Search NASA⌕ Search

SEARCH · Search NASA

Results for “Temperature checks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Pre-Symptomatic COVID Screening

Temperature checks for fever are extensively used for preliminary COVID screenings but are ineffective during the incubation stage of infection when a person is asymptotic. Researchers at the European Centre for Disease Prevention and Control concluded that approximately 75% of passengers infected with COVID-19 and traveling from affected Chinese cities would not be detected by early screening. Core body temperature is normally kept within a narrow range and has the smallest relative standard deviation of all vital signs. Heat in the body is prioritized around internal organs at the expense of the periphery by controlling blood flow. In fact, blood flow to the skin may vary by a factor of 100 depending on thermal conditions. This adaptation causes rapid temperature fluctuations in different skin regions from changes in cardiac output, metabolism, and likely cytokine diffusion during inflammation that would not be seen in average core body temperature. Current IR and thermal scanners used for temperature checks are not necessarily reflective of core body temperatures and require cautious interpretation as they frequently result in false positive and false negative diagnosis. Hand held thermometers measure average skin temperatures and can get readings that differ from core body temperature by as much as 7°. Rather than focusing on a core body temperature threshold assessment we believe that variability of temperature patterns using a novel wearable transdermal microneedle sensor will be more sensitive to infections in the incubation stage and propose to develop a wearable transdermal temperature sensor using established Sandia microneedle technology for pre-symptomatic COVID screening that can additionally be used to monitor disease progression at later stages.

47 OTHER INSTRUMENTATION↗

Pre Symptomatic COVID Screening

Temperature checks for fever are extensively used for preliminary COVID screenings but are ineffective during the incubation stage of infection when a person is asymptotic. Researchers at the European Centre for Disease Prevention and Control concluded that approximately 75% of passengers infected with COVID-19 and traveling from affected Chinese cities would not be detected by early screening. Core body temperature is normally kept within a narrow range and has the smallest relative standard deviation of all vital signs. Heat in the body is prioritized around internal organs at the expense of the periphery by controlling blood flow. In fact, blood flow to the skin may vary by a factor of 100 depending on thermal conditions. This adaptation causes rapid temperature fluctuations in different skin regions from changes in cardiac output, metabolism, and likely cytokine diffusion during inflammation that would not be seen in average core body temperature. Current IR and thermal scanners used for temperature checks are not necessarily reflective of core body temperatures and require cautious interpretation as they frequently result in false positive and false negative diagnosis. Hand held thermometers measure average skin temperatures and can get readings that differ from core body temperature by as much as 7°. Rather than focusing on a core body temperature threshold assessment we believe that variability of temperature patterns using a novel wearable transdermal microneedle sensor will be more sensitive to infections in the incubation stage and propose to develop a wearable transdermal temperature sensor using established Sandia microneedle technology for pre symptomatic COVID screening that can additionally be used to monitor disease progression at later stages.

59 BASIC BIOLOGICAL SCIENCES↗

Computer System for Unattended Control of Negative Ion Source

The computer system for control of cw surface-plasma source of negative ions is described. The system provides an automatic handling of source parameters by the specified scenario. It includes the automatic source start and long-term operation with switching and control of the power supplies blocks, setting and reading of source parameters like hydrogen feed, cesium seed, electrodes' temperature, checking of the protection and blockings elements like vacuum degradation, absence of cooling water, etc. The semi-automatic mode of control is also available, where the order of steps and magnitude of parameters, included to scenario, is corrected in situ by the operator. Control system includes the main controller and a set of peripheral local controllers. Commands execution is carried out by the main controller. Each peripheral controller is driven by the stand-alone program, stored in its ROM. Control system is handled from PC via Ethernet. The PC and controllers are connected by fiber optic lines, which provide the high voltage insulation and the stable system operation in spite the breakdowns and electromagnetic noise of cross-field discharge. The PC program for data setting and information display is developed under the LabView.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EPCAPE-PT-LANL Measurements: Ground based counterflow virtual impactor

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Ground based counter flow virtual impactor (Brechtel Inc) Data Notes: A factor of 6.7 needs to be applied to all cloud droplet residual concentration to correct the enhancement of the concentration because all the residual samples collected at 100 lpm were delivered into the 15 lpm of CVI sample flow. [https://amt.copernicus.org/articles/5/1259/2012/amt-5-1259-2012.html] Header: - Visibility[m]: The atmospheric visibility at the time of measurement, expressed in meters. - QualityControl_Flag[bool]: A boolean flag indicating whether the measurement passed quality control checks. - Temperature[C]: The ambient temperature at the time of the measurement, expressed in degrees Celsius. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement. - RelativeHumidity[%]: The relative humidity at the time of the measurement, expressed as a percentage

54 ENVIRONMENTAL SCIENCES↗

PVAnalytics: A Python Package for Automated Processing of Solar Time Series Data

Multiple publicly available software packages exist that analyze solar time series data, including RdTools and Solar Data Tools, among others. Several of these packages contain their own unique quality assurance (QA) and feature recognition algorithms. The python PVAnalytics package was developed to offer an internally consistent source for these analysis tools, making it easier for the end user to deploy these routines on his or her solar data. The PVAnalytics package currently contains routines for outlier detection, inverter clipping detection, irradiance and temperature checks, orientation checks, and data shift detection, among other functions. These functions have been aggregated from various sources including Solar Forecast Arbiter, RdTools, and the QA process developed by NREL's PV Fleets Initiative. We are continuously adding new functionality to the package, including documentation, examples and algorithms. By bundling QA functionality into a single software package, we hope to make PVAnalytics a comprehensive software library to support analysis of solar metadata and time series data.

data cleaning↗

Hydrothermal synthesis, characterization and up/down-conversion luminescence of barium rare earth fluoride nanocrystals

Graphical abstract: Lanthanide ions doped bare earth rare earth fluoride nanocrystals are synthesized by hydrothermal technology and characterized. The down/up-conversion luminescence of them are discussed. - Highlights: • Mixed hydrothermal system H{sub 2}O–OA (EDA)–O-A(LO-A) is used for synthesis. • Barium rare earth fluoride nanocrystals are synthesized comprehensively. • Luminescence for down-conversion and up-conversion are obtained for these systems. - Abstract: Mixed hydrothermal system H{sub 2}O–OA (EDA)–O-A(LO-A) is developed to synthesize barium rare earth fluorides nanocrystals (OA = oleylamine, EDA = ethylenediamine, O-A = oleic acid and LO-A = linoleic acid). They are presented as BaREF{sub 5} (RE = Ce, Pr, Nd, Eu, Gd, Tb, Dy, Y, Tm, Lu) and Ba{sub 2}REF{sub 7} (RE = La, Sm, Ho, Er, Yb). The influence of reaction parameters (rare earth species, hydrothermal system and temperature) is checked on the phase and shape evolution of the fluoride nanocrystals. It is found that reaction time and temperature of these nanocrystals using EDA (180 °C, 6 h) is lower than those of them using OA (220 °C, 10 h). The photoluminescence properties of these fluorides activated by some rare earth ions (Nd{sup 3+}, Eu{sup 3+}, Tb{sup 3+}) are studied, and especially up-conversion luminescence of the four fluoride nanocrystal systems (Ba{sub 2}LaF{sub 7}:Yb, Tm(Er), Ba{sub 2}REF{sub 7}:Yb, Tm(Er) (RE = Gd, Y, Lu)) is observed.

36 MATERIALS SCIENCE↗

Thermal Hydraulic Modeling of an Advanced Nuclear Reactor using open-source MOOSE tools

The aim of this study is to develop model of a small High Temperature Gas cooled Reactor (HTGR) including the balance of plant. This microreactor produces electricity using the thermal power of the nuclear reaction. This work utilizes the MOOSE Multiphysics simulation tools, which are mainly developed at Idaho National Laboratory (INL, Idaho, United States of America). Its thermal-hydraulics and Heat conduction Modules are used to study the fluids behavior in the primary loop and power conversion system and their interactions with the heating structures. More specifically, one verifies that the temperatures, pressures and mass flow rates of the fluids in both loops are consistent and that, at the same time, all the power transfers occur as expected. Moreover, the various mechanical components characteristics (turbine, compressor, pump) are adapted to the reactor operating conditions. This first analysis is conducted using simplified and one-dimensional model for the core. Ultimately, the obtained results are used to build a higher fidelity core model. This step aims to verify that the initial simplified simulation is consistent with the three-dimensional core modeling. In addition, the calculated material temperatures are checked. This study provides a fairly complete model of the thermal hydraulic phenomena for a particular design of High Temperature Gas cooled Reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Tests of by-pass diodes at cryogenic temperatures for the KATRIN magnets

The Karlsruhe Tritium Neutrino experiment (KATRIN) requires a series of superconducting solenoid magnets for guiding beta-electrons from the source to the detector. By-pass diodes will operate at liquid helium temperatures to protect the superconducting magnets and bus bars in case of quenches. The operation conditions of the by-pass diodes depend on the different magnet systems of KATRIN. Therefore, different diode stacks are designed with adequate copper heat sinks assuming adiabatic conditions. The by-pass diode stacks have been submitted to cold tests both at liquid nitrogen and liquid helium temperatures for checking operation conditions. This report presents the test set up and first results of the diode characteristics at 300 K and 77 K, as well as of endurance tests of the diode stacks at constant current load at 77 K and 4.2 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Advancement Of Tritium Powered Betavoltaic Battery Systems FY16 EOY Report

The goal of this work is to increase the power output of tritium-powered betavoltaic batteries and investigate the change in power output and film resistance in real-time during tritium loading of adsorbent films. To this end, several tritium-compatible test vessels with the capability of measuring both the resistivity of a tritium trapping film and the power output of a betavoltaic device in-situ have been designed and fabricated using four electrically insulated feedthroughs in tritium-compatible load cells. Energy conversion devices were received from Widetronix, a betavoltaic manufacturing firm based in Ithaca, NY. Thin films were deposited on the devices and capped with palladium to facilitate hydrogen loading. Gold contacts were then deposited on top of the films to allow resistivity measurements of the film during hydrogen loading. Finally, the chips were wire bonded and installed in the test cells. The cells were then baked-out under vacuum and leak checked at temperature to reduce the chances of tritium leaks during loading. Following the bake-out, IV curves were measured to verify no internal wires were compromised, and the cells were delivered to Tritium for loading. Tritium loading is anticipated in October, 2017.

07 ISOTOPE AND RADIATION SOURCES↗

Simulation of atmospheric temperature effects on cosmic ray muon flux

The collision between a cosmic ray and an atmosphere nucleus produces a set of secondary particles, which will decay or interact with other atmosphere elements. This set of events produced a primary particle is known as an extensive air shower (EAS) and is composed by a muonic, a hadronic and an electromagnetic component. The muonic flux, produced mainly by pions and kaons decays, has a dependency with the atmosphere’s effective temperature: an increase in the effective temperature results in a lower density profile, which decreases the probability of pions and kaons to interact with the atmosphere and, consequently, resulting in a major number of meson decays. Such correlation between the muon flux and the atmosphere’s effective temperature was measured by a set of experiments, such as AMANDA, Borexino, MACRO and MINOS. This phenomena can be investigated by simulating the final muon flux produced by two different parameterizations of the isothermal atmospheric model in CORSIKA, where each parameterization is described by a depth function which can be related to the muon flux in the same way that the muon flux is related to the temperature. This research checks the agreement among different high energy hadronic interactions models and the physical expected behavior of the atmosphere temperature effect by analyzing a set of variables, such as the height of the primary interaction and the difference in the muon flux.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetic and magnetodielectric properties of erbium iron garnet ceramic

An Er{sub 3}Fe{sub 5}O{sub 12} ceramic has been sintered in oxygen atmosphere at 1400 Degree-Sign C for dielectric measurements. Its structural quality at room temperature has been checked by combining transmission electron microscopy and X-ray diffraction. It crystallizes in the cubic space group Ia3d with a = 12.3488(1). The dielectric permittivity ({epsilon} Prime ) and losses (tan {delta}) measurements as a function of temperature reveal the existence of two anomalies, a broad one between 110 K and 80 K, attributed to the Er{sup 3+} spin reorientation, and a second sharper feature at about 45 K associated to the appearance of irreversibility on the magnetic susceptibility curves. In contrast to the lack of magnetic field impact on {epsilon} Prime for the former anomaly, a complex magnetic field effect has been evidenced below 45 K. The isothermal {epsilon} Prime (H) curves show the existence of positive magnetodielectric effect, reaching a maximum of 0.14% at 3 T and 10 K. Its magnitude decreases as H is further increased. Interestingly, for the lowest H values, a linear regime in the {epsilon} Prime (H) curve is observed. From this experimental study, it is concluded that the {epsilon} Prime anomaly, starting above the compensation temperature T{sub c} (75 K) and driven by the internal magnetic field, is not sensitive to an applied external magnetic field. Thus, below 45 K, it is the magnetic structure which is responsible for the coupling between spin and charge in this iron garnet.

36 MATERIALS SCIENCE↗

Initial Radiation of Nuclear Power Plant Components (CRADA NFE-17-06892 Final Report)

As advanced reactor concepts are developed, instrumentation and control (I&C) cables and sensors will play a significant role in assuring their operation is well understood, and safety-related process information can be collected reliably over the course of their design life. As a first step to develop acceptance criteria and define the limits of currently available nuclear I&C cable and sensor technology, a collaboration between Oak Ridge National Laboratory and Analysis and Measurement Services (AMS) Corporation was initiated under the Gateway for Accelerated Innovation in Nuclear (GAIN) Program. This collaborative effort focused on providing technical information related to the combined thermal and radiation aging of nuclear power plant (NPP) cables, companion NPP cable insulation samples, and two prototype temperature and two pressure sensors. This work was carried out using the instrumented gamma irradiation system that is part of the High Flux Isotope Reactor Gamma Irradiation Facility (HFIR GIF). This system provided the opportunity for the condition of the prototype sensors to be tracked during the irradiation in order to determine their functional limits with greater granularity when compared to a simple irradiation insertion at the HFIRGIF. Experimental assemblies for sensor irradiation were successfully completed, and sensor irradiation to accumulated dose of 3000 kGy at a rate of approximately 6 kGy/hr was carried out. Two prototype temperature assemblies were continuously monitored during exposure to 3000 kGy and found to have no observable degradation from the irradiation. Two pressure sensors were first irradiated to 1000 kGy. At which point, one of the sensors was found to operate normally; however, a second sensor failed the operability test. The operable pressure sensor output was then continuously monitored from 1000 kGy to 3000 kGy. The sensor output exhibited steady trendable drift versus the accumulated radiation dose. At the conclusion of the irradiation, the four test sensors were released for laboratory calibration checks. The calibration check of the temperature sensors found no significant change after irradiation compared to baseline measurements before irradiation; however, both pressure sensors failed the post-test calibration checks and both sensors were not functioning properly. These results will help inform sensor manufacturers and I&C design engineers of potential limitations of these types of sensors for use in high radiation environments associated with the compact configuration of new Small Modular Reactors (SMRs) such as NuScale’s reactor power module. Irradiations on NPP cables and companion samples were not completed due to programmatic delays, however a path forward that was based on lessons learned from this project was defined to accommodate future, comparable instrumented gamma irradiations at the HFIR GIF.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-E-J-273: Skin Temperature Recovery Rate as a Potential Predictor for Radiation-Induced Skin Reactions

Purpose: To assess the potential of dynamic infrared imaging to evaluate early skin reactions during radiation therapy in cancer patients. Methods: Thermal images were captured by our home-built system consisting of two flash lamps and an infrared (IR) camera. The surface temperature of the skin was first raised by ∼ 6 °C from ∼1 ms short flashes; the camera then captured a series of IR images for 10 seconds. For each image series, a basal temperature was recorded for 0.5 seconds before flash was triggered. The temperature gradients (ε) were calculated between a reference point (immediately after the flash) and at a time point of 2sec, 4sec and 9sec after that. A 1.0 cm region of interest (ROI) on the skin was drawn; the mean and standard deviations of the ROIs were calculated. The standard ε values for normal human skins were evaluated by imaging 3 healthy subjects with different skin colors. All of them were imaged on 3 separate days for consistency checks. Results: The temperature gradient, which is the temperature recovery rate, depends on the thermal properties of underlying tissue, i.e. thermal conductivity. The average ε for three volunteers averaged over 3 measurements were 0.64±0.1, 0.72±0.2 and 0.80±0.3 at 2sec, 4sec and 9sec respectively. The standard deviations were within 1.5%–3.2%. One of the volunteers had a prior small skin burn on the left wrist and the ε values for the burned site were around 9% (at 4sec) and 13% (at 9sec) lower than that from the nearby normal skin. Conclusion: The temperature gradients from the healthy subjects were reproducible within 1.5%–3.2 % and that from a burned skin showed a significant difference (9%–13%) from the normal skin. We have an IRB approved protocol to image head and neck patients scheduled for radiation therapy.

60 APPLIED LIFE SCIENCES↗

Study of Turbulent Fluctuations Driven by the Electron Temperature Gradient in the National Spherical Torus Experiment

Various theories and numerical simulations support the conjecture that the ubiquitous problem of anomalous electron transport in tokamaks may arise from a short-scale turbulence driven by the electron temperature gradient. To check whether this turbulence is present in plasmas of the National Spherical Torus Experiment (NSTX), measurements of turbulent fluctuations were performed with coherent scattering of electromagnetic waves. Results from plasmas heated by high harmonic fast waves (HHFW) show the existence of density fluctuations in the range of wave numbers k⊥ρe=0.1-0.4, corresponding to a turbulence scale length of the order of the collisionless skin depth. Experimental observations and agreement with numerical results from the linear gyro-kinetic GS2 code indicate that the observed turbulence is driven by the electron temperature gradient. These turbulent fluctuations were not observed at the location of an internal transport barrier driven by a negative magnetic shear.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of turbulent fluctuations driven by the electron temperature gradient in the National Spherical Torus Experiment

Various theories and numerical simulations support the conjecture that the ubiquitous problem of anomalous electron transport in tokamaks may arise from a short-scale turbulence driven by the electron temperature gradient. To check whether this turbulence is present in plasmas of the National Spherical Torus Experiment, measurements of turbulent fluctuations were performed with coherent scattering of electromagnetic waves. Results from plasmas heated by high harmonic fast waves show the existence of density fluctuations in the range of wave numbers k(perpendicular to)rho(e) = 0.1-0.4, corresponding to a turbulence scale length of the order of the collisionless skin depth. Experimental observations and agreement with numerical results from the linear gyro-kinetic GS2 code indicate that the observed turbulence is driven by the electron temperature gradient. These turbulent fluctuations were not observed at the location of an internal transport barrier driven by a negative magnetic shear.

Mazzucato, E.↗

Modeling of On-Cell Reforming Reaction for Planar SOFC Stacks

Planar Solid Oxide Fuel Cell (SOFC) stack is known to suffer thermal problem from high stack temperature during operation to generate high current. On-Cell Reforming (OCR) phenomenon is often used to reduce stack temperature by an endothermic reaction of steam-methane reforming process. RIST conducted single-cell experiment to validate modeling tool to simulate OCR performance including temperature measurement. 2D modeling is used to check reforming rate during OCR using temperature measurement data, and 3D modeling is used to check overall thermal performance including furnace boundary conditions.

30 DIRECT ENERGY CONVERSION↗

Production of high intensity {sup 48}Ca for the 88-Inch Cyclotron and other updates

Recently the Versatile ECR for NUclear Science (VENUS) ion source was engaged in a 60-day long campaign to deliver high intensity {sup 48}Ca{sup 11+} beam to the 88-Inch Cyclotron. As the first long term use of VENUS for multi-week heavy-element research, new methods were developed to maximize oven to target efficiency. First, the tuning parameters of VENUS for injection into the cyclotron proved to be very different than those used to tune VENUS for maximum beam output of the desired charge state immediately following its bending magnet. Second, helium with no oxygen support gas was used to maximize the efficiency. The performance of VENUS and its low temperature oven used to produce the stable requested 75 eμA of {sup 48}Ca{sup 11+} beam current was impressive. The consumption of {sup 48}Ca in VENUS using the low temperature oven was checked roughly weekly, and was found to be on average 0.27 mg/h with an ionization efficiency into the 11+ charge state of 5.0%. No degradation in performance was noted over time. In addition, with the successful operation of VENUS the 88-Inch cyclotron was able to extract a record 2 pμA of {sup 48}Ca{sup 11+}, with a VENUS output beam current of 219 eμA. The paper describes the characteristics of the VENUS tune used for maximum transport efficiency into the cyclotron as well as ongoing efforts to improve the transport efficiency from VENUS into the cyclotron. In addition, we briefly present details regarding the recent successful repair of the cryostat vacuum system.

43 PARTICLE ACCELERATORS↗