect to the Tefzel{reg_sign} seating material. PEEK, Grafoil{reg_sign} and Isolast{reg_sign} were not affected by guanidine and MaxCalix within six months of exposure. The initial rapid weight gain observed in every polymer is assigned to the finite and limited uptake of Isopar{reg_sign} L/Modifier by the polymers probably due to the polymers porosity and rough surfaces. Spectroscopic data on the organic liquid and the polymer surfaces showed no preferential adsorption of any component in the NGS to the polymers and no leachate was observed in the NGS from any of the polymers studied.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Effect of TiDG, DCiTG (Lix ® reg;79), and Other Suppressors on the Compatibility of NGS with SWPF Polymers

This document provides a screening calculation of the potential miscibility of specific polymers proposed for use in the SWPF, notably polyether-etherketone (PEEK), ultra-high molecular weight polyethylene (UHMWPE), polyvinylidene fluoride (PVDF), Viton ® B fluoroelastomer, and Tefzel ® ethylenetetrafluoroethylene (ETFE) copolymer in different suppressors including trisisodecyl guanidine (TiDG), dicyclohexane-isotrisdecyl guanidine (DCiTG), and two other dicyclohexane guanidine related suppressors. The evaluation suggests that Tefzel ® ETFE may mildly interact with the Next Generation Solvent (NGS) regardless of the suppressor used. Based on this approach (calculations), the other listed polymers appear compatible with the NGS containing the four different suppressors. There is evidence of chemical affinity between Tefzel ® ETFE, Viton ® B with aliphatic amines (which are degradation by-products from the TiDG). In addition, the calculation suggests that drawing miscibility conclusions from exposing polymers to a single pure component may give misleading or incorrect results due to the potential for synergistic effects or other interactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Miscibility Evaluation Of The Next Generation Solvent With Polymers Currently Used At DWPF, MCU, And Saltstone

The Office of Waste Processing, within the Office of Technology Innovation and Development, funded the development of an enhanced Caustic-Side Solvent Extraction (CSSX) solvent for deployment at the Savannah River Site for removal of cesium from High Level Waste. This effort lead to the development of the Next Generation Solvent (NGS) with Tris (3,7-dimethyl octyl) guanidine (TiDG). The first deployment target for the NGS solvent is within the Modular CSSX Unit (MCU). Deployment of a new chemical within an existing facility requires verification that the new chemical components are compatible with the installed equipment. In the instance of a new organic solvent, the primary focus is on compatibility of the solvent with organic polymers used in the affected facility. This report provides the calculated data from exposing these polymers to the Next Generation Solvent. An assessment of the dimensional stability of polymers known to be used or present in the MCU, Defense Waste Processing Facility (DWPF), and Saltstone facilities that will be exposed to the NGS showed that TiDG could selectively affect the elastomers and some thermoplastics to varying extents, but the typical use of these polymers in a confined geometry will likely prevent the NGS from impacting component performance. The polymers identified as of primary concern include Grafoil ® (flexible graphite), Tefzel ® , Isolast ® , ethylene-propylene-diene monomer (EPDM) rubber, nitrile-butadiene rubber (NBR), styrene-butadiene rubber (SBR), ultra high molecular weight polyethylene (UHMWPE), and fluorocarbon rubber (FKM). Certain polymers like NBR and EPDM were found to interact mildly with NGS but their calculated swelling and the confined geometry will impede interaction with NGS. In addition, it was found that Vellumoid (cellulose fibers-reinforced glycerin and protein) may leach protein and Polyvinyl Chloride (PVC) may leach plasticizer (such as Bis-Ethylhexyl-Phthalates) into the NGS solvent. Either case will not impact decontamination or immobilization operations at Savannah River Site (SRS). Some applications have zero tolerance for dimensional changes such as the operation of valves while other applications a finite dimensional change improves the function of the application such as seals and gaskets. Additional considerations are required before using the conclusions from this work to judge outcomes in field applications. Decane, a component of Isopar L that is most likely to interact with the polymers, mildly interacted with the elastomers and the propylene based polymers but their degree of swelling is at most 10% and the confined geometry that they are typically placed in indicate this is not significant. In addition, it was found that Vellumoid may leach protein into the NGS solvent. Since Vellumoid is used at the mixer in Saltstone where it sees minimum quantities of solvent, this leaching has no effect on the extraction process at MCU or the immobilization process at saltstone. No significant interaction is expected between MaxCalix and the polymers and elastomers used at MCU, DWPF, and Saltstone. Overall, minimal and insignificant interactions are expected on extraction and immobilization operations when MCU switches from CSSX to NGS solvent. It is expected that contacting NGS will not accelerate the aging rate of polymers and elastomers under radiation and heat. This is due to the minimal interaction between NGS and the polymers and the confined geometries for these polymers. SRNL recommends the use of the HSP method (for screening) and some testing to evaluate the impact of other organic such as alcohols, glycolate, and their byproducts on the polymers used throughout the site.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗