At least 19 records

Soil Temperature Sensor Data, 2025, Five sites in Knoxville, Tennessee

This dataset contains surface soil temperature measurements from five urban parks in Knoxville, Tennessee: Cumberland Estates Park (CE), Socially Equal Energy Efficient Development (SD), West View Park (WV), Victor Ashe Park (VA), and West Hills Park (WH). The dataset includes 16 CSV files documenting soil temperature measurements recorded by HOBO Pendant MX Water Temperature Data Loggers. Data collection for all sites began on January 1, 2025. The end time for each sensor is provided in the End Time_2025.csv file. Each logger was installed at a depth of 10 inches and positioned approximately 3 to 6 feet from the weather station at each site. This dataset is part of a broader study examining the effects of soil moisture and plant evapotranspiration on ambient temperature and relative humidity across multiple urban parks in Knoxville.

Salvador, Christian [ORNL] (ORCID:0000000283287777↗

Laboratory Testing of the Temperature Sensor Qualification Device

The Temperature sensor Qualification Device (TQD) has been developed and tested under laboratory conditions to evaluate its thermal performance and the reliability of its retractable sensor system. The TQD is designed to provide an isothermal environment for temperature sensors in both test and reference zones during irradiation experiments. Initial testing revealed minimal radial and azimuthal temperature variations but identified a significant axial gradient. To address this, design modifications were implemented, including enhanced insulation and the addition of a small heater at the device's top. These changes are expected to produce a more uniform axial temperature profile, though further testing is recommended prior to irradiation. The retractable sensor mechanism was rigorously tested, achieving 1,350 cycles at room temperature and 332 cycles at 400°C before failure. The primary failure mechanism was the thermocouple becoming stuck in the wire guide or capillary tube. Based on these results, design improvements were proposed, such as incorporating a load cell for force monitoring and a stepper motor for precise sensor positioning.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of Temperature Effects on GS-13 Short Period Sensors Utilizing Sandia's Seismic Sensor Temperature Testbed

Sandia National Laboratories has fabricated a Seismic Sensor Temperature Testbed (SSTT) suitable for exposing sensors under test to a range of reasonably stable temperatures while a co-located reference sensor is maintained at room temperature. The testbed has proven sufficiently quiet to allow recording of high-coherence signals from regional earthquakes in the passband of the seismometers, allowing a direct comparison of signals between the sensors under test and the reference sensor.

47 OTHER INSTRUMENTATION↗

Wireless High-Temperature Sensor Network for smart boiler systems

This final project report describes the research data and findings. This project aims to develop a new wireless high-temperature sensor network for real-time continuous boiler condition monitoring in harsh environments. Such a wireless high-temperature sensor network enables network-based automatic temperature sensing and data collection, which combined with artificial intelligent (AI) algorithms allow the construction of smart boiler systems with boiling condition management and optimization for significant energy-saving and reliability improvement

42 ENGINEERING↗

Code Description for "Brief Communication: Monitoring snow depth using small, cheap, and easy-to-deploy ground surface temperature sensors"

Temporally continuous snow depth estimates are vital for understanding changing snow patterns and impacts on permafrost in the Arctic. We train a random forest machine learning model to predict snow depth from variability in ground surface temperature. To our knowledge, this is the first time that small ground surface temperature sensors have been used to estimate snow depth. The model performs well at sites where the model was trained and at pan-arctic evaluation sites (RMSE <= 0.15 m). Small temperature sensors are cheap and easy-to-deploy, so this technique enables spatially distributed and temporally continuous snowpack monitoring to an extent previously infeasible. The model is flexible and can be applied to datasets retroactively to retrieve snow depth estimates at additional sites. This code package includes a *.joblib file of the trained random forest model and a *.ipynb file showing how to clean input data, train the random forest model, and apply the model.

Bachand, Claire↗

Passive Temperature Sensors for Nuclear Applications

In April 2007, the Department of Energy (DOE) designated the Advanced Test Reactor (ATR) a National Scientific User Facility (NSUF) to advance US leadership in nuclear science and technology. By attracting new users from universities, laboratories, and industry, this program supports basic and applied nuclear research to help address the nation's energy security needs. In support of this program, the Idaho National Laboratory (INL) established in-house capabilities to develop, fabricate, test, and qualify new and enhanced temperature sensors for irradiation testing. This effort is continuing today through the DOE?s Advanced Sensors and Instrumentation (ASI) program. Although most efforts emphasize sensors capable of providing real-time data, selected tasks have been completed to enhance passive sensors for irradiations where instrumentation leads cannot be included. These sensors include silicon carbide (SiC) monitors, melt wires and the sublime temperature monitor. SiC monitors are available to detect peak irradiation temperatures between 200°C and 800°C in reactor locations where instrumentation leads cannot be used. SiC monitors may be evaluated using specialized equipment installed at INL?s Measurement Sciences Laboratory (MSL). A melt wire inventory is also maintained at MSL. This inventory contains wires for specific use in irradiation experiments ranging in temperatures from 30°C to 1500°C. Melt wires and SiC monitors have had decades of research and application. Recent research has produced a passive monitor known as the sublime temperature monitor. This passive sensor has the capability of recording temperature gradients. This paper will discuss passive temperature sensors currently being researched and implemented under the ASI program.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Passive Temperature Sensors for Nuclear Applications

Thermocouples are generally used to provide real-time temperature indications in instrumented tests performed at material and test reactors. Passive temperature monitors, such as Silicon Carbide (SiC) and melt wires, may be included in such tests as an independent technique of detecting peak temperatures experienced during irradiation. In less expensive static (drop-in) capsule tests, which have no leads attached for real-time data transmission, melt wires, and SiC temperature monitors (TMs) are essentially the only possibility for peak temperature indication. A melt wire involves placing materials (wires) of a known composition and melting temperature in a test. An inventory is maintained at Material Science Laboratory (MSL) for melt wires ranging in temperatures from 30°C to 1500°C. Unfortunately, melt wires are limited in that it can only detect whether a single temperature is or is not exceeded (melt wire melted or not). SiC TMs, which can also be used to detect peak irradiation temperatures, are advantageous because a single monitor can allow to determine the peak temperature reached within a relatively broad range (100 – 1200°C) resulting in accuracies within ±20°C. Irradiation temperature is determined by measuring a property change after isochronal annealing or during a continuously monitored annealing process using specialized equipment at MSL. Recent research has produced a passive monitor known as sublime temperature monitor. This passive sensor has the capability of recording temperature gradients and pinpointing exactly where a temperature is located along that gradient. Long measurement lengths are achieved with very high accuracy in the location of desired temperature measurements (±2 mm over a 1 m span); however, this sensor has not been deployed in a nuclear reactor. This article will focus only on passive temperature sensors currently being researched and implemented under the Advanced Sensors and Instrumentation (ASI) program at Idaho National Laboratory (INL).

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Brief communication: Monitoring snow depth using small, cheap, and easy-to-deploy snow–ground interface temperature sensors

Abstract. Temporally continuous snow depth estimates are vital for understanding changing snow patterns and impacts on permafrost in the Arctic. We trained a random forest machine learning model to predict snow depth from variability in snow–ground interface temperature. The model performed well on Alaska's Seward Peninsula where it was trained and at Arctic evaluation sites (RMSE ≤ 0.15 m). It performed poorly at temperate sites with deeper snowpacks, partially due to training data limitations. Small temperature sensors are cheap and easy to deploy, so this technique enables spatially distributed and temporally continuous snowpack monitoring at high latitudes to an extent previously infeasible.

54 ENVIRONMENTAL SCIENCES↗

Embedded High-Temperature Sensors: Enhancing Thermoelectrical Performance with Refractory Composites Gradient Layers

To monitor the stability of various energy and manufacturing systems, sensors capable of operating at temperatures exceeding 1000 °C in diverse environments for extended durations are essential. However, under harsh conditions, degradation of sensing materials is a concern that can be controlled by embedding the sensors into refractory oxides. Doped-LaCrO3 based composites are excellent candidates for high-temperature sensing applications due to their good thermoelectrical properties. However, chemical reactivity between the conductive phase and the refractory oxides can decrease the performance of the sensors. In this work, it was devised gradient-type protective layers safeguarding conductive phases within embedded thermocouples, which were fabricated and characterized by X-Ray Diffraction for phase development analysis, Scanning Electron Microscopy and Energy-dispersive X-ray spectroscopy for microstructure and cationic interdiffusion kinetics, long-term thermoelectric testing was completed up to 1400 °C. The enhanced performance of these novel sensors addresses a critical limitation, rendering them viable for long-term high-temperature applications.

20 FOSSIL-FUELED POWER PLANTS↗

High-Accuracy and High-Stability Fiber-Optic Temperature Sensors for Coal Fired Advanced Energy

A research team at Michigan State University, led by Dr. Ming Han, has developed a revolutionary fiber-optic thermometer for use in next-generation coal-fired power plants. Funded by the U.S. Department of Energy, this new sensor is designed to measure extremely high temperatures with unmatched accuracy and long-term stability. Unlike conventional optical sensors that can give false readings due to mechanical strain and often drift out of calibration at high heat, this new technology uses a sealed gas chamber as its core. By measuring the temperature-dependent properties of the gas (air or argon), the sensor’s readings remain absolute and reliable, completely unaffected by the physical stresses on the surrounding equipment. The breakthrough design eliminates the need for complex and costly correction systems. It represents a fundamental shift in sensing technology, paving the way for a primary thermometer that maintains calibration and provides foundational accuracy essential for advanced energy systems.

01 COAL, LIGNITE, AND PEAT↗

Soil Temperature Sensor Data, May - December 2024, Five sites in Knoxville, Tennessee

This dataset contains surface soil temperature measurements from five urban parks in Knoxville: Cumberland Estates Park (CE), Socially Equal Energy Efficient Development (SD), West View Park (WV), Victor Ashe Park (VA), and West Hills Park (WH). The dataset comprises 29 Excel (.xlsx) and Comma-Separated Values (.csv) files documenting soil temperature recorded by six HOBO Pendant MX Water Temperature Data Loggers at each site, except for CE, which has five sensors. Each logger was installed at a depth of 10 inches and positioned approximately 3 to 6 feet from the weather station at each site. To open both csv and xlsx files, users can utilize spreadsheet applications such as Microsoft Excel, Google Sheets, LibreOffice Calc, and Apple Numbers. This dataset is part of a broader study examining the effects of soil moisture and plant evapotranspiration on ambient temperature and relative humidity across multiple urban parks in Knoxville, Tennessee.

EARTH SCIENCE > LAND SURFACE > SOILS↗

Silicon Carbide Passive Temperature Sensors at INL

Discuss the SiC passive thermometry methods currently performed at INL and ORNL, decide on best path forward for establishing an ASTM Standard for processing SiC temperature monitors, and expand this ASTM benchmarking efforts to international collaborators (Netherlands, Canada, and Poland).

36 MATERIALS SCIENCE↗

Passive Wireless Sensors for Realtime Temperature and Corrosion Monitoring of Coal Boiler Components Under Flexible Operation (Final Technical Report)

Researchers at West Virginia University (WVU) propose to demonstrate inexpensive wireless, high-temperature sensors for real-time monitoring of the temperature and corrosion of metal components, which are commonly used in coal-fired boilers. This study presents the development of cost-effective wireless high-temperature sensors for real-time temperature and corrosion monitoring in coal-fired boilers' metal components. The focus is on fabricating and evaluating chipless radio-frequency identification (RFID) sensors capable of operating between 25-1300 ºC. Efforts were directed towards designing passive RFID sensor and interrogator antenna with a broad frequency range, optimizing a microstrip patch antenna sensor integrated into a "peel-and-stick" format for efficient application to various metal specimens without altering their geometry. Additionally, this research aimed to assess the sensor responses under accelerated high-temperature conditions, correlating corrosion and cracking mechanisms with sensor data. An investigation of through-wall data acquisition techniques was also planned, facilitating unobtrusive monitoring of sensor responses housed within metal enclosures. Ultimately, this work sought to establish a robust passive wireless sensor system for the continuous health monitoring of metal components in operational settings, thereby contributing to enhanced safety and efficiency in coal-fired power plants.

20 FOSSIL-FUELED POWER PLANTS↗

Sensor Qualification for the Development of Advanced Reactors

A temperature sensor qualification device is undergoing development and testing in order to qualify temperature sensors for advanced reactor metrology applications. This device will provide National Institute of Standards and Technology (NIST) traceable performance testing of temperature sensors while under the high radiation environments experienced while in-core. This is completed by utilizing retractable sensors which transfer the measurements from ex-core to in-core sensors. A detailed discussion of the uncertainty propagation associated with this comparative process is provided. Experimental testing of the temperature distribution occurring in the device has begun and is reported on. It is pertinent to minimize this temperature distribution to prevent variation in sensor measurements. This variation will be indistinguishable from sensor drift for in-pile applications and would result in unnecessarily conservative uncertainty bounds.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗